Behind the Danstoker-blue surface …. an introduction

18
A Thermax Group Company 1 Behind the Danstoker - blue surface …. an introduction Boilers since 1935

Transcript of Behind the Danstoker-blue surface …. an introduction

Page 1: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 1

Behind the Danstoker-blue surface….

an introduction

Boilers since 1935

Page 2: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 2

OIL / GAS BOILERS BIO- & SOLID FUEL BOILERS CO-GEN. BOILERS & WHRB

PRODUCT GROUPSFor Industrial, Commercial and District Heating

Page 3: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 3

Hot Water Boilers andHightemperatur Hot Water Boilers

•Capacities up to 50 MW•Max 32 bar

•Oil / Gas fired:Gas: Natural gas, Bio-gas, Landfill gas etc.

Oil: LFO and HFO as well as Bio- & Vegetable oil’s

Page 4: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 4

Danstoker Steam Boilers

•Capacities up to 50 t/h•Max 36 bar

•Oil / Gas fired:Gas: Natural gas, Bio-gas, Landfill gas etc.

Oil: LFO and HFO as well as Bio- & Vegetable oil’s

Page 5: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 5

CO-GEN. BOILERS & WHRB

Page 6: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 6

Danstoker Exhaustgas SteamBoilers

•Capacities up to 20 kg flue gas/sec.

AMD Energy Center Dresden 8+8 pc.

Avezzano, 9 pc.Texas Instrument, Italy

•Energy:From Engines, Turbines, Processes, Combustion etc.

Page 7: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 7

Examples: Design Co-gen Boilers

HW-boiler withHigh & Low Temp.

SectionSteam boiler

CompositeSteam boilerwith a Fired

and an Engine section

Page 8: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 8

BIO- & SOLID FUEL BOILERS

StrawPellets

Grain

Sawdust Bark

Wood-chips (wet or dry)

Page 9: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 9

Plant’s Block Diagram

Page 10: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 10

Steam boiler

HW - HTHW boiler

Examples: Design Bio-fuel Boilers

Page 11: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 11

Danstoker Bio-fuel Boilersfor Hot Water

•Capacities up to 20 MW•Max 16 bar

•Bio-fuels:Wood-chips (wet or dry), Straw, Pellets, Grain, Sawdust, Bark, Energy crops, Husks, Residue, etc.

Page 12: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 12

Danstoker Bio-fuel Boilersfor Steam

•Capacities up to 15 t/h•Max 32 bar

•Bio-fuels:Wood-chips (wet or dry), Straw, Pellets, Grain, Sawdust, Bark, Energy crops, Husks, Residue, etc.

Page 13: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company

Bio fuel boiler

Drawing of a boiler plant with a radiation part, a flue gas tube convection part and economizer

Page 14: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 14

Page 15: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company

Danstoker Biofuel Boilers

Ystad, Sweden:

District heatingPlant

Wood chips

Page 16: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 16

Installation ofthe Absorption Heat Pump

Page 17: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 17

GAS Inlet (or Auxiliary heat source)

Example :

The examples below are made on basis of a typical Danish district heating application with a rating (heat output) of 7 MW, combustion of wet wood waste with a humidity of 55%. Return temperature to the plant is 45 °C and a desired water flow temperature out of the boiler at 90 °C.

Example Design of the district heating plant Achietableefficiency

No. 1 Installation of a boiler with cooling of flue gases to 184 °C

84%

No. 2 Installation of a boiler + ECO for cooling of the flue gases to 120 °C

89,5%

No. 3 Installation of a boiler + ECO + Scrubber 1 for cooling of flue gases to 50 °C

110%

No. 4 Installation of a boiler + ECO + Scrubber 1 + Scrubber 2 + an AHP for cooling of flue gases to 25 °C

123%

This means that – when applying solution No. 4 - with the same heat input of 8332 kW you will achieve a heat output of 10284 kW from the district heating plant at a temperature of 90 °C.

Page 18: Behind the Danstoker-blue surface …. an introduction

A Thermax Group Company 18

Smart Energy of the future