![Page 1: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/1.jpg)
Assessment of Water
Treatment Devices
Charles P. Gerba
Professor of Environmental Microbiology
University of Arizona
Tucson, Arizona
![Page 2: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/2.jpg)
Point-of-Use Laboratory has evaluated hundreds of
Water Treatment Devices
To assess New Technologies
for Water and Wastewater
Treatment
A Village where every
building is a Laboratory
designed to assess Water
Technology
![Page 3: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/3.jpg)
Point of Use & Microbiology Laboratory
![Page 4: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/4.jpg)
Microbiological Water Purifier
• A device or chemical that is capable of
making water free from waterborne
microorganisms
• “Drinking water should be treated to reduce
the risk of waterborne illness to less than
1:10,000 per year.“ (United States
Environmental Protections Agency)
![Page 5: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/5.jpg)
Types of Water borne/based Pathogens
Viruses Bacteria Parasites
![Page 6: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/6.jpg)
Sizes of Microorganisms
1nm
100 nm
10 nm
1µm
10 µm
100 µm
1mm
Viruses
Mycoplasma
Bacteria
Helminths
Protozoa
10-3
10-7
10-8
10-9
10-6
10-5
10-4
![Page 7: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/7.jpg)
Giardia cysts (8-12 µm) and
Cryptosporidium oocysts (4-6 µm)
Giardia cyst→
Cryptosporidium
oocyst
![Page 8: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/8.jpg)
(Cryptosporidium parvum) Most Chlorine Resistant
waterborne microbe known
![Page 9: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/9.jpg)
Campylobacter spp.
• Most common cause of bacterial diarrhea in animals and humans. C
• Excreted by wide birds and poultry
• Can be expected to occur in all types of surface waters
![Page 10: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/10.jpg)
Rotavirus – Major
cause of childhood diarrhea world wide (~70 nm)
![Page 11: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/11.jpg)
How do we ensure that water
has been adequately treated
?
![Page 12: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/12.jpg)
Testing Requirements Guide Standard and Protocol
For Microbiological Water
Purifiers
NSF Protocol P231
![Page 13: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/13.jpg)
Log10 reduction*
required: bacteria
Log10 reduction*
required: viruses
Log10 reduction*
required: protozoa
≥ 6 ≥ 4 ≥ 3
Required
test
organisms
Klebsiella
terrigena
Poliovirus
Type 1
Rotavirus SA-
11
Cryptosporidium
parvum
Guide Standard and Protocol for
Microbiological Water Purifiers
![Page 14: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/14.jpg)
Rating Log10 reduction*
required: bacteria
Log10 reduction*
required: viruses
Log10 reduction*
required: protozoa
Highly protective.
Achieves WHO-
recommended risk-
based target of 10-6
DALYs per
person/year.
≥ 4 ≥ 5 ≥ 4
Protective.
Achieves
intermediate risk-
based target of 10-4
DALYs per
person/year,
representing
improved water
quality.
≥ 2 ≥ 3 ≥ 2
Evaluating household water treatment
options: health-based targets and
performance specifications (WHO, 2011)
![Page 15: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/15.jpg)
bacteria viruses : protozoa
Campylobacter
jejuni Rotavirus Cryptosporidium
parvum
OR Escherichia
coli
MS-2
Coliphage Clostridium
perfringens spores
Suggested Test Organisms
![Page 16: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/16.jpg)
Must Work
under a variety
of Water Quality
Types
-Turbidity
(60 NTU)
-Temperature
(4 oC) (for
halogens)
-pH (for
halogens)
-High dissolved
solids
![Page 17: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/17.jpg)
Performance
• Must be tested and
perform throughout
the lifetime of the
device (ie.e if unit
is designed for
18,000 liters it must
be tested for 18,000
liters)
![Page 18: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/18.jpg)
We have been
testing the Family
Lifestraw ®Unit for
more than three
years under a
variety of water
quality conditions
![Page 19: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/19.jpg)
Laboratory Test Stand
![Page 20: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/20.jpg)
![Page 21: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/21.jpg)
Greater Than
• If all the test organisms are
removed below the detection
limit the % or Log removal is
reported as greater than or
• >
![Page 22: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/22.jpg)
Summary of Reduction Values for Test Organisms
Organism MS2 Virus (23 nm)
E. coli (0.5 micron)
Cryptosporidium
parvum
(4-6 microns)
Liters of Water
of Water
Processed
18,000 18,000 18,000
Log Reduction
>6.8
>7.6
>4.0
Mean retention
efficiency (%)
> 99.9999
> 99.99999
> 99.99
![Page 23: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/23.jpg)
Summary of Reduction Values for Test Organisms
Accelerated Aging
Organism MS2 Virus (23 nm)
E. coli (0.5 micron)
Cryptosporidium
parvum
(4-6 microns)
Volume of
Water
Processed
900L
300 NTU
900L
300 NTU
900L
300 NTU
Log Reduction
>5.4
>6.65
>4.1
![Page 24: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/24.jpg)
Change in Flow Rate over 20,000 liters of Operation
![Page 25: Assessment of Water Treatment Devices - ansam.com.mx OF WATER TREATMENT.pdf · Assessment of Water Treatment Devices Charles P. Gerba Professor of Environmental Microbiology ... Microbiological](https://reader030.fdocuments.net/reader030/viewer/2022040914/5e8bccb70dd72141917dfdd1/html5/thumbnails/25.jpg)
Microbiological
Water Purifier