Biological and Chemical Detection in the Brewing Industry
Submitted by:
David Jones
![Page 2: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/2.jpg)
Brewing Process• Brewing bacteriology was born when
microorganisms responsible for the spoilage of beer were investigated by Louis Pasteur during the 19th century. He was called upon to determine why French beer was inferior to German Beer.
• Brewing has a long history; the process has been know for long time, but the science of why came later.
![Page 3: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/3.jpg)
Brewing Process• Malting – Barley is adjusted and kilned• Milling – Exposes the starchy center• Mash – Conversion of starch to sugar by alpha-
amylase and beta-amylase• Rinse/Boil – Kills bacteria and hops add bitter
flavor• Cooling/Fermentation – Yeast addition,
conversion of fermentable sugars to carbon dioxide and alcohols.
![Page 4: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/4.jpg)
Flavor Aspects• Recipe• Water Chemistry (Brewery Specific)• Hops – strength and amount isomerized (a-acids)• Yeast – Strain and Strength
– Saccharomyces Ubarum – Saccharomyces Cerevisiae
• Fermentation: lag, log, rest, pH, dissolved oxygen, temperature, buffer capacity, carbon dioxide...
• Packaging – UV light, dissolved oxygen leads to bacterial spoilage (HACCP after fermentation)
• Flavor Agents: alcohols, sulfur compounds, esters, Di-acetyl and Pentane-2, 3-Dione, Polyphenols, Dimethylsulfide (DMS)
![Page 5: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/5.jpg)
Fault Examples
• Off flavors: fruity, harsh, sweet, or bitter
• Haze: level of particles in suspension
• Lack of body – level of non-fermentable sugars and polyphenols
• Poor head retention or formation
![Page 6: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/6.jpg)
Brewery Automation
• Complex chemical and biological process that needs to be controlled.
• Historically: Process controlled by manufacturing process (Brewery Specific)
• Today the manufacturing is driven by flexibility: The ability to produce a variety of beer using the same equipment.
![Page 7: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/7.jpg)
Automation PLC (Automationdirect)
Programmable Logic Controller
![Page 8: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/8.jpg)
Automation PLC (Automationdirect)
Relay Out
![Page 9: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/9.jpg)
Automation PLC (Automationdirect)Ladder
Programming View
![Page 10: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/10.jpg)
Automation PLC (Automationdirect)
Drum Programming
![Page 11: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/11.jpg)
Automation PLC (Automationdirect)
PID loops
![Page 12: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/12.jpg)
Brewery Sensors
![Page 13: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/13.jpg)
Dissolved Oxygen
• On Line
• Response time < 90 sec
• Interoperable: yes Immersion or Flow Through
• Performance: ± 1% of signal, max. ± 30 ppb• Location: Fermentation Tank, HACCP Point after Boiling
Stage
Mettler Toledo
![Page 14: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/14.jpg)
Carbon Dioxide• On Line
• Response time <60 seconds for 90% step change
• Interoperable: Yes – Alarm relay output
• Non-dispersive infrared (NDIR) repeatable to ± 20 ppm 0-2000 ppm range
• Location: Fermentation ducts or HVAC ducts
Veris Industries
![Page 15: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/15.jpg)
Dissolved Carbon Dioxide• At-Line
• Response time < 7 minutes
• Technology: fiber-optic, fluorescent dye
• Interoperable: Probable - 4-20 mA loop or 1-5 Vdc (analog output)
• Performance: ±5% of reading or 0.2% absolute• Location: Fermentation Tanks
YSI Life Science
![Page 16: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/16.jpg)
pH no-Glass
• On-line• Response time < 90 seconds• Interoperable: yes – standard VP connection• Performance: pH 0 ~14, 0 ~ 80°C• Gel electrolyte, Argenthal electrode, Temperature• Location: Mash tanks, Fermentation Tanks,
Maturation, Packaging
Mettler Toledo
![Page 17: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/17.jpg)
Glucose/Alcohol Electrode
• On-Line
• Response time < 2 Minutes
• Interoperable: yes small voltage, BNC connector
• Reproducibility ~ 3%
• Location: Mash, Fermentation, Packaging
Universal Sensors Inc.
![Page 18: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/18.jpg)
Yeast Monitor• At-Line
• Response time: Real-time
• Technology: Electrode, temperature, capacitance
• Interoperable: yes – RS232 port, alarm outputs
• 10 Cell size/strain positions
• Location: Fermentation, Maturation, Yeast Storage
Aber Instruments
![Page 19: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/19.jpg)
Yeast Monitor• On-Line
• Response time: Real-time
• Technology: Radio frequency dielectrics and software
– Measures Capacitance in living yeast cells (Plasma Membranes)
• Interoperable: yes – RS232 port and Ethernet, alarm outputs
• Location: Fermentation, Maturation, Yeast Storage
Aber Instruments
![Page 20: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/20.jpg)
Protein and Polyphenol Detection via Surface Plasma Resonance
• Off-line
• Response time: Rapid Confirmation
• Interoperable: No, standalone system
• Flexibility to determine multiple compounds with multiple sensor chip configurations
• Location: Brewing Lab (determine flavor constituents)
Biacore
![Page 21: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/21.jpg)
Gram Negative/ Gram Positive Bacteria Contamination
• Gram Negative– Acetic Acid Bacteria
– Pectinatus cervisiiphilus
– Enterobacteriaceae
– Zymomonas
– Pectinatus frisingensis
– Selenomonas Lacticifex
– Zymophilus raffinosivorans
– Zymophilus paucivorans
– Megaspaera
• Gram Positive – Lactobacillus
– Lactic Acid bacteria
– Pediococcus
– Leuconostoc
– Homofermentative cocci
– Kocuria, Micrococcus and Staphylococcus
– Endospore-forming bacteria
![Page 22: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/22.jpg)
Biolog’s G+/G- Yeast detection
• Off-Line – Rapid detection
• Standalone System (the rest)
• MicroPlate ~ 96 different Chemical Substrates
• G+ >310; G- >500; Yeast >265
• < 5 min Hand prep
• Photo-Optical (density)
• Automated database
• Location: Through-out
![Page 23: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/23.jpg)
Biotrace’s ATP Bioluminescence • All in one Test Kit: swabbing• Off Line: Cleanliness Check• ATP enzyme-driven light emissions • Response time < 30 secs• Measures light output (luminometer) or living
cells• Location: Throughout • Specs:<150 RLU (pass)• >300 RLU (Fail)• Tanks, Valves, Doors…
![Page 24: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/24.jpg)
Chemunex Chemscan RDI• Off-line: Rapid Identification
• Technology: Combination of 1)Laser Scanning 2)cell labeling and 3)automated/database
• Fully Automated: 20 hr Presence; 1 hour direct Count
• High throughput ~ 60 samples per hour
• Drawback: lack of specific recognition of Brewery beer-spoilage bacteria.
• Subspecies of: – Pediococcus
– Lactobacillus
![Page 25: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/25.jpg)
Qualicon/DuPont’s RiboPrinting• Off-Line: Rapid thorough detection ~8 hrs
• Technology: Random Amplified Polymorphic DNA PCR.
• Extracts: DNA; rRNA; compares gene sequence
• DNA extracted mixed with chemiluminescent; captured on digital image; Fingerprint is compared with database “RiboPrint”
• Powerful tool for identifying subspecies of beer-spoiling bacteria during the middle to late fermentation stages.
![Page 26: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/26.jpg)
Conclusions
• Biosensor use is dependant upon many factors– Brewery size: Throughput, variety of brands, total
energy used.– Cost: Potential Savings, Ability to integrate in to
architecture, Installation cost, man power…– Potential Market: Better, Cheaper, Faster
• Anheuser-Busch: 47% of American Market, produced 127.9 Million barrels (101.8 M domestically), Gross sales of $15.686 billion dollars, and over 30 different brands.
– Distributed Generation: The business of business is business. Distributed Manufacturing.
![Page 27: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/27.jpg)
Conclusions
• Sensing and conditioning a signal is only half of the process.– Act and React: Interoperable with existing
systems• Overarching Control Scheme
• Manufacturing Procedures
![Page 28: Biological and Chemical Detection in the Brewing Industry Submitted by: David Jones.](https://reader035.fdocuments.net/reader035/viewer/2022062516/56649d405503460f94a1a2b1/html5/thumbnails/28.jpg)
Any Questions?