Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds...

25

Transcript of Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds...

Page 1: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.
Page 2: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.
Page 3: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Based on mechanical construction

• Closed: Shrouds or sidewall

enclosing the vanes. • Open: No shrouds or wall to enclose

the vanes. • Semi-open or vortex type.

Page 4: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Closed Impeller

• The vanes are large, rounded leading edges to prevent clogging by rags and stringy material that could become entangled at the vane entry.

• On pump with 12” has two vane design is typical while larger pump may utilize three or four vane design.

• The straight vane keep the sealing area free of debris and also reduce the unbalance axial force that can occur due to back shroud’s large surface area.

Page 5: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• Another characteristic close impeller that diameter seldom exceeds 80% of the volute cut water diameter compared 92% standard impeller.

• This diameter order to reduce vibration and noise especially at the lower flows.

• This diameter also reduces clogging in the area where the impeller is closest to the volute case.

Page 6: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Closed Impeller

Page 7: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Closed Impeller

Page 8: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• Thousand of pump operate with open impellers and some pump designs have even standardized on these open-impeller pumps.

• Open face impellers are popular because the cost less money to manufacture so the pump cost less.

• Unfortunately these pumps cost more to operate and wear more quickly.

Open impeller

Page 9: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• The pump usually seen in smaller pumps and are best suited for applications involving stringy material.

• Because they are shroud less and become disadvantage in the structural weakness and because of this they are often to strengthened by a partial shroud on the back side.

• If the back shroud cover covers the entire vane structure, the impeller is designated as semi open impeller.

Page 10: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Open and Semi Open Impeller

Page 11: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Open impeller

Page 12: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Open impeller

Page 13: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Close and Open Impeller

Page 14: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Semi-open Impeller

• The semi open impeller, due to its lack of a front shroud, also tends to create greater unbalanced axial force than does the closed impeller.

• Both pump out vanes and balance hole are often utilized to minimize these forces and prevent potential bearing damage.

Page 15: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Semi-open Impeller

Page 16: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.
Page 17: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Centrifugal Pumps Groups

• Centrifugal pumps can be classified in three major groups depending on their design and application:

1. Volute pumps

2. Diffuser pumps

3. Turbine pumps

Page 18: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Volute pumps

Page 19: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• A centrifugal pump (which is also referred to as a booster pump) is often used to pump surface water (or shallow well water) or to increase the irrigation systems pressure.

• The housing of the centrifugal pump that is spiral-shaped, with the diameter of the flow passage increasing toward the discharge point is called a volute pump.

• The volute pump is the most common type of radial-flow centrifugal pump. It has an impeller housed in a progressively widening spiral casing as shown in Figure 9.2 .

Page 20: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.
Page 21: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• Water enters the eye of the impeller and is thrown radial outward.

• Volute pumps can be single-suction or double-suction pumps.

• A single-suction pump impeller is exposed to a large axial hydraulic thrust resulting from the unbalanced hydraulic pressures on the impeller.

• In a double-suction pump, water is fed from both sides of the impeller, significantly improving its hydraulic balance. As a result, double-suction volute pumps can produce higher pressures than single-suction pump

Page 22: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• Volute pumps are commercially available as single-stage (single impeller) or multistage (multiple impellers) pumps.

• The most common reason for the multi-stage configuration is to increase the head produced by the pump.

• If a multi-stage pump has single suction impellers, the impellers are usually arranged with equal numbers discharging in opposite directions to counteract the hydraulic imbalance on each of the impellers.

• Volute pumps are used where irrigation water is obtained from depths generally less than 20 feet, The exact value of possible lift is determined by the net positive suction head required by the pump.

Page 23: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Diffuser pumps

Page 24: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

• In a diffuser-type centrifugal pump, the impeller is surrounded by a ring of fixed diffuser vanes that provide enlarging passages in which the velocity of the water leaving the impeller is reduced and as a result pressure is increased.

• The diffuser vanes provide a more controlled flow and allow for a more efficient conversion of velocity into pressure than volute pumps since the change from velocity to pressure takes place gradually.

• Diffuser pumps, especially large ones, often have efficiencies over 90 percent.

• Diffuser pumps have the additional advantage of a balanced radial loading on the impeller, which reduces the chance of shaft failure due to fatigue.

Page 25: Based on mechanical construction Closed: Shrouds or sidewall enclosing the vanes. Open: No shrouds or wall to enclose the vanes. Semi-open or vortex.

Centrifugal pump diffuser