ASLINK System Product Guide - AnyWire · 2019. 4. 9. · ASLINK System Product Guide...

3
ASLINK System Product Guide ASLINKTERMINATOR [ASLINK Terminator] BT0 -BT0 1/3- AT1 D1 The Products Guide describes individual products. Refer to the Guide as necessary. Function List ASLINKTERMINATOR Transmission waveform shaping Specifications Model [Notes on Safety] Precautions that must be observed in order to use this system safely are indicated as shown below. You must observe these precautions. WARNING CAUTION A WARNING indicates a potentially hazardous situation which, if not handled correctly, could result in death or serious injury. A CAUTION indicates a potentially hazardous situation which, if not handled correctly, may result in personal injury or property damage. WARNING System Safety Always turn off the power before attempting to mount or replace. This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes. Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including the output unit and the output circuit may result in smoking or firing. An external safety device such as a fuse must be installed. Use the AnyWireASLINK within the range of the specifications and conditions shown below. System power supply Separately route high-voltage and power cables Connectors and terminals Do not impose any external loads on the units. Doing so may cause a failure. Do not disconnect or reconnect between the transmission line and slave units. A malfunction may occur. Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system. Although the AnyWireASLINK has a high noise margin, keep the transmission line and I/O cables away from high-voltage and power cables. Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected. Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks. Short-circuits caused by metal objects or mis-wiring are likely to damage the device. CAUTION [Warranty] Warranty period The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location as designated by the original owner. Scope of warranty Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in acordance with the specifi- cations described in this User's Manual, the Company shall replace or repair the defect free of charge, except when it arises as a result of: [1] Misuse or abuse of the Product by the owner; [2] Fault caused by other than the delivered Product; [3] The unauthorized modification or repair of the Product by any person other than the Company's personnel; [4] Any unusual force of nature, disaster or other cause beyond the Company's control. The term "warranty," as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be liable for con- sequential or incidental damages resulting from any malfunction. Repair at cost After the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the troubleshooting and repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes other than within the scope of the warranty as specified above, at the owner's cost.

Transcript of ASLINK System Product Guide - AnyWire · 2019. 4. 9. · ASLINK System Product Guide...

Page 1: ASLINK System Product Guide - AnyWire · 2019. 4. 9. · ASLINK System Product Guide ASLINKTERMINATOR [ASLINK Terminator] BT0-BT0 1/3-D1 AT1 The Products Guide describes individual

ASLINK System Product Guide

ASLINKTERMINATOR [ASLINK Terminator]

BT0

-BT0 1/3-

AT1D1

The Products Guide describes individual products. Refer to the Guide as necessary.

■Function List

ASLINKTERMINATORTransmission waveform shaping

Speci�cationsModel

[Notes on Safety]Precautions that must be observed in order to use this system safely are indicated as shown below. You must observe these precautions.

WARNING CAUTION

A WARNING indicates a potentially hazardous situation which, if not handled correctly, could result in death or serious injury.

A CAUTION indicates a potentially hazardous situation which, if not handled correctly, may result in personal injury or property damage.

WARNING

○ System Safety

○ Always turn off the power before attempting to mount or replace.

This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.

○ Prolonged continuous �ow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including the output unit and the output circuit may result in smoking or �ring. An external safety device such as a fuse must be installed.

○ Use the AnyWireASLINK within the range of the speci�cations and conditions shown below.

○ System power supply

○ Separately route high-voltage and power cables

○ Connectors and terminals

○ Do not impose any external loads on the units. Doing so may cause a failure.○ Do not disconnect or reconnect between the transmission line and slave units. A malfunction may occur.

Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.

Although the AnyWireASLINK has a high noise margin, keep the transmission line and I/O cables away from high-voltage and power cables.

・ Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.・ Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.・ Short-circuits caused by metal objects or mis-wiring are likely to damage the device.

CAUTION

[Warranty]■ Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location as designated by the original owner.

■ Scope of warrantyShould a defect occur in any part of the Product during the foregoing warranty period when it is used normally in acordance with the speci�-cations described in this User's Manual, the Company shall replace or repair the defect free of charge, except when it arises as a result of:[1] Misuse or abuse of the Product by the owner;[2] Fault caused by other than the delivered Product;[3] The unauthorized modi�cation or repair of the Product by any person other than the Company's personnel;[4] Any unusual force of nature, disaster or other cause beyond the Company's control.The term "warranty," as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be liable for con-sequential or incidental damages resulting from any malfunction.

■ Repair at costAfter the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the troubleshooting and repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes other than within the scope of the warranty as speci�ed above, at the owner's cost.

Page 2: ASLINK System Product Guide - AnyWire · 2019. 4. 9. · ASLINK System Product Guide ASLINKTERMINATOR [ASLINK Terminator] BT0-BT0 1/3-D1 AT1 The Products Guide describes individual

-BT0 2/3-

Unit: mm

BT0

② Branching

① Basic

[Connection Example]

[Part name]

20m 40m

50m

10m

Transmission cableLED (green)

Master unit

Slave unit

Slave unit Slave unit

Slave unit

Slave unit

Master unit

Terminator

Terminator

Terminator

[Connection]

NoteConnect one BT0 to the end of the transmission line farthest from the AnyWireASLINK master. Since there is a polarity for DP and DN, correctly connect the terminator.

NoteWhen there is a stay line of 40 m or longer for a trunk line, also connect one BT0 to this terminal.Up to two additional BT0s can be connected.When there are two or more branch systems exceeding 40 m, contact us.

NoteSince this end (20 m + 50 m) is the longest route from the master unit, de�ne the route as a trunk l ine and connect one BT0 to the terminal.

The total extension is the total length of the transmission line to be used.In this �gure, the total extension is 20m+10m +40m+50m=120m.

CAUTION

●Installation of transmission lineAlthough the AnyWireASLINK system has a high noise resistance, keep the transmission line away from high-voltage and power cables.

●This terminator is exclusively for the AnyWireASLINK system.●Since the transmission line has a polarity, be careful not to reverse the connection. Otherwise, it may result in a

transmission failure.●When the terminator is properly connected and the transmission signal is provided, LED (green) lights.

Page 3: ASLINK System Product Guide - AnyWire · 2019. 4. 9. · ASLINK System Product Guide ASLINKTERMINATOR [ASLINK Terminator] BT0-BT0 1/3-D1 AT1 The Products Guide describes individual

-BT0 3/3-

Unit : mm

24.512

.25

2044

Mounting drawing of ADP-A032-φ3.2

1216

24.5

(300) 44

BT0

Black: Connected to transmission line DNRed: Connected to transmission line DP

VCT AWG19×2-line (2-core)

Dedicated adapter (supplied)ADP-A03

2-φ7 (depth 1.7)1.53.2

1.5(10)

[Speci�cations]

■Individual speci�cations

Supply voltage Ambient temperature Ambient humidity Storage temperatureAtmosphereElevation for use *1 Contamination level *2

Resistance to noise

Transmission method Synchronization methodTransmission proceduresConnecting modeNumber of connecting pointsNumber of connecting devices

DC supply superposition total frame cyclic methodFrame/bit synchronization methodProprietary protocol (AnyWireASLINK protocol) Bus method (multi-drop, T-branch, tree type) Up to 512 points (IN: 256 points, OUT: 256 points)Up to 128 devices

■General Specifications

■Transmission specifications

Current consumption Weight

DC24V +15% to -10% (DC21.6 to 27.6V) Ripple 0.5Vp-p or less0 to +55°C10 to 90%RH, free from condensation-25 to +75°CNo corrosive gas0 to 2000 m2 or less1200Vp-p (pulse width 1μs)

2mABT0: 25gADP-A03: 5g

Anywire CorporationHeadquarters :1 Babazusho, Nagaokakyo-shi, Kyoto 617-8550 JAPAN

:Contact by mailContact [email protected]:Contact by website http://www.anywire.jp

Printed in Japan 2015, 2016, 2017 UMA-10492D-EN

[Address]

[Outer Dimensions]

*1 Do not use or store AnyWireASLINK devices in an environment where the pressure is larger than the atmospheric pressure at an elevation of 0 m. A malfunction may occur.

*2 Indicates the degree of occurrence of conducive objects in an environment in which the device is used. At pollution level 2, only non-conducive contaminants occur.However, the environment may cause temporary conduction due to accidental condensation.