Asbestos Containing Materials Assessment 405 Hampton Road Greer, South Carolina 29651 Prepared for: Greenville County Redevelopment Authority 301 University Ridge, Suite 2500 Greenville, South Carolina Prepared by: Apex Environmental Management, Inc. 7 Winchester Court Mauldin, South Carolina 29662 Project Number: 1219-281 January 17, 2020

Transcript of Asbestos Containing Materials Assessment · 2020. 1. 27. · ASBESTOS CONTAINING MATERIALS...

  • Asbestos Containing Materials Assessment 405 Hampton Road

    Greer, South Carolina 29651

    Prepared for: Greenville County Redevelopment Authority

    301 University Ridge, Suite 2500 Greenville, South Carolina

    Prepared by: Apex Environmental Management, Inc.

    7 Winchester Court Mauldin, South Carolina 29662

    Project Number: 1219-281

    January 17, 2020

  • SERVICES

    Indoor Air Quality

    Mold Remediation

    Asbestos & Lead

    Industrial Hygiene

    Worker Health & Safety

    Mold Consulting

    Moisture

    Management Plans

    Safety

    Assessment

    Environmental Site Assessments

    Hazard

    Communication

    7 Winchester Court Mauldin, SC 29662 864.404.3210 office 864.404.3213 fax

    802 E. Martintown Rd Suite 208 N. Augusta, SC 29841 803.440.2790 office www.apex-ehs.com

    Apex Project Number 1219-281

    January 17, 2020

    Ms. Meg Macauley Greenville County Redevelopment Authority 301 University Ridge, Suite 2500 Greenville, South Carolina 29601 Reference: Asbestos Containing Materials Assessment Services 405 Hampton Road

    Greer, South Carolina 29651 Dear Ms. Macauley: Apex Environmental Management, Inc. (Apex) is pleased to provide the results of our assessment services for the referenced property. This report and the associated attachments summarize our evaluation of the conditions observed at the project site. The findings presented by Apex are based upon sampling performed in the subject building. There is a chance that undetected ACM may exist in the building between walls or in other areas that would only be exposed during demolition or structural renovations. Should material be discovered that could potentially contain asbestos during the demolition process, additional samples of the material should be collected by a licensed asbestos inspector and submitted to an accredited laboratory for analytical interpretation. Our recommendations are based on the guidelines presented in EPA and/or OSHA regulations. Please note that this document is not a specification for asbestos removal. It does not contain means and methods for abatement. Quantities are estimates and contractors must verify amounts prior to bidding or removal. If you are planning an abatement project, please contact Apex to discuss the requirements. Use of this document without the express written consent of Apex is at the sole risk of the user and or/abatement contractor. The conclusions and/or recommendations contained in this report are based on our understanding of the applicable standards at the time this report was prepared. No warranty, expressed or implied, is made. If you have any questions please feel free to contact us at (864) 404-3210. Respectfully submitted, APEX ENVIRONMENTAL MANAGEMENT, INC. Tom Oliver Vice President Appendices

  • ASBESTOS CONTAINING MATERIALS ASSESSMENT

    GREENVILLE COUNTY REDEVELOMENT AUTHORITY 405 HAMPTON ROAD

    GREER, SOUTH CAROLINA 29651

    APEX PROJECT NO. 1219-281

    TABLE OF CONTENTS SECTION

    I Asbestos Evaluation Report II Asbestos PLM & TEM Data Results Table III Laboratory Analytical Results & Chain of Custody IV Photographic Log

    V SC DHEC Asbestos Inspector License

  • SECTION I

    Asbestos Evaluation Report

  • 1

    Date:

    1/17/2020 Page Number: 1 of 3

    Client: Greenville County Redevelopment Authority

    Client Contact: Ms. Meg Macauley

    Client Address:

    301 University Ridge Suite 2500 Greenville, SC 29601

    Client Phone Number:

    (864) 242-9801

    Project:

    Asbestos Evaluation

    Property Address:

    405 Hampton Road Greer, SC 29651

    Assessor: Ted Shultz Date of

    Assessment:12/05/2019

    Company:

    Apex Environmental Management 7 Winchester Court Mauldin, SC 29662

    Phone Number:

    (864) 404-3210

    Purpose of Assessment:

    Demolition Age of Structure:

    Approximately 30 years

    Building Type:

    Residential Mobile Home Number of Stories:

    1

    Foundation: Crawlspace Approximate Square Footage

    1,000 SF

    EXTERIOR BUILDING MATERIALS INTERIOR BUILDING MATERIALS Roof with shingles with felt & paper. Brick & T-1-11 siding. Vinyl windows with grey & white caulks. Metal doors with no caulk. Wooden front porch

    Drywall with joint compound and tape throughout.

    Ceiling texture throughout. Carpet over wooden floors. Multiple types & layers of vinyl flooring

    with no mastics.

    ASBESTOS EVALUATION REPORT APEX PROJECT NUMBER: 1219-281

  • Greenville County Redevelopment Authority 405 Hampton Road Apex Project No. 1219-281 January 17, 2020

    2

    SCOPE OF THE SURVEY The objectives of the asbestos containing materials assessment included the following:

    Identification of suspect asbestos-containing material (ACM) in readily observable locations. Limited demolition of building finishes was conducted.

    Asbestos survey with sample collection by a South Carolina accredited inspector. Suspect ACM analysis by polarized light microscopy (PLM) utilizing Southeast

    Environmental Microbiology Laboratories (SEEML) as an NVLAP certified laboratory, their accreditation number is 201031-0.

    Transmission electron microscopy (TEM) analysis of non-friable organically bound materials suspected to contain asbestos and testing negatively by PLM analysis were analyzed by Airtek Environmental as an NVLAP certified laboratory, their accreditation number is 102011-0.

    Presenting the results in a report identifying confirmed ACMs. METHODS In order to determine if the suspect materials observed during the visual survey contained asbestos, representative bulk samples were collected and placed in sealed packages. Twenty-six (26) bulk samples were collected during the survey and submitted to SEEML in Greenville, South Carolina for analysis using the EPA recommended method of Polarized Light Microscopy (PLM) coupled with dispersion staining (Method No. EPA 600/M4-82-020, Dec. 1982). SEEML participates in the National Voluntary Laboratory Accreditation Program (NVLAP). Their NVLAP accreditation numbers are 201031-0. EPA regulations require that multiple samples of each homogeneous material be collected for laboratory analysis. In accordance with South Carolina Regulation 61-86.1, non-friable organically bound materials that are reported to be non-asbestos containing by PLM analysis must also be analyzed by Transmission Electron Microscopy (TEM). Six (6) samples were analyzed using TEM. RESULTS The EPA defines an asbestos-containing material (ACM) as a material containing more than 1% asbestos. OSHA defines ACM as a material containing detectable amounts of asbestos. A specific PLM and TEM Data Results Table is located in Appendix II of this report and identifies positive materials and designates approximate quantities. Suspect asbestos containing materials that were identified to be asbestos containing include:

    Approximately 8 vinyl windows with grey caulk.

  • Greenville County Redevelopment Authority 405 Hampton Road Apex Project No. 1219-281 January 17, 2020

    3

    RECOMMENDATIONS AND DISCUSSION If the above referenced asbestos materials are to be disturbed by renovations or demolition, the asbestos must be removed in accordance with EPA, State of South Carolina and OSHA asbestos regulations. The State of South Carolina, Department of Health and Environmental Control (DHEC) has specific regulations that must be adhered to during asbestos removal/abatement projects. Apex recommends the following: 1. Abate the asbestos containing materials in the structure prior to renovation or demolition. 2. Follow applicable asbestos regulations during renovation or demolition of the structure. You

    should be aware that stringent requirements are imposed upon anyone renovating or demolishing a structure in which ACM will be disturbed. This work must be performed in accordance with OSHA asbestos regulations, 29 CFR 1910 & 1926, and NESHAP asbestos regulations 40 CFR 61, subpart M. South Carolina regulations require the accreditation of personnel who work in the asbestos field and notification and permitting fees for asbestos removal projects. There is a 10 working day notification period required prior to abatement of asbestos in a facility. Failure to take proper precautions and actions to protect human health and the environment can result in penalties, danger to personnel, and construction delays.

    Please note that this document is not a specification for asbestos removal. It does not contain means and methods for asbestos abatement. If you are planning an asbestos abatement project, please contact Apex to discuss the requirements. Use of this document without the express written consent of Apex is at the sole risk of the user and/or abatement contractor. Quantities provided in this report are estimated. Contractors must verify material amounts prior to bidding or removal. This report summarizes our evaluation of the conditions observed at the site. The findings prepared by Apex are based upon testing performed in the building space. Additional ACM may exist (undetected) in other areas due to their inaccessibility or due to the limited nature of our testing. Our assessment procedures and recommendations are based on the guidelines presented in EPA, State of South Carolina or OSHA asbestos regulations. A copy of this report must be submitted to SCDHEC at least ten (10) working days prior to demolition when applying for a demolition permit.

  • SECTION II

    Asbestos PLM & TEM Data Results Table

  • Project Name: Sampled By: Ted Shultz

    Project Location: Project Manager: Ted Shultz

    Project Number: Date: 12/5/2019

    123 TEM - NAD456 TEM - NAD789 TEM - NAD101112131415 TEM - NAD161718 TEM - NAD1920212223242526

    NAD = No Asbestos Detected LF = Linear Feet EA = Each Amos = Amosite

    Bold = Positive For Asbestos SF = Square Feet Chry = Chrysotile

    Exterior windows Grey caulk Non-Friable Good 8 EA

    Exterior windows Window caulk Non-Friable Good 8 EA

    PLM - 2% anthophylite

    PLM - NAD

    Master bedroom closet

    Tan square pattern vinyl floor with no mastic

    PLM - NADNon-Friable Good 25 SF

    Throughout Ceiling texture PLM - NAD Friable Good 950 SF

    Throughout walls & ceilings

    Drywall with joint compound & tape PLM - NAD Friable Good 2,700 SF

    Both bathrooms Peach marble pattern vinyl floor with no mastic

    Roof Roof shingle (2 layers) with felt paper (1 layer) & paper

    130 SFPLM - NAD

    Non-Friable Good 70 SF

    Non-Friable Good 1,000 SF

    PLM - NAD

    PLM - NAD

    Sample No. ConditionSample Description

    Kitchen Brown self-stick floor tile over off white self-stick floor tile GoodNon-Friable

    GCRA 405 Hampton Road ACM

    405 Hampton Road, Greer, SC 29651

    1219-281

    PLM & TEM RESULTSASBESTOS SURVEY FIELD DATA SHEET

    QuantityAnalytical Results Friable/Non FriableLocation

  • SECTION III

    Laboratory Analytical Results & Chain of Custody

  • SEEML Reference Number: 191205009-PLM Date: 12/12/19

    Form 16 Rev. 5 11/22/19

    Southeast Environmental Microbiology Laboratories 102 Edinburgh Court

    Greenville, SC. 29607

    Phone: (864) 233-3770

    Fax: (864) 233-6589

    Asbestos Analytical Report By: Polarized Light Microscopy

    This report has been prepared for Apex Environmental Management the information and data has been checked for thoroughness and accuracy. The results reported relate only to the materials received and tested.

    The documents(s) contained herein are confidential and privileged information intended for the exclusive use

    of the individual or entity named above.

    Client Project Name: ACM 405 Hampton Rd

    The Following report was prepared using this test method(s) contained within this document.

    PLM Bulk Asbestos Fiber Analysis: EPA 600/R-93/116 and EPA 600/M4-82/020

    PLM 400 Point Count (

  • Texas Lic: 300474

    Client:

    Methodology:

    19/6Lab No.:

    Client No.:

    061A

    1

    061B

    1

    062A

    2

    062B

    2

    063A

    3

    063B

    3

    064A

    4

    065A

    5

    066A

    6

    067A

    7

    Form 8.0 Rev. 7 11/07/19

    Tan Vinyl Tile- Kitchen Floor

    Vinyl Floor- Peach Marble-

    Bathroom Floor40% Residue

    Tan Tile- Kitchen Floor

    Sent For TEM

    Sent For TEM

    Greer, SC

    405 Hampton Rd

    27% Residue

    Brown Tile- Kitchen Floor

    2% Residue

    191205009-PLMSEEML Ref#:

    25% Residue

    Description/Location

    Brown Tile- Kitchen Floor

    Tan Tile- Kitchen Floor

    Brown Tile- Kitchen Floor

    3% Residue

    % Non-Fibrous Material

    EPA/600/R-93/116 Without Gravimetry

    Project No:

    Analyzed by: Jayson DunnCity, State. ZIP:

    Project Address:

    20% Fiberglass

    3% Fiberglass

    5% Fiberglass

    None Detected

    Sent For TEM

    Regular/Split Layers Analyzed:

    None Detected

    2% Fiberglass

    2% FiberglassNone Detected

    % Asbestos Type% Fibrous Non-

    Asbestos Material Type

    None Detected

    Southeast Environmental Microbiology Laboratories - Asbestos Division

    102 Edinburgh Court Greenville, SC 29607

    Phone: 864-233-3770, Fax: 864-233-6589 , www.seeml.com

    Date Sampled:

    Date Received:

    Apex Environmental Management

    PLM Asbestos Bulk Sample Summary

    12/05/19

    12/05/19R. Shultz

    NVLAP Lab ID:201031-0

    Approved by: Azzeddine Barakat

    10% Residue Roof Shingle

    Vinyl Floor- Peach Marble-

    Bathroom Floor

    None Detected

    None Detected 41% Residue Vinyl Floor- Peach Marble-

    Bathroom Floor

    None Detected

    None Detected

    None Detected

    Date Revised:864-404-3210

    7 Winchester Court

    Mauldin, SC 29662

    12/12/19Date Analyzed:

    Date Reported:

    Project Name:

    12/12/19

    ACM 405 Hampton Rd

    Page 2 of 5

  • Texas Lic: 300474

    Client:

    Methodology:

    19/6Lab No.:

    Client No.:

    067B

    7

    067C

    7

    068A

    8

    068B

    8

    068C

    8

    069A

    9

    070A

    10

    071A

    11

    072A

    12

    073A

    13

    Form 8.0 Rev. 7 11/07/19

    Approved by: Azzeddine Barakat

    Sent For TEM

    Positive Stop

    Positive Stop Grey Caulk-Ext. Window

    None Detected None Detected 7% Residue White Caulk-Ext.Window

    2% Anthophyllite None Detected 98% Organic Matrix Grey Caulk-Ext. Window

    Grey Caulk-Ext. Window

    None Detected 80% Cellulose 20% Organic Matrix Paper

    Roofing

    None Detected 30% Fiberglass 20% Residue Roof Shingle

    None Detected 10% Fiberglass 10% Residue Felt Paper

    None Detected 5% Fiberglass 5% Residue Felt Paper

    None Detected 80% Cellulose 20% Organic Matrix Paper

    EPA/600/R-93/116 Without Gravimetry SEEML Ref#: 191205009-PLM

    Regular/Split Layers Analyzed:

    % Asbestos Type% Fibrous Non-

    Asbestos Material Type% Non-Fibrous Material Description/Location

    Analyzed by: Jayson DunnProject Address: 405 Hampton Rd

    City, State. ZIP: Greer, SC

    Project Name: ACM 405 Hampton Rd

    Project No:

    Mauldin, SC 29662 Date Reported: 12/12/19

    864-404-3210 Date Revised:

    R. Shultz Date Received: 12/05/19

    7 Winchester Court Date Analyzed: 12/12/19

    Southeast Environmental Microbiology Laboratories - Asbestos Division

    102 Edinburgh Court Greenville, SC 29607

    Phone: 864-233-3770, Fax: 864-233-6589 , www.seeml.com

    NVLAP Lab ID:201031-0

    PLM Asbestos Bulk Sample Summary

    Apex Environmental Management Date Sampled: 12/05/19

    Page 3 of 5

  • Texas Lic: 300474

    Client:

    Methodology:

    19/6Lab No.:

    Client No.:

    074A

    14

    075A

    15

    076A

    16

    077A

    17

    078A

    18

    079A

    19

    080A

    21

    081A

    21

    082A

    22

    083A

    23

    Form 8.0 Rev. 7 11/07/19

    Approved by: Azzeddine Barakat

    Sent For TEM

    Sent For TEM

    None Detected 3% Cellulose 97% Gypsum Drywall-Throughout Walls And

    Ceiling

    None Detected 5% Cellulose 95% Gypsum Drywall-Throughout Walls And

    Ceiling

    None Detected None Detected 100% Binder/Filler Ceiling Texture

    None Detected None Detected 100% Binder/Filler Ceiling Texture

    Tan Vinyl Floor-Master Closet

    None Detected None Detected 100% Binder/Filler Ceiling Texture

    None Detected None Detected 22% Residue Tan Vinyl Floor-Master Closet

    None Detected None Detected 24% Residue Tan Vinyl Floor-Master Closet

    None Detected None Detected 7% Residue White Caulk-Ext. Window

    White Caulk-Ext. Window

    EPA/600/R-93/116 Without Gravimetry SEEML Ref#: 191205009-PLM

    Regular/Split Layers Analyzed:

    % Asbestos Type% Fibrous Non-

    Asbestos Material Type% Non-Fibrous Material Description/Location

    Analyzed by: Jayson DunnProject Address: 405 Hampton Rd

    City, State. ZIP: Greer, SC

    Project Name: ACM 405 Hampton Rd

    Project No:

    Mauldin, SC 29662 Date Reported: 12/12/19

    864-404-3210 Date Revised:

    R. Shultz Date Received: 12/05/19

    7 Winchester Court Date Analyzed: 12/12/19

    Southeast Environmental Microbiology Laboratories - Asbestos Division

    102 Edinburgh Court Greenville, SC 29607

    Phone: 864-233-3770, Fax: 864-233-6589 , www.seeml.com

    NVLAP Lab ID:201031-0

    PLM Asbestos Bulk Sample Summary

    Apex Environmental Management Date Sampled: 12/05/19

    Page 4 of 5

  • Texas Lic: 300474

    Client:

    Methodology:

    19/6Lab No.:

    Client No.:

    084A

    24

    085A

    25

    086A

    26

    Form 8.0 Rev. 7 11/07/19

    Approved by: Azzeddine Barakat

    None Detected 3% Cellulose 97% Gypsum Drywall-Throughout Walls And

    Ceiling

    None Detected 5% Cellulose 95% Gypsum Drywall-Throughout Walls And

    Ceiling

    None Detected 2% Cellulose 98% Gypsum Drywall-Throughout Walls And

    Ceiling

    EPA/600/R-93/116 Without Gravimetry SEEML Ref#: 191205009-PLM

    Regular/Split Layers Analyzed:

    % Asbestos Type% Fibrous Non-

    Asbestos Material Type% Non-Fibrous Material Description/Location

    Analyzed by: Jayson DunnProject Address: 405 Hampton Rd

    City, State. ZIP: Greer, SC

    Project Name: ACM 405 Hampton Rd

    Project No:

    Mauldin, SC 29662 Date Reported: 12/12/19

    864-404-3210 Date Revised:

    R. Shultz Date Received: 12/05/19

    7 Winchester Court Date Analyzed: 12/12/19

    Southeast Environmental Microbiology Laboratories - Asbestos Division

    102 Edinburgh Court Greenville, SC 29607

    Phone: 864-233-3770, Fax: 864-233-6589 , www.seeml.com

    NVLAP Lab ID:201031-0

    PLM Asbestos Bulk Sample Summary

    Apex Environmental Management Date Sampled: 12/05/19

    Page 5 of 5

  • Test Report: Asbestos Analysis of Bulk Material

    Airtek Project No.: 19-0706

    SEEML Labs102 Edinburgh Ct.

    Greenville , SC 29607

    Project Address: 405 Hampton Rd.

    Greer, SC

    Attn:

    Address:

    Fax: Phone:

    Project Manager:

    Sample Description / Test Fibrous Non-Fibrous Asbestos Comment Vermiculite

    Company:

    39-37 29th StreetLong Island City, NY 11101Phone: (718) 937-3720 Fax: (718) 937-3721

    Sample 19-0662-3A Brown Tile/Kitchen Floor

    Layer 1

    2.84% ResidueTEM NYS 198.4 NOB 12/11/2019 Not Analyzed

    Sample 19-0662-3B Tan Tile/Kitchen Floor

    Layer 1

    26.36% ResidueTEM NYS 198.4 NOB 12/11/2019 Not Analyzed

    Sample 19-0662-6 Peach Marble Vinyl

    Layer 1

    7.62% ResidueTEM NYS 198.4 NOB 12/41/2019 Not Analyzed

    Sample 19-0662-9 Roof Shingl + Felt

    Layer 1

    None Detected

    42.91% ResidueTEM NYS 198.4 NOB 12/11/2019 Not Analyzed

    Sample 19-0662-15 White Caulk/Exterior Window

    Layer 1

    None Detected7.27% ResidueTEM NYS 198.4 NOB 12/11/2019 Not Analyzed

    Page 1 of 2Monday, December 16, 2019

  • Method: PLM with EPA 600/M4/82/020, ELAP 198.1 and ELAP 198.6; TEM by ELAP 198.4Methods of stratified point-counting or negative scanning are used on at least 4 mounts, as per 198.1Polarized light microscopy is not consistently reliable in detecting asbestos in floor covering/non-friable organically bound materials (NOB's). NOB's should be analyzed by quantitative TEM. The above test report relates only to item tested. Layered samples are analyzed by layer. Any positive layer will be reported separately. Asbetos percentage is based on point-counting rules described in ELAP 198.1*VERMICULTE NOTE DISCLAIMER: Samples that contain more than 10% vermiculite are re-analyzed by ELAP method 198.6. This method does not remove verimculite and may underestimatethe level of asbestos containing greater than 10% vermiculite.Attic fill, block fill or other loose bulk Vermiculite materials must be designated and treated as ACM per NYSDOHAll Surfacing Materials containing vermiculite must be analyzed by a laboratory approved for ELAP 198.8Airtek collects samples in accordance with EPA 40 CFR Part 763.This report should not be used to claim product certification, approval or endorsement by NVLAP,NIST or any agency of the federal government and may not be reproduced, except in full, without written approval by Airtek.Currently approved by ELAP (11040) for Asbestos in Friable Material item 198.1 and EPA 600/M4/82/020, asbestos in Non Friable Materials 198.6 (NOB by PLM) and asbestos in Non FriableMaterial 198.4 (TEM)Currently accredited by the NVLAP lab code 102011-0 for Bulk Asbestos Analysis (PLM) EPA 600/M4/82/020.This report relates only to the samples reported above and must not be reproduced except in full with the approval of the laboratory.

    Fahrudin Lalic, Lab AnalystAnalysts: Fahrudin Lalic

    Page 2 of 2

    Sample 19-0662-18 Tan Square Vinlyl/Closet

    Layer 1

    None Detected25.54% ResidueTEM NYS 198.4 NOB 12/11/2019 Not Analyzed

    Monday, December 16, 2019

  • SECTION IV

    Photographic Log

  • Asbestos Containing Materials Assessment 405 Hampton Road Greer, South Carolina

    Photo 1 – 405 Hampton Road in Greer, South Carolina Photo 2 – Shingles and felt.

    Photo 3 – Brick exterior on 3 sides. Photo 4 – Wood pattern floor tile.

    Photo 5 – Tan vinyl flooring 2nd layer in kitchen.

    Photo 6 – Bathroom flooring.

  • Asbestos Containing Materials Assessment 405 Hampton Road Greer, South Carolina

    Photo 7 – Ceiling texture.

  • SECTION V

    SC DHEC Asbestos Inspector License

  • 191205009-PLM.pdfSheet1Sheet1 (2)Sheet1 (3)Sheet1 (4)