Benzene Fenceline Monitoring; Lessons Learned for Ongoing Compliance August 8, 2018 Jason Robles, President

Transcript of Benzene Fenceline Monitoring; - Conference Information...Benzene Fenceline Monitoring; Lessons...

  • Benzene Fenceline Monitoring;Lessons Learned for Ongoing Compliance

    August 8, 2018

    Jason Robles, President

  • Presentation Topics• EPA Alternative Test Method ALT-122• Refinery Sector Proposed Amendments

    March 2018• Refinery “X” Pilot Study Results

    - Laboratory Comparison- Data Trends- Obstacles & Solutions

  • • Benzene Method Calculation• Field Duplicates and Field Blanks Required

    - Original: 2 Field Blanks plus 1 Field Duplicate for every 10 Field Samples

    - Updated: 1 Field Blank and 1 Field Duplicate for

  • Signed by EPA March 19, 2018• As a result of 3 separate petitions filed by AFPM/API (2)

    & Earthjustice (1)• Addresses several sections of the RSR – Fenceline

    Monitoring Specific:- ‘Known VOC’ defined in relation to additional monitors at

    50m- Corrective Action clarification- Reporting Timing Requirements- Laboratory calculation/reporting of duplicates

    RSR Proposed Amendments

  • Pilot Sampling Period: 09/19/17 - 12/26/177 Sampling Periods

    Located in Northeast United States3 different laboratories for data comparison• Lab A: 14 Field Samples, 2 Field Blanks & 2 Duplicates• Lab B: 4 Field Samples• Lab C: 4 Field SamplesSame sampling media for each laboratory

    Refinery “X” Pilot Study

  • Pilot Study: Refinery “X”

  • • Lab A: 126 Samples

    • Lab B: 28 Samples

    • Lab C: 16 Samples

    170 Total Samples

    Pilot Study: Lab Data

  • • Refiner analyzed results using Tukey-Kramer Method- All labs performed within acceptable level of one

    another- Lab A statistically most accurate

    • Average report TAT varied

    Pilot Study: Lab Comparison

    • Lab C closed after 4 sample periods

  • 0.73 0.86

    1.20

    3.80

    2.40

    0.88

    1.20 1.40

    2.80

    0.80

    1.40

    1.20

    3.40

    0.84

    1.50

    1.90

    1.50

    1.40

    2.00

    1.70

    5.10

    0.19

    2.00 2.10

    6.00

    1.80

    1.10

    1.00

    0.78 0.90

    1.32

    3.86

    2.04

    0.78

    1.82

    1.32

    2.00

    0.73

    1.45

    1.01

    3.44

    0.86

    1.44

    1.79

    1.61 1.64

    2.33

    1.81

    4.28

    1.38 1.47

    1.87

    4.87

    1.61

    1.33

    0.92

    0.90 1.06

    1.68

    4.84

    2.82

    0.88

    1.34

    1.60

    2.70

    0.96

    1.78

    1.30

    3.37

    0.82

    1.44

    1.85

    0.0

    1.0

    2.0

    3.0

    4.0

    5.0

    6.0

    Benzen

    e ug

    /m3

    Shelters

    Side by Side Laboratory Results 09/19/17‐12/26/17

    Lab ALab BLab C

    Round 1 Round 2 Round 3 Round 4 Round 5 Round 6 Round 7

    Pilot Study: Lab Comparison

  • Lab A: 18 Samples per roundLab B: 4 Samples per roundLab C: 4 Samples round

    Pilot Study: Lab Comparison

  • Pilot Study: Data Trends

  • Possible cause of Shelter 01

    Benzene Level Increase?

    Directional VOC Accumulation Cycle 7

    Shelter 01 Data:Round 5: 1.50 ug/m3Round 6: 5.10 ug/m3Round 7: 6.00 ug/m3

    Pilot Study: Data Trends

  • 0102

    13 0314

    Pilot Study: Data Trends

  • Obstacle: Staying organized while using 3 labsSolution: Color coding

    Pilot Study: Obstacles & Solutions

  • Obstacle: Error-free Field Test Data Sheet

    Pilot Study: Obstacles & Solutions

  • Solution: Mobile Field Deployment & Collection

    • Met Data, Time & Date Stamp collected automatically

    • Information transmitted to Laboratory via ‘the cloud’

    • Laboratory downloads all Field Test Data Sheet information

    Limited handwriting and data entry greatly reduces time spent

    and errors

    Pilot Study: Obstacles & Solutions

  • 6732 Mayard RoadHouston, Texas 77041

    Phone +1 (713) 983-0800Fax +1 (713) [email protected]