Status of ILC Activity in KEK H. Hayano, KEK APPI 03/10/2005.
ATF Status December/2002 H. Hayano
description
Transcript of ATF Status December/2002 H. Hayano
ATF Status December/2002H. HayanoH. Hayano
Multibunch photo-cathode RF-gunMultibunch emittance
Instrumentation developmentsPlans for spring 2003 run
ISG9 at KEK 12/10/2002
ATF Introduction
E=1.28GeVNe=1x1010 e-/bunch 1 ~ 20 bunchesRep=1.5HzX emit=2.5E-6( at 0 intensity)
Y emit=2.5E-8( at 0 intensity)
Single Bunch emittance
x = 2.0x10-9 ( xn = 5.0x10-6)
y = 2.1x10-11(yn = 5.3x10-8) at 9x109 intensity
Multibunch photo-cathode RF gun
For better MB injection into DR generation of high quality multibunch
low emittance, low energy spread, high & flat intensity Combination of BNL-cavity and Cs2Te cathode enough operation experience in CTF & TTF New laser system; 20 bunch, 2.8ns spacing, 266nm Nd:YVO4 (1064nm) 357MHz mode-lock laser + amplifier Load-lock system for Cs2Te cathode block extra cathode blocks and evaporation chamber KEK built gun-cavity precise machining and blazing by KEK machine center
Multibunch photo-cathode RF-gun
IP 400 l/s
3m Acc. structureRF gun cavitySolenoid
transport movers
Multibunch photo-cathode RF gun assemblyJune ~ Oct. 2002
Multibunch Laser
IP 400 l/s
ION source for cleaning
Evaporation chamber
Cathode loading axisGV
GVGV GV
RF gun beam at 80MeV Beam Intensity ~1x1010/bunch Normalized Emittance y= 28x10-6 rad.m Bunch length z= 6.4 ~ 7.9 ps Energy spread dE/E = 4.9% full-width Q.E. of CsTe cathode 16% initial, 2~3% with RF ON
& constant over a week
Multibunch emittance Beam intensity in DR 0.3~ 0.5 x1010 e-, 19 bunch, 2.8ns spacing with 0.78Hz repetition limited by max. beam power of radiation safety Monitors of MB emittance MB (or projected) Laser-wire Projected SR interference monitor, X-ray SR monitor MB (or projected) wire scanner: (EXT-line coupling problem) Problem of MB emittance big energy fluctuation ( coupled bunch longitudinal oscillation )
X-ray SR profilesX profile Y profile
39.27 +/- 0.53 [μm] 7.30 +/- 0.12 [μm]
xXSR = 1.8 x10-9 , y
XSR = 1.1 x10-11 ( ~ 3 x109 bunch intensity)
After subtracting dispersion effect
Candidates of impedance source DR cavity HOM no response for temp., tuner, Vc, feedback, direct RF feedback, no enhanced signal from HOM pickup Kicker ceramic insulation temp. rise with beam, HFSS calculation suggestion Other source? tune exciter electrode?
New instrumentation developments ODR beam size monitor observation of Diffraction Radiation in visible light new slit target was installed. New clip-circuit for DR BPM single shot 3µm resolution circuit Beam tilt detection by cavity-BPM study was started (SLAC) nm resolution cavity-BPM 3 cavity BPM setup was started Multibunch BPM circuit test continuing (SLAC) circuit under fabrication (KEK)
end
Plans for Autumn-Spring 2003 run Run by multibunch photo-cathode RF gun smooth multibunch operation from 1 bunch to 20 bunches with high intensity and low beam loss MB emittance study emittance was confirmed by Laser Wire. Longitudinal oscillation was observed. need to fix them by identifying the source. DR re-alignment & Beam Based Alignment using new coming BPM circuit (Jan. 2003), more precise orbit control will be possible. EXT line coupling study search of coupling source (EXT kicker?) Instrumentation developments LW, XSR monitor, ODR monitor, cavity-BPM, multibunch BPM, etc