Benzene Fenceline Monitoring; - Conference Information...Benzene Fenceline Monitoring; Lessons...
Transcript of Benzene Fenceline Monitoring; - Conference Information...Benzene Fenceline Monitoring; Lessons...
-
Benzene Fenceline Monitoring;Lessons Learned for Ongoing Compliance
August 8, 2018
Jason Robles, President
-
Presentation Topics• EPA Alternative Test Method ALT-122• Refinery Sector Proposed Amendments
March 2018• Refinery “X” Pilot Study Results
- Laboratory Comparison- Data Trends- Obstacles & Solutions
-
• Benzene Method Calculation• Field Duplicates and Field Blanks Required
- Original: 2 Field Blanks plus 1 Field Duplicate for every 10 Field Samples
- Updated: 1 Field Blank and 1 Field Duplicate for
-
Signed by EPA March 19, 2018• As a result of 3 separate petitions filed by AFPM/API (2)
& Earthjustice (1)• Addresses several sections of the RSR – Fenceline
Monitoring Specific:- ‘Known VOC’ defined in relation to additional monitors at
50m- Corrective Action clarification- Reporting Timing Requirements- Laboratory calculation/reporting of duplicates
RSR Proposed Amendments
-
Pilot Sampling Period: 09/19/17 - 12/26/177 Sampling Periods
Located in Northeast United States3 different laboratories for data comparison• Lab A: 14 Field Samples, 2 Field Blanks & 2 Duplicates• Lab B: 4 Field Samples• Lab C: 4 Field SamplesSame sampling media for each laboratory
Refinery “X” Pilot Study
-
Pilot Study: Refinery “X”
-
• Lab A: 126 Samples
• Lab B: 28 Samples
• Lab C: 16 Samples
170 Total Samples
Pilot Study: Lab Data
-
• Refiner analyzed results using Tukey-Kramer Method- All labs performed within acceptable level of one
another- Lab A statistically most accurate
• Average report TAT varied
Pilot Study: Lab Comparison
• Lab C closed after 4 sample periods
-
0.73 0.86
1.20
3.80
2.40
0.88
1.20 1.40
2.80
0.80
1.40
1.20
3.40
0.84
1.50
1.90
1.50
1.40
2.00
1.70
5.10
0.19
2.00 2.10
6.00
1.80
1.10
1.00
0.78 0.90
1.32
3.86
2.04
0.78
1.82
1.32
2.00
0.73
1.45
1.01
3.44
0.86
1.44
1.79
1.61 1.64
2.33
1.81
4.28
1.38 1.47
1.87
4.87
1.61
1.33
0.92
0.90 1.06
1.68
4.84
2.82
0.88
1.34
1.60
2.70
0.96
1.78
1.30
3.37
0.82
1.44
1.85
0.0
1.0
2.0
3.0
4.0
5.0
6.0
Benzen
e ug
/m3
Shelters
Side by Side Laboratory Results 09/19/17‐12/26/17
Lab ALab BLab C
Round 1 Round 2 Round 3 Round 4 Round 5 Round 6 Round 7
Pilot Study: Lab Comparison
-
Lab A: 18 Samples per roundLab B: 4 Samples per roundLab C: 4 Samples round
Pilot Study: Lab Comparison
-
Pilot Study: Data Trends
-
Possible cause of Shelter 01
Benzene Level Increase?
Directional VOC Accumulation Cycle 7
Shelter 01 Data:Round 5: 1.50 ug/m3Round 6: 5.10 ug/m3Round 7: 6.00 ug/m3
Pilot Study: Data Trends
-
0102
13 0314
Pilot Study: Data Trends
-
Obstacle: Staying organized while using 3 labsSolution: Color coding
Pilot Study: Obstacles & Solutions
-
Obstacle: Error-free Field Test Data Sheet
Pilot Study: Obstacles & Solutions
-
Solution: Mobile Field Deployment & Collection
• Met Data, Time & Date Stamp collected automatically
• Information transmitted to Laboratory via ‘the cloud’
• Laboratory downloads all Field Test Data Sheet information
Limited handwriting and data entry greatly reduces time spent
and errors
Pilot Study: Obstacles & Solutions
-
6732 Mayard RoadHouston, Texas 77041
Phone +1 (713) 983-0800Fax +1 (713) [email protected]
www.325Monitoring.com
Questions?