Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Coin vending controller
Bluetooth
For water Vending machine For Model No. ECA4058
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Serial no is back side of product
Introduction
ECA 4058 is a coin vending controller. It is used in water vending machines.
We can use JY926 or ICT UCA2 coin acceptor with this controller and any other
coin acceptor can also be attached with the help of customer care support.
This is very high tech as well as price efficient model. This is economical
model for water vending machine. This is highly precise and long durable
product. We can operate it in several operating modes.
It mainly works in two modes. That is flow meter mode and timer mode. Flow
mode and timer mode. These are described below:-
A product of Extreme Controls & Automation pvt.ltd Setting Menu:-
This product is Bluetooth enabled device, it have inbuilt Bluetooth module that can be paired with mobile and laptop. To pair with mobile you need an app Bluetooth spp pro tool, Available on Google play store
ECA- 11641
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
A product of Extreme Control & Automation Pvt. Ltd
Enter pin is 1234 for pairing. When pairing complete the next ask for connect
Now click on connect
Then next ask for
Click on Byte Stream Mode button
A product of Extreme Controls & Automation pvt.ltd
Now when click on Byte stream mode terminal screen will open like:-
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Send Button is here
Now do not wait for waiting to receive .now type and send password to open setting menu
Login Password is required to operate any control panel from android mobile. You may know default password from your administrator .This is six characters password from which login can be done.
All further commands will work only when login is done properly. Any command given without login will revert as invalid command.
If you see invalid command its mean that either you didn’t login or not given command properly.
Command format is [pw][space][password like 123456]. e.g.
pw xxxxxx
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
There are two types of password first is user/operator password and second is master password.
All basic setting can be done by user password, whereas some special setting can be done by master password on demand of administrator only.
Flow Meter Mode In this mode dispense is done based on flow sensor counts. In this mode flow sensor is deployed in dispensing outlet pipe line. Flow meter is used for getting batter accuracy to avoid variation occurred due to increase or decrease tank level. When water flows from flow sensor, there is a wheel in the flow sensor that rotates. The controller senses each rotation when water flows. After completing the counts as programmed by user controller stop the dispensing.
For setting Controller in flow meter mode.
The command format is [mode2][space][f] for flow miter mode
[mode2][Space][t] For timer mode
The factory default is timer mode
e.g.
mode2 f for flow miter mode
mode2 t for timer mode
Coin Acceptor Setting We can use these six types of coins in that coin acceptor.
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Which is called (A for 1 rupee coin) (B for 2 rupee coin) (C for 5 rupee coin) and (D for 10 rupee coin).
Dispense Quantity Setting In this we can program dispense quantity for each type of coins individually. If the controller is set in timer mode then the quantity setting is in multiple of 10milliseconds. For example= If we want to run the relay for 1 second so we program 100 counts for 1 sec.
And if we want to set relay runtime for 5 seconds then we program 500 counts.
The command format is [cnt][space][x][500]
Where
X is replaced by a for 1Rs.
X is replaced by b for 2Rs.
X is replaced by c for 5Rs.
X is replaced by d for 10Rs.
If Controller is operating in flow meter mode
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Then
You give command [cnt][space][x][y]
Where:-
Y is the no. of counts required to complete dispense for that coin.
X is replaced by a for 1Rs.
X is replaced by b for 2Rs.
X is replaced by c for 5Rs.
X is replaced by d for 10Rs.
For example= If we want 100cnt for 1 rupee then we give [cnt][space][a][100] for 1 rupee
e.g.
cnt a100
If you want to know how much quantity for each coin is programmed in setting menu.
So you can read it all in single command. The command format is [cnt][space][?]
e.g.
cnt ?
Coin Acceptor manual
Manual of CH-926
CH-926 is a multi coin selector, can accept up to 6 kinds of different coins at the Same time. This type of coin selector is widely used in Vending machine, Arcade
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Game, Message chair, and other self–management system. CH-926 is mainly based On material, weight and size to identify coins. We use the most up to date algorithm to Design software. Therefore, CH-926 is very stable and accurate even when Environment changes such as temperature, and humidity etc… In order to increase the Accuracy, we suggest different version of coins use different channel to set up.
Specifications
Coin diameter:::: 15mm~32mm Atmospheric pressure:::: 86Kpa—106Kpa Coin thickness::::1.2mm~3.8mm Working humidity::::≤95% Working voltage:::: DC +12V ±10% Speed::::≤0.6s Working current:::: 65mA ±5% Accuracy rate of identification::::99.5% Signal output: pulse
Features
A. Capable of accepting all worldwide Coins and Tokens. B. Intelligent CPU software control and high accuracy. C. Self-programming without PC. D. Accept 1~6 different kinds of coins at the same time. E. Free to set up pulses' output. F. Prevent not only electric shock but also electromagnetic interference. G. Automatic self-tests for problems.
Manual of CH-926
The Process of Setup for Parameters
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
1. Press the "Add" and "minus" buttons at the same time for about three seconds, then the Letter "A" will appear From the LED display. 2. Press the "setup" button once, and the letter "E" will appear. Next, use the buttons to Choose how many kinds of coins you would like to use; then press the "setup" button Again to finish. 3. The letter "H" will appear after pressing the button. Use the "Add" and "minus" buttons to Choose how many Samples you would like to insert later. Next press the "setup" button Again to finish. 4. The letter "P" will appear after pressing the button. Use the "Add" and "minus" buttons to Choose the amount of output's signals/pulses you want. The quantity limited is 50 times. Next, press the "setup" button to finish. 5. The letter "F" will appear after pressing the button. Use the "Add" and "minus" buttons to Choose accuracy. The value is from 1~ 30 and 1 is the most accurate. Normally, 5~10 will Be fine. Next, press the "setup" Button to finish. 6. So far, you have successfully set up the first coin. Please repeat all above procedures until You have set up all the coins. The letter "A" will appear again after all above procedures Are finished. 7. Press the "setup" button, and the letter "E" will appear. Finally, turn off and turn on the Power. The setup will be stored.
You can start sampling after the setup is finished. Please choose at least 20 coins. The
sampling process will affect the accuracy of coin selector.
Sampling
1. Press the "setup" button, then letter "A" will appear from the LED display. 2. Press the "setup" button again, and then letter "A1" will appear. Next, start to insert Sample Coins. The LED Display will show how many coins you insert. The letter "A1" will appear again after Finished. 3. Press the "setup" button again, then the letter "A2" will appear. Next, start to sample 2nd Coin and repeat no. 1 and No. 2 until all the coins are set up . 4. After finished the sampling, press the "setup" button. The letter "A “will appear, then turn
Off and turn on the
Power. Now you can start to use it.
Connections' manual
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
Manual of CH-926
FAQ:
A. Coins can't pass through
1. Check if the connection is correct or poor connection. 2. Check if sampling is appropriate. 3. Check if there is something stuck inside. B. Can't identify outputs
1. Check if 2 way switch -NO. NC. - are correct. 2. Check if Single wire is connected correctly. 3. Check if there is pull-up resistor with signal wire (not allowed). 4. Check if there is something stuck on the channel where the coins pass out. C. Coins cannot pass smoothly
1. Check if the parameter is set up appropriately. 2. Check the accuracy switch 3. Check if there is something stuck on the channel where the coins pass out.
Name and Function
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0
A product of Extreme Controls & Automation pvt.ltd
① LED light - The light of Indication.
② 4pin Socket
③ two way switch – signal output NO. Or NC.
④ Three way switch - Output signal - fast: 20ms, medium: 50ms, slow: 100ms
⑤ 2pin Socket - Electromagnetic valve DC 12V
⑥ “Setup” button
⑦ LED display
⑧ “Add” button - Plus "+" value
⑨ “Minus “button - Minus “-” value
⑩ Coin slot
11 Press-button for removal of blocked coin
12 Return slot of Coin
13 Position of electromagnetic strobe
Warning: - Remember gray wires should never touch
each other while panel on otherwise panel will bloom.
And relay driver will be destroyed.
Manual for Coin Dispensing Controller Model no. ECA4056/4056gsm/ECA4057 Rev-3.0