AQUIND INTERCONNECTOR · and Floor Plans Option A Sheet 3 of 4 EN020022-2.10-EL-Sheet4 Application...
Transcript of AQUIND INTERCONNECTOR · and Floor Plans Option A Sheet 3 of 4 EN020022-2.10-EL-Sheet4 Application...
AQUIND Limited
AQUIND Limited
AQUIND INTERCONNECTOR
Indicative Optical Regeneration Station(s)
Elevations and Floor Plans
The Planning Act 2008
The Infrastructure Planning (Applications: Prescribed Forms and Procedure) Regulations
2009 – Regulation 5(2)(o)
Document Ref: 2.10
PINS Ref.: EN020022
AQUIND Limited
AQUIND INTERCONNECTOR
Indicative Optical Regeneration Station(s)
Elevations and Floor Plans
AQUIND Limited
PINS REF.: EN020022
DOCUMENT: 2.10
DATE: 14 NOVEMBER 2019
WSP
WSP House
70 Chancery Lane
London
WC2A 1AF
+44 20 7314 5000
www.wsp.com
CONTENTS
EN020022-2.10-EL-Sheet1
Application document reference 2.10 Indicative Optical Regeneration Station(s) Elevations
and Floor Plans Sheet 1 of 4
EN020022-2.10-EL-Sheet2 Application document reference 2.10 Indicative Optical Regeneration Station(s) Elevations
and Floor Plans Sheet 2 of 4
EN020022-2.10-EL-Sheet3 Application document reference 2.10 Indicative Optical Regeneration Station(s) Elevations
and Floor Plans Option A Sheet 3 of 4
EN020022-2.10-EL-Sheet4 Application document reference 2.10 Indicative Optical Regeneration Station(s) Elevations
and Floor Plans Option B Sheet 4 of 4
XX
XX
XX
XX
XX
XX
XX
XX
X
X
X
X
X
X
1.30 m x 4.09 m
DIESEL
GENERATOR
HVACHVAC
XX
XX
XX
XX
XX
XX
XX
XX
X
X
X
X
X
X
1.30 m x 4.09 m
DIESEL
GENERATOR
HVACHVAC
PARKING
SPACE 1
PARKING
SPACE 2
5 m
2 m
10.4 m10m
FUEL
STORAGE
2 m
2 m
FUEL
STORAGE
2 m
2 m
ACCESS ACCESSACCESS ACCESS
AC
CE
SS
AC
CE
SS
2.5
m
FIRST AID KIT AND
EMERGENCY EYE
WASH STATION
FIRE EXTINGUISHER
COMM BOARD
POWER PLANT
INTEGRATED
LOAD CENTER
AUTOMATIC
TRANSFER SWITCH
OPEN AIR
GENERATOR
ENCLOSURE
FIBRE
DISTRIBUTION
PANEL
(F
RO
NT
)
(F
RO
NT
)
(F
RO
NT
)
(F
RO
NT
)
(F
RO
NT
)
DUCTED
FIBRE OPTIC CABLE
6.9
0 m
2
.
3
5
m
2
.
3
5
m
1.3
0 m
4.09 m
3.2
5 m
3.6
5 m
35 m
18
m
8 m
8 m
6.17 m
9.1
0 m
2 m
APPROVED:
PROJECT No:
SCALE AT A1:
TITLE:
PROJECT:
DRAWING No:
DESIGNED:
CHECKED:
DATE:
REV:
CLIENT:
DRAWING STATUS:
DRAWN:
01
29/10/2019
ILLUSTRATIVE
J Crouch
EN020022 A LeniaA Lenia
J Crouch1:75
EN020022-2.10-EL-Sheet1
AQUIND Interconnector
Application document reference 2.10
Indicative Optical Regeneration Station(s)
Elevations and Floor Plans
Sheet 1 of 4
2019 BURNS & McDONNELL EUROPE (UK) Limited
c
N
1 : 75
1
Optical Regeneration Station(s) Compound Plan View
Infrastructure Planning (Applications: Prescribed
Forms and Procedure) Regulations 2009 - Regulation 5(2)(o)
5 m
FUEL
STORAGE
FUEL
STORAGE
FUEL
STORAGE
2.35 m
1.9
m
0.9
5 m
HVACHVACHVACHVAC
2.8
m
1.07 m
2.1
5 m
0.9
5 m
1.9 m
10.4 m
Lower Roof
3.7 m
Upper Roof
3.72 m
Upper Roof
3.72 m
Upper Roof
3.72 m
Lower Roof
3.7 m
Upper Roof
3.72 m
Level 0
0
Level 0
0
Level 0
0
Level 0
0
Lower Roof
3.7 m
2.4
5 m
10 m
6.90 m
6.90 m0.57 m
0.57 m
0.9
5 m
8 m
8 m
APPROVED:
PROJECT No:
SCALE AT A1:
TITLE:
PROJECT:
DRAWING No:
DESIGNED:
CHECKED:
DATE:
REV:
CLIENT:
DRAWING STATUS:
DRAWN:
01
28/10/2019
ILLUSTRATIVE
J Crouch
EN020022 A LeniaA Lenia
J Crouch1:75
EN020022-2.10-EL-Sheet2
AQUIND Interconnector
Application document reference 2.10
Indicative Optical Regeneration Station(s)
Elevations and Floor Plans
Sheet 2 of 4
2019 BURNS & McDONNELL EUROPE (UK) Limited
c
1 : 75
1
Optical Regeneration Station(s) Compound Elevation View
Infrastructure Planning (Applications: Prescribed
Forms and Procedure) Regulations 2009 - Regulation 5(2)(o)
1
.
3
0
m
x
4
.
0
9
m
D
I
E
S
E
L
G
E
N
E
R
A
T
O
R
H
V
A
C
H
V
A
C
1
.
3
0
m
x
4
.
0
9
m
D
I
E
S
E
L
G
E
N
E
R
A
T
O
R
H
V
A
C
H
V
A
C
P
A
R
K
I
N
G
S
P
A
C
E
1
P
A
R
K
I
N
G
S
P
A
C
E
2
F
U
E
L
S
T
O
R
A
G
E
F
U
E
L
S
T
O
R
A
G
E
8 m
8 m
F
o
r
t
C
u
m
b
e
r
l
a
n
d
R
d
FortCumberland Rd
M
e
l
v
i
l
l
e
R
d
L
u
m
s
d
e
n
R
d
APPROVED:
PROJECT No:
SCALE AT A1:
TITLE:
PROJECT:
DRAWING No:
DESIGNED:
CHECKED:
DATE:
REV:
CLIENT:
DRAWING STATUS:
DRAWN:
01
28/10/2019
ILLUSTRATIVE
J Crouch
EN020022 A LeniaA Lenia
J Crouch1:250
EN020022-2.10-EL-Sheet3
AQUIND Interconnector
Application document reference 2.10
Indicative Optical Regeneration Station(s)
Elevations and Floor Plans
Option A
Sheet 3 of 4
2019 BURNS & McDONNELL EUROPE (UK) Limited
c
1 : 250
1
Optical Regeneration Station(s) Compound Plan View
N
LEGEND KEY
ORDER LIMITS
Infrastructure Planning (Applications: Prescribed
Forms and Procedure) Regulations 2009 - Regulation 5(2)(o)
C
A
R
P
A
R
K
1
C
A
R
P
A
R
K
2
1
3
0
0
x
4
0
9
4
D
I
E
S
E
L
G
E
N
E
R
A
T
O
R
FUEL
STORAGE
FUEL
STORAGE
2 m
2 m
H
V
A
C
H
V
A
C
1
3
0
0
x
4
0
9
4
D
I
E
S
E
L
G
E
N
E
R
A
T
O
R
H
V
A
C
H
V
A
C
F
o
r
t
C
u
m
b
e
r
l
a
n
d
R
d
FortCumberland Rd
M
e
l
v
i
l
l
e
R
d
L
u
m
s
d
e
n
R
d
APPROVED:
PROJECT No:
SCALE AT A1:
TITLE:
PROJECT:
DRAWING No:
DESIGNED:
CHECKED:
DATE:
REV:
CLIENT:
DRAWING STATUS:
DRAWN:
01
28/10/2019
ILLUSTRATIVE
J Crouch
EN020022 A LeniaA Lenia
J Crouch1:250
EN020022-2.10-EL-Sheet4
AQUIND Interconnector
Application document reference 2.10
Indicative Optical Regeneration Station(s)
Elevations and Floor Plans
Option B
Sheet 4 of 4
2019 BURNS & McDONNELL EUROPE (UK) Limited
c
1 : 250
1
Optical Regeneration Station(s) Compound Plan View
N
LEGEND KEY
ORDER LIMITS
Infrastructure Planning (Applications: Prescribed
Forms and Procedure) Regulations 2009 - Regulation 5(2)(o)