Balloon Atrioseptostomy Catheters -...

2
Balloon Atrioseptostomy Catheters These catheters, engineered for maximum steering and tracking, have micro-thin balloons which do not distort during pullback, allowing the balloon size to be smaller than competitive catheters

Transcript of Balloon Atrioseptostomy Catheters -...

Page 1: Balloon Atrioseptostomy Catheters - bisusa.orgbisusa.org/sites/bbrauninterventionalsystems.com/files/documents/...• Dual lumen shaft design provides pushability coupled with exceptional

Balloon Atrioseptostomy Catheters

These catheters, engineered for maximum steering and tracking, have micro-thin balloons which do not distort during pullback, allowing the balloon size to be smaller than competitive catheters

Page 2: Balloon Atrioseptostomy Catheters - bisusa.orgbisusa.org/sites/bbrauninterventionalsystems.com/files/documents/...• Dual lumen shaft design provides pushability coupled with exceptional

Balloon Balloon Recommended Shaft Shaft Maximum Recommended Product Reorder Diameter Length Introducer Size Size Usable Inflatiom Guidewire Code Number (mm) (cm) (Fr) (Fr) Length (cm) Volume (cc) (In)

SPT-003 611100 13.5 1.35 6 5 50 2.0 0.021

SPT-002 611200 9.5 0.95 5 4 50 1.0 0.014

• Catheter is engineered for maximum steering and tracking

• Dual lumen shaft design provides pushability coupled with exceptional pull strength

• Catheter end hole can be utilized for a guidewire, contrast injection or blood analysis

• The balloon is micro-thin for a low deflated profile that maintains tip flexibility;

this exceptionally low profile requires a small introducer sheath

• Material is the same as that used in Tyshak™ and Z-Med™ balloon catheters

• The reduced balloon size is ideal for septostomy in the neonate with a small left atrium

• The shape of the spherical balloon does not deform during pullback, allowing the balloon size to be

smaller than competitive catheters

• Catheter tip is angled at 35 degrees to facilitate passage into the left atrium

Balloon Atrioseptostomy Catheters

For more information or to place an order, contact your B. Braun Interventional Systems Inc.representative or call 1-877-VENA-CAV (836-2228)

Manufactured for:B. Braun Interventional Systems Inc.824 Twelfth AvenueBethlehem, PA 18018Tel: 1-877-VENA CAV (836-2228)Fax: 610-266-3982www.bbraunusa.com

Manufactured By:NuMED, Inc.2880 Main St.Hopkinton, NY 12965

Components and packaging do not contain natural rubber latex

LATEX

DEHP freeDEHP

Rx only©2011 B. Braun Interventional Systems Inc.CV964 - 3/11