Bio-MicroelectromechanicalSystems (Bio-MEMS)
GROUP 6
廖宇鴻陳奕達陳奐晴
![Page 2: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/2.jpg)
OUTLINE - 1
• Introduction to Bio-MEMS• Traditional MEMS & Fabrication• Bio-MEMS feature• Materials• Manipulation
• Bio-MEMS in Biosensor and Diagnostics
• Bio-MEMS in Tissue Engineering and Medical implants
![Page 3: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/3.jpg)
What is a MEMS?
• Micro-• Components 1~100 mm
• Electro-
• Mechanical• Sensor, Actuator (transducers)
• System• integrated different elements
Source: http://smartphoneworld.me/mobile-commerce-2-0-where-payments-location-and-advertising-converge/
![Page 4: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/4.jpg)
Ex: MEMS Accelerometer
• Medical applications:• CPR compressions depth
• Step counter
• Physical training
• Wide Commercial Applications• Wii, Car, Smart Phone
• Inertial Measurement Unit• Integrated with Gyroscope, Magnetometers
3-Axis Integrated AccelerometerSource: http://www.mems.ece.ufl.edu/bml/BML_Accelerometerproject.htm
![Page 5: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/5.jpg)
MEMS Process• Modified IC Fabrication Technology
• Deposition (CVD, PVD…)
• Patterning (Photolithography, e-Beam lithography …)
• Etching (Wet Etching, Dry Etching…)
• Bulk/Surface Micromachining
Source: CMOS-based chemical microsensors, Andreas Hierlemann and Henry Baltes
![Page 6: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/6.jpg)
Bio-MEMS
• Advantages:• Sensitivity, Portability, Clinical Convenience
• Diagnostics & Drug delivery • Direct interaction with a biological environment
• Usually Disposable, Large size
• Conventional Silicon & Glass?• Bad Biocompatibility
• Too expensive
Source: Wikipedia
![Page 7: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/7.jpg)
Bio-MEMS Materials
• Polymers – Biocompatible, Cheaper, Stable• PDMS (elastomeric: can use soft lithography)
• SU-8 (photoresist, high aspect ratio)
• PMMA
PDMS fabrication processSource: McDonald, J., & Whitesides, G. (2002).
SU-8 Photolithography ProcessSource: Updates in Advanced Lithography ch5By Athanasios Milionis, et. al
![Page 8: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/8.jpg)
Substance (Cell, Protein, etc.) Manipulation• Electrokinetics
• Electrophoresis
• Isoelectric focusing (IEF)
• Dielectrophoresis (DEP) • no need to be charged, can work in DC or AC
• Microfluidics
Source: MICROFLUIDIC CELL SEPARATION AND SORTING: A SHORT REVIEW, Walter Minnella
Source: https://pratted.wordpress.com/tag/dielectrophoresis/
![Page 9: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/9.jpg)
OUTLINE - 2
• Introduction to Bio-MEMS
•Bio-MEMS in Biosensor and Diagnostics• Bio-MEMS as Miniaturized Biosensors• Glucose biosensor• Bio-MEMS for diagnostics• PCR Chip
• Bio-MEMS in Tissue Engineering and Medical implants
![Page 10: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/10.jpg)
Bio-mems History
• In 1967, S. B. Carter reported the use of shadow-evaporated palladium islands for cell attachment.
• In 1985, Unipath Inc. commercialized ClearBlue, a pregnancy test still used today that can be considered the first microfluidic device containing paper and the first microfluidic product to market.
• In 1990, Andreas Manz and H. Michael Widmer from Ciba-Geigy , Switzerland first coined the term micro total analysis system (μTAS) in their seminal paper proposing the use of miniaturized total chemical analysis systems for chemical sensing.
• In 1991, the first oligonucleotide chip was developed
• In 1993, George M. Whitesides introduced inexpensive PDMS-based microfabrication and this revolutionized the bio-MEMS field.
• In 1998, the first solid microneedles were developed for drug delivery.
• In 1998, the first continuous-flow polymerase chain reaction chip was developed
• In 1999, the first demonstration of heterogeneous laminar flows for selective treatment of cells in microchannels
![Page 11: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/11.jpg)
Bio-MEMS as Miniaturized Biosensors
• Biosensors consist of:• Bioreceptor
• antibody–antigen interactions
• nucleic acid interactions
• enzymatic interactions
• cellular interactions
• interactions using biomimetic materials
• Transducer• mechanical detection
• electrical detection
• optical detection.
![Page 12: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/12.jpg)
Kinds of Biosensors
• Micromechanical sensors
• Electrical and electrochemical sensors
• Optical sensors
![Page 13: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/13.jpg)
Physical phenomenom
detector
Detect physical change
ConverterChemical
phenomenomdetector
molecular recognitioncomponent
Detect chemical change
TransferCircuit
Amplifier
VoltageOutput
Data saverAndControlInterface
![Page 14: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/14.jpg)
![Page 15: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/15.jpg)
Glucose biosensor• Made only of paper and a water-repellant polymer.
• Detect the levels of two key liver enzymes, AST (aspartate transaminase) and ALT (alanine transaminase).
http://singularityhub.com/2010/06/28/3-ground-breaking-miniature-biosensors-that-could-change-world-medicine
![Page 16: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/16.jpg)
Bio-MEMS for diagnostics
• Goals:• Make high-throughput genome analysis faster and cheaper.
• Identify activated genes and their sequences.
• Methods:• genomic and proteomic microarray
• Application:• neonatal screening
• identifying disease risk
• predicting therapy efficacy
![Page 17: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/17.jpg)
PCR(polymerase chain reaction) chips
• Amplification of DNA sequences
• Drawback:• Take hours to complete
• Expensive reagent
• Rapid heat transfer and fast mixing• Larger surface-to-volume ratio
• Short diffusion distances
• portability for point-of-care application
![Page 18: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/18.jpg)
![Page 19: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/19.jpg)
OUTLINE - 3
• Introduction to Bio-MEMS
• Bio-MEMS in Biosensor and Diagnostics
•Bio-MEMS in Tissue Engineering and Medical implants• Bio-MEMS in Tissue Engineering• Lung-on-a-Chip Device• Bio-MEMS in Medical Implants and Surgery
![Page 20: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/20.jpg)
Bio-MEMS in tissue engineering
• Conventional cell culture technology
• unable to efficiently allow combinatorial testing of drug candidates, growth factors, neuropeptides, genes, and retroviruses in cell culture medium
• large number of cells and supplies
• bulky incubators
• human labour
• Microfluidic cell cultures
• Automated
• lower overall cost
• higher throughput
• More quantitative descriptions of
single-cell behaviour variability
![Page 21: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/21.jpg)
Lung-on-a-Chip Device
• Simulates the contraction of the diaphragm, which triggers the intrapleural pressure to decrease, leading to an expansion of alveoli.
![Page 22: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/22.jpg)
Bio-MEMS in Medical Implants and Surgery
• Conventional Transdermal Delivery
• limited by the barrier properties of the outermost skin layer, the stratum corneum .
• Microneedles
• deliver a broad range of different low molecular weight drugs, biotherapeutics and vaccines
• In addition to applications in the skin, microneedles have also been adapted for delivery of bioactives into the eye and into cells.
![Page 23: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/23.jpg)
Bio-MEMS in medical implants and surgery• As a micron-scale device, a
microneedle should be large enough to deliver almost any drug or small particulate formulation, but still be small enough to avoid pain, fear and the need for expert training to administer.
• A microneedle allows precise tissue localization of delivery, such as within the skin, the suprachoroidal space of the eye, and the cell nucleus.
![Page 24: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/24.jpg)
Bio-MEMS in Medical Implants and Surgery
• force sensor array with several sensing points
• Each point (transducer) of the sensor array detects the force applied to the patient's tissue by the grasper.
• This force is translated to proportional pressures that are sent to a joystick in the surgeon’s hand. The surgeon "feels" the change in pressure and adjusts as needed.
![Page 25: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/25.jpg)
Development of Bio-mems• Precision, Accuracy
• Information digitalize
• Integration
• Efficiency
• Distance Monitor
• Reduce the Power Cost
![Page 26: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/26.jpg)
Reference-1
• Wikipedia: Microelectromechanical systems (https://en.wikipedia.org/wiki/Microelectromechanical_systems)
• A high sensitivity z-axis torsional silicon accelerometer, Selvakumar, A. ; Ayazi, F. ; Najafi, K. Electron Devices Meeting, 1996. IEDM '96., International
• CMOS-based chemical microsensors, Andreas Hierlemann and Henry Baltes
• Wikipedia: Bio-MEMS (https://en.wikipedia.org/wiki/Bio-MEMS)
• BioMEMS and Biomedical Nanotechnology Volume IV Biomolecular Sensing, Processing and Analysis, Edited by Rashid Bashir and Steve Wereley, Purdue University, West Lafayette, IN ---- CH4, 5, 13
• How to Sort Circulating Tumor Cells Part IV: Electrokinetic Separation https://pratted.wordpress.com/2012/11/26/how-to-sort-circulating-tumor-cells-part-iv-electrokinetic-separation/
![Page 27: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/27.jpg)
Reference-2
• How to Sort Circulating Tumor Cells Part IV: Electrokinetic Separation https://pratted.wordpress.com/2012/11/26/how-to-sort-circulating-tumor-cells-part-iv-electrokinetic-separation/
• http://singularityhub.com/2010/06/28/3-ground-breaking-miniature-biosensors-that-could-change-world-medicine/
• https://en.wikipedia.org/wiki/Biosensor
• https://www.youtube.com/watch?v=-ew0bn8mGAA
![Page 28: Bio-MicroElectroMechanical Systems (Bio-MEMS)cc.ee.ntu.edu.tw/~ultrasound/belab/midterm_oral_files/2015_104_1/1… · technology •unable to efficiently allow combinatorial testing](https://reader034.fdocuments.net/reader034/viewer/2022042402/5f12333b3f79c66601173d01/html5/thumbnails/28.jpg)
Reference-3
• https://en.m.wikipedia.org/wiki/Lung_on_a_chip
• https://en.m.wikipedia.org/wiki/Bio-MEMS
• https://www.materialsnet.com.tw/DocPrint.aspx?id=10917
• http://newsletter.sinica.edu.tw/file/file/77/7745.pdf