BERS Program Administration
description
Transcript of BERS Program Administration
FLORIDA SOLAR ENERGY
CENTERCreating Energy Independence Since 1975
P. Fairey
BERS Program Administration
BERS Program Administration
Training Compliance Rating Software Rating Registry Changing Federal Programs
Training
Residential Rater training At least 4 per year, more if demand requires Administer Florida & RESNET core test
Software training – at least 4 per year Commercial Rater training
At least 2 per year, more if demand requires Administer Florida tests
Recertification – at least 1 class per month for 12 months around code change
FSEC Training Center
Training & Exam Modules
18 instruction modules Serve up to 36
students/class Envelope leakage
using blower doors Air distribution system
leakage using duct tester
Combustion Appliance Zone (CAZ) training
Individual practicum exams
CAZ Training
CAZ pressure mapping
Hot water heater flue draft testing
Flame roll-out Furnace inspection
procedures Furnace flue draft
testing Upcoming RESNET
requirements
DCA Administration
Document and report test scores to DCA Assign unique Rater certification numbers Print and distribute DCA Rater certifications Report test scores to students Maintain database of certified raters (daily
updates) Maintain database of registered Ratings
(continuous) Print and mail BERS brochure (continuous) Provide Rater technical support (daily) Provide Code technical support (daily) Respond to e-mail and phone queries (daily) Participate in national conferences
RESNET Requirements
Maintain RESNET Accreditations Rating Provider Training Provider Software Provider
Create & provide RESNET-approved Professional Development courses (new requirement)
Maintain RESNET Trainer certifications Maintain RESNET QA Designee certifications Perform RESNET QA activities
Review of 100% of building files for each Rater Field review of 1% of Rated homes for each
Rater
Other RESNET Activities
Participate in RESNET Conferences Serve on RESNET Committees
Standing Standards Committee (Chair) Standing Technical Committee Standing Training & Education Committee Standing COMNET Committee
Serve on RESNET Board of Directors President of Board (P. Fairey) – two terms
2004-2006 2008-2010
Software Accreditations
Residential Software Florida Energy Code IRS New Home Tax Credit RESNET HERS Ratings IECC 2006
Commercial Software Florida Energy Code IRS Tax Deduction accredited ASHRAE Standard 140 compliant USGBC – LEED NC 2009 compliant ASHRAE 90.1 Appendix G compliant
Software Validation
Residential Verification Requirements HERS BESTEST Loads suite Reference Home auto-generation test RESNET HVAC test suite RESNET DSE test suite RESNET Hot Water test suite
Commercial Verification Requirements ASHRAE Standard 140 (Section 5) test
suite
Building Load Tests
Load Difference Tests
DSE Tests
Hot Water Tests
Software Upgrades
EnergyGauge Summit: Enthalpy Recovery Ventilation Systems in
testing Frequently requested feature Will be in 2010 Code if allowed by Building
Commission
Software Upgrades
Next Generation Software (2013 Code and Beyond) Work from anywhere: over the internet or
on local machine Easier file transfer: import and export
GBXML format for interoperability with other software
Model more choices: simulate using DOE2 or EnergyPlus
Learn once: same platform for residential and commercial
Software Upgrades
2010 Code multi-zone, multi-fuel residential model Coding largely complete Undergoing in-house alpha testing
Energy Star 2011 v.3 module Added Reference Home and many new
reports Software coding in progress
Software Upgrade
Cost Optimization module Working internal version Ranking of Energy Conservation
Measures (ECMs) Incremental cost optimization Excellent for existing home retrofit apps User interface still to be developed
Analysis Methods
EnergyGauge simulations used to project energy use and costs (based on utility inputs)
EnergyGauge results used to calculate 30-year energy cost savings cash flow stream (benefits)
Individual Energy Conservation Measure (ECM) costs used to calculate 30-year investment cost cash flow stream (mortgage costs)
PVBC from above calculation used to rank order ECMs from largest to smallest
The Analysis Process
All defined ECMs rank ordered by PVBC ratio through one-by-one incorporation into the original home (the baseline)
Single ECM with largest PVBC incorporated into the original home, creating a revised baseline.
Revised baseline used as basis for individual ECM ranking using remaining ECMs
Next remaining ECM with largest PVBC incorporated into revised baseline
Ad infinitum until ECM list exhausted or analysis limits reached.
Annual Total (Full Cost)
1st Year (Full Cost)
Rating Registration Update
Improvements in Process for Registration End Goal –faster processing of ratings
while maintaining quality control Better flagging of issues of incoming files Full pdf reports stored in registry for
archive retrieval by rater Automatic monthly billing, on-line
payment and account viewing for rater
Expenditures & Revenues
July 1, 2009 - June 30, 2010
Cost Center Expenditures Revenues Net
Rater Training $271,289 $230,075 ($41,214)
Software $365,160 $404,746 $39,586
Registry $65,834 $42,108 ($23,726)
Totals $702,283 $676,928 ($25,354)
FLORIDA SOLAR ENERGY
CENTERCreating Energy Independence Since 1975
P. Fairey
Federal and Other Programs
EPA Energy Star Program
Requires HERS ratings Current program (version 2) :
HERS Index of 77 or lower Thermal bypass checklist (by Rater)
2011 program (version 3): New e-Star Reference Home standard Target HERS Index computed based on home
size HERS Index of 65-72 (or less) will be required Requires 3 new checklists
HVAC System Quality Installation Contractor list
HVAC System Quality Installation Rater list Water Management System Builder list
DOE Builders Challenge
Requires HERS Ratings Requires HERS Index of 70 or less Requires that specific quality measures
be considered and verified by Rater Program requirements may be tightened
in the future Lower qualifying HERS Index Closer alignment with EPA Energy Star
program (version 4 ~2014).
Federal Tax Incentives
Residential New Home Tax Credit Requires 50% savings on heating and cooling Expired but likely to return (has strong
bipartisan support) Requires accredited software (EnergyGauge
is accredited) Requires verification by Rater or equivalent
(there is currently no equivalent) Commercial New Building Tax Deduction
Requires 50% savings on heating, cooling, ventilation, hot water and interior lighting
Requires software accreditation by IRS (EnergyGauge is accredited)
Federal Energy Labeling
U.S. DOE considering national home energy labeling program
Exact nature and details still unknown Leaning toward absolute energy label
(source energy MBtu) Partitioned onto a 10 point scale based on
climate and RECS data Likely generated by Federal Home Energy
Survey (HES) software (LBNL) Possible replacement for current
weatherization audit software (NEAT) May pertain only to existing homes Unlikely to replace HERS Index
ASHRAE
Building Energy Modeling Professional (BEMP) Certification for commercial building
modelers Likely to be adopted as basic requirement
for certification by others (e.g. COMNET) Building Energy Quotient
Program (EQ) Metric for as designed energy
use Metric for actual energy use Pilot stage only
USGBC LEED Programs
LEED- H program (new homes) Uses HERS rating systems (EnergyGauge
USA) to determine energy efficiency points LEED – NC program (new commercial bldg)
May use EnergyGauge Summit Premier to determine energy efficiency points, automatically generate reference design and generate data for required LEED reports
COMNET
New commercial building initiative of RESNET
Manual on Commercial Building Energy Modeling Guidelines and Procedures completed http://www.comnet.org/
Embarking on standards development Software verification and accreditation Modeler, rater/verifier certification
BERS Program Administration
Training Compliance Rating Software Rating Registry Changing Federal Programs
Thank you.