ARTEL Pellet Thermostove & Stove-Technical Guide
Click here to load reader
-
Upload
siddhartha-sengupta -
Category
Documents
-
view
677 -
download
197
Transcript of ARTEL Pellet Thermostove & Stove-Technical Guide
www.ungarosrl.com
Company Introduction
www.ungarosrl.com
Production facility
www.ungarosrl.com
Research & Development
www.ungarosrl.com
Punching, Laser Cut and Bending
www.ungarosrl.com
Welding
www.ungarosrl.com
• Catena di montaggio
Assembly Lines
www.ungarosrl.com
Testing of Every Single Product
www.ungarosrl.com
Show room & Training room
www.ungarosrl.com
Product Range
www.ungarosrl.com
Ungaro heat devices Ungaro heat devices, operate exclusively with wood pellet fuel and/or wood, they are equipped according to the models with one or two separate combustion chambers. The hearth of the stove is the heat exchanger made on copper which allows to achieve an efficiency over 91%.
Ungaro heat devices have an internal chrono-thermostat to switch the stove on and off automatically (only for wood pellet).
Models Maia, 2-Fire and Yncas produce hot air too, through a fan with a capacity of 60m3/h, heating the ambience where the stove is installed with hot air.
Ungaro heat devices through their copper heat exchanger, may adopt an optional kit for the production of continuous hot drinking water.
www.ungarosrl.com
Ungaro Productsare divided in 2 families
Water Stoves EN 14785
Boilers EN 303-5
www.ungarosrl.com
Water Stoves family 2 - Fire Maia Yncas
www.ungarosrl.com
Water Stoves Maia Classic
Maia 34 Kw 34Maia 24 Kw 24
Maia 14 Kw 14
www.ungarosrl.com
Maia 34 Kw 34Maia 24 Kw 24Maia 14 Kw 14
Water Stoves Maia Style
www.ungarosrl.com
Maia 34 Kw 34Maia 24 Kw 24Maia 14 Kw 14
Water Stoves Maia Design
www.ungarosrl.com
Maia Design with furniture
Living 14 Kw 14 Living 24 Kw 24 Living 34 Kw 34
www.ungarosrl.com
2 fire 34 Kw 342 fire 24 Kw 24
Water Stoves 2-Fire Classic
www.ungarosrl.com
2 fire 34 Kw 342 fire 24 Kw 24
Water Stoves 2-Fire Style
www.ungarosrl.com
Ivory
Ceramic shade proposal
Ochre Leather Bordeaux
www.ungarosrl.com
Noce
Aluminum shade proposal
Walnut Ivory BlackBordeauxCherry
www.ungarosrl.com
Water Stoves Yncas
www.ungarosrl.com
Boilers Family
FIT CTU
CTU PM Box
www.ungarosrl.com
Boilers CTU
CTU24 Kw 24
CTU34 Kw 34
www.ungarosrl.com
FIT 10/14 Kw 10/14
FIT 24 Kw 24
Boilers FIT
www.ungarosrl.com
Boilers CTU PM & Box
www.ungarosrl.com
Main technical sales arguments of Ungaro heat
devices
www.ungarosrl.com
Patent pending
Efficiency over 91%
Easy cleaning for constant performance in time
Ungaro copper heat exchanger & cleaning system
www.ungarosrl.com
www.ungarosrl.com
OFF
30PUL
Maintenance and ordinary cleaning
www.ungarosrl.com
Working modes of Ungaro products The working modes of Ungaro heat devices is divided in the following steps:
Lighting mode (“fan asp” e “load wood”)Stabilizing mode (“fire on”)Working modeModulation modeSwitching off mode
Lighting mode (“fan asp” e “load wood”)
Electronics run a test of about 30 seconds to verify the correct working of the smoke fan (“fan asp”), right after the stove activate pellet gearmotor and ignition (“load wood”). After about 5 minutes the flame will be present.
Stabilizing mode (“fire on”)
Stabilizing of the flame will be on when smoke temperature will meet the value at Pr 13 (40° C as default), only at that moment electronics will disconnect ignition.
www.ungarosrl.com
Working mode
Further of the stabilizing, the stove starts the working mode; at the reaching of the default temperatures will be on the water circulator (water at 40° C) and the ambiance air fan (smoke at 90° C).
Modulation mode
Modulation mode starts at about 9° C below than the SET, the stove will reduce automatically the working speed to reduce fuel.
If modulation is run by an external ambience thermostat, at the reaching of the desired temperature, the stove will reduce automatically to the lowest speed and the display will show “t off”.
Switching off mode
By pressing button “off”, the pellet feeding gearmotor will be disconnected, smoke fan and air fan will run at max speed. All motors will be completely deactivated when smoke temperature will meet the safety value (40° C as default Pr 13).
www.ungarosrl.com
Translated in diagram …
www.ungarosrl.comFan Asp Fire On Load Wood
Temperature
Time
SET (objective)
Modulation start ∆ t 9°C from SET
Suitable working
conditions
Safety default
adjustable Pr 12
How the stove works on PERFECT working conditions
www.ungarosrl.comFan Asp Fire On Load Wood
Temperature
Time
SET (objective)
Modulation start ∆ t 9°C from SET
Re-start ∆t 3°C from SET
Suitable working
conditions
Working mode
Working mode
H2O modeAdjust. Pr 23
Stop Fire mode
Safety default adjustable Pr 12
How the stove works if it’s OVER-SIZED than System
www.ungarosrl.comFan Asp Fire On Load Wood
Temperature
Time
SET (objective)
Modulation start ∆ t 9°C < SET
Re-start ∆t 3°C < SET
Suitable working
conditions
Working mode
Working mode
H2O modeAdjust. Pr 23
Stop Fire mode
How the stove works if it’s VERY OVER-SIZED than System
Stop Fire mode starts
earlier
Safety default adjustable Pr 12
www.ungarosrl.comFan Asp Fire On Load Wood
Temperature
Time
SET (objective)
Modulation start ∆ t 9°C < SET
Suitable working
conditions
How the stove works if it’s DOWN-SIZED than System
Safety default adjustable Pr 12
www.ungarosrl.com
Connection to water tank (Puffer Mode)
WATER TANK (PUFFER)
Well for temperature detection
Air thermostat
Electric connection
In “puffer mode” stove will work as follows: Modulation will start according to water temperature inside water tank. It will enter on “stop fire” mode following the set of key 22 (pr 84).
It will turn on again, exit from “stop fire” following the set of key 23 (pr 85)
Despite the stove is in “On” or “Off” mode, water circulator will stop when temperature of the water in the stove will be 2° C higher of the set required on water tank. It will start again circulation when temperature will be 4° C higher than the set required. Hot air (where present), will take as reference to turn on the temperature of smoke (Pr-11), its speed will depend on the speed of the stove (Po 1 to Po9). The speed of hot air may also be adjust with Pr 25-26-27.
www.ungarosrl.comFan Asp Fire On Load Wood
Temperature
Time
SET+ ( 2°…15°C) Key 22 Pr 84
Modulation start ∆ t 9°C < SET
Re- start ∆t 3°C < SET+ ( 2°…15° C) Key 23 Pr 85
Suitable working
conditions
Working mode
Working mode
Stop Fire mode
How the stove works in PUFFER MODE
Safety default adjustable Pr 12
www.ungarosrl.com
What is there inside?
www.ungarosrl.com
Water Stoves Norm “EN 14785”
Copper heat exchanger Efficiency over 91% Easy cleaning and maintenance of the
exchanger Hot air fan Production of continuous hot drinking water Certification EN 14785
MAIA Models
www.ungarosrl.com
Serie Maia• Display
• Hot air fan
• Pressure transducer
• Electronic board
• Depressor
• Expansion vase
• Air vent valve
• Water circulator
• Safety valve
• Ignition
• Smoke fan
• Hot drinking water production unit
• Pellet feeding gearmotor
• Electric clamp
• Safety thermostats
• Main switch
www.ungarosrl.com
Copper heat exchanger Water fire place most powerful of the
market Efficiency over 91% Easy cleaning and maintenance of the
exchanger Hot air fan Production of continuous hot drinking water Frontal chimney inspection (patented) Double pan ash drawer (patented) Certification EN 14785
Water Stoves Norm “EN 14785”
YNCAS Models
www.ungarosrl.com
YNCAS Models
Double pan ash drawer (patented) Frontal chimney inspection (patented)
www.ungarosrl.com
YNCAS Models• Display
• Hot air fan
• Pressure transducer
• Electronic board
• Depressor
• Expansion vase
• Air vent valve
• Water circulator
• Safety valve
• Ignition
• Smoke fan
• Hot drinking water production unit
• Pellet feeding gearmotor
• Electric clamp
• Safety thermostats
• Main switch
www.ungarosrl.com
How to remove side panels from Yncas models
1. Disconnect power supply
2. Disassemble the lower frame to access the tightening screws
3. Unscrew the tightening screws
4. Extract the stove till the end of stroke
5. Remove panels unscrewing side screws
6. Perform maintenance and repair
N.B. tutte le operazioni di manutenzione vanno effettuate a stufa fredda e priva di alimentazione elettrica
Remark : All maintenance operation must be carried out at cold stove and with no power supply
www.ungarosrl.com
Double copper heat exchanger (on 34 kw model)
Double combustion chamber Double fuel feeding pellet and wood Double certification: Pellet EN 14785 Wood EN 13240 Installation close circuit for wood Efficiency over 91% Easy cleaning and maintenance of the
exchangers Hot air fan Production of continuous hot drinking water Double pan ash drawer (patented)
Water Stoves Norms “EN 14785” (pellet)
“ EN 13240” (wood) 2-FIRE Models
www.ungarosrl.com
2-FIRE Models
Wood
Pellet
www.ungarosrl.com
Serie 2-FIRE• Display
• Hot air fan
• Electronic board
• Depressor
• Air vent valve
• Pressure transducer
• Ignition
• Safety valve
• Smoke fan
• Water circulator
• Hot drinking water production unit
• Pellet gearmotor
• Safety thermostats
• Main switch
• Expansion vase
• Inlet valve primary air (wood)
• Safety discharging valve
• Automatic filling valve
www.ungarosrl.com
Larger copper heat exchanger to increase efficiency to the water
Efficiency over 91% Easy cleaning and maintenance of the
exchanger Production of continuous hot drinking
water Certification EN 303-5
In PM version: Automatic cleaning of the fire pot External pellet tank Long working autonomy and very low
cleaning operation
Boilers Norm “EN 303-5” CTU Models
www.ungarosrl.com
CTU Models• Display
• Pressure transducer
• Electronic board
• Depressor
• Expansion vase
• Air vent valve
• Water circulator
• Safety valve
• Ignition
• Smoke fan
• Hot drinking water production unit
• Pellet gearmotor
• Electric clamp
• Safety thermostats
• Main switch
2008/09 2009/10
www.ungarosrl.com
CTU PM Models• Display
• Display PM BOX
• Pressure transducer
• Electronic board
• Depressor
• Expansion vase
• Air vent valve
• Water circulator
• Safety valve
• Ignition
• Smoke fan
• Hot drinking water production unit
• Pellet gearmotor
• Electric clamp
• Safety thermostats
• Main switch
• Pellet presence sensors
• PM BOX electronic board
• Fire pot cleaning gearmotor
• PM BOX main switch
www.ungarosrl.com
CTU PM cleaning system
ONOFF
Fire pot upper part
Fire pot
Cleaning grill
Ash drawer
www.ungarosrl.com
PM BOX
www.ungarosrl.com
Copper heat exchanger Efficiency over 91% Easy cleaning and maintenance of the
exchanger Production of continuous hot drinking
water Double ignition Option of installing outside the house Install close to wall Lateral smoke exit Certification EN 303-5
FIT ModelsBoilers Norm “EN 303-5”
www.ungarosrl.com
FIT Models• Display
• Pressure transducer
• Electronic board
• Depressor
• Expansion vase
• Air vent valve
• Water circulator
• Safety valve
• Ignitions ( 2 )
• Smoke fan
• Hot drinking water production unit
• Pellet gearmotor
• Electric clamp
• Safety thermostats
• Main switch
www.ungarosrl.com
Display symbol description
It’s on when the mode of hot drinkig water is activate.
It’s on when stove is operatig on conventional mode.
It’s on when the air fan is operating.
It’s on when the water circulator is operating.
It’s on when the smoke fan is operating.It’s on when display receives the remote control signal.
It’s on when an external ambience thermostat is not connected. Blinking when an external ambience thermostat is connected.
It’s on during the time the pellet feeding gearmotor is operating.It’s on when electric ignition is activate.
It’s on when automatic switch on/off is operating.
www.ungarosrl.com
When smoke temperature will reach 41° C, display will show “Fire ON” (remaining in this phase for several minutes allowing the flame to stabilize itself ).
At this point the upper display will show the working speed that must be set at 9 (max) using button 6 during first working hours. The lower display will show the outlet water temperature that must be set at 65°C by pressing only once button 3-“SET” and increasing or decreasing water temperature through buttons 2 and 1.
Display messages at switch on
Press button 4 until the display will show “FAN ASP”, at this stage the stove will perform a diagnosis on the smoke fan (about 30 seconds).
Right further display will show “LOAD WOOD”, cochlea will start moving feeding pellet and electric ignition will be on.
Only for 2-Fire Models.
When we would like to switch on only the wood combustion chamber, the upper display will show “OFF”, the lower will show the outlet water temperature. The temperature of the outlet water is electronically controlled by the opening and closing of the primary air inlet valve. The offset can be set from 0° to 20° C.The wood can be light only manually as a conventional wood stove. The hot air will not be operating, the option is valid only with pellet combustion chamber on.
www.ungarosrl.com
Display messages
To check water pressure inside the stove press button P2. The upper display will show the pressure in Bar.
Stove has an automatic cleaning system self-activating. Range and duration can be set. When the cleaning mode will be activate the display will show “PUL FIRE”, little later stove will return on working mode.
www.ungarosrl.com
Troubleshooting part wise
www.ungarosrl.com
Black-out
In event of black-outs, stove is protected by 2 fuses located at the rear.
FUSES
www.ungarosrl.com
Black-out If black-out will be shorter that 1 minute, stove will not go on
alarm “NO RETE”;
If black-out will be longer than 1 minute, stove will stop feeding pellet and will go to alarm “NO RETE”; stove could be switch on again only after the cooling, by first cleaning the cast iron fire pot, than manual start pressing button P4.
www.ungarosrl.com
Gearmotor
Gearmotor feeds stove with wood pellet.
www.ungarosrl.com
What are the events showing the inappropriate working of the gearmotor ? stove does not turn on. stove suddenly turns off. quantity of wood pellet is wrong
Over-loading (too much pellet on the fire pot) Lacks of pellet on the fire pot.
What are the main causes of breakage? extremely hard wood pellet. different fuel from wood pellet. external parts on the fuel tank blocking the gearmotor (nuts, nails, etc. ). defective part, wear.
www.ungarosrl.com
What is going on if the gear motor does not work ?
Wood pellet does not fall in the fire pot. The stove does not start. Leakage of power. Most common alarm shown on display “PUL BRAC – NO WOOD”.
www.ungarosrl.com
How to replace a gearmotor.
1. Disconnect power supply
2. Disassemble the rear panel
3. Unscrew the fixing screw as shown
4. Disconnect wiring
5. Remove gearmotor
6. Replace new gearmotor and fix screw
Remark : All maintenance operation must be carried out at cold stove and with no power supply
www.ungarosrl.com
Smoke fan
Smoke fan generates depression in the combustion chamber, forcing the emission of
the smokes.
www.ungarosrl.com
What is going on if the smoke fan does not work? Accumulation of smoke in the combustion chamber. Alarm shown on the display : “NO DEP”.
What are the main causes of breakage?
Tension swings. Power cable broken or damaged. Defective part, wear.
www.ungarosrl.com
What are the events showing the inappropriate working of the smoke fan ?
The stove does not turn on. Accumulation of smoke in the combustion chamber. Accumulation of wood pellet in the fire pot. The stove has a defective combustion.
www.ungarosrl.com
How to replace a smoke fan.
1. Disconnect power supply
2. Disassemble the rear and the sides panels
3. Unscrew the 4 fixing screws as shown
4. Disconnect wiring
5. Remove and replace new smoke fan
N.B. tutte le operazioni di manutenzione vanno effettuate a stufa fredda e priva di alimentazione elettrica
Remark : All maintenance operation must be carried out at cold stove and with no power supply
www.ungarosrl.com
Air Fan
The air fan blows hot air in the ambience where the stove is installed.
www.ungarosrl.com
What is going on if the air fan does not work? The stove does not blow hot air
What are the main causes of breakage? Tension swings. Power cable broken or damaged. Defective part, wear.
www.ungarosrl.com
What are the events showing the inappropriate working of the smoke fan? Bad smell. Leakage of power.
www.ungarosrl.com
How to replace a smoke fan
1. Disconnect power supply
2. Disassemble side panels
3. Unscrew the 5 screws as shown
4. Disconnect wiring
5. Remove and replace new air fan
N.B. tutte le operazioni di manutenzione vanno effettuate a stufa fredda e priva di alimentazione elettrica
Remark : All maintenance operation must be carried out at cold stove and with no power supply
www.ungarosrl.com
Electronic ignition
Electronic ignition lights pellet in the fire pot.
www.ungarosrl.com
What is going on if the electronic ignition does not work? The stove does not turn on. Alarm most shown on display “NO WOOD – PUL BRAC”.
What are the main causes of breakage? Tension swings. Power cable broken or damaged. Defective part, wear.
www.ungarosrl.com
What are the events showing the inappropriate working of the ignition? The stove doesn’t turn on, or it turns on in a longer time. The stove turn on, but with a lot of smoke on combustion chamber. Leakage of power.
Ignition working 100%.
Ignition not working properly.
www.ungarosrl.com
How to replace the electronic ignition1. Disconnect power supply
2. Disassemble rear and side panels
3. Disconnect ignition from mother board
4. Remove gearmotor as shown
5. Unscrew ignition as shown
6. Remove and replace new ignition
N.B. tutte le operazioni di manutenzione vanno effettuate a stufa fredda e priva di alimentazione elettrica
Remark : All maintenance operation must be carried out at cold stove and with no power supply
www.ungarosrl.com
Depressor
Depressor is a safety device checking the right depression on the outlet of the smoke
www.ungarosrl.com
What is going on if the depressor does not work?
The stove doesn’t turn on. No power to the wood pellet gearmotor. Alarm most shown on the display: “NO DEP”
What are the main causes of breakage? Defective part, wear.
www.ungarosrl.com
What are the events showing the inappropriate working of the depressor?
Alarm on the display: “NO DEP”.
www.ungarosrl.com
How to adjust the combustion air Turn on the stove and make it run at max speed for 30 min. avoiding to enter on modulation mode. On old models not provided of entry for adjusting, disassemble the left panel. Disconnect the transparent sylicon tube and connect it to the mesurer, disconnect the red wire from pin 2(NO) and connect it to pin 1(NC).
www.ungarosrl.com
Default set for the combustion draft
Speed shown on display Speed on parametersSpeed 1 (Po 1) Speed 1 (Pr 18)Speed 3 (Po 3) Speed 2 (Pr 19)Speed 5 (Po 5) Speed 3 (Pr 20)Speed 7 (Po 7) Speed 4 (Pr 21)Speed 9 (Po 9) Speed 5 (Pr 22)
14 Kw ModelsWorking Mode Draft in Pascal
Load wood (Pr 16) 100 paFire On (Pr 17) 60 paSpeed 1 (Po 1) (Pr 18) 35 ÷ 40 paSpeed 2 (Po 3) (Pr 19) 40 ÷ 45 paSpeed 3 (Po 5) (Pr 20) 50 ÷ 55 paSpeed 4 (Po 7) (Pr 21) 60 ÷ 65 paSpeed 5 (Po 9) (Pr 22) 70 ÷ 80 pa
www.ungarosrl.com
24 Kw ModelsWorking Mode Draft in Pascal
Load wood (Pr 16) 100 paFire On (Pr 17) 60 paSpeed 1 (Po 1) (Pr 18) 35 ÷ 40 paSpeed 2 (Po 3) (Pr 19) 40 ÷ 45 paSpeed 3 (Po 5) (Pr 20) 50 ÷ 55 paSpeed 4 (Po 7) (Pr 21) 60 ÷ 65 paSpeed 5 (Po 9) (Pr 22) 70 ÷ 80 pa
34 Kw ModelsWorking Mode Draft in Pascal
Load wood (Pr 16) 100 paFire On (Pr 17) 70 paSpeed 1 (Po 1) (Pr 18) 35 ÷ 40 paSpeed 2 (Po 3) (Pr 19) 40 ÷ 45 paSpeed 3 (Po 5) (Pr 20) 50 ÷ 55 paSpeed 4 (Po 7) (Pr 21) 65 ÷ 70 paSpeed 5 (Po 9) (Pr 22) 75 ÷ 80 pa
Default set for the combustion draft
www.ungarosrl.com
Display and Remote display
Display is the interface between user and stove.
Remote display is available as option.
www.ungarosrl.com
PM BOX display
Complementary display to controlPM BOX
www.ungarosrl.com
P1P3 P4
P6
P2 P5
P4 button is used to turn on and off the automatic pellet feeding.
P1 & P2 buttons are used to increase or decrease loading time; or to change values on the menu parameters.
P5 & P6 are used to choose different menus.
P3 is used to enter on the main menu.
It’s on when automatic pellet feeding is activated.
No effect.
It’s on when pellet tank is loaded.
No effect.
It’s on when the maximum load on the stove has been overtaken.
No effect.
It’s off when stove tank is at minimum load.
www.ungarosrl.com
spento
▌ ▌ ▌
Automatic daily feeding program ON
▌
Automatic week-end feeding program ON
Automatic weekly feeding program ON
Automatic feeding program ON
www.ungarosrl.com
Electronic boardElectronic board controls any part of the stove.
www.ungarosrl.com
What is going on if the electronic board does not work? stove does not turn on. continuous pellet feeding with stove in off mode. display off with fuses ok. unidentified failures of different parts without specific alarm. smoke fan always on. hot air fan always on, or not properly working.
What are the main causes of breakage? Tension swings. Failure of an electronic part run by the board. Not appropriate Mass or house electrical system not in order
www.ungarosrl.com
What are the events showing the inappropriate working of the electronic board?
display out of order. stove does not react. stove does not turn on automatic mode. continuous pellet feeding with stove in off mode. hot air fan always on, or not properly working. smoke fan always on.
www.ungarosrl.com
www.ungarosrl.com
BICO - ARIA
www.ungarosrl.com
BICO - ARIA
2-fire
www.ungarosrl.com
Scheda Elettronica BOX
www.ungarosrl.com
Smoke Sensor
The smoke sensor is positioned on correspondence of the outlet of the smoke. It detects if the stove is switched on & off.
www.ungarosrl.com
What is going on if the smoke sensor does not work? The stove does not turn on. The smoke fun is always on. Alarm shown on the display “SOND FUMI”. Alarm shown on the display “PUL BRAC – NO FIRE” (when the stove is working). Alarm shown on the display “NO WOOD” (in starting mode).
What are the main causes of breakage? power cable broken or damaged. defective part, wear.
www.ungarosrl.com
What are the events showing the inappropriate working of the smoke sensor? The stove detects a defective temperature of the smoke. The stove does not turn on ( min. temperature of smoke to switch on is 41° C) Depending to the false temperature detected the stove may have:
Absence of hot air Continuous blowing of air (even cold air)
Remark: Any time smoke sensor might be replace, always consider polarity at connecting.
www.ungarosrl.com
Water Sensor
The water sensor detects the outlet temperature of the water, it provides to start
modulation and safety to avoid over temperature.
www.ungarosrl.com
What is going on if the water sensor does not work? The stove has an abnormal consume of fuel. The stove does not modulate. Water gets to over temperature. Possible alarms shown: ”SOND H2O”, “HOT H2O”, “SIC OFF”. In some cases could be present also alarm “PRESS H2O”.
What are the main causes of breakage? power cable broken or damaged. defective part, wear.
www.ungarosrl.com
What are the events showing the inappropriate working of the water sensor? The stove works at maximum speed, even if set temperature has been reached. The stove reacts as the temperature continuously changes. Leakage of power due to damaged wiring ( temperature blinking on the display). Display often shows alarms: “SOND H2O” or “HOT H2O”.
www.ungarosrl.com
Ambience SensorThe ambience sensor detects
temperature in the ambience where the stove is installed.
It switches on & off the air fan.If connected to water tank controls
modulation of the stove.
www.ungarosrl.com
What is going on if the air sensor does not work?
Air blowing may not be active when it should. Air temperature blinking on the display. Water circulator always on, even when stove is off (the stove has an “ice protection”, when ambience temperature is lower than 7 ° C, circulator is always working). What are the main causes of breakage? power cable broken or damaged.
www.ungarosrl.com
What are the events showing the inappropriate working of the air sensor?
The stove does not start air fan. The stove detects a wrong ambience temperature. Smoke fan is always on. Circulator is always on (“ice protection” with temperature lower than 7° C ).
www.ungarosrl.com
Circulator Mono-phase
Circulator leads hot water in the house system.
www.ungarosrl.com
What is going on if the circulator does not work?
Hot water in the stove and possible over temperature. System cold. Display shows alarms: “SIC OFF” or “HOT H2O”
What are the main causes of breakage? Presence of limestone due to a long time of not working. Leakage of power.
Remark : We recommend to do not disconnect power to the plug, even when stove is not used (holidays or summer). If the stove is plugged in, circulator will run from time to time to avoid limestone sediment.
www.ungarosrl.com
What are the events showing the inappropriate working of the circulator? High temperature of the water in stove. Hot water missing on the system.
Remark: After a long time of not use circulator may be block. If necessary make it run manually through the screw at the back of the circulator itself.
www.ungarosrl.com
Pressure transducer
It controls electronically the pressure of water in the stove included from 0,3 – 2,0 bar.
www.ungarosrl.com
What is going on if the transducer does not work?
Wrong reading of the pressure in the stove. Display shows alarm: “PRESS H2O”.
What are the main causes of breakage? Too high pressure in the stove during first filling of water in the system. Leakage, or wrong power at the heads of the transducer due to a malfunctioning of the electronic board.
www.ungarosrl.com
What are the events showing the inappropriate working of the transducer?
Tension lower than 5V at the heads of the transducer (possible malfunctioning of the electronic board). The pressure detected on the display is not constant and keeps changing. The pressure detected is different to the one shown by other measurers.
www.ungarosrl.com
Safety thermostat pellet
It’s a safety thermostat detecting temperature of pellet tank.
www.ungarosrl.com
What is going on if the safety thermostat does not work?
The stove doesn’t turn on. Display shows alarm: “HOT PELL”. Gearmotor for pellet feeding has no power.
What are the main causes of breakage? Broken or damaged capillary. Excessive strains (often activated reset).
www.ungarosrl.com
What are the events showing the inappropriate working of the thermostat?
Leakage of power, and consequent blinking of the display. No power at the gearmotor for pellet feeding.
www.ungarosrl.com
Safety thermostat water
It’s a safety thermostat detecting temperature of water inside the
stove.
www.ungarosrl.com
What is going on if the safety thermostat does not work?
The stove doesn’t turn on. Display shows alarm: “HOT H2O”. Gearmotor for pellet feeding has no power.
What are the main causes of breakage? Broken or damaged capillary. Excessive strains (often activated reset).
www.ungarosrl.com
What are the events showing the inappropriate working of the thermostat? Leakage of power, and consequent blinking of the display. No power at the gearmotor for pellet feeding.
www.ungarosrl.com
Primary air valve
It’s present only on 2-Fire models, for wood combustion chamber. It opens and closes making the combustion of wood modulate.
www.ungarosrl.com
What is going on if the air valve does not work?
Impossible to light wood. No air for combustion available.
What are the main causes of breakage ? Power cable broken or damaged. Leakage of power. Tension transformer 220 – 24 Volt not working.
www.ungarosrl.com
What are the events showing the inappropriate working of the air valve? Impossible to light wood. No modulation of the wood combustion chamber.
Remark. Insert low quantity of wood if water temperature is close to the set.Lighting wood chamber when water is already on temperature due to previous pellet burning, the valve is almost closed.
www.ungarosrl.com
Fast discharging safety valve
It detects temperature of water inside the stove.It is present only on 2-fire models.
www.ungarosrl.com
What is going on if the safety discharging valve does not work?
Temperature of the water can go over 110° C. Safety pressure bar ( 3 bar) opens.
What are the main causes of breakage ? Broken or damaged capillary.
www.ungarosrl.com
What are the events showing the inappropriate working of the safety discharging valve? Continuous opening of safety pressure valve (3 bar).
www.ungarosrl.com
Air vent valve
The air present in the stove and in the system automatically goes out through the air vent valve.
www.ungarosrl.com
What is going on if the vent valve does not work? The stove can go on over temperature. Display shows alarm: “ SIC OFF”.
Ex. High temperature of the stove, water outlet pipe cold, circulator blocked by the air inside stove or system.
What are the main causes of breakage? Presence of limestone due to a long time of not working.
www.ungarosrl.com
What are the events showing the inappropriate working of the air vent valve?
Over temperature of the water in the stove. High “bubble” noise during circulation of hot water.
www.ungarosrl.com
Automatic filling safety valve
It’s present only on 2-fire models.The filling valve keeps constant the
pressure in the stove.
www.ungarosrl.com
What is going on if the filling valve does not work?
Display shows alarm: “PRESS H2O”.
What are the main causes of breakage? Presence of limestone due to a long time of not working.
www.ungarosrl.com
What are the events showing the inappropriate working of the air filling valve? Improper measurement of the valve. Gradual loss of temperature of the heating elements.
www.ungarosrl.com
Expansion Vase
It’s a tank used to compensate the variation of the volume of the water due to the rise of the temperature.
www.ungarosrl.com
What is going on if the expansion vase does not work?
It’s impossible to compensate the rise of the volume of the water. Most shown alarm on the display: ”PRESS H20”.
What are the main causes of breakage? Presence of limestone due to a long time of not working.
www.ungarosrl.com
What are the events showing the inappropriate working of the air expansion vase? The possible loss of water. Unusual rise of the pressure inside the stove.
www.ungarosrl.com
Pocket Troubleshooting
www.ungarosrl.com
Pocket TroubleshootingDisplay
D1Display D2 Nature of the problem What to do
ALARM SOND H2O Defective water sensorWater sensor without power
Connect a new water sensor to the electronic board and make sure alarm should be off. If alarm is still on, check electronic board.
ALARM HOT TEMP Smoke temperature is higher than 280° C Check temperature at cold stove. Connect a new smoke sensor and make sure temperature is not equals to previous one. If it’s so, replace electronic board.
ALARM SOND FUMI Defective smoke sensorSmoke sensor is not connected to electronic board.
Check temperature at cold stove. Connect a new smoke sensor and make sure temperature is not equals to previous one. If it’s so, replace electronic board.
www.ungarosrl.com
Display D1
Display D2
Nature of the problem What to do
ALARM NO FIRE Impossible to turn on the stoveLacks of pellet on the tankWater on over temperature
Check ignition, and if it’s the case replace it. Check also proper working of smoke sensor.
ALARM NO WOOD
Lacks of pellet on the tankWear electronic ignitionGearmotor blocked or defective
Check proper working of gearmotor, ignition and smoke sensor.
ALARM NO DEP Ash drawer openChimney dirty or blockedDefective depressorWater on over temperature
Check smoke fan, tubes and chimney. Rare check depressor as last.
ALARM HOT PELL Hot temperature of the pellet tank Check pellet tank and reset safety thermostat at the back of the stove.
www.ungarosrl.com
Display D1 Display D2 Nature of the problem What to do
ALARM PUL BRACNO FIRE
Over load of pellet in fire potFire pot not well positioned Fail switch on
Check fire pot position.Check proper working of ignition and smoke sensor. Adjust speed of smoke fan to perfect combustion.
ALARM NO RETE Black out or no power supply for longer than 1 minuteSwitch off of the stove through the rear main switch
Reset electronic board as follows: press “set” to “ut 04”, than “ f 1” and confirm pressing “set” button. Press once the “on/off” button and than keep it press for 2 seconds.
ALARM PRESS H2O High pressure in the stoveLow pressure in the stove
Check pressure on the display by pressing button 2, eventually check pressure on external measurer. If there is difference between external measurer and value on the display, replace pressure transducer. Check hot drinking water group if present, with closed circuit pressure must be constant.
www.ungarosrl.com
Display D1 Display D2 Nature of the problem What to do
ALARM SIC OFF High temperature of the waterBlocked circulator
The stove is on over temperature. Reset safety thermostat at the back. Check circulator, if blocked manually restart it. Check system to be sure there is no closing of the circuit. Check the display, led with the sun shouldn’t be on or blinking. If alarm is still present replace safty thermostat.
ALARM HOT H2O Over temperature of the water in the stoveCirculator blocked
If the alarm is shown at cold stove, check water sensor and the connection to the electronic board. If alarm is shown after over temperature refer to “ SIC OFF ” alarm.
www.ungarosrl.com
The End