ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 ›...

22
ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS

Transcript of ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 ›...

Page 1: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

ATHERTON RANGEHOOD INSTALLATION

INSTRUCTIONS

Page 2: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

2 Rangehood Installation Instructions

Page 3: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 3

Important Information 4

Instructions for Models 6

SOMERTON / AVENEL / STIRLING

Instructions for Models PENINSULA 13

Remote Switching Specifications 15

Ducting Pieces 17

Cleaning 19

Guarantee & Exclusions 20

Warranty 23

Page 4: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

4 Rangehood Installation Instructions

IMPORTANT INFORMATION It is important to follow the installation instructions for different models. The following is general advice for the installation of ATHERTON Rangehoods. ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the barbecue. 1. The installation of ATHERTON Rangehoods must comply with the information in this booklet.

ATHERTON Rangehoods are designed and made to work efficiently over all domestic barbecues available on the Australian market.

2. Every ATHERTON Rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or non-porous and non-flammable materials. We do not recommend the use of any type of flexible ducting or plastic PVC piping (barbecue heat output will affect flexible ducting and cause it to disintegrate). Rangehoods must not be vented into a wall cavity or a ceiling space. This prevents a build-up of grease, which can be a fire risk. Ensure the external outlet vent does not restrict the airflow in any way, as this may result in reduced performance.

3. ATHERTON Rangehoods must be ducted in duct work equivalent to the outlet of the rangehood i.e.: The cross-sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from CONDARI is available to ensure optimum performance. Always use non-flammable materials to minimise the risk of fire in the duct.

4. Ensure all ducting pieces are correctly fitted and sealed with either duct tape or silicone to ensure that fumes do not escape into the ceiling space and seep into living areas through vents or light fittings. The installation and fitting of the rangehood should be done in such a way that will allow the unit to be removed if service is required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not covered by warranty.

5. Always adequately ventilate the room when the rangehood is in use at the same time as appliances burning gas or other fuels.

Page 5: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 5

6. WARNING: Incorrect venting will result in additional noise and a reduction in efficiency. Exhaust air must

not be discharged into any chimney or flue, which may carry combustible products from other sources

a) Do not discharge the airflow from the rangehood into a flue used for exhausting fumes from burning gas or fuel;

b) A reduction in ducting size will result in the motors eventually failing and will need replacement. c) For cleaning purposes please refer to page 19 of installation instructions for stainless steel; d) If cleaning is not carried out in accordance with the instructions as listed on page 20, you

may have an increased risk of fire; e) Accessible parts of the rangehood may become hot when used with cooking appliances; f) This appliance is not intended for use by persons (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

7. If the supply cord is damaged, an authorised service centre or licensed electrician must replace it.

8. NOTE: We recommend 2700 cubic metres per hour over a barbecue, depending on the length of the duct run. Barbecues should be positioned under the centre of the hood where the fans are mounted and not near the outer edges where leakage may occur. Please also note barbecue lid position, as if it does not open to a 90 degree angle the smoke and by-products can be diverted forward and away from the rangehood catchment area.

9. The lights in the rangehoods are LED.

10. To reduce the risk of fixing screws coming in contact with live parts, do not drill or screw into the rangehood. Live wires are encapsulated where possible to prevent user contact. If necessary, drill from the inside out and only through single sheet material.

11. CONDARI PTY LTD can manufacture rangehoods to be used over commercial cookers in domestic applications.

NOTE: Installation must comply with local State & Council regulations.

Page 6: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

6 Rangehood Installation Instructions

INSTALLATION INSTRUCTIONS Somerton, Avenel & Stirling Models. 1. Determine hood position on wall 1200mm to 1400mm above barbecue.

2. Unpack Rangehood.

3. Mark centre line on wall.

4. Mark base line on wall (Note: if shroud being used, the height of the shroud will determine the height of the hood).

5. Mark the outlet hole in the ceiling for the flue and cut out, removing any obstructions allowing clear access for the flue (Note: if using rear duct, mark and cut hole at this time).

6. Drill fixing holes in rear of hood to suit available fixing points on wall making sure to get fixing as high and as wide as possible in Rangehood to avoid sagging from wall. (Please refer to Rangehood diagram for example of possible fixing points)

7. Fix to wall at base height of hood making sure this is level and exactly central.

8. Transfer fixing locations from hood to wall and drill fixing holes. Insert plugs to allow or use dyna bolts as an alternative.

9. Locate position for power cable and drill hole for cable using a hole saw. Consult your electrician for his preferred location.

10. Fit stainless flue to top of hood with 4 supplied fixing screws while hood is on ground to avoid having to drop stainless flue down through hole in the ceiling and causing possible damage to the flue. (If using a shroud, it can be fitted either at this stage or carefully after hood is on wall)

11. Remove fans if needed and lift hood up onto mounting bracket carefully guiding flue through hole in ceiling and bringing power cable into hood during this process. You will require up to 3 people for this lifting stage as hood is quite awkward and heavy to lift.

12. Screw or bolt hood to wall securely making sure hood is level and sitting properly on mounting bracket. It is advisable to have portable stands ready for this stage as hood will get quite heavy.

13. Refit perforated panel in the rear or the hood and refit fans if they have been removed.

14. Make electrical connection to junction box inside bottom right side of hood. For Remote Switching Rangehoods please refer to page 15 & 16 for wiring information.

15. Extend ducting through roof to exterior and fit roof cowl making sure to seal roof penetration with preferred flashing material. (Note: there are several on the market to suit the type of roof you have, so consult your plumber for the best product to suit).

Page 7: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 7

INSTRUCTIONS TO CHANGE THE ORIENTATION OF THE RANGEHOOD OUTLET PLATE.

Instructions to change the orientation of rangehood outlet plate from top ducted to back ducted or vice-versa.

1. Locate and remove 12x M4 screws as shown below. 2. Once all screws are removed, push rangehood outlet plate from the inside of the rangehood

outwards. 3. Reorient rangehood outlet plate from top to back ducted or vice-versa, relocate back into rangehood

and replace 12x M4 screws removed earlier.

Page 8: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

8 Rangehood Installation Instructions

DIAGRAM SHOWING RANGEHOOD OUTLET PLATE IN TOP DUCTED AND BACK DUCTED POSITIONS.

Top Ducted Orientation as Supplied

Optional Back Ducted Orientation

Page 9: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 9

Page 10: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

10 Rangehood Installation Instructions

Page 11: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 11

Page 12: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

12 Rangehood Installation Instructions

Page 13: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 15

REMOTE SWITCHING SPECIFICATIONS 3 FAN (no lights)

1. Wiring to the appliance must comply with State and local regulations.

2. Switching is not provided with Remote Switched Rangehoods.

3. You may use any approved switching to connect the rangehood (e.g. Clipsal switches).

4. All fans must be controlled by at least one ON/OFF and one HI/LO switch.

5. Please refer to Wiring Diagram below for detailed wiring information.

WIRING DIAGRAM NOTE: This diagram is for reference only. A qualified electrician must connect remote switching to rangehood. Reflected in this drawing is the most common method of connecting the rangehood. Be aware that Active voltage must NOT be applied to both the ‘Black-High’ and ‘Brown-Low’ wires at the same time. This will cause the fan to fail.

Page 14: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

16 Rangehood Installation Instructions

REMOTE SWITCHING SPECIFICATIONS 3 FAN with LED

1. Wiring to the appliance must comply with State and local regulations.

2. Switching is not provided with Remote Switched Rangehoods.

3. You may use any approved switching to connect the rangehood (e.g. Clipsal switches).

4. All fans must be controlled by at least one ON/OFF and one HI/LO switch.

5. Please refer to Wiring Diagram below for detailed wiring information.

WIRING DIAGRAM NOTE: This diagram is for reference only. A qualified electrician must connect remote switching to rangehood. Reflected in this drawing is the most common method of connecting the rangehood. Be aware that Active voltage must NOT be applied to both the ‘Black-High’ and ‘Brown-Low’ wires at the same time. This will cause the fan to fail.

Page 15: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 17

DUCTING All ducting pieces are available in zincalume, stainless steel colourbond material or powderkote colour.

400. DL-4

401. HB-450X250 DL-4 S/S HB-450X250 S/S DL-4 C/P HB-450X250 C/P

402. VB-450X250

403. HB-450X250/45 VB-450X250 S/S HB-450X250/45 S/S VB-450X250 C/P HB-450X250/45 C/P

404. VB-450X250/45

405. BD/WV-H-450X250 VB-450X250/45 S/S BD/WV-H-450X250 S/S VB-450X250/45 C/P BD/WV-H-450X250 C/P

Page 16: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

18 Rangehood Installation Instructions

406. BD/WV-V-450X250

407. RCB BD/WV-V-450X250S/S RCB S/S BD/WV-V-450X250C/P RCB C/P

408. RCBA

409. WVC-H-450X250 RCBA S/S WVC-H-450X250 S/S RCBA C/P WVC-H-450X250 C/P

410. WVC-V-450X250

411. BD RC-4 WVC-V-450X250 S/S BD RC-4 S/S WVC-V-450X250 C/P BD RC-4 C/P

Page 17: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 19

FILTER CLEANING For the best results, please clean filters regularly. Condari recommends cleaning filters every 3-4 weeks, or immediately after heavy use. You can do this by hand washing in warm soapy water, or by placing filters in the dishwasher. Condari does not recommend the use of any citrus or caustic products as this can cause corrosion on the metal filters.

RANGEHOOD CLEANING

Our Rangehoods are made from stainless steel, either type 304 or type 316.

• Type 304 is classified as 18/8 stainless steel • Type 316 is classified as 18/10 stainless steel.

This means that the stainless is made of 18% nickel and either 8% or 10% of chromium respectively. Stainless steel gets its protective coating from the chromium oxidising in the air to form a protective surface of chromium oxide. This protective surface can be attacked by salt in the air and by salt water, and then corrosion can occur on the steel. It is important to clean and polish the stainless steel by hand, allowing the chromium to oxidise again. Therefor if the alfresco area is by the sea, one should take measures to protect the rangehood from corrosion. It is suggested to wipe the hood down with vegetable oil if it is left in the open for long periods of time.

Page 18: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

20 Rangehood Installation Instructions

CONDARI PTY LTD APPLIANCE GUARANTEE The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product which the consumer has under the Trade Practices Act and similar state and territory laws. Condari P/L in Melbourne (and by their agency in Country Areas and other States) warrants that the appliance will be free from defects in materials and workmanship for a period of 36 months from the date of purchase of the appliance to the consumer. If there is a breach of this warranty, Condari will rectify, free of charge, at it’s nearest service centre or authorised service agency any fault caused by faulty workmanship or material at the time of manufacture occurring in the appliance within 36 months from the date of delivery of the appliance to the customer. This warranty is conditional upon the appliance being used only for personal, domestic and household purposes and installed and operated in accordance with the Instructions and does not apply to articles which by their nature are consumable. If a defect is caused by neglect, misuse, or failure to follow operating instructions where special precautions are detailed for user attention then a charge shall be made for the service call. For example: With the filters the user is specifically requested: • To clean filter regularly by handwashing or placing in a dishwasher at least once a

month. • To turn off after each use. Where a claim is made under warranty, we reserve the right to determine whether or not the fault is caused by faulty workmanship or material or that the part is defective. The consumer shall be fully responsible for all expenses whatsoever incidental to the removal of parts from the unit or to their replacement. Inter alia, such responsibility shall extend to damaged walls, tiles, fixtures and fittings whether or not the unit has been built into a cupboard and irrespective of the stage either of its installation or the fitting of any other item whatsoever in its vicinity. No other person, or firm or corporation is authorised by Condari to offer or give on its behalf any other greater warranty that given by Condari under this warranty.

Page 19: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 21

EXCLUSIONS There are some exclusions from the Condari Pty Ltd Guarantee. (on previous page) ATHERTON Rangehoods are designed to be used over all domestic barbecues available in AUSTRALIA. Outdoor barbecues will have a rating plate on them specifying that they are approved for outdoor use only. In practice any barbecue or outdoor cooking appliance over 50 mega joule will need a specially made rangehood with an air movement exceeding 2000 cubic meters per hour. If none of our Standard ATHERTON Rangehoods suit your requirements, Condari can manufacture a special rangehood to suit your Alfresco Area.

Page 20: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

22 Rangehood Installation Instructions

STANDARD WARRANTY

Date purchased Purchased from Model Serial No The purchaser must fill in the above information and keep this with the original purchase document. This form must be produced if and when a claim is made under this warranty. Rangehoods are made in Ringwood, Australia. Tel: +61 3 9482 7088 Fax: +61 3 9482 7011 Email: [email protected]

Please Note that the Standard Warranty is from the date of purchase. Proof of purchase date is required to obtain service under this warranty. If no proof of purchase date can be provided at the time of the service call, then the service call will be charged at the standard rate. If proof of purchase date can be provided at a later date, reimbersement of the service cost will be made.

Page 21: ATHERTON RANGEHOOD INSTALLATION INSTRUCTIONS › wp-content › uploads › 2020 › 03 › A-Ath… · ATHERTON Rangehoods are designed to be installed 1200 mm to 1400 mm above the

Rangehood Installation Instructions 23

EXTENDED WARRANTY

Condari Pty Ltd provides an extended warranty from 36 months to 72 months if installed by an authorised Condari installer and the below form is completed. The authorised installer also offers a warranty on their workmanship for the same period of 72 months with a guarantee that the installation is in compliance with ‘Atherton installation instructions’.

Customer Name: Model Number: Serial Number: Purchased from: Purchased Date: Installed Date: Installer Name: Installer Signature: Condari Pty Ltd authorised installer stamp: (This is required for validity of extended warranty)

Please note: The installation warranty does not cover the ageing process in a building or any problems due to storm damage.