UP D E 2 3 -0.050 SSL 100 1660 2400 5200 1000 UP DN D E 2 3 5200 +3.125 SSL 2400 1660 8 @ 280 = 2240 1300 1660 8 @ 280 = 2240 1100 200 1100 DN D E 2 3 +6.585 SSL 5200 2400 1240 1380 9 @ 280 = 2520 1300 1100 200 1100 2 3 -0.050 SSL +3.125 SSL +6.585 SSL 175 +9.525 TOH +9.025 TOH FLB6A 175 1805 (10 EQ. RISERS) 188 1422 (8 EQ. RISERS) +4.780 SSL +1.560 SSL 175 PLINTH AT ROOF LEVEL NOT SHOWN IN SECTION FOR CLARITY FL2 FL1 FL3 FL4 125 +10.785 TOB (TYP) 1440 (8 EQ. RISERS) 215 175 175 CAPPING BEAM (TYP) 1680 T8- 200 (TYP) 2T10 (TYP) 1422 (8 EQ. RISERS) 143 175 175 T8-200 (FULL HEIGHT OF WALL) TRCB5 RCB2A FCB1 100 320 FLB6 +6.325 TOH TRCB3 100 510 500 CONSTRUCTION JOINT 4- T12 T8- 200 CONCRETE FILLED HOLLOW BLOCK 3 8T12 (EQUALLY PLACED) T10-200 T10-200 T10-200 8T12 T10-200 8T12 600 600 REFER ARCHITECTURAL DRAWINGS FOR EXACT SHAPE & SIZE OF STEP (TYP) FL1 600 1040 2335 3015 1970 8- T12 T12- 200 T10- 200 600 600 600 FL2 8- T12 8- T12 8- T12 T10- 200 600 T10- 200 3 2 REFER ARCHITECTURAL DRAWINGS FOR EXACT SHAPE & SIZE OF STEP (TYP) 1390 2905 1360 2450 REFER DETAIL 7 T10- 200 T12- 200 D E D E -0.050 SSL +9.525 TOH RCB2 RCB2 TRCB4 TRCB4A +3.125 SSL +10.785 TOB +6.585 SSL FCB2 FCB2 100 +6.325 TOH 1 : 50 GROUND FLOOR PLAN 1 1 : 50 FIRST FLOOR PLAN 2 1 : 50 ROOF LEVEL PLAN 3 SECTION SCALE 1 : 50 B 5 1 : 20 STAIR - FLIGHT- 1 REINFORCEMENT DETAILS 6 1 : 20 STAIR - FLIGHT- 2 REINFORCEMENT DETAILS 7 SECTION SCALE 1 : 20 C 8 REINFORCEMENT FOR FLIGHT FL3 & FL4 SIMILAR TO FLIGHT FL2 SECTION SCALE 1 : 50 A 4 NASS KHARAFI JV AB PROJECT: DRG.TITLE. AS SHOWN 110236 - AB - ST-01 - 005 VILLA TYPE 1 + 1A STAIRCASE DETAILS 1. DO NOT SCALE FROM THE DRAWINGS. 2. ALL DIMENSIONS ARE IN MILLIMETRES. NOTES: Consultant: Client: FAX: TELEPHONE: EMAIL: +973 1713 1252 +973 1751 0400 [email protected] Level 11, East Tower Bahrain World Trade Centre P.O Box 5668, Manama Kingdom of Bahrain MINISTRY OF HOUSING P.O. BOX 5802,MANAMA,KINGDOM OF BAHRAIN ,TEL:+973 17 533000, FAX: +973 17 533836 KINGDOM OF BAHRAIN STRATEGIC PROJECTS SECTION EAST HIDD HOUSING DEVELOPMENT CONSTRUCTION & MAINTENANCE OF 483 VILLAS MANAMA, KINGDOM OF BAHRAIN A1 Consultant: P.O. Box 50900, Manama Kingdom of Bahrain TEL: +973 17 822666 FAX: +973 17 820666 EMAIL: [email protected] AS BUILT

Transcript of AS BUILThousing.gov.bh/ar/Projects/HousingDesign/HousesModels/...-0.050 SSL-0.150 FGL 400 400 150...

UP

D

E

2 3

-0.050 SSL

10

0

1660

24

00

5200

10

00

UP

DN

D

E

2 3

5200

+3.125 SSL

24

00

1660

8 @ 280 = 2240

1300

1660

8 @ 280 = 2240

11

00

20

01

10

0

DN

D

E

2 3

+6.585 SSL

5200

24

00

1240

1380

9 @ 280 = 2520

1300

11

00

20

01

10

0

2 3

-0.050 SSL

+3.125 SSL

+6.585 SSL

17

5

+9.525 TOH

+9.025 TOH

FLB6A

1

7

5

18

05

(1

0 E

Q. R

IS

ER

S)

18

8

14

22

(8

E

Q. R

IS

ER

S)

+4.780 SSL

+1.560 SSL

17

5

PLINTH AT ROOF LEVEL NOT SHOWN

IN SECTION FOR CLARITY

FL2

FL1

FL3

FL4

12

5

+10.785 TOB (TYP)

14

40

(8

E

Q. R

IS

ER

S)

21

5

17

5

17

5

CAPPING BEAM

(TYP)

1680

T8- 200 (TYP)

2T10 (TYP)

14

22

(8

E

Q. R

IS

ER

S)

14

3

1

7

5

1

7

5

T8-200

(FULL HEIGHT OF

WALL)

TRCB5

RCB2A

FCB1

10

03

20

FLB6

+6.325 TOH

TRCB3

10

0

510

500

CONSTRUCTION

JOINT

4- T12

T8- 200

CONCRETE FILLED

HOLLOW BLOCK

3

8T12

(EQUALLY PLACED)

T10-200

T10-200

T10-200

8T12

T10-2008T12

6

0

0

6

0

0

REFER ARCHITECTURAL

DRAWINGS FOR EXACT

SHAPE & SIZE OF STEP (TYP)

FL1

600

1040

2

3

3

5

3015

1970

8- T12

T12- 200

T10- 200

6

0

0

6

0

0

600

FL2

8- T12

8- T12

8- T12

T10- 200

600

T10- 200

3

2

REFER ARCHITECTURAL

DRAWINGS FOR EXACT

SHAPE & SIZE OF STEP (TYP)

1390

2

9

0

5

13602450

REFER DETAIL 7

T10- 200

T12- 200

D E

D E

-0.050 SSL

+9.525 TOH

RCB2

RCB2

TRCB4

TRCB4A

+3.125 SSL

+10.785 TOB

+6.585 SSL

FCB2

FCB2

10

0

+6.325 TOH

1 : 50

GROUND FLOOR PLAN

1

1 : 50

FIRST FLOOR PLAN

2

1 : 50

ROOF LEVEL PLAN

3

SECTION

SCALE 1 : 50

B

5

1 : 20

STAIR - FLIGHT- 1

REINFORCEMENT DETAILS6

1 : 20

STAIR - FLIGHT- 2

REINFORCEMENT DETAILS7

SECTION

SCALE 1 : 20

C

8

REINFORCEMENT FOR FLIGHT FL3 & FL4

SIMILAR TO FLIGHT FL2

SECTION

SCALE 1 : 50

A

4

NASS KHARAFI JV

AB

PROJECT:

DRG.TITLE.

AS SHOWN

110236 - AB - ST-01 - 005

VILLA TYPE 1 + 1A

STAIRCASE DETAILS

1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES.

NOTES:

Consultant:

Client:

FAX:

TELEPHONE:

EMAIL:

+973 1713 1252

+973 1751 0400

[email protected]

Level 11, East Tower

Bahrain World Trade Centre

P.O Box 5668, Manama

Kingdom of Bahrain

MINISTRY OF HOUSING

P.O. BOX 5802,MANAMA,KINGDOM OF BAHRAIN ,TEL:+973 17 533000, FAX: +973 17 533836

KINGDOM OF BAHRAIN

STRATEGIC PROJECTS SECTION

EAST HIDD

HOUSING DEVELOPMENT

CONSTRUCTION & MAINTENANCE OF 483 VILLAS

MANAMA, KINGDOM OF BAHRAIN

A1

Consultant:

P.O. Box 50900, Manama

Kingdom of Bahrain

TEL: +973 17 822666

FAX: +973 17 820666

EMAIL: [email protected]

AS BUILT

1 2 3

A

B

C

D

E

F

G

H

UP

5

2 3

11

2

2 4

1

3

2

1

5

3

4

2

4

2

1

2

2

4

2

2

3

4

1

1

2

2

2

2

3

2

2

3

2

1

2

2

2

4

3

5

5

3

5

M. BEDROOM

BATH-2

BEDROOM-2

COURTYARD

BELOW

COURTYARD

BELOW

FAMILY

HALL

BEDROOM-3

ROOF

DECK

BATH-3

BEDROOM-4

ROOF

C

31

E

2

D

A

B

H

F

G

6 6

2

2

1

66

6

6

66

6

6

66

2

2

2

2

4

6 6

4

2

64

6

6

4

3

6

6

3

6

5

62

2

5 2

3

2

3

5

3

5

3

3

3

5

1- T12 (TYP)

1- T12 (TYP)

1- T12 (TYP)

CONCRETE

INFILLED (TYP)

CONCRETE

INFILLED (TYP)

CONCRETE

INFILLED (TYP)

CORNER

INTERSECTION

END

3

2

4

END

1

CONCRETE

INFILLED (TYP)

NON-LOAD BEARING TO

LOAD BEARING WALL

5

INFILL INSULATION WALL

6

OUTSIDE

INSIDE

1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES.

NOTES:

GROUND FLOOR (TYPE 1+1A)

1

RC COLUMN / WALL

LOAD BEARING HOLLOW BLOCK WALL

MINIMUM COMPRESSIVE STRENGTH OF HOLLOW BLOCKS:

* AT ALL OTHER LOCATIONS- 7MPa.

LEGEND:

NON-LOAD BEARING HOLLOW BLOCK WALL

(MINIMUM COMPRESSIVE STRENGTH = 7Mpa)

LOAD BEARING HOLLOW BLOCK WALL

MINIMUM COMPRESSIVE STRENGTH OF HOLLOW BLOCKS:

* ALONG GRID -(2) AT GROUND FLOOR LEVEL- 7MPa WITH

ALL HOLLOW INFILLED WITH CONCRETE.

INSULATION BLOCK WALL

IN CASE EXTERNAL WALL SIDE

OPEN TO AIR THEN SHOULD BE

INSULATED

NOTE:

NASS KHARAFI JV

AB

PROJECT:

DRG.TITLE.

AS SHOWN

110236 - AB - ST-01 - 006

VILLA TYPE 1 + 1A

GROUND + FIRST LEVEL

FILL CONCRETE LAYOUT

Consultant:

Client:

FAX:

TELEPHONE:

EMAIL:

+973 1713 1252

+973 1751 0400

[email protected]

Level 11, East Tower

Bahrain World Trade Centre

P.O Box 5668, Manama

Kingdom of Bahrain

MINISTRY OF HOUSING

P.O. BOX 5802,MANAMA,KINGDOM OF BAHRAIN ,TEL:+973 17 533000, FAX: +973 17 533836

KINGDOM OF BAHRAIN

STRATEGIC PROJECTS SECTION

EAST HIDD

HOUSING DEVELOPMENT

CONSTRUCTION & MAINTENANCE OF 483 VILLAS

MANAMA, KINGDOM OF BAHRAIN

A1

Consultant:

P.O. Box 50900, Manama

Kingdom of Bahrain

TEL: +973 17 822666

FAX: +973 17 820666

EMAIL: [email protected]

AS BUILT

SCALE 1 : 50

FIRST FLOOR (TYPE 1+1A)

2

SCALE 1 : 50

C1

C2

W1

C7

W2

W3

C8

C9

GB3

GB1

GB1A

GB2

-0.050 TOB

-0.050 SSL

-0.050 SSL

1 2 3

A

B

C

D

E

F

G

H

NO STRUCTURAL

SLAB

NO STRUCTURAL

SLAB

NO STRUCTURAL

SLAB

(NO COLUMN-C2 FOR

BACK TO BACK OPTION)

-0.050 TOB

-0.050 TOB

250 THK

RAFT SLAB

-0.050 SSL

UP

1:100

MANHOLES

(TYP)

SLO

PE

-0.050 TOB

-0.125 SSL

PLINTH FOR WATER

TANK AND PUMPS

MH

MH

C1

C2

W1

C7

W2

W3

C8

C9

GB3

GB1

GB1A

GB2

-0.050 TOB

-0.050 SSL

-0.050 SSL

1 2 3

A

B

C

D

E

F

G

H

NO STRUCTURAL

SLAB

NO STRUCTURAL

SLAB

NO STRUCTURAL

SLAB

OUTLINE OF COURTYARD WALL

FOR BACK TO BACK OPTION

(TYPE - 1A)

NO COURTYARD WALLS FOR

BACK TO BACK OPTION(TYPE-1)

(NO COLUMN-C2 FOR

BACK TO BACK OPTION)

-0.050 TOB

-0.050 TOB

250 THK

RAFT SLAB

-0.050 SSL

UP

1:100

MANHOLES

(TYP)

SLO

PE

-0.050 TOB

-0.125 SSL

MH

MH

9000

100 3600 5200 100

20000

100

100

2400

3400

2400

3100

3600

3700

1200

1700

9000

100 3600 5200 100

20000

100

100

2400

3400

2400

3100

3600

3700

1200

1800

1100

200

PLINTH FOR WATER

TANK AND PUMPS

1800

1100

200

-0.150 TOB -0.150 TOB

C1

C2

W1

W2

W3

C7

UP

DN

FLB1

FLB5

FLB4

FLB

3

FLB

2

FC

B1

FCB1A

FB1

FB1

FC

B1

FC

B1

FC

B1

FC

B1

FC

B1

FB2

FC

B1B

FC

B1

FC

B1

FCB1A

FC

B1

FC

B1

+3.125 TOH

+3.125 TOH

CANTILEVER RC SLAB

FOR DETAILS REFER TO

SECTION-N1

NO CANTILEVER SLAB

FOR BACK TO BACK

OPTION (TYPE 1)

FC

B1

150 THK.

HCS

150 THK.

HCS

150 THK. HCS

150 THK. HCS

150 THK.

HCS

150 THK.

HCS

150 THK.

HCS

150

THK.

HCS

FB

5

FB3

W2

FC

B1

FC

B1

NON-LOAD

BEARING

BLOCK WALL

ON HCS

FB4

FCB1A

200x400 OPENING

200x900

OPENING

+3.200 TOB

+3.050 TOH

+3.050 TOH

+3.125 SSL

NON-LOAD

BEARING BLOCK

WALL ON HCS

FCB1A

FCB1A

1 2 3

A

B

C

D

E

F

G

H

+3.200 TOB

+3.125 SSL

LB

2

150 THK.

HCS

+4.310 TOC

FOR WINDOW OPENING

IN RC WALL REFER

TO ARCHITECTURAL

DRAWING

C1

C2

W2

DN

RB1

RLB6

RLB5

RLB1

RLB1

RC

B1

RLB

3

RLB

2

RC

B3

RCB1A

RC

B3

RC

B1

RC

B1

RB1

RB

2

RLB4

RC

B1

RC

B1

150 THK.

HCS

150 THK.

HCS

150 THK.

HCS

200 THK.

HCS

150

THK.

HCS

+6.585 SSL

PLINTH FOR MEP

PLANTS (TYP)

150 THK. HCS

150 THK. HCS

RCB1A2

RC

B1B

RC

B2A

+6.325 TOH

+6.325 TOH

RCB2

RCB2

1 2 3

A

B

C

D

E

F

G

H

CANTLEVER SLAB

(NO CANTILEVER SLAB FOR BACK TO

BACK OPTION (TYPE 1) AND PROVIDE

RCB1A INSTEAD OF RB1)

+5.400 TOB

RC

B1

+5.950 SSL

TOP OF COLUMN +6.425

TOP OF COLUMN +6.425

RC

B1

+5.400 TOB

+7.585 TOC

+7.585 TOB

+7.585 TOB

+7.585 TOB

+8.855 TOW

D

E

2 3

5200

2400

TRCB4A

TR

CB

5

TR

CB

3

150 THK. HCS

+9.525 TOH

TRCB4

TRCB1

TR

CB

2

2100

+9.025 TOH

150 THK.PLINTH

FOR WATER TANK

AND PUMPS

1950

290

150 THK.

HCS

+10.785 TOB

9000

100 3600 5200 100

20000

100

100

2400

3400

2400

3100

3600

3700

1200

9000

100 3600 5200 100

20000

100

100

2400

3400

2400

3100

3600

3700

1200

NASS KHARAFI JV

AB

PROJECT:

DRG.TITLE.

AS SHOWN

110236 - AB - ST-01 - 001

VILLA TYPE 1 + 1A

GROUND+FIRST+ROOF+

STAIR ROOF LEVEL GA PLANS

1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES.

NOTES:

Consultant:

Client:

FAX:

TELEPHONE:

EMAIL:

+973 1713 1252

+973 1751 0400

[email protected]

Level 11, East Tower

Bahrain World Trade Centre

P.O Box 5668, Manama

Kingdom of Bahrain

MINISTRY OF HOUSING

P.O. BOX 5802,MANAMA,KINGDOM OF BAHRAIN ,TEL:+973 17 533000, FAX: +973 17 533836

KINGDOM OF BAHRAIN

STRATEGIC PROJECTS SECTION

EAST HIDD

HOUSING DEVELOPMENT

CONSTRUCTION & MAINTENANCE OF 483 VILLAS

MANAMA, KINGDOM OF BAHRAIN

A1

Supervision:

P.O. Box 50900, Manama

Kingdom of Bahrain

TEL: +973 17 822666

FAX: +973 17 820666

EMAIL: [email protected]

AS BUILT

SCALE 1 : 100

GROUND FLOOR PLAN (TYPE 1)

1

SCALE 1 : 100

GROUND FLOOR PLAN (TYPE 1A)

2

NOTE:

ADD 15MM EXTRA(RAFT) FOR SIDES

OF ADJACENT VILLAS ONLY.

SCALE 1 : 100

FIRST FLOOR PLAN (TYPE 1 + 1A)

3

SCALE 1 : 100

ROOF LEVEL PLAN (TYPE 1 + 1A)

4

NOTE:

TOP LEVEL OF BEAMS RLB5, RLB6, RLB1,

RCB1A2 AND RB1 IS +6.425 m.

SCALE 1 : 100

STAIR ROOF PLAN (TYPE 1 + 1A)

5

-0.050 SSL

-0.150 FGL

400

400 150

250

500

3T16

T16-200

T16-200 BW (TOP & BOTTOM)

SECTION

SCALE 1 : 25

V

2

50mm THK.

BLINDING

1 2

-0.050 SSL

3600

RAFT

300

VA

RIE

S

REFER TO STANDARD

DRAWING FOR MANHOLE

STRUCTURAL DETAILS

SECTION

SCALE 1 : 50

A

1

100

50mm THK.

BLINDING

400

1

GB3

-0.050 TOB

-0.150 FFL-0.150 FGL

SECTION

SCALE 1 : 25

C

3

50mm THK.

BLINDING

-0.050 SSL

-0.150 FGL

400

1000 150

250

500

6T16T16-200

T16-200 BW (TOP & BOTTOM)

SECTION

SCALE 1 : 25

W

6

50mm THK.

BLINDING

3

-0.050 TOB

200

200

400

-0.150 FFL

GB1

4T10

T8-200

-0.150 FGL

+1.650 TOB

SECTION

SCALE 1 : 25

D

4

50mm THK.

BLINDING

-0.050 SSL

1400 150

250

150

500

T16-200 BW (TOP & BOTTOM)

8T16T16-200

150

500

SECTION

SCALE 1 : 25

U

5

50mm THK.

BLINDING

200

200

150

(M

IN

)

-0.150 FGL

4T10

T8-200

CONCRETE

INFILL

T8-200

200 x 200

CAPPING BEAM

CONCRETE

INFILL

600

600

T12-200

T10-200

+1.650 TOB

T10-200

2T10

-0.020 TOC

NOTE:

NO EXCAVATION BELOW TOP OF FOOTING WITHOUT

PROVISION OF TEMPORARY WORKS TO SUPPORT

LATERALLY THE WALL. FOOTING TO BE FIRMLY

BACKFILLED

SECTION

SCALE 1 : 40

B

7

50mm THK.

BLINDING

GH

-0.125 SSL

SLOPE

A

-0.050 SSL

-0.150 FGL

400

400

(TYP)

150

SECTION

SCALE 1 : 40

G

8

SECTION

SCALE 1 : 40

N

9

50mm THK.

BLINDING

50mm THK.

BLINDING

FCB1B

150THK. HCS

+3.050 TOH

410

F

150THK. HCS

FCB1A

+3.125 TOH

2

FCB1

+3.125 TOH

150THK. HCS

+3.125 SSL

T10-200 (TYP)

2

FLB2

FLB3

+3.125 TOH

150THK. HCS

2

150THK. HCS

+3.125 TOH

FB5

+3.125 SSL

150THK. HCS

2

150THK. HCS

+3.125 TOH

FCB1

LB2

+3.050 TOH

D

150THK. HCS

FLB4

+3.125 TOH

150910

40

H

+3.125 TOH

FB3

FB2

150THK. HCS

150THK. HCS

+3.050 TOH

200

150

50

+4.310 TOC

50

400

+3.125 TOH

FB1

500

150

T10-200 T&B

T8-200

150THK. HCS

200THK. HCS

RCB3

+6.325 TOH

1T8 (TYP)

T10- 200 (TYP)

100

+7.585 TOB

TYPICAL FOR

ALL CASES

200THK. HCS

RCB3

+6.325 TOH

+7.585 TOB

2T10

4T10

T8- 200

T8

400

300

WALL

PLANTED COLUMN

2

+6.585 SSL

150THK. HCS

RCB2A

+6.325 TOH

2

150THK. HCS

RLB2

RLB3

+6.325 TOH

CONCRETE

(TYP)

+7.585 TOB

2T10

T8-200

CAPPING BEAM

G

RLB4

200THK. HCS

+6.325 TOH

+7.585 TOC

A

150THK. HCS

150

RB1

600

+5.950 SSL

+6.325 TOH

+7.585 TOC

T10-200 T&B

T8-200 T&B

100

+6.325 TOH

+3.200 FFL

±0.000 FFL

+6.325 TOH

+3.200 FFL

±0.000 FFL

RAFT

RAFT

CONCRETE

(TYP)

+7.585 TOC

OUTER GRID

-0.150 FGL-0.150 FGL

+7.585 TOC

100

(T

YP

)

75

(T

YP

)

T8- 200 (TYP.)

2T10 (TYP.)

+3.125 TOH +3.125 TOH

OUTER GRID

G

ROOF

BEAM

+6.325 TOH

+7.585 TOC

T10- 200

4T10

T8- 200

4T10 (PROVIDE DOWELS

FROM ROOF BEAMS)

T8-200

2

TRCB5

150THK. HCS

500

TRCB2

+9.525 TOH

+9.025 TOH

+10.785 TOB

T8-200

2T8

E

TRCB1

+9.025 TOH

150THK. HCS

+7.585 TOB

NASS KHARAFI JV

AB

PROJECT:

DRG.TITLE.

AS SHOWN

110236 - AB - ST-01 - 003

VILLA TYPE 1 + 1A

GROUND+FIRST+ROOF+

STAIR ROOF LEVEL - SECTIONS

1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES.

NOTES:

Consultant:

Client:

FAX:

TELEPHONE:

EMAIL:

+973 1713 1252

+973 1751 0400

[email protected]

Level 11, East Tower

Bahrain World Trade Centre

P.O Box 5668, Manama

Kingdom of Bahrain

MINISTRY OF HOUSING

P.O. BOX 5802,MANAMA,KINGDOM OF BAHRAIN ,TEL:+973 17 533000, FAX: +973 17 533836

KINGDOM OF BAHRAIN

STRATEGIC PROJECTS SECTION

EAST HIDD

HOUSING DEVELOPMENT

CONSTRUCTION & MAINTENANCE OF 483 VILLAS

MANAMA, KINGDOM OF BAHRAIN

A1

Consultant:

P.O. Box 50900, Manama

Kingdom of Bahrain

TEL: +973 17 822666

FAX: +973 17 820666

EMAIL: [email protected]

AS BUILT

SECTION

SCALE 1 : 20

E

12

SECTION

SCALE 1 : 20

H

13

SECTION

SCALE 1 : 20

J

14

SECTION

SCALE 1 : 20

L

16

SECTION

SCALE 1 : 20

M

17

SECTION

SCALE 1 : 20

F

10

SECTION

SCALE 1 : 20

K

15

SECTION

SCALE 1 : 20

G1

11

SECTION

SCALE 1 : 20

N1

18

SECTION

SCALE 1 : 20

P

22

SECTION

SCALE 1 : 20

Q23

SECTION

SCALE 1 : 20

R

21

AT WALL LOCATION AT PLANTED COLUMN LOCATION

SECTION

SCALE 1 : 20

G219

SECTION

SCALE 1 : 20

N220

SCALE 1 : 40

TYPICAL WALL SECTIONS

26

SCALE 1 : 40

TYPICAL RC PARAPET

WALL DETAILS27

SCALE 1 : 40

PARTIAL ELEVATION

27a

SECTION

SCALE 1 : 40

X

27b

SECTION

SCALE 1 : 40

Y

27c

SECTION

SCALE 1 : 40

S

24

SECTION

SCALE 1 : 40

T

25

C1

C2

W1

C7

W2

W3

C8

C9

GB3

GB1

GB1A

GB2

-0.050 TOB

-0.050 SSL

-0.125 S

SL

-0.050 SSL

1 2 3

A

B

C

D

E

F

G

H

NO STRUCTURAL

SLAB

NO STRUCTURAL

SLAB

NO STRUCTURAL

SLAB

(NO COLUMN-C2 FOR BACK

TO BACK OPTION)

-0.050 TOB

-0.050 TOB

250 THK

RAFT SLAB

-0.050 SSL

UP

-0.050 TOB

-0.125 SSL

NO COURTYARD WALLS FOR

BACK TO BACK OPTION(TYPE-1)

MH

MH

GROUND TO

FIRST FLOOR

LEVELS

MARKS

C1 C2 C7 C8 C9

MAIN BARS : 8 T12

LINKS : 2 T8- 200

MAIN BARS : 4 T12 + 2 T10

LINKS : 2 T8- 200

MAIN BARS : 6 T12

LINKS : 2 T8- 200

MAIN BARS : 4 T12

LINKS : T8- 200

2 T10

MAIN BARS : 4 T12 + 2 T10

LINKS : 2 T8- 200

2 T10

BEAM

MARKS

SIZE (mm)

WIDTH DEPTH

200GB1 400

GB2

GB3

200 400

200 400

300GB1A 400

MARKTHICKNESS

W1200

W2200

W3200

SIZE

2000x200

2000x200

1700x200

TOP BAR

BOTTOM BAR

SIDE BAR

LINK

C1

C2

W1

W2

W3

C7

UP

DN

FLB1

FLB5

FLB4

FLB

3

FLB

2

FC

B1

FCB1A

FB1

FB1

FC

B1

FC

B1

FC

B1

FC

B1

FC

B1

FB2

FC

B1B

FC

B1

FC

B1

FCB1A

FC

B1

FC

B1

+3.125 TOH

+3.125 TOH

FC

B1

150 THK.

HCS

150 THK.

HCS

150 THK. HCS

150 THK. HCS

150 THK.

HCS

150 THK.

HCS

150 THK.

HCS

150

THK.

HCS

FB

5

FB3

W2

FC

B1

FC

B1

FB4

FCB1A

+3.200 TOB

+3.050 TOH

+3.050 TOH

+3.125 SSL

FCB1A

FCB1A

1 2 3

A

B

C

D

E

F

G

H

+3.200 TOB

+3.125 SSL

LB

2

150 THK.

HCS

+4.310 TOC

FIRST FLOOR

TO ROOF LVL.

LEVELS

MARKS

C1 C2 C7

MAIN BARS : 8 T12

LINKS : 2 T8- 200

MAIN BARS : 6 T12

LINKS : 2 T8- 200

MAIN BARS : 4 T12

LINKS : T8- 200

BEAM

MARKS

SIZE (mm)

200

WIDTH DEPTH

FB5

FB4

FB3

FB2

FB1

FCB1

FCB1A

FLB1

FLB2

FLB3

FLB4

FLB5

FLB6

FLB6A

200

200

200

200

200

200

200

200

200

200

200

200

200

445

400

600

655

695

275

445

445

275

275

445

445

350

355

FCB1B 200 410

STAIR LANDING GF

STAIR LANDING FF

MARKTHICKNESS

W1200

W2200

W3200

SIZE

2000x200

2000x200

1700x200

C1

C2

W2

DN

RB1

RLB6

RLB5

RLB1

RLB1

RC

B1

RLB

3

RLB

2

RC

B3

RCB1A

RC

B3

RC

B1

RC

B1

RB1

RB

2

RLB4

RC

B1

RC

B1

150 THK.

HCS

150 THK.

HCS

150 THK.

HCS

200 THK.

HCS

150

THK.

HCS

+6.585 SSL

PLINTH FOR MEP

PLANTS (TYP)

150 THK. HCS

150 THK. HCS

RCB1A2

RC

B1B

RC

B2A

OPENING

OPENING

UPSTAND

(TYP)

+6.325 TOH

+6.325 TOH

RCB2

RCB2

1 2 3

A

B

C

D

E

F

G

H

+5.400 TOB

RC

B1

+5.950 SSL

TOP OF COLUMN +6.425

TOP OF COLUMN +6.425

RC

B1

+5.400 TOB

+7.585 TOC

+7.585 TOB

+7.585 TOB

+7.585 TOB

+8.855 TOW

ROOF LVL.

LEVELS

MARKS

C1 C2

MAIN BARS : 4 T12

LINKS : T8- 200

MAIN BARS : 4 T12

LINKS : T8- 200

BEAM

MARKS

SIZE (mm)

WIDTH DEPTH

RB2

RB1

RCB1

RCB1A

RCB2

RCB3

RLB1

RLB2

RLB3

RLB4

RLB5

RLB6

200

200

200

200

200

200

200

200

200

200

200

200

625

510

300

570

730

250

570

300

300

470

570

570

RCB1B

200 510

RCB2A

200 300

RCB1A2

200 570

MARKTHICKNESS

W2200

SIZE

2000x200

SCALE 1 : 100

GROUND FLOOR PLAN (TYPE 1 & 1A)

1

SCHEDULE OF COLUMNS

SCHEDULE OF BEAMS

SCHEDULE OF RC WALLS

TYPICAL SECTION OF BEAM

NASS KHARAFI JV

AB

PROJECT:

DRG.TITLE.

AS SHOWN

110236 - AB - ST-01 - 004

VILLA TYPE 1 + 1A

GROUND+FIRST+ROOF LEVEL

SCHEDULES

1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES.

NOTES:

Consultant:

Client:

FAX:

TELEPHONE:

EMAIL:

+973 1713 1252

+973 1751 0400

[email protected]

Level 11, East Tower

Bahrain World Trade Centre

P.O Box 5668, Manama

Kingdom of Bahrain

MINISTRY OF HOUSING

P.O. BOX 5802,MANAMA,KINGDOM OF BAHRAIN ,TEL:+973 17 533000, FAX: +973 17 533836

KINGDOM OF BAHRAIN

STRATEGIC PROJECTS SECTION

EAST HIDD

HOUSING DEVELOPMENT

CONSTRUCTION & MAINTENANCE OF 483 VILLAS

MANAMA, KINGDOM OF BAHRAIN

A1

Supervision:

P.O. Box 50900, Manama

Kingdom of Bahrain

TEL: +973 17 822666

FAX: +973 17 820666

EMAIL: [email protected]

AS BUILT

SCALE 1 : 100

FIRST FLOOR PLAN (TYPE 1 &1A)

2

SCHEDULE OF COLUMNS

SCHEDULE OF BEAMS

SCHEDULE OF RC WALLS

SCALE 1 : 100

ROOF LEVEL PLAN (TYPE 1 & 1A)

3

SCHEDULE OF COLUMNS

SCHEDULE OF BEAMS

SCHEDULE OF RC WALLS