OUR OBJECTIVES
1. Identify fire protection systems and devices
and describe procedures to validate their
operational readiness.
2. Determine the components of Fire Protection
systems.
3. How do we Audit our Fire Protections
System.
4. Define fire alarm systems.
5. Define Total Flooding systems, and local
applications System.
![Page 3: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/3.jpg)
Agenda
1. Introductions
2. Basic Component
3. System Overview
4. ENGR Audit Report
![Page 4: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/4.jpg)
Introductions
Under the rather broad heading of fire protection
systems, this module will examine the main
components of alerting, suppression, and
containment features and systems. Consideration
of these systems is a natural adjunct to a
discussion of hazards and building construction
features.
The primary components we will examine are fire
alarm systems, fire detection and notification
systems, suppression agents and systems,
standpipe and hose systems, and portable fire
extinguishers. This module will cover a lot of basic
material meant to provide the basic audit to our
existing Fire Protections system.
![Page 5: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/5.jpg)
Fire Alarm Systems
Purpose of Fire Alarm Systems
A properly designed, installed, operated, and maintained fire alarm
system can reduce the losses associated with an unwanted fire in any
building. These losses include property and, more importantly, human
life. The primary motivation for fire alarm system requirements in
building and fire codes is to provide early notification to building
occupants so they can exit the building, and to notify the fire service so
it can respond to the fire. In settings such as hospitals the fire alarm
system provides notification to staff so they can respond to the fire
emergency (as opposed to evacuating the building). This module will
explain the basic features of fire alarm systems and the inspection of
these systems. It should be noted that fire alarm systems also are
called "protective signaling systems," especially in NFPA documents
and in other codes and standards.
![Page 6: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/6.jpg)
Basic Components of a
Fire Alarm System
Double
Flashing Light
Smoke Detector
Beacon/Sounder Strobe Light Manual Pull
Stations
Heat Detector
Electrical
• Control Panel
• Smoke Detector
• Heat Detector
• Manual Pull Stations
• Sounder (Audible)
• Beacon Light (Audible & Visual)
• Strobe Light (Visual)
• Double Flashing Light
Control Discharge Panel Surge Protector AC/DC
Grounding for Control Panel
![Page 7: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/7.jpg)
Basic Components of a
Fire Alarm System
Sch 40 Piping
Cylinder Flexible Hose Manifold
Solenoid Valve
(Actuator)
Mechanical
• Cylinder (Gas)
• Flexible Hose
• Manifold
• Piping
• Nozzle
• Solenoid Valve (Actuator)
Nozzle
![Page 8: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/8.jpg)
PPU - System Overview
Battery Room Fire Alarm Panel
ZONE 1
ZONE 2
ZONE 3
ZONE 4
CH 1
CH 2
CH 1
CH 2
Cable Cellar Room Fire Curtain
Control Discharge
Panel
Control Room
Switchgear Room
Control Discharge
Panel
Stage 1 – Pre Discharge Mode
Bell Intermittent Tone
Green Flashing light Blinking
(Holding time 30 sec before discharge)
Stage 2 - Discharge Mode
Strobe Light Blinking
Sounders Alert Tone
Red Light Permanent On
![Page 9: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/9.jpg)
Audit Diagram
Final Reports
ENGR 5215 PSI
ENGR 5211 PSI
ENGR-750-37- QR01
ENGR-750-37- QR02
ENGR-750-54- QR01
TNBD System Audit
ENGR 5212 PSI
ENGR 5213 PSI
PROJECT PLANNING
![Page 10: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/10.jpg)
ENGR-PSI-FORM
5211-PSI 5212-PSI 5213-PSI
FIRE ALARM & DETECTIONS GAS CONTROL SYSTEM AITOMATIC GAS FLOODING
SYSTEM
SENARAI SEMAK PEMERIKSAAN DAN PENGUJIAN
13 Test 6 Test 5 Test
![Page 11: Audit training](https://reader038.fdocuments.net/reader038/viewer/2022100506/54c8bdc84a79592a348b45b7/html5/thumbnails/11.jpg)
PROSES PENGISIAN BORANG ENGR-750-37
( QR1 DAN QR2 )
ENGR-750-37
JENIS
PENCAWANG
PERANCANGAN
TARIKH
SENGARAAN
JENIS
MEDIA/AGEN
UNTUK
PEMASANGAN
BARU
AUDIT
KEROSAKAN
KEJANGGALAN