Blood Bags
Transcript of Blood Bags
Blood ManagementSystem
JMS designs up-to-dateblood management productswith our patients and donors in mind.
Caring for your health
JMS started manufacturing blood bags in 1969 and have now over four decades
of extensive and relevant expertise to meet the challenges presented in research,
development and production of medical devices for blood transfusion applications.
Blood bags manufactured by JMS have a long and laudable reputation for reliability,
superior product quality and assurance. Certi�ed under EN ISO13485 Quality System,
our fastidious production practices and high standards of quality control and
measures in place are driven to ensure that our products meet the stringent
requirements of blood banks and transfusion services which provide lifelines
services to hospitals, patients and donors.
At JMS we believe in
This is our responsible management of whole blood and its components to ensure
more e�ective use of precious blood resources for better health care in today’s
transfusion medicine.
About us
Pg 2
JMS Complete Range ofBlood Management System
page page 246
357
810 11121523
16
14
9
About JMS
Safety Features
Enhanced Features
Blood Banking Accessories
Product Conf igurations
CPD-SAGM System
T-BEXS (CPD-SAGM)
Whole Blood In-line Filter
Cord Blood Bag Collection Set Autologous Bag
Cellaid Serum Collection Bag
Platelet Storage Bag
Dockable Red Cell Leuko-Filtration System
Whole Blood In-line Leuko-Filtration System
Content
Pg 3
ConvenienceJMS Integrated Blood Sampling Port Closed system & reusable blood sampling with vacuum tube
Option to have lid
ReliabilityJMS Blood Sampling Bag Storage container for convenient and contamination free sampling
Volume of diverted blood could be used for laboratory testing
SafetyJMS Needle Protector Anti-stick device to provide healthcare workers and end -users maximum protection from needle stick injury
Safe and e�ective blood transfusion
Safety First. Our concern is not only to guarantee high quality of the bloodcomponents but also to provide maximum safety during blood donationand sample collection.
Pg 4
Superior red blood cellviability for 42 daysstorage
Increased plasmayield
Red blood cell �owproperty comparableto whole blood
Platelet storage for upto 5 days
The system consists of a primary bag containing anticoagulant CPD solution and one satellite bag containing
SAGM (saline-adenine-glucose-mannitol) red cell preservation solution. This additive solution maintains red
blood cell (RBC) viability and lowers the hematocrit of the RBC unit. Consequently JMS CPD-SAGM system
can store RBCs for 42 days while maintaining 80% of post transfusion RBC survival rate.
This additive-solution system also allows larger volume of plasma to be collected. The removal of bu�y coat
and preparation of platelet concentrates from the bu�y coat are easily achieved using this system. JMS CPD
-SAGM system includes a bag with high gas permeability which enables it to store viable platelets for up to
5 days.
CPD-SAGM SYSTEM
Pg 5
Compatible with mostcommercial automaticextractors
Pre-attached bloodsampling port for�exibility
Needle protector forenhanced user safety
JMS T-BEX (Top and Bottom Extraction) System provides greater e�cacy in the separation of blood components
after centrifugation process. It is common for blood banks to use automatic processing machines to standardize
and save manual labour in the extraction of quality Red Blood Cell, Plasma and Platelets from collected Whole
Blood.
This system focuses on the use of the primary bag with Top and Bottom outlet ports which are mounted on
the extractor unit after centrifuge. Using a single press operation, the Platelet-Poor-Plasma is transferred to the
upper transfer bag and the Red Cell Concentrate is pressed concurrently into the lower bag that contains
SAGM solution for the preservation of red cells. The bu�y coat is retained in the primary bag for subsequent
preparation of Platelets and Leukocytes.
T-BEXS (CPD-SAGM)
Pg 6
Ease of application
Start and forget,hands free
Safe and ease handlingof system with in-line�lters
Auto-venting loopsystem
Enhanced �uidrecovery
The world-wide demand for leuko-reduced whole blood has encouraged JMS to develop blood bag systemsthat meet the regulatory guidelines and strict requirements of blood banks especially in Europe and the USmarkets.
Reduction of leukocyte contamination in blood components is important to minimize various side e�ectssuch as non-hemolytic febrile transfusion reactions, transmission of leukocyte-borne virus and preventionof HLA alloimmunization and platelet refractoriness.
In line with our commitment to continuous improvement and safe patient care, we have designed a completeblood bag system for whole blood �ltration that facilitates the handling in whole blood �ltration to meet theEU Standards and AABB requirements regarding safe and e�cient handling.
WHOLE BLOOD IN-LINE LEUKO-FILTRATIONSYSTEM
Pg 7
high yield of plasma- factor VIII
High ef f iciency ofleukocyte removal
excellent viability ofred cells for 42 daysstorage
Rigorous and advanced tests in our JMS research and development institutes as well as in practical use ofblood banks have shown that the LEUKOSEP In-line Filter for whole blood combined with our well-establishedblood bag systems provide a high yield of plasma. This includes a yield of Factor VIII, excellent viability of redcells and removal e�ciency of leukocytes.
Our certi�ed production system includes strict quality assurance, guaranteed with a continuous high andconsistent quality level. The steam sterilization of the complete system and e�cient coiling of the bag, �lterand tubes assure high integrity of the �lter, which provides ease in handling for the donation team.
WHOLE BLOOD IN-LINE FILTER
Filter Performance< 0.8% hemolysis minimum haemoglobin content
of 40 g per unit
> 85% red cell recovery
Residual hold upvolume < 45ml
< 30 min �ltration time
< 1 x 106 leukocytes per unit
The multi layered ceramic based micrco-�bres have proven in tests as well as in practise excellentperformance in �ltration of whole blood.
* Meeting the guidelines in the Council of Europe
Pg 8
Application
Red Cell Concentrate
Volume Derived from 1 unit of 450 - 500ml +/- 10% Whole Blood
Filter Performance Residual Hold UpVolume < 45ml
Leukocyte Removal Rate < 1 x 106/unit
Red Cell Recovery > 85%
Post Filtration Hemolysis < 0.8%
Filtration Time < 30 mins (if processed at room temp)
< 1 hr (if processed in 2-6 deg C)
Post Donation Storage Duration =/< 5 days. Maximum 8 hrs hold at temp prior to whole blood centrifugation
Post Donation Storage TemperaturePerformance Parameters 2 - 6 deg C
State-of-the-artcollection,�ltration andstorage
User-friendly,safe and fasthandling ofsystems
Superb airventing system
Tubing compatiblewith sterile deviceconnection
JMS Leukoreduction and Storage Set for Red Cells is a sterile disposable device intended for reducingleukocytes from a unit of red blood cell. This design provides a safe, e�ective and convenient collection ofred cells coupled with high e�ciency leukocyte �ltration processing.
DOCKABLE RED CELL LEUKO-FILTRATIONSYSTEM
Pg 9
Tubing compatible withsterile device connection
Specially tailored volumeof anticoagulant
Safe blood collectionusing attached needleprotector
Direct sampling withsyringe. Ease indisinfection of port
Ease of cleaning andwater tolerance withpolymeric labels
Option to have doubleneedles and integratedblood sampling port /sampling bag
Cord Blood Bags are designed to collect the umbilical cord blood (also known as placental blood) after the
birth of the baby, within the shortest time and minimal risk of contamination. The clinical use of the cord
blood is allergenic transplantation in patients su�ering from severe blood diseases such as leukemia,
lymphoma, etc.
CORD BLOOD BAG COLLECTION SET
Pg 10
With Special accessoriesfor blood samplingand transfusion
Double layer label forblood collection
Auto-Transfusion is a process where patient receives his or her own blood instead of donor blood. This is a
common pratice for joint replacement surgeries and can be performed before, during or after surgeries.
During autologous blood donation patient donates his or her blood for own use, this process can commence
up to 5 weeks before surgery, which will be stored and reinfused as needed during or after the surgery. As
own blood is receptive to the body, it is an extremely safe way to help the patient in the recovery process.
JMS Autologous Bag is specially designed and used to store patient’s own blood donation for such purpose.
AUTOLOGOUS BAG
Pg 11
Non-Stick TubingCompatible with universal tubesealer & sterile connecting device.Unique printed segment numberfor each unit.
Bag Pro�leRounded corners are designed toavoid friction, smoother transferof blood components duringseparation & transfusion.
Bag LabelDesigned with polymeric tamperproof label, registered in ICCBBAand licensed to use ISBT 128 BarCode for systematic identi�cation.
Needle BevelThe oval slit is pro�led to tip’sgeometry that has much smallerstep for minimal tissue shavingand blood seepage during needleinsertion.
Patient and Donor Safety is our primary concern.With a renowned reputation for full commitment to quality, reliability for our end users, maximum usage andcomfort. JMS Blood Bags are manufactured to the highest quality standards for optimum blood managementincluding collection, separation, preservation and transfusion.
Pg 12
Bag Pro�leRounded corners are designed toavoid friction, smoother transferof blood components duringseparation & transfusion.
Easy Snap-TipSnap-tip enables ease of transferringblood components to satellite bags.
User Friendly Port CoverPort cover can be pulled openwith one hand, avoiding directcontact with the port itself.
Reliable Bag MaterialSpecially formulated and compoundedin-house to meet required standardsfor elution, chemical and biologicalsafety.
Patient and Donor Safety is our primary concern.With a renowned reputation for full commitment to quality, reliability for our end users, maximum usage andcomfort. JMS Blood Bags are manufactured to the highest quality standards for optimum blood managementincluding collection, separation, preservation and transfusion.
Engineered for
JMS Needle is renowned for its superiorneedle sharpness which minimise traumaand puncture pain.
CELLAID SERUM COLLECTION BAG
The serum collection bag contains the platelet activation beads. When beads come into contact with the
blood, they will absorb blood plasma proteins. The platelets will then adhere to the beads which will then
be activated to release growth factors.
*Measuring method: ELISA method
Growth FactorSerumPlasma
PDGF-BB100%2.9%
TGF-B1100%7.4%
HGF100%61.9%
Preparation within 1 hourSpeci�cally designed to prepareserum from fresh whole blood.
Rich in growth factorsPlatelet activation beads areincluded in the collectionbag. Beads accelerate bloodcoagulation and release ofgrowth factors from platelet.
Safety designSerum can be preparedin a completely closedsystem which reduces therisk of contamination andprotects the user fromcoming into contact withblood.
Pg 14
High Gas Permeability In order to maintain aerobicmetabolism of platelet in the bag, high gas permeabilityis one of the most important factors for platelet storagebags. The newly developed material UPX-80 has muchhigher gas permeability than currently available plateletstorage bags and it allows to maintain an optimum pHbalance during storage.
JMS new platelet storage bag with UPX-80 intends to maintain large amount of platelets over 4.0 x 10 cellsfor at least 5 days. After 5 days storage in UPX-80, the indexes of platelets are kept in very good condition.
11
-Electron micrograph- Platelets after 5 days storage (X4000)
PLATELET STORAGE BAG
Pg 15
JMS Single Blood Bag For whole blood collection, preservation and transfusion. When blood component separation is needed, JMS Transfer Bag can be connected as required.
CPDA-1 Solution
Product Con�gurationBlood Sampling System
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17G
Optional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-12-964-01 250ml
90-13-964-01 350ml
90-17-964-01 450ml
90-15-964-01 500ml
Optional Features
*With or without accessories, T&T, BSB, NP, iBSP with or without lid
Super-Thin-Walled UltraSharp Needle Available
in 16G or 17G
JMS Double Blood Bag For whole blood collection and separation of 2 di�erent blood components (Red Blood Cell and Plasma) obtained through the process of centrifugation and extraction.
CPDA-1 Solution
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17G
Optional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-22-964-01 250ml
90-23-964-01 350ml
90-27-964-01 450ml
90-25-964-01 500ml
Optional Features
*With or without accessories, T&T, BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in150ml, 300ml,
and 400ml
JMS Triple Blood Bag For whole blood collection and separation of 3 di�erent blood components namely (Red Blood Cells, Plasma and a bu�ycoat that comprise of Leukocytes and Platelets), obtained through the process of centrifugation and extraction.
CPDA-1 Solution
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17G
Optional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-32-964-01 250ml
90-33-964-01 350ml
90-37-964-01 450ml
90-35-964-01 500ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in150ml, 300ml,
and 400ml
Pg 16
JMS Quadruple Blood Bag For whole blood collection and separation of 4 di�erent blood components (Red Blood Cells, Plasma, Leukocytes and Platelets), obtained through the process of centrifugation and extraction. A specially con�gured transfer bag by JMS is incorporated to ensure the conservation of Platelets for 5 days.
CPDA-1 Solution
JMS Quadruple Blood Bag For whole blood collection and separation of 4 di�erent blood components (Red Blood Cells, Plasma, Leukocytes and Platelets), obtained through the process of centrifugation and extraction. A specially con�gured bag by JMS is incorporated to ensure the conservation of Platelets for 5 days. The primary bag contains anticoagulant CPD solution and one satellite bag with SAGM (Saline-Adenine-Glucose- Mannitol) solution for Red Blood Cell Preservation.
CPD-SAGM Solution
JMS Triple Blood Bag For whole blood collection and separation of 3 di�erent blood components (Red Blood Cells, Plasma and a bu�y-coat that comprise of Leukocytes and Platelets), obtained through the process of centrifugation and extraction. The primary bag contains anticoagulant CPD solution and one satellite bag with SAGM (Saline-Adenine-Glucose-Mannitol) solution for Red Blood Cell Preservation.
CPD-SAGM Solution
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17G
Optional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-42-964-01 250ml
90-43-964-01 350ml
90-47-964-01 450ml
90-45-964-01 500ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in150ml, 300ml,
and 400ml
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-33-764-50 350ml
90-37-764-50 450ml
90-35-764-50 500ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in150ml, 300ml,
and 400ml
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-43-764-50 350ml
90-47-764-50 450ml
90-45-764-50 500ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
N.A
Product Con�gurationBlood Sampling System
Pg 17
JMS Single Blood Bag For whole blood collection and storage. This bag is designed to be re-used for transfusion by the same patient.
CPDA-1 Solution
Product Con�gurationAutologous Bag
Cord Blood Bag
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-13-964-55 350ml
90-13-964-50 450ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Available in16G
Available in150ml
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-21-964-02 250ml Available in16G
Available in150ml
250
150
JMS DoubleCord Blood Processing Bag
For Cord Blood Processing.
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-11-964-02 150ml
90-12-964-02 250ml
Available in16G
Available in150ml
JMS SingleCord Blood Bag
For Cord Blood Collection.
Pg 18
JMS Transfer Bag Bag capacity of 150ml - 2000ml. For blood components from whole blood and procedures that further separates these components.
Product Con�gurationT-Bex System
JMS Quadruple Blood Bag For whole blood collection and separation of 4 di�erent blood components (Red Blood Cells, Plasma, Leukocytes and Platelets), obtained through the process of centrifugation and extraction. JMS T-Bex System comprise of a specially con�gured primary bag containing anticoagulant CPD solution and one satellite bag with SAGM (Saline-Adenine-Glucose-Mannitol) solution for Red Blood Cell preservation. A transfer bag for platelets conservation for 5 days is incorporated.
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
92-43-764-50 350ml
90-47-764-50 450ml
90-45-764-50 500ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in150ml, 300ml,
and 400ml
500
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Standard SetCapacity
91-15-364-00 150ml
91-20-364-00 200ml
Two entry port and a singlelead with a transfer spike
91-30-364-01 300ml
91-50-364-00 500ml
91-60-364-00 600ml
91-91-364-00 1000ml
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
92-33-764-50 350ml
90-37-764-50 450ml
90-35-764-50 500ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in150ml, 300ml,
and 400ml
JMS Triple Blood Bag For whole blood collection and separation of 3 di�erent blood components (Red Blood Cells, Plasma and a bu�y-coat that comprise of Leukocytes and Platelets), obtained through the process of centrifugation and extraction. JMS T-Bex System comprise of a specially con�gured primary bag containing anticoagulant CPD solution and one satellite bag with SAGM (Saline-Adenine-Glucose- Mannitol) solution for Red Blood Cell preservation.
Transfer Bag
Pg 19
JMS Quadruple BloodBag T-Bex
CPD-SAGM Solution
For whole blood collection and on-line �ltration of whole blood components (Red Blood Cells andPlasma), obtained through the process of centrifugation and extraction.
JMS Dockable Red CellLeuko-Filtration System
Leukoreduction & Storage Set for Red Cell. For dockable of a pack of red cell and provide an on-line
�ltration of the red cell.
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-44-764-88 450ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 300ml
and 400ml
Available in16G and 17G
JMS Quadruple Blood Bag CPD-SAGM Solution
For whole blood collection and on-line �ltration of whole blood components (Red Blood Cells andPlasma), obtained through the process of centrifugation and extraction.
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-44-764-77 450ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 300ml
and 400ml
Available in16G and 17G
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
90-88-000-01 450ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 300ml
and 400ml
Available in16G and 17G
Pg 20
Catalog Number Standard Set
04-35-061-00 With Venous Needle
04-35-061-01 Without Venous Needle
Product Con�gurationTransfusion Set
JMS Transfusion Set Type-5 JMS Transfusion Set Type-5 is designed for administration of whole blood and red cells orplasma from Blood Bag. Consist of a double chamber; the upper chamber with a blood �lterand the lower chamber with a drip ori�ce. This con�guration assures full utilization of the�lter of the upper chamber and easy observation of drops in the lower.
JMS Transfusion Set Type-Y JMS Transfusion Set Type-Y is designed for simultaneous or alternate administration of bloodand solution. The spike is designed to �t both the blood bags and solution bag.
JMS Transfusion Set with Buret JMS Transfusion Set with Buret for small volume blood transfusion is especially useful inneonatal, premature babies and pediatrics. The buret (volumetric chamber) is graduated in1ml interval to allow precise blood volume control.
Catalog Number Standard Set
04-90-061-00 With Venous Needle
04-35-090-01 Without Venous Needle
Catalog Number Standard Set
04-80-061-80 With 100ml Buret
04-80-062-00 With 150ml Buret
Pg 21
Product Con�gurationPlatelet Storage Bag
Plasmapheresis System
JMS Platelet Storage Bag A new generation of container with high oxygen permeability to maintain the aerobicmetabolism of Platelets. The UPX-80 PVC material is designed to achieve an optimum PHbalance during storage.
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
Type Catalog Primary Bag Satellite BagNumber Capacity Capacity
Single Bag 90-70-130-00 1000ml Available in100mlDouble Bag 90-70-230-00 1000ml
JMS Singleand Multiple Plasmapheresis For Plasmapheresis and collection of comparably larger volume of plasma. After centrifugation,
plasma is extracted and the red cells returned to the donor through a blood returning port.Many important therapeutic products are derived from plasma including albumin and plasmaprotein fraction. JMS Plasmapheresis’s systems are designed in Single Plasmapheresis (2 Bags)and Multiple Plasmapheresis (4 or 6 bags) Pack with maximum utilization of small donor pool.The primary bag contains anti-coagulant CPD solution.
Catalog Number Primary Bag Donor NeedleCapacity Guage Size
90-12-964-01 250ml Super-Thin-Walled
90-13-964-01 350ml Ultra Sharp Needle
90-17-964-01 450ml Available in
90-15-964-01 500ml 16G or 17GOptional Features
*With or without accessories, T&T or T&B BSB, iBSP with or without lid
Catalog Number Primary Bag Satellite Bag Donor NeedleCapacity Capacity Gauge Size
92-56-364-01 400ml
90-68-364-01 500ml
90-66-364-01 600ml
Optional Features
*With or without accessories, T&T or T&B BSB, NP, iBSP with or without lid
Availablein 16G or 17G
Available in300ml, 400ml,
and 500ml
Pg 22
CompleteBlood Banking Accessories
JMS o�ers a full and complete range of blood banking accessories to complement the use ofour blood bag products. With our state of the art research & development facilities we striveto o�er unique and innovative solutions to meet the diversifying needs of healthcare market.
We innovate for a better tomorrow
Hemoscale Hand SealerTransfusionChair
DualPress
Heavy DutyHemosealer
PortableHemosealer
PlasmaExtractor
PlateletIncubator
CompleteBlood Banking Accessories
Pg 23
JMS Singapore is a global-oriented world class manufacturing plant, providing state-of-the-art healthcare products in Infusion Therapy, Dialysis System, Blood Management, Equipment & Accessories.
Global market leader with worldwide distribution network
JMS North America CorporationMain Office22320 Foothill BoulevardSuite 350Hayward, CA 94541, USA
Tel : +510-888-9090Fax: +510-888-9099
Eastern Region Office480 Sawgrass Corporate ParkwaySuite 120Sunrise, FL 33325 USA
Tel : +954-689-9280Fax: +954-689-9289
Bionic Medizintechnik G.m.b.HMax-Planck, Str. 21, 61381,Friedrichsdorf, Germany
Tel: +49-6172-7576-0Fax: +49-6172-7576-10
JMS Dalian Medical Supply Co., Ltd25 Huanghaixi RoadDalian Economic and TechnicalDevelopment Zone, Dalian,People’s Republic of China
Tel : +86-411-7613414Fax: +86-411-7612300
PT JMS BatamJI.Beringin Lot 211-212Kawasan Industri BatamindoMukakuningBatam 29433, IndonesiaTel: +62-770-611-805Fax: +62-770-611-806
JMS CO., LTDTokyo HeadquartersShin-Minamiohi Building1-13-5 MinamiohiShinagawa-kuTokyo 140-0013Tel : +81-(0)3-6404-0600Fax: +81-(0)3-6404-0610
Hiroshima Headquarters12-17 Kako-machi, Naka-kuHiroshima-shi, Hiroshima-ken730-8652
Tel : +81-(0)82-243-5844Fax: +81-(0)82-243-5997
JMS (K) Medical Supply Co., Ltd547 Gasan-Dong,Geumcheon-guRepublic of Korea
Tel : +82-2-856-0518Fax: +82-2-862-4598
JMS Singapore Pte Ltd440 Ang Mo Kio Industrial Park 1,Singapore 569620
Tel : +65-6457-1144Fax: +65-6459-9564
A s i a N o r t h A m e r i c a
E u r o p e
Distributor
For more information please contactus or your local distributor
Copyright ©2010 JMS North America Corporation.All rights reserved.
BRO/BB-E/001_R1