7
05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 1/7 Installation & User's Instructions Integral 12 Hour AM/PM ElectroMechanical & 7 Day Electronic Timer Kits Kit N° 5118542 ElectroMechanical Kit N° 5118545 Electronic Please leave these Instructions with the User. Page 1 Fitting Instructions 1. Ensure that the electrical supply to the boiler is isolated. 2. Hinge the facia cover panel downwards (where fitted) and undo the screws retaining the facia/control panel. Hinge the facia/control panel down. 3. Maxflow WM Undo the screws from the locating pillars on the rear of the facia/control panel. All other models Undo the screws securing the timer cover panel and remove the panel. Remove and discard the clock blanking panel from the facia/control panel. 4. The timer wiring is integral to the boiler and connected to a terminal block. Discard the terminal block once the wiring is removed. Connect the black wires to terminals 3 and 4, blue to terminal 2 and brown to terminal 1 of the timer. Insert the timer into the control panel and secure with the cover (all except Maxflow) and screws previously removed (Fig . 1 ).

Transcript of Baxi Heating Uk-1

Page 1: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 1/7

Installation & User's Instructions

Integral 12 Hour AM/PM Electro­Mechanical & 7 Day Electronic Timer Kits

Kit N° 5118542 ­ Electro­Mechanical

Kit N° 5118545 ­ Electronic

Please leave these Instructions with the User.

Page 1

 

Fitting Instructions

1. Ensure that the electrical supply to the boiler is isolated.

2. Hinge the facia cover panel downwards (where fitted) and undo the screws retaining the facia/control panel. Hinge the facia/controlpanel down.

3. Maxflow WM Undo the screws from the locating pillars on the rear of the facia/control panel.

All other models Undo the screws securing the timer cover panel and remove the panel.

Remove and discard the clock blanking panel from the facia/control panel.

4. The timer wiring is integral to the boiler and connected to a terminal block. Discard the terminal block once the wiring is removed.Connect the black wires to terminals 3 and 4, blue to terminal 2 and brown to terminal 1 of the timer. Insert the timer into the controlpanel and secure with the cover (all except Maxflow) and screws previously removed (Fig. 1).

 

Page 2: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 2/7

Fig. 1

5. Hinge the facia/control panel back into position and resecure. Apply the label supplied in the kit to the space provided on page 2 ofthe boiler Users Operating Instructions.

6. Continue with the installation and commissioning of the appliance. Reinstate the electrical supply to the appliance. Set the clock asdescribed in the Users Operating Instructions opposite (Electronic) or on the back page (Electro­Mechanical) and according to therequirements of the user.

7. Instruct the user in the operation and setting of the timer.

IMPORTANT: When the boiler selector switch is in the '0' (Off) position the electrical supply to the boiler is isolated. The timermay require resetting once the boiler selector switch is set to either the DHW or CH mode.

Page 2

Integral 7 Day Electronic Timer Users Operating Instructions

Kit No. 5118545

Page 3: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 3/7

The timer has a total of 20 "storage spaces" for switching operations during one week. A switching operation will turn the boiler eitherON or OFF.

A particular operation can be used once only in the week, or in any of the four combination groups of days.

If, for example, the timer is set to turn the boiler on every day at 6.00a.m. it will only occupy one of the "storage spaces".

Before programming press the reset button with a pencil point or similar instrument. This clears the timer memory of unwantedinformation prior to programming.

Please note this is a 24 hour clock and hours should be set accordingly. The timer incorporates a back­up battery which will maintainstored programmes for up to 5 hours in the event of power supply interruption.

SETTING THE DAY AND TIME.

1. Press and hold the   clock button when performing the following operations (2 to 6).

2. Press the "Day" button to select the day. 1 is Monday, 2 Tuesday etc.

3. If setting during British Summertime press the "+/­ 1h" button. At the end of British Summertime press the button to adjust the hourbackwards. Pressing at the start of BST will advance the time one hour.

4. Press the "h" button to select the hour. Holding the button down changes the hour quickly.

5. Press the "m" button to select the minute. Holding the button down changes the minute quickly.

6. Release the   button. The colon between the hours and minutes will flash to indicate that the clock is working.

PROGRAMMING THE SWITCHING TIMES.

1. Press the "Prog." button to select the first free memory location.

2. Press the "Day" button to select which day or days on which the switching is required.Four groups of days are available:

Page 4: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 4/7

a) 1­7 Mon­Sun b) 1­6 Mon­Sat c) 1­5 Mon­Fri d) 6­7 Sat­Sun

Group a) covers the whole week. The groups c) & d) can be used together or with individual day programmes, and b) with an individualprogramme for Sunday.

Alternatively, each day can be programmed individually as in e) ­ Wednesday shown.

3. Press the "h" button to select the hour for the first switching operation. Fig. 2

 

4. Press the "m" button to select the minute for the first switching operation. Fig. 3

5. Press the   button once to select an ON   switching operation. Pressing the   twice selects an OFF   switching operation.

6. Press the "Prog." button to store the programme and select the next memory location. Set the next switching operation as describedabove.

7. When all switching operations have been set, pressing the "Prog." button once more after programming is complete will display theremaining number of memory locations, e.g. "Fr 16" indicates that four switching operations have been programmed, leaving 16 freememory locations.

8. Once programming is complete press the   button.

NOTE: If programming has been performed during an ON period, when the timer is reverted to the current time the boiler willnot be activated. It will be necessary to manually override the timer if heating is required immediately (see below). All furtherswitching operations will be activated as programmed.

MANUAL OVERRIDE

TEMPORARY OVERRIDE: The   button can be used to manually override the programme. The first press of the button switchesthe timer to ON during OFF periods ( ) and OFF during ON periods ( ). The remainder of the programme sequence is not affected.

CONTINUOUS OVERRIDE: Pressing the button twice will result in the timer programme to continuously ON (displayed [ ]).The thirdpress sets the programme continuously OFF ([ ]). To revert to the set programme press the   button again.

REVIEWING OR CHANGING THE PROGRAMME

Page 5: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 5/7

Press the "Prog." button repeatedly to view each programmed switching operation. To change any of the switching operations proceedas described above in "Programming the Switching Times".

See back page for 12 Hour AM/PM Electro­Mechanical Timer Users Operating Instructions

Page 3

Integral 12 Hour AM/PM Electro­Mechanical Timer Users Operating Instructions

Kit No. 5118542

The Electro­Mechanical Timer allows the central heating system to be set every 15 minutes.

Using the three position switch the timer will allow either constant operation, timed operation or central heating off.

Move the switch button by sliding to the desired position.

Three position switch (Fig. 4)

 

Page 6: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 6/7

Constant (Top position): The heating will be on constantlyirrespective of the position of the tappets. The heating will be

Page 7: Baxi Heating Uk-1

05/04/2013 www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm

www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/3330/I49-3330/I49-3330.htm 7/7

controlled by the main thermostat on the appliance and/or anyexternal controls.Timed (Central position): The heating will operate according tothe position of the tappets and be controlled as above.Off (Bottom position): No central heating. Domestic hot water willoperate on demand.

To set the time of day

Turn the timer outer bezel clockwise, to align the pointer with the correct time to the nearest 15 minutes ensuring that A.M./P.M. isconsidered.

Do not at any time attempt to turn the bezel anti­clockwise.

To set the timed heating program

Decide which times of the day the central heating is required.

The heating will operate when the white tappets are set to the outer edge of the bezel.

To ensure the heating stays OFF set the required tappets inwards towards the centre of the bezel.

Each tappet represents 15 minutes.

For example: If the heating is not required between 10 A.M. and 11 A.M. the four tappets anticlockwise from the 10 A.M. will be setinwards (Fig. 5).

BAXI Heating UK

Brownedge Road Bamber Bridge Preston Lancashire PR5 6SNAfter Sales Service 08706 096 096 Technical Enquiries 08706 049 049Website www.baxi.co.uk

A BAXI GROUP company

Comp N° 5118971 ­ Iss 1 ­ 4/06