Attain Highly Accurate & Stable Speed Measurement · External KP Input Sub Display Dimmer POWER...
Transcript of Attain Highly Accurate & Stable Speed Measurement · External KP Input Sub Display Dimmer POWER...
Attain Highly Accurate &Stable Speed Measurement
Better StabilityWith the new transducer and newly designed process algorithm,the impact of foam is reduced, enabling highly accurate and stableship speed information.
Highly Accurate Measurements
▶Development of a transducer equipped with the latest technology ①Usage of a high frequency with a strong foam resistance ②Achievement of an optimal ultrasonic width and angle▶Significant improvement of the signal processing capability
Improved Interference Immunity Comparison between the DS-80 valve (40kg)and the DS-85 valve (27kg)
When a vessel moves through the water, acoustic noise is created and is known as a boundary layer. This noise layercan cause errors with acoustic devices. By measuring speed through water (STW) farther away from the keel, the DS-85penetrates through this noise and boundary layer resulting in a more stable and accurate speed measurementcompared to an electromagnetic speed log.
Easy-to-Read DisplayEasy-to-read display screen evenfrom a distance, thanks to large characters and clear, bright tones
Compact Gate Valve (Option)
Boundary Layer
Ship Speed Measurement Water Depth : 3m or deeper under the keel
The new compact and lightweight ball-type gate valve is30% lighter than the traditional valve. When replacingthe previous model (DS-80), the same tank or valve canbe used, reducing the cost of a retrofit.
Model: DS-85
Measurement Image
www.furuno.com
Complies with the latest IMO, IEC StandardsIMO A.694(17) IEC61023 Ed.3.0IMO A.824(19) IEC61162-1 Ed.5.0IMO MSC.36(63) IEC61162-2 Ed.1.0IMO MSC.97(73) IEC61162-450 Ed.2.0IMO MSC.191(79) IEC62288 Ed.2.0IMO MSC.302(87) IEC60945 Ed.4.0 IEC62923-1/-2 Ed.1.0
Specifications Equipment
InterconnectionDiagram
DimensionsDisplay Unit DS-8500
Transceiver Unit DS-8520
Hanger 0.7 kg 1.5 lb
6 kg 13.2 lb
Gate Valve DS-786 40 kg 88.2 lb Ball Type Gate ValveDS-854
27 kg 59.5 lb
Distribution Unit DS-8510 13 kg 28.7 lb
Flushmount (Option) 0.6 kg 1.3 lb
4.3 inch Color LDC WQVGA
under 0.1cd/m2
over 600cd/m2
18 Levels
Ship Speed and Distance Screen, Ship Speed Screen,
Distance Screen, Analog Meter Screen
English, Japanese
Serial Input
Serial Output
Ethernet
External KP Input
Sub Display
Dimmer
POWER FAIL Output
SYSTEM FAIL Output (Option)
Analog Output (Option)
Log Pulse Output (Option)
Display Unit
Distribution Unit
Transceiver Unit
Transducer
Display Unit
Distribution Unit
Transceiver Unit
Display Unit
Distribution Unit
Transceiver Unit
Transducer
IEC 60945 Ed.4.0
2 Ports
(IEC 61162-1/2x1, IEC 61162-1x1)
8 Ports
(IEC 61162-1/2x1, IEC 61162-1x7)
1 Port (IEC 61162-450)
1 Port
2 Ports
1 Port
1 Port
1 Port
4 Ports
1 Port
-15℃ to +55℃
-5℃ to +35℃
93 % (+40℃)
IP22
(IP35 with Waterproog Kit Installed)
IP22
(IP20 with Tabletop Mount)
IP44
IPX8
LCD
Minimum Brightness
Maximum Brightness
Brightness Adjustment
Display Mode
Display Language
No. of Ports
Temperature Range
Relative Humidity
Protection Rating
Vibration
Product NameNumber of Transceiver BeamsTransmission FrequencyMeasurement Speed RangeDistance Measurement RangeShip Speed Measurable Water DepthOutput Ship SpeedShip Speed Measurement AccuracyDistance Measurement AccuracyPower SupplyDisplay Unit
Interface
Environment
Display Unit
Distribution Unit
Transceiver Unit
Transducer
Installation Material,
Accessories, Spares
Sub Display
Analog Display
Range Switch for Analog Display
Dimmer for Analog Display
Dimmer
DS-8500
DS-8510
DS-8510-LIF*
DS-8520
DS-8530
DS-8500
RD-50
RD-20
SL-200
FL-200S
DS-389
MF-22R
DS-F25
DS-FE25
DS-S25
DS-SE25
RD-502
Remote Control Unit
Junction Box
Ship Bottom Tank : Protrusion Type
Ship Bottom Tank : Buried Type
Ball Type Gate Valve
Gate Valve
LIF Board Kit
Front Fastening Panel
F Mount Sponge Kit
Waterproof Kit
Replacement Kit
SC Lock
Cable Assembly
Cable Protection Kit
Installation Material
RD-501*
* for RD-50/20
CI-630
DS-781
DS-784
DS-854
DS-786
OP65-3
OP24-35
OP05-141
OP05-139
OP05-140
OP65-4
OP05-146
OP05-147
Standard
Options
175
160
175
330
13.
0"
348 13.7"
20 0.8"
AnalogDisplay
LIF Board*2
Sub Display Output
Log Pulse Output
Analog Output
System FailOUT
PowerFail OUT
Sub Display Output
Dimmer Input
Sub DisplayDS-8500/RD-50*1/20
Sub DisplayDS-8500/RD-50*1/20
100-115/200-220 VAC
*3
*3
DimmerRD-502Junction Box
CI-630
IEC61162-1/2
LAN IEC61162-450
DS-8520
TransceiverUnit
DS-8510Distribution Unit
DS-8500Display Unit
Cable Lenght:Max 50m
Cable Lenght:10/20/30/40m
DS-8530Transducer
NavigationSystem
NavigationSystem
Navig.System
Navig.System
EXT KPIN
Ext. KP
Navigation System
Dimmer
400
15.
8"
355±1 14.0"
12.5
0.5
”
350
13.
8"
404
15.
9"
130 5.1"
375±
1 1
4.8"
3 0.1"2xø7
26.5
1.0
"
355±1 14.0"
7
2xR3.5
172 6.8"
146
5.8
"
125
4.9
"
145 5.7"
74 2.9"
30°
21±3 0.8"
154±
5 6
.1"
107 4.2"
Packing for Cables(Option)
110
4.3
"
145 5.7"
125
4.9
"
12 0.5" 62 2.4"4xø3.5 95 3.7"
Packing for Cables(Option)
Mounting Holes
HULL PLATE
ø175ø180
(330
13.
0")
210
8.3
"(1
86 7
.3")
30 1.2"
1.5
0.1"
516
20.
3"
(136
.5 5
.4")
(260
10.
2")
107 4.2"(53 2.1")
90 3
.5"(2
60 1
0.2"
)
(160 6.3")247 9.7"
(100
.5 4
.0")
1.5
0.1"
ø175
90°
BOW
315±1 12.4"
350 13.8"
95.5
3.8
"
4xR5
122 4.8"
315±
1 1
2.4"
442
17.
4"
StandardConfigurationOptionor On-site Arrangement
*1 When connecting two RD-50, use the power supply onboard. The Distribution Box can only supply power to one device.*2 For the DS-8510-LIF, the LIF board con�guration is standard.*3 The cable lenght (Distribution Box to Tranceiver Box) is up to 400m. If necessary, use the Junction Box.
RangeSwitch
* The Speci�cations are when the LIF board is mounted. When using the Analog Output, the Log Panel Output or the System Fail, the LIF board is necessary.
FURUNO ELECTRIC CO., LTD.Japan | www.furuno.com
FURUNO U.S.A., INC.U.S.A. | www.furunousa.com
FURUNO PANAMA S.A.Republic of Panama | www.furuno.com.pa
FURUNO (UK) LIMITEDU.K. | www.furuno.co.uk
FURUNO NORGE A/SNorway | www.furuno.no
FURUNO DANMARK A/S Denmark | www.furuno.dk
FURUNO SVERIGE ABSweden | www.furuno.se
FURUNO FINLAND OYFinland | www.furuno.�
FURUNO POLSKA Sp. Z o.o.Poland | www.furuno.pl
FURUNO DEUTSCHLAND GmbHGermany | www.furuno.de
FURUNO FRANCE S.A.S.France | www.furuno.fr
FURUNO ESPAÑA S.A.Spain | www.furuno.es
FURUNO ITALIA S.R.L.Italy | www.furuno.it
FURUNO HELLAS S.A.Greece | www.furuno.gr
FURUNO (CYPRUS) LTDCyprus | www.furuno.com.cy
FURUNO EURUS LLCRussian Federation | www.furuno.ru
FURUNO SHANGHAI CO., LTD.China | www.furuno.com/cn
FURUNO CHINA CO., LTD.Hong Kong | www.furuno.com/cn
FURUNO KOREA CO., LTDKorea
FURUNO SINGAPORESingapore | www.furuno.sg
PT FURUNO ELECTRIC INDONESIAIndonesia | www.furuno.id
FURUNO ELECTRIC (MALAYSIA)SND. BHD.Malaysia | www.furuno.my
B-2010BCCatalogue No. CA000001480
Doppler Speed Log
2 Beams
2 MHz
-40.0 to +40.0kn (Longitudinal Direction)
0.00 to 999999.99NM
3m or deeper below Ship Bottom
1-axis to Water Speed
±1% or ±0.1kn (larger of the two)
±1% or ±0.1NM (larger of the two)
100-115 VAC:0.6 A / 200-220 VAC:0.4 A