![Page 1: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/1.jpg)
Binks Smart Pump
![Page 2: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/2.jpg)
Smart Pump Product Line
Electric Smart Pump
• E2-20: 5 GPM (260 PSI)
• E2-30: 8 GPM (260 PSI)
• E4-60: 16 GPM (260 PSI)
• E4-90: 24 GPM (203 PSI)
![Page 3: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/3.jpg)
Accessories:• Low Shear Smart BPR
¾” to 2” Connections
• Smart Card: Automatic controls for
“Smart Circ” operation
Smart Pump Product Line
![Page 4: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/4.jpg)
• Fluid Sections
• CV Drive Section
• 40:1 Gearbox
• 1.5 HP AC Motor
Description E2-20: 5 GPMDescription E2-20: 5 GPM
![Page 5: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/5.jpg)
CV Cam
Cam Follower
Swivel Joint Tension Springs
Slide Rails
Description E2-20: 5 GPMDescription E2-20: 5 GPM
![Page 6: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/6.jpg)
• AC Motor drives gear box and CV Cam.• Motor is controlled by inverter with either manual or PLC instruction.
• The motor frequency is directly proportional to the Fluid Output!
Motor Speed (HZ)
Pump CPMFluid Flow
(GPM)
20 9.8 1.23
25 12.25 1.53
30 14.7 1.84
35 17.25 2.16
40 19.8 2.48
45 22.25 2.79
50 24.7 3.09
55 27.1 3.39
60 29.5 3.69
65 31.85 3.99
70 34.2 4.28
75 36.6 4.58
80 39 4.88
Description E2-20: 5 GPMDescription E2-20: 5 GPM
![Page 7: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/7.jpg)
Main Pump Assembly
Description E2-30: 8 GPM
Main Components
• 2 HP Motor & Gearbox
• Main Cam Shaft and Bearings
• 2 Cylinders 4 Ball Check
• Carriage and Cam Follower
• Carriage Support Shaft and Linear Ball Bearing Bushes
![Page 8: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/8.jpg)
Description E2-30: 8 GPM
• 2 HP motor reduced through 56:1 gearbox.
• Single “constant velocity” cam & carriage assembly ensures no “hard” connections.
• (2) horizontally opposed fluid sections provide 8 GPM fluid output.
![Page 9: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/9.jpg)
E2-30 Fluid Section
• Quick disconnect fluid section.
• Internal piston/fluid seal.
• Low pressure bellows seal.
• “Run to Failure” back up seal.
![Page 10: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/10.jpg)
Main Components
• 5 HP Motor & Gearbox
• Main Cam Shaft and Bearings
• 4 Cylinders 8 Ball Check
• Carriage and Cam Follower
• Carriage Support Shaft and Linear Ball Bearing Bushes
Main Pump Assembly
Description E4-60 & E4-9016 & 24 GPM
Description E4-60 & E4-9016 & 24 GPM
![Page 11: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/11.jpg)
Cam area drives (4) horizontal fluid pistons therefore providing a (4) cylinder true positive displacement operating pump.
Description E4-60: 15 GPMDescription E4-60: 15 GPM
View showing Min Max Cylinder position
![Page 12: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/12.jpg)
Quick Disconnect Fluid Section
QD Sanitary Clamp piston
shaft connection
“Module” Designed Fluid Section
Complete fluid section can be removed by disconnecting (4) sanitary clamps and removal of (8) bolts!
Bolted connections
![Page 13: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/13.jpg)
Bellows: “Run to Failure”
Use of secondary chevron style seal behind bellows provides a back up seal and allows for visual indication of bellows failure.
• Material flow path
• Secondary Seal (vertical piston pump style seal)
• Bellows location
Provides visual indication of bellows failure and allows operator time to repair before affecting production.
![Page 14: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/14.jpg)
E4-60 Energy Consumption
![Page 15: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/15.jpg)
E2-30 Energy Consumption
![Page 16: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203.](https://reader038.fdocuments.net/reader038/viewer/2022102523/551694aa550346a25b8b5058/html5/thumbnails/16.jpg)
Binks Smart Pumps
ITW Ransburg – BinksITW Group – Finishing Division
320 Phillips Ave