Carmel Resins Products for the Corrugated Industry Carmel Resins.
BioPro IEX Resins - Achrom€¦ · BioPro Ion Exchange Resin BioPro ion exchange resins are...
Transcript of BioPro IEX Resins - Achrom€¦ · BioPro Ion Exchange Resin BioPro ion exchange resins are...
BioProIEX Resins
Resin
Downstream
Purification
2
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
BioPro:Designed forbioseparations
3
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Guide to IEX Media Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Solutions for Capture Processes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Solutions for Intermediate Purification and Polishing . . . . . . . . . . . . . . . . . . . . . . 15
Purification of Monoclonal Antibodies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Ion exchange (IEX) media is widely used in the analysis and purification of biomole-
cules. For instance, in industrial-scale protein production processes, IEX media are often
used for initial product capture and intermediate purification stages as well as the final
polishing steps. Using reversible charge-charge interactions offers several advantag-
es over in comparison to other chromatographic methods, e.g. high capacity and fast
throughput.
BioPro and BioPro SmartSep form a series of ion exchange resins specifically designed
for biochromatography. It is available as a strong anion exchanger (BioPro Q) and a
strong cation exchanger (BioPro S). The media is based on a hydrophilic polymer ma-
trix, with a particle size of 10 µm, 20 µm, 30 µm and 75 µm. BioPro resins with a 75 µm
particle size are especially suited for the initial capture step while the BioPro SmartSep
10 µm, 20 µm, 30 µm are the ideal choices for the intermediate purification and polish-
ing processes. BioPro is manufactured in lot sizes up to 450 L.
Introduction
BioPro
Ion Exchange Type Strong anion exchanger, strong cation exchanger
Particle Size 75 µm
BioPro SmartSep
Ion Exchange Type Strong anion exchanger, strong cation exchanger
Particle Size 10 µm, 20 µm, 30 µm
BioPro series media provide:
• Solutions for challenging separations
• Increased productivity
• Reduced processing costs
• Worldwide availability, even for large quantities
• Full compliance with FDA regulations
5
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Guide to IEX Media Selection
Selection of the media chemistry
The separation with IEX Media is based on the net surface charge of the analytes in rela-
tion to the pH of the surroundings. The theory for selection of an anion exchanger or a
cation exchanger is shown in the figure below.
+
–
Net
Cha
rge
of P
rote
in
2 4 6 8 10 12
If the system pH is below PI,select cation exchanger
If the system pH is above PI,select anion exchangerIs
oele
ctric
poi
nt (P
I)
pH
C N CH3
H
H
CH3
CH3 +
–
BioProQA
BioProSP
Strong anion exchanger
Strong cation exchanger
N.B.: Fully porous particles
BioPro series products are polymeric ion exchange media for the purification of biologi-
cal molecules. They are available in Q and S chemistries.
Cn SO3
H
H
6
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Guide to IEX Media Selection
YMC IEX Media
Capture
Intermediate purification
Polishing
BioPro 75 µm
BioPro SmartSep10, 20, 30 µm
BioPro SmartSep10, 20, 30 µm
The selection of the particle size of the media depends on the purification purpose.
A purification strategy usually includes three parts:
• initial product capture
• intermediate purification stages
• the final polishing step
Each step has correspondingly different targets and requirements for the chromatogra-
phy media. The capture step aims at isolating and concentrating the targets. It requires
that the media have high binding capacity even at high flow rate and easy scale-up steps.
The intermediate purification is for removing the bulk impurities while the polishing step
is for removing all trace impurities. The corresponding media should exhibit high resolu-
tion and low non-specific adsorption.
IEX resins are used during the whole process from the capture to the final polishing. Bio-
Pro media are designed for capture step of biopharmaceuticals and BioPro SmartSep me-
dia are for intermediate purification and polishing steps of biopharmaceuticals.
7
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Specifications
BioPro SeriesBioPro
SmartSepQ10
BioProSmartSep
Q20
BioProSmartSep
Q30
BioPro SmartSep
S10
BioProSmartSep
S20
BioProSmartSep
S30
Ion exchange type strong anion exchanger strong cation exchanger
Charged group -R-N+(CH3)3 -R-SO3-
Matrix Hydrophilic polymer beads
Pore size Porous
Compression factor 1.05 - 1.15
Particle size 10 µm 20 µm 30 µm 10 µm 20 µm 30 µm
Pressureresistance
Regular use:3 MPa
Max.: 4 MPa
Regular use:2 MPa
Max.: 3 MPa
Regular use:3 MPa
Max.: 4 MPa
Regular use:2 MPa
Max.: 3 MPa
Typical flow rate 200-1000 cm/hrMax. 2000 cm/hr
Ion-exchange capacity min. 0.08 meq/ml-resin min. 0.08 meq/ml-resin
Dynamic binding capacity
min. 100 mg/ml-resin(BSA)
min. 100 mg/ml-resin(lysozyme)
Regulatory support file available under non-disclosure agreement. Customised material available on request.Used in validated cGMP-manufacturing processes. DMF registered with FDA.
BioPro Series BioProQ75
BioProS75
Ion exchange type strong anion exchanger strong cation exchanger
Charged group -R-N+(CH3)3 -R-SO3-
Matrix Hydrophilic polymer beads
Pore size Porous
Compression factor 1.05 - 1.15
Particle size 75 µm
Pressure resistance 0.3 MPa
Typical flow rate 200-1000 cm/hrMax. 2000 cm/hr
Ion-exchange capacity min. 0.10 meq/ml-resin
Dynamic bindingcapacity
min. 160 mg/ml-resin(BSA)
BioPro SmartSep for intermediate purifications and polishing
BioPro for Capture
8
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Solution for your capture process:BioPro 75 µm
9
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
BioPro Ion Exchange Resin
BioPro ion exchange resins are designed for the capture step of peptides, proteins and
nucleotides on the laboratory and industrial scales. The materials offer high dynamic
binding capacity, together with low non-specific adsorption and excellent recovery.
The narrow particle size distribution and the low operating pressure enable the materi-
als to work even at high flow rates.
• Excellent dynamic binding capacity (DBC)
• Low non-specific adsorption and high recovery
• High capacity with low operating pressure even at high flow rates
• Full compliances with GMP requirements
• Short delivery for industrial-scale quantities
• Reduced processing costs
Scale up and availability
The BioPro series includes prepacked columns with 5 µm porous and non-porous res-
ins for fast analysis, and bulk materials up to 75 µm porous beads for purification and
capture. The 5 µm porous type and bulk media have similar retention selectivity which
allows for predictable scale-up process. The bulk media are available in quantities up to
several thousand litres.
Mission Statement
YMC will never knowingly change any product that is being used in a validated
production process or validated analytical method.
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
10 High Dynamic Binding Capacity (DBC)
High binding capacity and high recovery
The porous versions of BioPro show high dynamic binding capacity and excellent recov-ery, making them useful for preparative separations of proteins and antibodies.
Column: BioPro S75, 50 x 5.0 mm IDSample: 1.0 mg/ml Lysozyme in equilibration bufferEluent: A) 20 mM Glycine-NaOH (pH 9.0) B) 20 mM Glycine-NaOH (pH 9.0) containing 0.5 M NaClDetection: UV at 300 nm
High sample loading at high flow rates has been determined by the dynamic binding capacity of an ion exchange resin.The dynamic binding capacity of BioPro is excellent even at high flow rates. When com-pared to similar competitor products it consistently exhibits a higher dynamic binding capacity. This results in higher sample loading in your preparative processes.
——: BioPro S75 (75 µm)——: Tosoh Gigacap S-650M (50 ~ 100 µm)——: GE Capto S (90 µm)
BioPro S75 Particle BioPro S75 Particle
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
11Excellent Performance – Applications
Two step purification of IgY to produce reference standard material from crude egg yolk extract*
min0 5 10 15 20
Column
Eluent
Flow rateTemperatureDetection
: YMC-Pack Diol-200 300 X 4.6 mm ID : 0.1 M KH2PO4-K2HPO4 (pH 6.9) containing 0.2 M NaCl: 0.23 ml/min: ambient: UV at 280 nm
A090826A
A090824J
A090826E
IgY
Purity <15%
Purity 53%Recovery 40%
Purity >99%Recovery 23%
Crude extract
SEC fraction
SEC analysis of crude and purified fraction
1 2 3 4 5
205
116978066
5545
30
2114
6.5
MW(kDa)
SDS-PAGE1 2 3 4 5
97
66
45
29
2014
MW(kDa)
Non-reduced SDS-PAGE Lane1: Marker
(containing SDS)2: Crude extract3: IEC fraction4: SEC fraction5: Standard IgY
IgY
H chain
L chain
SDS-PAGE analysis of crude and purified fraction
IEX fraction
IEX fraction
high
achievement
min
mV
0 5 10 15 20 25 30
0
25
50
75
100
YMC-Pack Diol-200, 5 µm
SampleColumnEluent
Flow rateTemperatureDetectionInjection
: Fraction from capture purification by IEC: YMC-Pack Diol-200, 5 µm, 300 X 8.0 mm ID: 0.1 M KH2PO4-K2HPO4 (pH 6.9) containing 0.2 M NaCl: 0.7 ml/min (180 cm/hr): ambient: UV at 280 nm: 1 ml (approx. 0.45 mg IgY)
min
mV
0 10 20 30 40 50 60
0
100
200
300
400
500 SampleColumnEluent
Flow rateTemperatureDetectionInjection
: Crude extract from egg yolk
: A) 20 mM Tris-HCl (pH 8.1) B) 20 mM Tris-HCl (pH 8.1) containing 0.5 M NaCl 10% B (0-15 min), 30% B (15-30 min), 90% B (30-40 min): 0.5 ml/min (180 cm/hr): ambient: UV at 280 nm: 1 ml (approx. 20 mg protein)
Crude extract is the supernatant after precipitation of the lipids and lipoproteins from egg yolk.
Crude extract from egg yolk containing IgY IgY (MW 170 kda)
L chain (MW 23 kda)
H chain (MW 65 kda)
Step 1: Capture purification by IEX Step 2: Final purification by SEC
* Application data by courtesy YMC Co., Ltd.
BioPro Q75, 75 µm
: BioPro Q75, 75 µm, 50 x 4.6 mm ID
Gradient :
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
12Test protocol
Separation of standardproteins
Determination of DBCand recovery
CIP with 1.0 M NaOH(5 CV at 400 cm/hr)
Cleaning-In-Place (CIP) Performance
Column: BioPro S75, 50 x 5.0 mm ID
Conditions for standard protein separationEluent: A) 20 mM NaH2PO4-Na2HPO4 (pH 6.8) B) 20 mM NaH2PO4-Na2HPO4 (pH 6.8) containing 0.5 M NaClGradient: 0-100% B (0-60 min, Linear)Flow rate: 0.59 ml/min (180 cm/hr)Temperature: 25 °C Detection: UV at 220 nmInjection: 24 µl
Conditions of DBC determinationEluent: A) 20 mM Glycine-NaOH(pH 9.0) B) 20 mM Glycine-NaOH(pH 9.0) containing 0.5 M NaClFlow rate: 2.62 ml/min (800 cm/hr)Sample: 1.0 mg/ml Lysozyme in equilibration bufferTemperature: ambient (25 °C)Detection: UV at 300 nmDBC determined at 10% breakthrough.
CIP Performance
DBC and recovery*Separation of standard proteins*
BioPro is well suited for alkaline CIP procedures. The dynamic binding capacity (DBC) and the selectivity are unaffected by 20 cycles of CIP with 1.0 M NaOH. The recovery of proteins is maintained at 100%, which demonstrates the absence of nonspecific adsorption of proteins by this hydrophilic resin.
* Application data by courtesy YMC Co., Ltd.
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
13Stability in Alkaline Conditions*
BioPro Q75
Immerse gel inNaOH (1 M)(2-6 hours)
Flush withNaOH (1 M)
0.2 ml/min, 2 hours
Columnperformance
Columnperformance
Packed into50 x 5.0 mm ID
Flush with waterto remove NaCl
repeatPacked into50 x 5.0 mm ID
Exposure to 1 M NaOH solution
Exposure time (h)
tR (T
ryps
in in
hibi
tor)
min
44
42
40
38
36
34
32
300 1 2 3 4 5 6
Flushing with 1 M NaOH solution
NaOH (CV)
0 20 40 60 80
Column performance test conditions
Eluent: A) 20 mM Tris-HCl (pH 8.1) B) 20 mM Tris-HCl (pH 8.1) containing 0.5 M NaClGradient: 10 - 80% B (0-60 min)Flow rate: 0.5 ml/min
Stability towards alkaline conditions is essential for efficient sanitizing procedures in a highly regulated environment.BioPro media show excellent tolerance towards challenging alkaline conditions. Stabil-ity testing demonstrates that 0.1M NaOH is suitable for long term storage of BioPro. The high chemical stability of BioPro resins allows effective cleaning with alkaline solution and the longevity this material ensures efficient and economic purifications.
Temperature: 25 °CDetection: UV at 220 nmSample: Trypsin inhibitor, TransferrinInjection: 40 µl
* Application data by courtesy YMC Co., Ltd.
Solution for intermediatepurification and polishing:
BioPro SmartSep
application
separation
elution
% salt
t
+ + ++++
++++++
- –––
– – – –––
––––––
+ ++ ++++++
++
% s
alt
conc
entr
atio
n
% salt
t
weakly negativecharged
highly negativecharged
-
---- --
--weakly positive
chargedhighly positive
charged
++–
--–
–
+
++
++–----–
– -- --–--
--–
–
–
+ + ++++
++++++
-- ------------ --
– –– –
– – –
+ + ++++
++++++ -- ---- ------
-- --
– –– –
– – –– –
----
-- + ++ + ++++
++
+++
++ ++
++
++ ++
+
– – – –––
––––––
++++ ++
++++++ ++ ++
++
+++
+ + ++ ++ +
– – – –––
––––––++
++ ++ ++
++++ ++ ++ ++ ++ ++
+++
+ + ++ ++ +
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
15BioPro SmartSep Ion Exchange Resin
BioPro SmartSep 10 µm, 20 µm and 30 µm resins are the ideal choices for the intermedi-
ate purification and polishing processes. With its small particle size, BioPro SmartSep
10 µm provides extraordinary high resolution. BioPro SmartSep 20 µm and 30 µm have
been widely used in industrial production process.
• Solution for challenging separations
• Increase productivity
• Reduced processing costs
• Short delivery time for industrial-scale quantities
• Full compliance with GMP regulations
Examples of possible preparative applications of YMC BioPro SmartSep resins are:
• Antibody purification
• Protein purification
• Peptide purification
• Oligonucleotide purification
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
16 High Dynamic Binding Capacity (DBC)
Comparison of the Performance of BioPro SmartSep and Competitors´ Products
in the Purification of Lysozyme , Insulin and Polyclonal lgG
= BioPro SmartSep S30= TSKgel SP-3PW= GE Source 30S
Comparison of DBC for lysozyme (left) and column pressure (right) at different flow rate.
0,25
0,2
0,15
0,1
0,05
00 200 400 600 800 1000 1200
Linear flow rate (cm/hr)
Pres
sure
(MPa
)
130
120
110
100
90
80
70
60
50
40
30
DBC
(mg/
mL-
resi
n)
0 200 400 600 800 1000 1200
Linear flow rate (cm/hr)
BioPro SmartSep shows considerably higher DBC across a wide range of linear velocity. A high DBC at flow rates of up to 1,000 cm/hr can reduce process time and increase productivity.
Column: 50 x 5.0 mm IDEquilibration buffer: 20 mM Glycine-NaOH (pH 9.0)Linear velocitiy: 200-1,000 cm/hr (0.66 mL/min-3.27 mL/min)
Pressure monitoring
= BioPro SmartSep S30= TSKgel SP-3PW= GE Source 30S
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
17High Dynamic Binding Capacity (DBC)
Comparison of BioPro SmartSep S30 and competitor´s DBC for human polyclonal lgG at different flow rates.
BioPro SmartSep shows considerably higher DBC across a wide range of linear velocity. A high DBC at flow rates of up to 1,000 cm/hr can reduce process time and increase productivity.
Column: 50 x 5.0 mm IDEquilibration buffer: 20 mM Glycine-NaOH (pH 9.0)Linear velocitiy: 200-1,000 cm/hr (0.66 mL/min-3.27 mL/min)
BioPro SmartSep S30 particles
18
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Comparison of BioPro SmartSep S30 and competitor s DBC for lysozyme, insulin and poly-clonal lgG.
BioPro SmartSep shows higher dynamic binding capacity for both small peptides and large proteins.
Column: 50 x 5.0 mm IDFlow rate: 400 cm/hr (1.32 mL/min)Temperature: 25 °C
120
100
80
60
40
20
0
DB
C (m
g/m
L ge
l)
Insulin(MW : 5,800)
Lysozyme(MW : 14,300)
Human Polyclonal lgG(MW : 150,000)
BioPro SmartSep S30
TSKgel SP-3PW
GE SOURCE 30S
High Dynamic Binding Capacity (DBC)
19
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
High Resolution and Recovery
Recovery (> 98% Purity)
Ribonuclease A Cytochrome c Lysozyme Total
BioProSmartSep S30
90.5% 81.5% 99.3% 90.7%
TSKgel SP-3PW 74.2 % 54.4 % 99.5 % 76.9 %
GE Source 30S 87.2 % 76.0 % 99.5 % 87.8 %
Column: 50 x 5.0 mm IDEluent: A) 20 mM NaH2PO4-Na2HPO4 (pH 6.8) B) 20 mM NaH2PO4-Na2HPO4 (pH 6.8) containing 0.5 M NaClGradient: 0-100% B, 30 column volumesFlow rate: 1600 cm/hr (5.23 mL/min)Temperature: 25°C
Comparison of resolution with competitors’ materials.
BioPro SmartSep bulk media offer a perfect solution for challenging separations. With the
high binding capacity and recovery, the media allow high-throughput purifications and
increased productivity. Easy elution of target compounds improves the whole process.
TSKgel SP-3PW (Porous S type, 30 µm)
BioPro SmartSep S30 (30 µm)
GE Source 30S (Porous S type, 30 µm)
Detection: UV at 220 nmInjection: 20 mL (30 mg Proteins)Sample: 1. Ribonuclease A (0.5 mg/mL) 2. Cytochrome c (0.5 mg/mL) 3. Lysozyme (0.5 mg/mL)
BioPro SmartSep S30 maintains its high resolution and high sample loading ability even at 1600 cm/hr and under high loading condition (30 mg/mL). It shows up to 50% higher recovery for specific target compounds compared to the competitor’s materials. These features of the BioPro SmartSep material indicate the possibility of cost savings for your purification.
up to50% higher
recovery
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
20 Low Backpressure
Column: 50 x 5.0 mm ID (upper graph) 350 x 15 mm ID (bottom graph)Eluent: water
Upper pressure limit(SmartSep 20/30 µm)
BioPro series media demonstrate low backpressures over a wide range of flow rates. Less than 1.0 MPa backpressure is generated at a flow rate of 2000 cm/hr with bed length of 50 mm. The pressure-flow curve is shown in the figure above. The resins with particle size of 30 µm allow high flow rates even with low pressure equipment.
50 x 5.0 mm ID
350 x 15 mm ID
— BioPro SmartSep 20 µm— BioPro SmartSep 30 µm— BioPro 75 µm
— BioPro SmartSep 20 µm— BioPro SmartSep 30 µm— BioPro 75 µm
Upper pressure limit for regular use(SmartSep 20/30 µm)
Upper pressure limit(BioPro 75 µm)
21
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Scalability across All Particle Sizes
BioPro SmartSep materials have the same separation characteristics across the different
particle sizes.
Column: 50 x 5.0 mm ID Eluent A: 20 mM NaH2PO4-Na2HPO4
(pH 6.8)Eluent B: Eluent A containing 0.5 M NaClGradient: 0-100%B (0-60min)Flow rate: 0.59 mL/min (180 cm/hr)Temperature: 25°CDetection: UV at 220 nm
1. Transferrin2. Trypsin inhibitor
Column: 50 x 4.6 mm ID Eluent A: 20 mM Tris-HCl (pH 8.1)Eluent B: Eluent A containing 0.5 M NaClGradient: 10-80% B (0-60min)Flow rate: 0.5 mL/min (180 cm/hr)Temperature: 30°CDetection: UV at 220 nm
1. Ribonuclease A2. Cytochrom c3. Lysozyme
The consistent performance across all particle sizes is advantageous for seamless method transfer between particle sizes.
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
Purification ofMonoclonal Antibodies
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
23Purification of Monoclonal Antibodies
For purification of monoclonal antibodies, high demands are required from the separat-ing medium. Factors influencing the binding characteristics of lgG are pH, linear veloc-ity and salt concentration (conductivity) at the time when the sample is loaded onto the column. A purification of anti-human TNF-a monoclonal antibody was performed using BioPro SmartSep and the influence of factors such as pH, linear velocity and salt concentration were studied. The BioPro SmartSep material shows good performance in all the tests.
Comparison of the Performance of BioPro SmartSep and Competitors´ Products in the Purification of anti-human TNF-a monoclonal antibody
Column: 50 x 5.0 mm IDEluent: A) 20 mM citric acid-NaOH (pH 5.3) B) Eluent A containing 0.5 M NaClGradient: 0-100% B (0-30 CV)Flow rate: 180 cm/hr (0.59 mL/min)Temperature: ambientDetection: UV at 280 nmSample: Anti-human TNF-a monoclonal antibody (after affinity chromatography)lgG Load: 0.1 mgInjection: 0.25 mL
pH 5.3
rProtein A
Anti-human TNF-a monoclonal antibody
Formulation of the humanized anti-human TNF-a monoclonal antibody
pH 6.0
rProtein A
Anti-human TNF-a monoclonal antibody
BioPro SmartSep S30
GE Source 30S
Tosoh TSKgel SP-3PW
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
24 Purification of Monoclonal Antibodies
Influence of pH, linear velocity and salt concentration on the purification of IgG
using BioPro SmartSep
Column: 50 x 5.0 mm IDEluent: A) 20 mM citric acid-NaOH buffer (pH 5.3 or 6.0) B) Eluent A containing 0.5 M NaClFlow rate: 200 - 800 cm/hr (0.66-2.62 mL/min)Temperature: ambient (25°C)Detection: UV at 280nmSample: 1.5 mg/mL human polyclonal IgG in equilibration buffer
Experimental conditions
pH: 6.0 vs. 5.3Linear velocity: 200 - 800 cm/hrSalt concentration: 0 - 50 mM NaCl
Influence of pH
pHDBC (mg/mL-resin, 10% breakthrough)
pH 5.3 pH 6.0
BioPro SmartSep S30 110 103
Tosoh TSKgel SP-3PW (30 μm) 61 64
GE Source 30S (30 μm) 58 58
5 6 7pH
120
110
100
90
80
70
60
50
40
30
20
10
0
DBC
(mg/
mL-
resi
n)
= BioPro SmartSep S30= TSKgel SP-3PW (30 µm)= GE Source 30S (30 µm)
High binding capacities are achieved regardless of elution of pH. Therefore, milder eluting conditions for IgG can be selected to protect the product purity.
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
25Purification of Monoclonal Antibodies
Influence of salt concentration
DBC (mg/mL-resin, 10% breakthrough)
pH 5.3
NaCl concentration 0 mM 25 mM 50 mM
Conductivity 1.36 mS/cm 4.14 mS/cm 6.8 mS/cm
BioPro SmartSep S30 107 97 50
Tosoh TSKgel SP-3PW (30 μm) 64 55 27
GE Source 30S (30 μm) 58 49 19
BioPro SmartSep has a higher salt concentration tolerance. This simplifies the desalt-ing process after Protein A chromatography and will help to shorten the production process.
= BioPro SmartSep S30= TSKgel SP-3PW (30 µm)= GE Source 30S (30 µm)
Flow rate: 200 cm/hr (0.66 mL/min)Sample: 1.5 mg/mL human polyclonal lgG in equilibration buffer containing 0.25, 50 mM NaCl
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
26 Purification of Monoclonal Antibodies
Influence of linear velocity
Linear velocityDBC (mg/mL-resin, 10% breakthrough)
200 cm/hr 400 cm/hr 800 cm/hr
BioPro SmartSep S30 110 93 84
Tosoh TSKgel SP-3PW (30 μm) 61 42 26
GE Source 30S (30 μm) 58 41 23
BioPro SmartSep maintains higher binding capacity values over a wider range of linear
velocities. This will increase product throughput for the purification process without
any loss of efficiency.
= BioPro SmartSep S30= TSKgel SP-3PW (30 µm)= GE Source 30S (30 µm)
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
27Conclusions
BioPro SmartSep materials meet the highest demands for the purification of mono-
clonal antibodies. High binding capacity is achieved regardless of elution of pH, linear
velocity or salt concentration. This allows purification processes to be carried out more
efficiently.
• Higher throughput with no loss of efficiency
• Simplification of desalting processes
• Reduced processing costs
• Short delivery time for industrial-scale quantities
• Full compliance with GMP regulations
Purification of Monoclonal Antibodies
Purified monoclonal antibody lgG1
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
28 Screening Kits and Test Samples
Screening kits and bulk samples for media selection and method development
YMC offers a number of ion exchange screening kits based on 1 mL or 5 mL columns
and also free bulk media samples for testing. This provides a significant advantage and
efficiency in media screening and purification method development.
1 ml Type (26 x 7.0 mm ID)
• Resin screening
• Purification method development
5 ml Type (26 x 15.6 mm ID)
• Purification method development
• Loadability studies
Please contact us to order your free bulk media samples for testing.
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
29Ordering Information for BioPro Resin
Strong anion exchanger: BioPro Q
Strong cation exchanger: BioPro S
Product Particle Size Code
Pack Sizes*
50 ml 250 ml 1 L 5 L 10 L 20 L
BioPro SmartSep Q10 10 µm QSA0S10 ✔ ✔ ✔ ✔ ✔ ✔
BioPro SmartSep Q20 20 µm QSA0S20 ✔ ✔ ✔ ✔ ✔ ✔
BioPro SmartSep Q30 30 µm QSA0S30 ✔ ✔ ✔ ✔ ✔ ✔
BioPro Q75 75 µm QAA0S75 ✔ ✔ ✔ ✔ ✔ ✔
* Larger or customised pack sizes are available on request.
Product Particle Size Code
Pack Sizes*
50 ml 250 ml 1 L 5 L 10 L 20 L
BioPro SmartSep S10 10 µm SSA0S10 ✔ ✔ ✔ ✔ ✔ ✔
BioPro SmartSep S20 20 µm SSA0S20 ✔ ✔ ✔ ✔ ✔ ✔
BioPro SmartSep S30 30 µm SSA0S30 ✔ ✔ ✔ ✔ ✔ ✔
BioPro S75 75 µm SPA0S75 ✔ ✔ ✔ ✔ ✔ ✔
Availability
• Large production capacity for YMC’s IEX resin. • Short delivery time even for large quantities.• Full compliance with GMP requirements.
Ordering Information for Preparative Screening Kits
Preparative screening kitsProduct name* Particle Size Specification Column volume Product number
BioPro Q75 75 µm5 / pack 1 mL BPQAA0S75-01PK
5 / pack 5 mL BPQAA0S75-05PK
BioPro SmartSep Q30 30 µm5 / pack 1 mL BPQSA0S30-01PK
5 / pack 5 mL BPQSA0S30-05PK
BioPro S75 75 µm5 / pack 1 mL BPSPA0S75-01PK
5 / pack 5 mL BPSPA0S75-05PK
BioPro SmartSep S30 30 µm5 / pack 1 mL BPSSA0S30-01PK
5 / pack 5 mL BPSSA0S30-05PK
* Other screening kits are available on request
Regulatory support file available under non-disclosure agreement. Used in validated cGMP-manufacturing processes. Customised material available on request. DMFregisterd with FDA.
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
30 YMC Glass Columns
YMC Pilot columns Inner diameter 100 mm, 140 mm and 200 mm, others on request
Two standard glass lengths 500 or 850 mm, others on request
Variable bed length (standard 100-400 mm or 450-750 mm)
Column volumes: up to 24 L
Pressure resistance: 5 - 10 bar
Optional accessories, e.g. manometer, bubble traps, stop valves, packing devices
Manufactured to customer‘s demands
Also available as SR version = Solvent Resistant
YMC ECO columns
Pressure resistance: 5 - 30 bar
Inner diameter: 10 - 80 mm
Column length: 120 - 1000 mm
Variable bed length
Column volumes: 0 - 5 L
Available as AB (aqueous buffer versions) SR (solvent resistant versions)
YMC ECOPLUS column
Pressure resistance: 30 - 80 bar
Inner diameter: 5 - 50 mm
Column length: 125 - 500 mm
Variable bed length
Column volumes: 0 - 950 mL
Available as AB (aqueous buffer versions) SR (solvent resistant versions)
Ideally suited for use with BioPro Prep stationary phases:Glass columns made by YMC for biochromatography
Schöttmannshof 19 · D-46539 Dinslaken · Phone +49 (0) 20 64 427-0 · Telefax +49 (0) 20 64 427-222E-Mail: [email protected] · www.ymc.de
31
The Selectivity CompanyThe Selectivity Company
YMC*Gel HG-seriesHigh grade silica phases for preparative HPLC
www.ymc.de
YMC*Gel HG-series brochure
General purpose preparative phases based on a high grade silica base.
Available as silica or with C18, C8, C4, C1,phenyl, cyano, amino or diol bonding.
Particle size: 10 µm, 15 µm, 20 µm or 50 µmPore size: 12 nm, 20 nm or 30 nm(Other particle and pore sizes on request)
YMC-Triart Prep
Hybrid silica phase, stable between pH 2.0 - 10.0.
Available with C18 and C8 bonding.
Particle size: 10 µm, 15 µm or 20 µmPore size: 12 nm or 20 nm(Other particle and pore sizes on request)
YMC Solutions for Preparative Chromatography
YMC has more than 30 years experience in the manufacture of stationary phases for preparative liquid chromatography.
BioPro series products are polymeric ion exchange resins for the purification of biological mol-ecules. They represent one part of the three part YMC-Prep portfolio: silica, hybrid silica and polymer media.
Further information on YMC*Gel silica and YMC-Triart Prep products can be found in the follow-ing brochures:
GE is a trademark of General Electric Company.Tosoh is a trademark of Tosoh Bioscience LLC.
Your local distributor:
BioPro IEX Resins 09/2017_EN_V1.3
CO., LTD.YMC Karasuma-Gojo Bld. 284 Daigo-cho,Karasuma Nishiiru Gojo-dori Shimogyo-ku,Kyoto 600-8106 JapanTEL. +81(0)75-342-4515, FAX +81(0)75-342-4550www.ymc.co.jp
America, Inc.941 Marcon Boulevard Suite 201Allentown, PA18109 USATEL. +1-610-266-8650, FAX +1-610-266-8652www.ymcamerica.com
Europe GmbHSchöttmannshof 19D-46539 DinslakenGermanyTEL. +49(0)2064/427-0, FAX +49(0)2064/427-222www.ymc.de
India Pvt. Ltd.A-154-155, 1st Floor, Eros Boulevard Hotel Crown Plaza, Plot No.13-B District Centre Mayur Vihar Phase-I New Delhi-110091 IndiaTEL. +91-11-45041601; 45041701, FAX +91-11-45041901www.ymcindia.com
Co., Ltd. Shanghai Rep. OfficeFar East International Plaza A2404No. 319 Xianxia Road, Shanghai 200051P.R. ChinaTEL. +86-21-6235-1388, FAX +86-21-6235-1398www.ymcchina.com
Korea Co., Ltd.310 Woolim W-City, 9-22 Pangyo-ro 255, Beon-gil, Bundang-gu, Sungnam-si, Gyeonggi-do13486 KoreaTEL. +82-31-716-1631, FAX +82-31-716-1630www.ymckorea.com
Taiwan Co., Ltd.1F., No. 76, Ln. 191, Sec. 3, Minquan E. Rd.,Songshan Dist., Taipei City 105,Taiwan (R.O.C.)TEL. +886-2-2716-0840, FAX +886-2-2716-2090www.ymctaiwan.com
Singapore Tradelinks Pte. Ltd.29 Mayo Street #03-03,Singapore 208315 TEL. +65-9023-7617www.ymc.sg