ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center...

31
ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 1 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 SECTION 08-7100 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. The conditions of the Contract and Division 1 – General Requirements, apply to the Work Specified in this section. B. Section Includes: 1. Furnish and install commercial door hardware for the following: a. Standard steel doors. b. Wood doors. c. Other doors to the extent indicated. 2. Cylinders for doors specified in other Sections. C. Related Sections: 1. Section 06-2000: Finish Carpentry. 2. Section 08-1113: Hollow Metal Doors and Frames. 3. Section 08-4229: Automatic Entrances. Automatic Entrances supplier shall provide all hardware except cylinders. 4. Section 08-1416: Flush Wood Doors. 1.2 REFERENCES A. NFPA 80: Standard for Fire Doors and Fire Windows- 2007 Edition. B. NFPA 99: Health Care Facilities- 2002 Edition. C. NFPA 105: Recommended Practice for the Installation of Smoke-Control Door Assemblies- 2003 Edition. D. NFPA 252: Standard Methods of Fire Tests of Door Assemblies- 1999 Edition. E. BHMA Directory of Certified Products: Builders Hardware Manufacturers Association. F. ANSI/BHMA A156: BHMA Standards G. Door and Hardware Institute (DHI) Publication “Installation Guide for Doors and Hardware”- 1994 Edition. H. DHI Publication “Sequence and Format for the Hardware Schedule” I. ANSI A117.1- Accessible and Usable Buildings and Facilities- 1998 Edition. J. Electrified Door Hardware: Listed and Labeled as defined in NFPA 70, Article 100, by testing agency acceptable to authorities having jurisdiction. K. Applicable State and Local Building Codes. 1.3 SUBMITTALS A. Comply with Section 01-3300, unless otherwise indicated. 1. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the “Design Intent” of the system/assembly is understood and can be reviewed together. a. Section 08-1113– Hollow Metal Doors and Frames. b. Section 08-1416 – Flush Wood Doors.

Transcript of ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center...

Page 1: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 1 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

SECTION 08-7100 DOOR HARDWARE

PART 1 - GENERAL

1.1 SUMMARY

A. The conditions of the Contract and Division 1 – General Requirements, apply to the Work Specified in this section.

B. Section Includes: 1. Furnish and install commercial door hardware for the following:

a. Standard steel doors. b. Wood doors. c. Other doors to the extent indicated.

2. Cylinders for doors specified in other Sections.

C. Related Sections: 1. Section 06-2000: Finish Carpentry. 2. Section 08-1113: Hollow Metal Doors and Frames. 3. Section 08-4229: Automatic Entrances. Automatic Entrances supplier shall provide all

hardware except cylinders. 4. Section 08-1416: Flush Wood Doors.

1.2 REFERENCES

A. NFPA 80: Standard for Fire Doors and Fire Windows- 2007 Edition.

B. NFPA 99: Health Care Facilities- 2002 Edition.

C. NFPA 105: Recommended Practice for the Installation of Smoke-Control Door Assemblies- 2003 Edition.

D. NFPA 252: Standard Methods of Fire Tests of Door Assemblies- 1999 Edition.

E. BHMA Directory of Certified Products: Builders Hardware Manufacturers Association.

F. ANSI/BHMA A156: BHMA Standards

G. Door and Hardware Institute (DHI) Publication “Installation Guide for Doors and Hardware”- 1994 Edition.

H. DHI Publication “Sequence and Format for the Hardware Schedule”

I. ANSI A117.1- Accessible and Usable Buildings and Facilities- 1998 Edition.

J. Electrified Door Hardware: Listed and Labeled as defined in NFPA 70, Article 100, by testing agency acceptable to authorities having jurisdiction.

K. Applicable State and Local Building Codes.

1.3 SUBMITTALS

A. Comply with Section 01-3300, unless otherwise indicated. 1. Special Submittal Requirements: Combine submittals of this Section with Sections listed

below to ensure the “Design Intent” of the system/assembly is understood and can be reviewed together. a. Section 08-1113– Hollow Metal Doors and Frames. b. Section 08-1416 – Flush Wood Doors.

Page 2: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 2 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

B. Hardware Schedule: Submit a detailed, vertical type hardware schedule conforming to DHI publication, “Sequence and Format of the Hardware Schedule”. Prepare schedule under the direct supervision of an Architectural Hardware Consultant (AHC). Hardware schedules submitted without the AHC’s signature will be rejected without review. 1. List and describe each opening separately; include all doors with identical hardware, except

hand, in a single heading. Include door number, room designations, degree of swing, and hand.

2. List all hardware items; include manufacturer’s name, quantity, product name, catalog number, size, base metal, finish, fasteners and related details where applicable.

3. List related details; include dimensions, door and frame material and other conditions affecting hardware.

C. Templates: Submit current manufacturer’s templates for hardware scheduled, along with “Approved Hardware Schedule” to door and frame supplier and others as applicable. 1. Templates, wiring schematics, and “Approved Hardware Schedule” of electrical items to

electrical for coordination and verification of voltages and locations.

D. Keying Schedule: Submit detailed keying Schedule, indicating Owner’s instructions from pre-submittal hardware and keying meeting with hardware supplier. 1. Submit 1 copy to architect for information only.

E. Contract Close-out Submittals: Comply with Section 01-7700 including specific requirements. 1. Operating and maintenance manuals: Submit 3 sets containing the following: 2. Maintenance instructions and warranty information for each item of hardware. 3. Catalog pages for each product. 4. Contact information for supplier of hardware and local representatives of each product

manufacturer. 5. Parts list for each product. 6. Copy of final hardware schedule. 7. Copy of final keying schedule.

1.4 QUALITY ASSURANCE

A. Where items of hardware are not definitely or correctly specified and is required for the intended service, such omission, error or other discrepancy should be directed to the Architect prior to the bid date for clarification by addendum. Otherwise, furnish such items in the type, quality and quantity established by this specification for the appropriate service intended.

B. Source Limitations: a. Obtain each type and variety of aluminum, steel and wood door hardware from the

same manufacturer, unless otherwise indicated.

C. Supplier Qualifications: 1. Commercial hardware supplier who maintains and operates an office and stocking warehouse

in the project area for at least two years and can document experience with projects of similar type and scale.

2. Supplier to employ Architectural Hardware Consultant (AHC) as recognized by DHI for the purpose of overseeing the scheduling, coordinating hardware, establishing keying schedule, and be available during the course of construction to consult with Contractor, Architect, and OSR about the mechanical and electrical door hardware specified. Persons not in the direct employ of the supplier shall not be considered as meeting this requirement.

3. Hardware Schedule shall be prepared under the direct supervision of and signed by an AHC.

Page 3: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

D. Installer’s Qualifications: Firm with 3 years experience in installation of similar hardware to that required for this Project. 1. Successfully completed not less than 5 comparable scale projects.

E. Pre-Submittal Hardware and Keying Meeting: Prior to preparing final submittals, coordinate and hold a meeting including the Owner, Architect, and supplier of hardware to determine the following: 1. Lock Function: Demonstrate the function/type of each lockset scheduled and verify function at

each door. 2. Electrical Operation: Verify function of all openings requiring electrified hardware. 3. Keying: Determine the keying requirements for preparation of a final keying schedule. 4. Submit a letter of compliance, indicating when this meeting was held and who was in

attendance, to the Architect, Owner and supplier.

F. Pre-Installation Conference: Prior to the installation of hardware, coordinate a job site pre-installation meeting. Include at meeting the supplier, manufacturers representatives for continuous hinges, locks, closers, overhead stops and exit devices. General Contractors selected installers for the entire project shall be in attendance. Training shall include use of installation instructions, hardware schedules, templates and physical product samples. 1. Submit a letter of compliance, indicating when this meeting was held and who was in

attendance, to the Architect, Owner and supplier.

G. Post-Installation Walk Through: After installation of hardware, coordinate with hardware supplier and Manufacturers representative of continuous hinges, locks, closers and exit devices. Inspect hardware for proper installation and function. Document compliance. Hardware supplier and Manufacturers representative shall then meet with owner to explain functions, use and maintenance of all types of hardware installed.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Packing and Shipping: 1. Deliver products in original unopened packaging with legible manufacturer’s identification. 2. Package hardware to prevent damage during transit and storage. 3. Mark hardware to correspond with approved Hardware Schedule. 4. Deliver permanent cores and keys (prepared according to the accepted keying schedule) to

Owner by registered mail or overnight package service prior to occupancy. 5. Compare delivered hardware to Approved Hardware Schedule. Report any shortages or

damaged materials to Architect and Supplier within 24 hours of delivery. Shortages not reported will be the Contractor’s responsibility.

6. Store hardware in a secured and dry environment to protect against loss, theft and damage.

1.6 COORDINATION

A. Templates: Distribute door hardware templates for doors, frames, and other Work specified to be factory prepared for installing door hardware. Check Shop Drawings of other Work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

Page 4: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 4 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

1.7 WARRANTY

A. General Warranty: Comply with Division 1 requirements.

B. Manufacturer Warranty: Manufacturer’s publicly published warranty must be greater than or equal to: 1. Mechanical Grade One Locksets: 5 Years 2. Architectural Grade Panic Exit Hardware: 5 Years 3. Panic Exit Hardware Trim: 5 Years 4. Mechanical Door Closer Body: 10 Years

C. Provide written verification of manufacturer’s standard published warranty.

1.8 MAINTENANCE SERVICE

A. Maintenance Tools and Instructions: Furnish complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

B. Maintenance Service: Beginning at Substantial Completion, provide 12 months' full maintenance by skilled employees of door hardware installer. Include quarterly preventive maintenance, repair or replacement of worn or defective components, lubrication, cleaning, and adjusting as required for proper door hardware operation. Provide parts and supplies same as those used in manufacture and installation of original products.

1.9 EXTRA MATERIALS

A. Furnish full-size units of door hardware described below, before installation begins, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

B. Door Hardware: 1. 1 Case Closers Bodies 2. 2 Locksets (Each Function) 3. 2 Hospital Latches (Each Function) 4. Provide and keep held secure, 20 additional uncombinated cores and 50 each extra key

blanks for each system dedicated solely for this facility. Releasing of this material shall ONLY be authorized by the owner accompanied with letter of authorization and registration certificate.

PART 2 - PRODUCTS

2.1 SCREWS AND FASTENERS

A. Fasteners: 1. Screws: Phillips flat-head; machine screws (drilled and tapped holes) for metal doors, wood

screws for wood doors. Finish screw heads to match hardware surface. 2. Threaded-to-the-Head Wood Screws: For fire-rated wood doors.

Page 5: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 5 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

2.2 BUTT HINGES

A. Butts and Hinges: BHMA A156.1. Listed under Category A in BHMA's "Certified Product Directory." 1. Hinge Sizes: Provide the following hinges in widths sufficient to minimally clear trim. Thickness Size 1-3/4 inch Doors 4-1/2 inch by 4-1/2 inch 2. Quantity:

a. 1 pair per leaf for openings through 60 inches high. b. 1 additional hinge per leaf for each additional 30 inches in height or fractions thereof. c. 1 additional hinge for doors 3’-4” wide to 4’-0” wide. d. 1 additional hinge for exterior and vestibule doors.

3. Applications: a. Exterior out swinging doors: Type 5 x NRP. b. Exterior in swinging doors and vestibule doors: Type 4. c. Interior doors with closers: Type 2 or 4. d. Interior doors over 36 inches in width: Type 4. e. Interior doors 36 inches or less without closer: Type 2. f. Exterior and reversed beveled interior lockable doors: Non-removable loose pin (NRP)

hinges. g. Tips: Hospital Tips unless otherwise indicated in hardware groups.

4. Acceptable Manufacturers and Products: Type ANSI Bommer Hager McKinney Type 1 (0.134) A8133 5000 1279 T2714 Type 2 (0.134) A8112 BB5000 BB1279 TA2714 Type 3 (0.134) A5112 BB5002 BB1191 TA2314 Type 4 (0.180) A8111 BB5004 BB1168 T4A3786 Type 5 (0.180) A5111 BB5006 BB1199 T4A3386

2.3 CONTINUOUS PIN AND BARREL HINGES

A. Hinge material: 14 gauge stainless steel.

B. Pin: Stainless steel, 0.25 inch diameter.

C. Tip: Hospital Tip unless otherwise indicated in hardware groups.

D. Construction: Full height pin and barrel, providing full height door support, 600 pounds capacity. Non-handed, edge mount unless otherwise specified. 0.438 inch outside barrel diameter.

E. Fastener holes: Factory drilled, symmetrical template pattern. Minimum 21 for door, 21 for frame, for opening 7 feet tall.

F. Knuckles: 2 inches long, including split nylon bearing at each separation; quiet, smooth, self-lubricating operation.

G. Rating: Warnock Hersey or UL for fire rated openings. 1. Note: Fire label for doors and frames should be placed on the header and top rail of fire rated

doors and frames.

H. Modifications: 1. Medical Bearing: “MB” Specially designed for use in hospitals and high frequency openings.

I. Adjusting screws: Adjustable to correct frame irregularities up to 3/8 inch. Markar "Adjusta-Screw”.

Page 6: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 6 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

J. Acceptable Manufacturers and Products: Markar McKinney Select SS Edge-Guard HG-305 MCK-HG305 SL305SS Swing Clear HG-326 MCK-HG326 ---

2.4 LOCKSETS / LATCHSETS

A. Provide wrought boxes and curved lip strikes with lip length sufficient to minimally clear trim.

B. Heavy Duty Commercial Cylindrical Type: 1. Comply with ANSI/BHMA A156.2 requirements for Series 4000 Grade 1. 2. Provide functions as specified in hardware sets. 3. Provide locks that comply with ICC/ANSI A117.1 accessibility standards. 4. Provide locks with free-wheeling levers in all locking functions. 5. Latch bolts on locking functions: 2-3/4 inch backset with deadlocking feature. 6. Acceptable Manufacturers and Products: (Free-Wheeling)

Corbin-Russwin Sargent Yale Lock CL3300 FW-10-Line 5400LNTrim PZD LP PB

C. Heavy Duty Mortise Type: 1. Comply with ANSI/BHMA A156.13 requirements Series 1000 Operational Grade 1 mortise

locks. 2. Provide locks and latch sets in the function as specified in function as specified in hardware

sets. 3. Comply with ICC/ANSI A117.1 accessibility requirements. 4. Provide locks with reversible handing of lock without disassembly of lock. 5. Acceptable Manufacturers and Products:

Corbin-Russwin Sargent Yale Lock ML2000 8200 8800FL Trim-Sect. PSA LNP PBR

D. Hospital Latchsets: 1. Provide Push/Pull latch with 5 inch backset and engraved (Push – Pull). 2. Acceptable Manufacturers and Products

Corbin Russwin Sargent TrimcoCylindrical HL 10 Series 115 1580 Mortise -- 7800PT 1562M

2.5 STAND ALONE ACCESS CONTROL LOCKS

A. Provide security-locking system that is stand alone battery operated ANSI/BHMA Grade One locks. All locks shall have an interchangeable core cylinder bypass. All levers shall match mechanical locks and trim. All readers shall be equipped with non-volatile memory. Provide locks capable of minimum of 100 user capacity.

B. Acceptable Manufacturers: Corbin-Russwin Sargent Yale Cylindrical CL33834 x M800 KP10G77 E5496LN

Page 7: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 7 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

2.6 EXIT DEVICES

A. Comply with ANSI/BHMA A156.3 requirements for Grade 1.

B. Provide exit devices in functions as specified in hardware groups.

C. Provide exit devices by single manufacturer.

D. Provide vandal resistant outside trim to discourage abuse when door is locked. Provide trim with lever design to match locks.

E. Provide cylinder dogging on non-rated devices.

F. Architectural Grade: 1. Acceptable Manufacturers and Products:

Corbin-Russwin Sargent Yale Wide Stile ED5000 80 Series 7000 Series Active Trim 900 Series ET 600 Series

2.7 CYLINDERS AND KEYING

A. Coordinate and hold a keying meeting to determine keying requirements. Meeting shall include the Hardware Supplier, Owner and Owner’s representative. 1. Provide a keying schedule with keying designations conforming to Door and Hardware

Institute document “Keying Systems and Nomenclature” prior to ordering permanent cores. 2. Provide a letter to Architect and Owner stating compliance.

B. Provide all locks and cylinders with 6 pin interchangeable core cylinders.

C. Provide temporary keyed construction cores and keys for all doors during the construction period. Construction control and operating keys and cores shall not be part of the Owner’s permanent keying system or furnished on the same keyway (or key section) as the Owner’s permanent keying system.

D. Establish new, factory- generated master key system. Provide Utility-patented cylinders factory keyed as directed by Owner. Owner will supply system expansion requirements. 1. Acceptable Manufacturers and Products:

Corbin-Russwin Sargent Yale Patented Security Pyramid Signature 5000

E. Permanent keys, cores, master keys, change keys and additional key blanks, permanent control keys and bitting list indicating all bitting generated for this project shall be sent direct to Owner, via registered mail. Shipment shall be complete, keys shall be enveloped in sets, tagged with key set numbers (with proper code numbers and factory file or folio number). Permanent keys and cores shall not be packed with locks. Should any permanent keys and/or cores be sent anywhere other than previously stated, they shall be required to be replace at no additional cost to the owner.

F. Keys: Provide factory-cut keys that are nickel silver and furnished with a large bow. Provide industry standard visual key control stamping for each permanent cut key. Furnish keys in the following quantities.

a. 3 each Change Keys per cylinder. b. 2 each Control Keys. c. 6 each Master Keys per master key group. d. 2 each Construction Control keys. e. 15 each Construction keys.

Page 8: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 8 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

G. Visual Key Control: 1. Stamped “Duplication Prohibited” 2. Stamp with key symbol – Keys only 3. Stamp with key symbol –Concealed on cylinders (

2.8 KEY CONTROL CABINET

A. Key Control Cabinet: Furnish BHMA A156.5, Grade 1; metal cabinet with baked-enamel finish; containing key-holding hooks, labels, 2 sets of key tags with self-locking key holders, key-gathering envelopes, and temporary and permanent markers; with key capacity of 150 percent of number of locks. 1. Wall-Mounted Cabinet: Cabinet with hinged-panel door equipped with key-holding panels and

pin-tumbler cylinder door lock. 2. Acceptable Manufacturers and Products:

a. Telkee, a Tri Palm International Company: RWC/AWC Series. b. Key Control Systems, Inc. (KCS): c. Lund Equipment Co., Inc. (LUN): 1200 Series. d. MMF Industries (MMF): 201-8000-03 Series.

2.9 KEY MANAGEMENT SOFTWARE

A. Provide key management software capable of running in Windows 98, 2000, ME, Nt or XP.

B. Software shall provide tracking, issuing, and collecting and transferring information regarding keys, doors, and hardware.

C. Provide complete bitting list on computer disc for Owner’s use.

D. Provide $500 allowance for training of Owner’s personnel on the proper operation and application of the key management software.

2.10 OPERATING TRIM

A. Push Plates: .050 in thickness. Beveled edges (B4E). 1. Size: 8 inch by 16 inch. Provide 4 inch by 16 inch where 8 inch by 16 inch is not applicable

due to door conditions. 2. Acceptable Manufacturers and Products:

Burns McKinney Trimco 4 inch x 16 inch 54 P053 1001-3

B. Door Pulls: 1-1/4 inch round material, 18 inch screw centers. 1. Provide spanner turning washer similar to McKinney type “M” with appropriate riv-nut or

threaded bushing for free ends. Provide reinforcement for hollow metal doors. 2. Acceptable Manufacturers and Products:

Burns McKinney Trimco 1 ¼”, 18” CTC OS M39G OP9017 1191-5J

2.11 DOOR CLOSERS

A. Fully adjustable type with complete spring power adjustment, sizes 1 through 6; field adjustable per door size and frequency of use. ANSI/BHMA A156.4 requirements for Grade 1 and shall be

B. Provide closers with sweep, latch, and back check features.

C. Provide parallel rigid arm for closers mounted on push side of opening.

Page 9: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 9 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

D. Coordinate with door supplier to provide proper blocking for surface mounting. Use of through-bolts is not acceptable.

E. Provide units that are compliant to physically handicapped, provide units complying with ANSI/ICC A117.1 provisions for door opening force and delayed action closing.

F. Install closers using only manufacturer-furnished template machine screws for metal doors and manufacturer -furnished wood screws for wood doors. 1. Use of self-drilling or self-tapping fasteners is not allowed.

G. Accessories: Mounting brackets, drop plates, special shoes required by door and frames conditions.

H. Acceptable Manufacturers and Products: Corbin-Russwin Norton Sargent Yale DC6000 7500 351 4400

2.12 LOW ENERGY OPERATORS

A. Low Energy Operator and all necessary equipment to properly operate door to be provided by Section 08-7113.

2.13 STOPS AND HOLDERS

A. Overhead Stops: 1. Provide overhead stop for doors that are capable of swinging more than 145 degrees before

striking wall and where door strikes fixed object such as sink, cabinet, and similar obstructions.

2. Install surface-mounted stops/holders using only manufacturer supplied template machine screws for metal doors and manufacturer supplied wood screws for wood doors.

3. Acceptable Manufacturers and Products: Rixson SargentHeavy Duty Surface 9-Series 590

2.14 PROTECTION PLATES

A. Kick Plates: 0.050, beveled edges (B4E) and countersunk screw attachment. 1. Widths: 2 inches less than door width. 2. Height: 12 inches or 1/2 inch less than height of bottom rail, whichever is less. 3. Acceptable Manufacturers:

a. Burns b. McKinney. c. Trimco

B. Armor Plates: 0.050, beveled edges (B4E) and countersunk screw attachment. 1. Widths: 2 inches less than door width. 2. Height: 42 inches, and complying with door conditions. 3. Where indicated for fire-rated doors, protection plates shall be installed in accordance with the

listing of the door. Field-installed protection plates shall be labeled and installed in accordance with their listing.

4. Provide cut outs as required for attachment of other hardware specified. 5. Acceptable Manufacturers:

a. Burns b. McKinney. c. Trimco

C. Door Edge Guards: Stainless steel, 42 inches high, 18 gage unless otherwise specified in hardware groups. Notch for hinges and latchbolts and countersunk screw attachment.

Page 10: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 10 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

1. Surface-applied. Delete if on hollow metal doors. 2. Acceptable Manufacturers:

a. Burns b. McKinney. c. Trimco

D. Trim Protectors: 3/8” x 1-1/2” solid stainless steel bar with 3-1/4” projection and 14” CTC. 1. Acceptable Manufacturers:

McKinney TrimcoTPB05 1633

E. Lock Guards: 1. Provide as applicable where specified in hardware sets. 2. Acceptable Manufacturers:

a. McKinney. b. Rockwood c. Trimco

2.15 STOPS AND HOLDERS

A. Wall Stops: Provide wall stops as required for surrounding conditions for interior doors scheduled for “Wall Stop”, unless other stops are specified. 1. Acceptable Manufacturers and Products:

Burns McKinney Trimco Convex 570 WS01 1270WXConcave 575 WS02 1270WVExtended 530 DS20 1208 Wall Holder 533 ADH01 1254 Holder/Stop 631 DS22 1207

2.16 THRESHOLDS, WEATHERSTRIPPING, AND GASKETING

A. Thresholds: Provide full-saddle type threshold unless floor conditions dictate or detailed otherwise. 1. Provide flat saddles at fire rated doors where combustible material is indicated on both sides. 2. Acceptable Manufacturers and Products:

McKinney Pemko Reese 5 inch X 1/4 inch MCK271 271 S405 (x)

B. Sweeps: 1. Acceptable Manufacturers and Products:

McKinney Pemko ReeseNeoprene MCK315(x)N 315(x)N 323(x)

C. Weatherstrip: 1. Acceptable Manufacturers and Products:

McKinney National Guard Pemko Reese Solid Bar MCK2891PK 770U 2891PK 755

2. Where solid bar weatherstrip is used, install weather strip prior to other surface hardware such as door closers, exit devices etc. Supplier to ensure proper templating of surface hardware allowing for the thickness of the weatherstrip.

Page 11: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 11 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

D. Rain Drips: 1. Acceptable Manufacturers and Products:

McKinney Pemko Reese MCK346(x) 346(x) R201(x)

E. Automatic Door Bottoms: Units shall be provided with a light-spring action which reduces the operating force to 3-5 pounds required for actuation. 1. Acceptable Manufacturers and Products:

McKinney Pemko ReeseMCK4131RL 4131RL 521

F. Head and Jamb Casketing: 1. Coordinate with door manufacturer. Comply with UL10C for intumescent fire and smoke

material. 2. Provide smoke gasket at each labeled opening similar to McKinney MCKS88 3. Weatherstrip and sweeps for aluminum doors and frames specified in Section 08120.

2.17 ONE-WAY VIEWERS

A. Acceptable products of the following manufacturers:

McKinney Rockwood Trimco

DV3 622 976U

2.18 CLOTHES HOOKS

A. Acceptable products of the following manufacturers: Don-Jo Rockwood 302 796

2.19 FABRICATION

A. Base Metals: Produce door hardware units of base metal, fabricated by forming method indicated, using manufacturer's standard metal alloy, composition, temper, and hardness. Furnish metals of quality equal to or greater than that of specified door hardware units and BHMA A156.18. Do not furnish manufacturer's standard materials or forming methods if different from specified standard.

B. Fasteners: Provide screws per commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated. 1. Comply with NFPA 80 for fasteners of door hardware in fire-rated applications.

FINISHES

C. Standard: BHMA A156.18, as indicated in door hardware sets.

D. Protect mechanical finishes on exposed surfaces from damage by applying strippable, temporary protective covering before shipping.

E. Exposed Metal Finishes: BHMA 626 / US26D = Satin Chromium plated over nickel, over brass or bronze base metal.

BHMA 652 / US26D = Satin Chromium plated over nickel, over Steel base metal. BHMA 630 / US32D = Satin Stainless Steel, over stainless-steel base material.

Hinges-Exterior: 630 / US32D Hinges-Interior: 652 / US26D

Page 12: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 12 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

Continuous Hinges 630 / US32D Locksets: 626 / US26D Closers: 689 / AL Aluminum painted over any base material. Exit Devices: 630 / US32D Pushes, Pulls, Kick Plates: 630 / US32D Armor Plates: 630 / US32D Door Edge Guards: 630 / US32D Overhead Stops & Holders: 630 / US32D Door Stops: 630 / US32D Thresholds: AL – Mill finish aluminum Weatherstrip: AL – Mill finish aluminum Sweep Strips: AL – Mill finish aluminum Automatic Door Bottoms AL – Mill finish aluminum (Concealed) Automatic Door Bottoms SN – Satin nickel anodized aluminum (Semi-Mortised) Rain Drips: AL – Mill finish aluminum Miscellaneous Items: US26D

F. Provide locksets/latchsets, push/pull latches, exit devices, push plates, pulls, push/pull plates, pushbar, armor plates and edge guards in BHMA 630 / US32D = Satin Stainless Steel, over stainless-steel base material with an imperceptible antimicrobial coating which stems the spread of bacteria and other microbes by attacking the cell walls, interrupting metabolism and preventing reproduction.

G. Hardware on aluminum doors to match finish of doors and frames.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine doors and frames, with installer present, for compliance with requirements for installation tolerances, labeled fire door assembly construction, wall and floor construction, and other conditions affecting performance.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

A. Steel Doors and Frames: Comply with DHI A115 Series. 1. Surface-Applied Door Hardware: Drill and tap doors and frames per ANSI A250.6.

B. Wood Doors: Comply with DHI A115-W Series.

3.3 INSTALLATION

A. Mounting Heights: Mount door hardware units at heights indicated as follows unless otherwise indicated or required to comply with governing regulations. 1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural

Hardware for Standard Steel Doors and Frames." 2. Wood Doors: DHI WDHS.3, "Recommended Locations for Architectural Hardware for Wood

Flush Doors."

B. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work specified in Division 9 Sections. Do not install surface-mounted items until finishes have been completed on substrates involved.

Page 13: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 13 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

1. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation.

2. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.

C. Key Control System: Tag keys and place them on markers and hooks in key control system cabinet, as determined by final keying schedule.

D. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying with requirements specified in Section 07920 - Joint Sealants.

3.4 FIELD QUALITY CONTROL

A. Independent Architectural Hardware Consultant: Owner will engage qualified independent Architectural Hardware Consultant to perform inspections and to prepare inspection reports. 1. Independent Architectural Hardware Consultant will inspect door hardware and state in each

report whether installed Work complies with or deviates from requirements, including whether door hardware is properly installed and adjusted.

3.5 ADJUSTING

A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements. 1. Door Closers: Unless otherwise required by authorities having jurisdiction, adjust sweep

period so that, from an open position of 70 degrees, door will take at least 3 seconds to move to a point 3 inches from latch, measured to leading edge of door.

B. Occupancy Adjustment: Approximately 6 months after date of Substantial Completion, schedule installer's architectural hardware consultant to examine and readjust, including adjusting operating forces, each item of door hardware as necessary to ensure function of doors, door hardware, and electrified door hardware.

3.6 CLEANING AND PROTECTION

A. Clean adjacent surfaces soiled by door hardware installation.

B. Clean operating items as necessary to restore proper function and finish.

C. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion.

3.7 DEMONSTRATION

A. Engage factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes. Refer to Section 01820 - Demonstration and Training.

3.8 HARDWARE GROUPS

A. Furnish hardware items in quantities indicated unless additional hardware is required for complete and operable facility. Ensure completeness, proper function, and proper application of hardware for each door.

B. Refer to door schedule for hardware sets required at each door opening. Ignore hardware sets not used on door schedule.

Page 14: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 14 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

C. Furnish hardware items in quantities indicated unless additional hardware is required for complete and operable facility. Ensure completeness, proper function, and proper application of hardware for each door.

D. Refer to door schedule for hardware sets required at each door opening. Ignore hardware sets not used on door schedule.

HARDWARE SETS

GROUP-3.0 Locked - Classroom Function

3 Hinges TA2714 4.5” x 4.5” HT 26D MC 1 Lockset 10-63-64-SG 10G37 LP 26D SA 1 Stop WS01 32D MC

Functions: • Door normally closed and latched. • Outside lever active unless locked by key in outside cylinder. • Rotating inside lever always allows free egress.

GROUP-4.0 Locked - Storeroom Function

3 Hinges TA2714 4.5” x 4.5” HT 26D MC 1 Lockset 10-63-64-SG 10G04 LP 26D SA 1 Stop WS01 32D MC Functions:

• Door normally closed latched and secured. • Outside lever always locked. Rotating key in outside cylinder retracts latchbolt. • Rotating inside lever always allows free egress.

GROUP-11.3 Exit Latch - Closer

3 Hinges TA2714 4.5” x 4.5” HT 26D MC 1 Latchset SG-10U15-3 LP 26D SA 1 Closer PR7500 689 NO 1 Kick Plate KP50 12” x 2” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 2” L.D.W. HB4E CSK 32D MC 1 Stop WS01 32D MC 1 Gasket MCKS88 BLK MC Functions:

• Door normally closed and latched. • Inside lever allows free egress. No outside trim.

GROUP-13.0 Locked - Closer - Classroom Function

3 Hinges TA2714 4.5” x 4.5” HT 26D MC 1 Lockset 10-63-64-SG 10G37 LP 26D SA 1 Closer 7500 689 NO 1 Kick Plate KP50 12” x 2” L.D.W. HB4E CSK 32D MC 1 Stop WS01 32D MC 1 Gasket MCKS88 BLK MC Functions:

• Door normally closed and latched. • Outside lever active unless locked by key in outside cylinder. • Rotating inside lever always allows free egress.

Page 15: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 15 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

GROUP-16.2 Push/Pull - Closer 4 Hinges TA2714 5” x 4.5” HT 26D MC 1 Push Plate P053 4’ x 16” 32D MC 1 Offset Pull OP9017 M-MTG x B3 32D MC 1 Closer 7500 689 NO 1 Kick Plate KP50 12” x 2” L.D.W. HB4E CSK 32D MC 1 Stop WS01 32D MC 1 Gasket MCKS88 BLK MC 1 Auto Door Bottom MCK4131SNRL(Semi Mortised) SN MC Functions:

• Door normally closed. • Pushing or pulling on door allows free passage.

GROUP-21.0 Hardware by others, except the following: Miscellaneous interior hardware, furnished by door manufacturer or specified elsewhere, except as follows:

1 Cylinders 10-63-64 40 Series As Required for Aluminum Sliding Doors.

GROUP-31.0 Push/Pull Latch

3 Hinges TA2314 5” x 4.5” HT 32D MC 1 Hospital Latch SG-28 115P-TB 26D SA 1 Closer 7500 689 NO 1 Armor Plate KP50 38” x 2” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 2” L.D.W. HB4E CSK 32D MC 1 Wall Stop DS20 26D MC 1 Gasket MCKS88 BLK MC 1 Auto Door Bottom MCK4131SNRL(Semi Mortised) SN MC Functions:

• Door normally closed and latched. • Both paddles always active allowing free passage.

GROUP-31.2 Push/Pull Latch

4 Hinges TA2314 5” x 4.5” HT 32D MC 1 Hospital Latch SG-28 115P-TB 26D SA 1 Closer 7500 689 NO 1 Armor Plate KP50 38” x 2” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 2” L.D.W. HB4E CSK 32D MC 1 Wall Stop DS20 26D MC 1 Gasket MCKS88 BLK MC 1 Auto Door Bottom MCK4131SNRL(Semi Mortised) SN MC Functions:

• Door normally closed and latched. • Both paddles always active allowing free passage.

GROUP-31.3 Push/Pull Latch

1 Continuous Hinge HG-326 HT MB x Adjust-A-Screw 32D MA 1 Hospital Latch SG-28 115P-TB 26D SA 1 Armor Plate KP50 38” x 1” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 1” L.D.W. HB4E CSK 32D MC 1 Edge Guard EG11 32D MC 1 Trim Protection Bar TPB05 32D MC 1 Wall Stop DS20 26D MC 1 Gasket MCKS88 BLK MC Functions:

• Door normally closed and latched. • Both paddles always active allowing free passage.

Page 16: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 16 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

GROUP-33.2 Hospital Latch - Classroom Function

1 Continuous Hinge HG-326 HT MB x Adjust-A-Screw 32D MA 1 Hospital Lockset 10-63-64-SG 7837PT 32D SA Note: Push-Down / Pull-UP 1 Closer 7500 689 NO 1 Armor Plate KP50 38” x 1” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 1” L.D.W. HB4E CSK 32D MC 1 Edge Guard EG11 32D MC 1 Trim Protection Bar TPB05 32D MC 1 Wall Holder ADH01 26D MC 1 Gasket MCKS88 BLK MC 1 Auto Door Bottom MCK4131SNRL(Semi Mortised) SN MC Functions:

• Inside always by paddle. • Outside by paddle, except when outside paddle is set by outside key, then, outside by key.

GROUP-40.0 Locked - Closer - Storeroom Function

3 Hinges TA2714 4.5” x 4.5” HT 26D MC 1 Lockset 10-63-64-SG 10G04 LP 26D SA 1 Closer PR7500 689 NO 1 Kick Plate KP50 12” x 2” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 2” L.D.W. HB4E CSK 32D MC 1 Stop WS01 32D MC 1 Gasket MCKS88 BLK MC Functions:

• Door normally closed, latched and secured. • Outside lever always rigid • Key outside retracts latchbolt. Key can only be removed in locked position. • Latchbolt retracted by lever from inside at all times.

GROUP-40.2 Locked - Closer - Storeroom Function

3 Hinges TA2714 5” x 4.5” HT 26D MC 1 Lockset 10-63-64-SG 10G04 LP 26D SA 1 Closer 7500 689 NO 1 Kick Plate KP50 12” x 2” L.D.W. HB4E CSK 32D MC 1 Mop Plate KP50 4” x 2” L.D.W. HB4E CSK 32D MC 1 Stop WS01 32D MC 1 Gasket MCKS88 BLK MC Functions:

• Door normally closed, latched and secured. • Outside lever always rigid • Key outside retracts latchbolt. Key can only be removed in locked position. • Latchbolt retracted by lever from inside at all times.

Page 17: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

ASSA ABLOY Township Medical Center

DOOR HARDWARE 08-7100 - 17 OF 17 June 2008 ASSA ABLOY Proj. No. 062008

GROUP-73.0 Exit – Pair – SVR/LBR – Classroom Function 2 Continuous Hinge HG-305 HT MB x Adjust-A-Screw 32D MA 1 SVR Exit 10-12-19-43-SG-NB8710 32D SA 1 SVR Exit 10-12-19-43-63-64-SGNB8743 x 743-8-ETL 32D SA 2 Closers PR7500 689 NO 2 Armor Plates KP50 38” x 1” L.D.W. HB4E CSK 32D MC 2 Mop Plates KP50 4” x 1” L.D.W. HB4E CSK 32D MC 2 Edge Guard EG11 32D MC 2 Wall Holders ADH01 26D MC 1 Gasket MCKS88 BLK MC 1 Astragal MCKS77 BLK MC 2 Auto Door Bottoms MCK4131SNRL(Semi Mortised) SN MC Function:

• Both doors normally closed, latched and secured. • Depressing touchpad on either door from inside allows free egress at all times. • Outside Lever locked or unlocked by key outside.

GROUP-113.2 Locked – Exit - Closer - Classroom Function

3 Hinges T4A3386 5” x 4.5” NRP US32D MC 1 Lockset 10-16-43-63-64-PL-SG 8816 ETP 32D SA 1 Closer PR7500 689 NO Note: Install weatherstrip before installation of door closer. 1 Kick Plate KP50 12” x 2” L.D.W. HB4E CSK 32D MC 1 Wall Holder/Stop DS22 26D MC 1 Door Viewer DV3 625 MC 1 Threshold MCK273X3AFG AL MC 1 Set Weatherstrip MCK2891APK AL MC 1 Sweep Strip MCK315N AL MC 1 Auto Door Bottom MCK420PKL AL MC

Functions: • Door normally closed, latched and secured. • Key outside retracts latchbolt. • Key inside locks/unlocks outside lever. • Depressing touchpad inside always allows free egress. • Depressing touchpad and rotating cylinder on exit device end rail holds latchbolt and touchpad

retracted for push/pull operation. o Holding touchpad and rotating cylinder on exit device end rail releases latchbolt and

touchpad extending latchbolt securing door. • Photoluminescent coating on exit device touchpad produces visible “EXIT” signage in low and

dark lit lighting. Recharges in ambient light.

END OF SECTION 08-7100

Page 18: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Architect Door

Number Location Qty Door Size ThicknessDoor

MaterialDoor Type

Fire Label (Min)

S Label (Y/N)

Frame Material

Frame Type Hand Jamb Head Sill

Hardware Set Notes/Remarks/Comments

01 Exterior From Reception 100 1 PR 3'0" X 7'0" 1 3/4" Glass Sliding Alum SL-3 N/A 21.0 Besam "Unislide OC-S " Full Breakout02 Dock From Chapel 105 1 3'- 6" x 7'-0" 1 3/4" HM F HM HM-8 RHR 113.203 Dock From Morgue 111 1 4'-0" x 7'-0" 1 3/4" HM F HM HM-8 LHR 113.204 Reception 100 To Outpatient Wait 103 1 3'-0" x 7'-0" 1 3/4" WD N 20 HM HM-2 LHR 13.005 Outpatient Wait To/From Nurses Station 121 1 PR 3'0" X 7'0" 1 3/4" Glass Sliding Alum SL-3 N/A 21.0 Besam "Unislide OC-S " Fixed Sidelite06 Nurses Station 121 To Surgery Prep 104 1 3'-4" x 7'-0" 1 3/4" WD N Y HM HM-3 LH 31.007 Staging 106 From Surgery Prep 104 1 3'-4" x 8'-0" 1 3/4" PLAM HG Y HM HM-3 LHR 31.208 Staging 106 To Chapel 105 1 3'-4" x 8'-0" 1 3/4" WD F HM HM-2 LH 16.209 Janitor Closet 110 From Staging 106 1 3'-0" x 7'-0" 1 3/4" HM F HM HM-2 LHR 4.010 Staging 106 From Surgery 107 1 PR 4'-0" x 8'-0" 1 3/4" PLAM N 60 Y HM HM-7 RHR/LHR 73.011 Drug Storage 109 From Nurses Prep 108 1 2'-6" x 7'-0" 1 3/4" HM F 60 HM HM-1 RHR 40.012 Nurses Prep 108 To Morgue 111 1 4'-0" x 8'-0" 1 3/4" PLAM F 90 HM HM-1 RH 33.2 Hospital Stops13 Surgery 107 To Op Room 3 1 4'-0" x 8'-0" 1 3/4" PLAM N HM HM-4 RH 33.2 Hospital Stops14 Surgery 107 To Op Room 2 1 4'-0" x 8'-0" 1 3/4" PLAM N HM HM-4 LH 33.2 Hospital Stops15 Surgery 107 To X-Ray Room 1 1 4'-0" x 8'-0" 1 3/4" PLAM N HM HM-4 RH 33.2 Hospital Stops16 Staging 106 To Nurses Locker 115 1 3'-4" x 7'-0" 1 3/4" WD F 20 Y HM HM-3 LH 40.217 Staging 106 To Doctors Lock116 1 3'-4" x 7'-0" 1 3/4" WD F 20 Y HM HM-3 RH 40.218 Staging 106 From Recovery 117 1 3'-8" x 7'-0" 1 3/4" PLAM HG Y HM HM-5 RHR 31.319 Nurses Station 117 From Recovery 117 1 3'-8" x 7'-0" 1 3/4" WD HG Y HM HM-5 LHR 31.320 Discharge 120 To Admin Office 118 1 3'-0" x 7'-0" 1 3/4" WD N HM HM-2 LH 3.021 Discharge 120 To Medical Supplies 119 1 3'-6" x 7'-0" 1 3/4" HM F 60 HM HM-1 LH 40.222 Reception Area 100 From Discharge 120 1 3'-0" x 7'-0" 1 3/4" WD N 20 HM HM-1 LHR 11.323 Nurses Station 121 To/From Staging 106 1 PR 3'0" X 7'0" 1 3/4" Glass Sliding Alum SL-3 N/A 21.0 Besam "Unislide OC-S " Fixed Sidelite

Page 19: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

1

Reception 100

Outpatient Waiting

103

Surgery Prep104

Chapel105

Surgery107

NursesLockerRM115

DoctorLockers116

Recovery117

Administration118

DrugStorage109

Staging106

ASSA ABLOY Township Medical Clinic

Toilet101

Toilet102

Vending

NursesStation

121

Discharge120

Morgue111

Dock

X-Ray Room114

Operating RM # 2

113

Operating RM # 3

112

Jan110

Nurses / Prep108

MedicalSupplies

119

1

23

4

5

6

7

89

10

1112

13

14

15

16

171819

2021

22

23

Floor Plan

Page 20: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Harmony Cylindrical Door 16

28 - H1 - - 24V - LP - 26D - LH - List Price60SG Spec. Inst.

Hand

Finish

Rose/Lever

Voltage

Function

Type $1,100.00

Series $0.00

Prefix $21.00

$1,121.00

Left

10G270

24 Volts DC

L Rose and P Lever

Satin Chrome

28) ANSI Strike 60) Construction Core SG) MicroShield

Harmony Lockset

Sargent 10 Line Bored Lockset

Fail Safe

Page 21: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Harmony Cylindrical Door 16

- - - - - - - List Price

Spec. Inst.

Hand

Finish

Rose/Lever

Voltage

Function

Type

Series

Prefix

Page 22: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Harmony Mortise Door 11

60 - H1 - - 24V - LNP 26D - RHR - List PriceSG

Spec. Inst.

Hand

Finish

Rose/Lever

Voltage

Function

Type $1,202.00

Series $0.00

Prefix $31.00

$1,233.00

24 Volts DC

LN Rose

Satin Chrome

60) Construction Core SG) MicroShield

Harmony Lockset

Sargent 82 Mortise Lockset

271 = Fail Secure

RH Reverse

82271

Page 23: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Harmony Mortise Door 11

- - - - - - List Price

Spec. Inst.

Hand

Finish

Rose/Lever

Voltage

Function

Type

Series

Prefix

Page 24: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Harmony Rim Exit Door 2

19 - H1 - - 24V - ETP - 32D - RHR - 36" List Price60SG Spec. Inst.

Hand

Finish

Trim/Lever

Voltage

Function

Type $1,889.00

Series $0.00

Prefix $52.00

$1,941.00

24 Volts DC

Exit Trim with P Lever

Stainless Steel

19) w/o Lexan 60) Construction Core SG) MicroShield

Harmony Lockset

Sargent 88 Series Exit Device

Fail Secure

RH Reverse

Door Width8876F

Page 25: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Harmony Rim Exit Door 2

- - - - - - - List Price

Spec. Inst.

Hand

Finish

Trim/Lever

Voltage

Function

Type

Series

Prefix

Page 26: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Access 600 Mortise Door 11

(n/a) ML20605 tcRNE1 PSA 626C RHR (n/a) CT6D M802 24ADVoltage

Tech Option

Cylinder Option

Strike Option

Hand:

Finish:

Trim

Technology Code

Series/Function

Keyset

Mortise Lockset - Fail Secure w/Key override

(Keys & Cylinders are being supplied by Owner)

Right Hand Reverse

Satin Chrome with MircroShield

Princeton Lever & A rose

Access 600

HID 125 kHz

24 VDC

6 pin - Disposable Core

Page 27: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Access 600 Mortise Door 11

Voltage

Tech Option

Cylinder Option

Strike Option

Hand:

Finish:

Trim

Technology Code

Series/Function

Keyset

Page 28: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Access 600 Rim Exit Door 2

(N/A) x ED5200N x PR9605 x tcRNE1 x 630C x RHR x (N/A) x CT6D x M802 x 24ADVoltage

Tech Option

Cylinder Option

Door Width

Hand:

Finish:

Technology Code

Trim/Function

Exit Device

Keyset

Rim Exit Device for use with tcRNE1

(Keys & Cylinders are being supplied by Owner)

Right Hand Reverse

Stainless Steel with MircroShield

Access 600

Princeton Lever w/Fail Secure Trim and Key override

HID 125 kHz

24 VDC

6 pin - Disposable Core

Page 29: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Access 600 Rim Exit Door 2

x x x x x x x x xVoltage

Tech Option

Cylinder Option

Door Width

Hand:

Finish:

Technology Code

Trim/Function

Exit Device

Keyset

Page 30: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Access 600 Cylindrical Door 16

(N/A) x CL33603 x tcRNE1 x PZD x 626C x LH x (N/A) x CT6D x M802 x 24ADVoltage

Tech Option

Cylinder Option

Strike Option

Hand:

Finish:

Trim

Technology Code

Series/Function

Keyset

HID 125 kHz

24 VDC

6 pin - Disposable Core

4 7/8 standard - option for 2 3/4 is M020

Cylinderical lockset - Fail Safe - Key override

(Keys & Cylinders are being supplied by Owner)

Left Hand

Satin Chrome with MircroShield

Princeton Lever with D rose

Access 600

Page 31: ASSA ABLOY Township Medical Center SECTION 08-7100 DOOR ... · ASSA ABLOY Township Medical Center DOOR HARDWARE 08-7100 - 3 OF 17 June 2008 ASSA ABLOY Proj. No. 062008 D. Installer’s

Access 600 Cylindrical Door 16

x x x x x x x x xVoltage

Tech Option

Cylinder Option

Strike Option

Hand:

Finish:

Trim

Technology Code

Series/Function

Keyset