![Page 1: Automation that Fits. Power Link - medist-srl.ro · Automation that Fits. Power Link Beckman Coulter introduces the new Power Link ... of shared clinical samples streamline clinical](https://reader034.fdocuments.net/reader034/viewer/2022042302/5ecdb7f48182b53df94d6ddd/html5/thumbnails/1.jpg)
DS-16228A NotfordistributionintheU.S.
AutomationthatFits.
PowerLink
BeckmanCoulterintroducesthenewPowerLink,whichnowofferslaboratoriestheabilitytocombineanAU680ChemistryAnalyzerwithaDxIImmunoassayAnalyzertoformanentry-levelautomatedworkcell.Thissolutionsupportsparallelprocessingofsharedchemistryandimmunoassayspecimensat200tubesperhourandisforallclinicallaboratoriesthatplaceapremiumonreliabilityandreductionofbiohazardrisk.
Features and benefits:
• Onlinereruncapabilityandparallelprocessingofsharedclinicalsamplesstreamlineclinicallaboratoryworkflow.
• Singletubemanagementminimizeswait-timetodealwitherrorsandexceptions.
• Largevarietyoftubesizes,diametersandcap-typesfitsmostcustomerrequirements.
• Integrateddecapperminimizesbiohazardexposureriskandrepetitivemotioninjuries.
Blood Banking
Centrifugation
Chemistry
Flow Cytometry
Hematology
Immunoassay
Information Systems
Lab Automation
Molecular Diagnostics
Rapid Diagnostics
AU680 Power Link UniCel DxI 600 or 800
![Page 2: Automation that Fits. Power Link - medist-srl.ro · Automation that Fits. Power Link Beckman Coulter introduces the new Power Link ... of shared clinical samples streamline clinical](https://reader034.fdocuments.net/reader034/viewer/2022042302/5ecdb7f48182b53df94d6ddd/html5/thumbnails/2.jpg)
Specifications
ForBeckmanCoulter’sworldwideofficelocationsandphonenumbers,pleasevisitwww.beckmancoulter.com/contactB2011-12745 www.beckmancoulter.com ©2012BeckmanCoulter,Inc.
BeckmanCoulter,thestylizedlogo,AU,andDxIaretrademarksofBeckmanCoulter,Inc.andareregisteredwiththeUSPTO.
Depth(drawerclosed) 40in(100cm)
Depth(draweropened) 66in(168cm)
Width 79in(200cm)
Height 59in(150cm)
Weight 551lbs(250kg)
Heat 16946BTUs/hour
Sound LwA<74dBA
With single point of loading and unloading for your shared chemistry/immunoassay samples, Power Link enables you to rapidly process your patient samples.
Featuring a combined 200 tube inlet/outlet as well as a 10-position priority-load area, Power Link delivers high-capacity specimen processing power and flexibility to meet your laboratory workload challenges.
Suggested sample tubes for the PowerLink system include: BD or Greiner: 13x75 mm or 13x100 mm sizes. Contact your Beckman Coulter representative for additional sample tube details.