BelWü 2016+ - TERENA...~200 backbone router 40 * ASR 9000 (9006, 9010) 23 * ASR 1000 Cat 6509,...
Transcript of BelWü 2016+ - TERENA...~200 backbone router 40 * ASR 9000 (9006, 9010) 23 * ASR 1000 Cat 6509,...
Baden-Württemberg Extended LAN
Academic Network of the Federal State of Baden-Württemberg, Germany
We are connecting:
9 Universities
47 Universities for applied sciences, etc.
Numerous schools, libraries, student dormitories and other institutes
And offering services (mostly for Schools):
Webhosting (e.g. Moodle e-learning) and youth protection HTTP proxy
E-Mail, SPAM detection
Network services (DNS, NTP, ...)
2
2
A short history1987 BelWü was founded
First bridged network, later routed, partially IP over X.25
1989 All (BaWü) Universities are connected to BelWü
1994 Full mesh of all Universities with 2-34 Mbit/s
1998 Upgrade to Cisco 7500 and 155 Mbit/s ATM links
2001 Upgrade to Gbit/s-Network with Cisco 12410/GSR
SRP/DPT rings with 2.4 Gbit/s and 622 Mbit/s
2006 First 10Gbit/s link
2010 Upgrade to 100Gbit/s-ready-Network with Cisco ASR 9000,
own (passive) DWDM and (multiple) 10Gbit/s Ethernet links
2013 June: First 100Gbit/s link
2014 100Gbit/s at each University PoPs3
3
Current BelWü Network
4
BelWü (Fiber) Footprint
5
Backbone through Baden-Württemberg
> 3.000 km fiber & 10GigE bandwidth
50 POPs, 50 optical amplifiers(spans shorter than 100/120km)
p2p lambdas: >80 * 10G & 10 * 100G(lambdas hop-to-hop only)
60/170 * 10GE260/650 * GE140 * FE - customer/all IP ports
2 * 100GE - Layer 2
~200 backbone router
40 * ASR 9000 (9006, 9010)
23 * ASR 1000
Cat 6509, Cisco 2821, 2921, 3925
~2.500 others like Cisco 8xx DSL/
(C) BelWü-Koordination (Universität Stuttgart), www.belwue.de
(Dieses Bild basiert auf dem Bild "Baden-Wuerttemberg location map.svg" aus http://commons.wikimedia.org
und steht unter der GNU-Lizenz für freie Dokumentation. Die Urheber sind Ssch, kjunix.)
Leitungen
10GE Bandbreite optisches Fenster existierende DF Bandbreite
BelWü-KoordinationUniversität Stuttgart
http://www.belwue.deTue Apr 15 2014
Stand 12/2012
Standorte mit Universität Hochschule Anderer
25
96
42
26
58
5134
40
70
94
51
33
112
25
5015
45
3565
49
68
50
60
2040
23
76
(~250?)
30
42 Leitungslänge in km (ca.)
(~280?) 60
100
33
90
10028
60
50
110?
Böblingen
Freudenstadt
Rastatt
Baden-Baden
Rotten-burg
Biberach
Weingarten
Ravensburg
Friedrichshafen
Sigmaringen
Albstadt
Reutlingen
Nürtingen
Esslingen
GöppingenGeislingen
Heidenheim
AalenSchw. Gmünd
Künzelsau
Schw. HallHeilbronn
Mosbach
Ludwigsburg
Pforzheim
Kehl
Lörrach
Tuttlingen
Trossingen
V-SFurtwangen
HorbOffenburg
Gengenbach
PH FA
Frankfurt
Tübingen
Ulm
Konstanz
Freiburg
Karlsruhe
HohenheimStuttgart
Heidelberg
Mannheim
5
BelWü optical and IP Network 2014
On fibers:
Static DWDM filter w/ 4-8 Channels and EDFA
Colored 10GigE DWDM transceiver
(Menara w/ FEC) in IP Router (ASR 9000)
Parallel: Ekinops/Opelian 10x10G to 100G Mux
Hop-to-hop, no long-run wavelengths
Today:
Fiber on main paths
Redundancy via rented 10GigE bandwidths
Target Q2/2016:
Continous & redundant fiber-only network
6
(Big) Campus - today
Nicht eingezeichnet:Dispersionskompensation
7
BelWü-NeIF10G bandwidths
Paralell to IP Network
10G bandwidths with 10x10G to 100G Mux & 10G matrix
Not redundant
Backbone capacity
Projects
Campus-Campus Links
(Possible 100G backbone links for IP Routers)
“Test” for bandwidths demand ?8
Netztopologie
FA FilmakademiePH Pädagogische HochschuleMANDA, RLP, SWITCH: Wissenschaftsnetze Darmstadt, Rheinland-Pfalz, Schweiz
BelWü-KoordinationUniversität Stuttgart
http://www.belwue.deFri May 09 2014
diversePeerings
100GE DWDM 10GE DWDM, Uni/Core-Netz (potentiell 100GE) 10GE DWDM, Uni/Core-Netz 10GE DWDM oder LWL, Hochschulen 10GE Bandbreite 10GE opt. Fenster über Versatel/RLP-Net 1GE LWL, 1GE Bandbreite, 155Mbit/s POS in Planung
RLP-Net
100G
Router (Name und Cisco Modell)Router (ggf. mit full-routing)fra1
9006
aal9006
Telia
S-IX
kommerzieller UpstreamInternet Exchange
DFN wissenschaftlicher Upstream
NeIF Netzwerk für Innovation und Forschung
KIT Campus Nord
KIT LSDF
URZ
LSDF
NeIF
NeIF
NeIF NeIF
NeIF
NeIF
NeIF
NeIF
NeIF
NeIF
NeIF
Stuttgart
Frankfurt
DE-CIX
Telia
man-schl-19010
Cogent
mos1001
MannheimHeidelberg
KarlsruheKIT
DFN
DFN
kar-rz-19010
kar-bib-19010
Uni Hoh
stu-al30-19010
stu-nwz-19010
ulm-n25-19010
ulm-n26-19010
Ulm
hlb9006
fra-decix-19006
kue9006
aal9006
hdh9006
sgd9006
ess9006
nue9006
reu9006
SWITCH
fdh9006
rav9006
wei9006
sig9006
alb9006
bib9006
kon-bib-19010
kon-rz-19010
hdl21001
shl1001
rot1001
loe1001
tue-wae-19010
tue-mor-19010
frb-rz-19010
frb-kg-19010
tut9006
tro9006
vil9006
fuw9006
hor9006
ofg9006
keh9006
OSIRIS
pfo9006
goe
gei
boe
fds
Freiburg Konstanz
Tübingen
Hohenheim
S-IX
bad1001
ras1001
Mosbach
HeilbronnKünzelsau
Schw. Hall
Schw. Gmünd
Aalen
Heiden-heim
Ludwigsburglbg-fa1001
FAPH
Pforzheim
Esslingen
Göppingen
Nürtingen
Geislingen
Reutlingen
Albstadt
Sigmaringen
Böblingen
HorbRottenburg
Freudenstadt
Kehl
Straßburg
Offenburg
Villingen -Schwenningen
Furtwangen
TuttlingenTrossingen
Kreuzlingen
Friedrichshafen
Ravensburg
Weingarten
Biberach
Rastatt
Baden-Baden
diversePeerings
diversePeerings
MANDA RLP-Net
Uni Hdl
Uni Man
Uni StuUni Ulm
Uni Tue
Uni Kon
Uni Frb
lbg-ph-19006
HS Ess
Level3
hdl-rz-19010
man-rz-19010
Ein Glasfaserpaar
9
BelWü Services
Services:
IPv4, IPv6
Firewalling (up to 1G, smaller Universities)
Layer 2 VPNs/Bandwidths
1/10G Ethernet over MPLS (via IP/MPLS Router)
10/100G Wavelengths (via DWDM; only few Hops)
10G Bandwidths (10x10G to 100G Mux, BelWü-NeIF)
With very different requirements ...
And of course a lot of Network related Servies ...
10
Ausblick 2014-2016+Outlook BelWü 2016+
11
12
(C) BelWü-Koordination (Universität Stuttgart), www.belwue.de
(Dieses Bild basiert auf dem Bild "Baden-Wuerttemberg location map.svg" aus http://commons.wikimedia.org
und steht unter der GNU-Lizenz für freie Dokumentation. Die Urheber sind Ssch, kjunix.)
Leitungen Plan 2016+ ?
Bandbreite (10GE) optisches Fenster existierende DF geplant
BelWü-KoordinationUniversität Stuttgart
http://www.belwue.deTue Jul 01 2014
Stand 12/2012
Standorte mit Universität Hochschule Anderer
25
96
42
26
58
5134
40
70
94
51
33
112
25
5015
45
3565
49
68
50
60
2040
23
76
30
42 Leitungslänge in km (ca.)
60
100
33
90
10028
60
50
110?
Böblingen
Freudenstadt
Rastatt
Baden-Baden
Rotten-burg
Biberach
Weingarten
Ravensburg
Friedrichshafen
Sigmaringen
Albstadt
Reutlingen
Nürtingen
Esslingen
GöppingenGeislingen
Heidenheim
AalenSchw. Gmünd
Künzelsau
Schw. HallHeilbronn
Mosbach
Ludwigsburg
Pforzheim
Kehl
Lörrach
Tuttlingen
Trossingen
V-SFurtwangen
HorbOffenburg
Gengenbach
PH FA
Frankfurt
Tübingen
Ulm
Konstanz
Freiburg
Karlsruhe
HohenheimStuttgart
Heidelberg
Mannheim
BelWü (Fiber) Footprint 2016 ???
100G IP Ports for clients at yellow dots
100G IP Routers at few central locations only
100G waves in the core network (red lines)
12
2014-2016+Tendering for:
1. Fibers (-only Network)
2. Optical Network
3. 100G IP Router (100G access for bigger Universities)
Potential Timeline:
13
Campus - ROADM static
14
Campus - ROADM dynamic
15
Statements / Questions
Buying 100G equipment starting end of 2015 seems to be a good time.
Smaller chips, more 100G port per line-card (optical and IP)
Fixed Questions:
Grid-less ROADMs - to have super channels in the future
(Dispersion Compensation must be aware of that!)
16
Statements / Questions (cont.)
Open:
Distribute ROADMs on two Locations on Campus ?
Dispersion compensation for long-haul 10G waves ?
Or only short-haul 10G waves (e.g., hop-to-hop) ?
(Re-use “old” 10G DWDM transceiver ?)
Big chassis or small chassis for each degree ?
Spectrum sharing w/ participants (“customer”) ?
We have that on some links today w/ static filters
(Swapping wavelengths with $ISP ?)
Less IP router, more latency between participants - problem ?
Is there wavelength rewriting ?
17
Challenge
Catch up your own team
We are new to ROADMs - that took us a while ...
No fancy/graphical NMS system
With optical equipment this would be mandatory ?
Necessary for tiering NOC structur (?)
We overcame ATM/SDH and other circuit switching
Now we are back to wavelength/OTN/Layer 2-VPN/etc. switching... ?
18
Questions ?
19
DWDM Karlsruhe - Offenburg
20
DWDM Karlsruhe - Offenburg
21
DWDM Karlsruhe - Offenburg
22
DWDM Karlsruhe - Offenburg
23
DWDM Karlsruhe - Offenburg
24