Pump Chambers are alternatively filled and emptied by drawing fluid in through

a common suction manifold and out through common discharge manifold.

The diaphragms in each chamber are linked by a common shaft, so that they

move backwards and forwards in unison.

Compressed air is directed by the air valve alternatively, behind each

diaphragm, to power discharge strokes.

Pump speed, fluid output and pressure (or head) is controlled by increasing or

decreasing the flow of compressed air to the pump.

Page 4: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Suction Cycle:

Fluid is drawn into the Suction Manifold at (C), by the suction stroke of the

diaphragm and into Chamber B.

This ‘opens’ the ball valve (2) to allow liquid to enter the chamber.

Ball valve (4) is drawn into the Valve Seat and ‘closed’ by the diaphragm

suction stroke.

Page 5: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Discharge Cycle: In Chamber (A), air has been applied to the rear of the diaphragm to force out

the Fluid in the chamber through the ball valve (3) to the Discharge Manifold (D).

The discharge stroke ‘closes’ the ball valve (1) to prevent further liquid entering the chamber.

This cycle is repeated to provide a continuous flow to the Discharge Manifold at outlet (D).

Page 6: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Air Operated: • No need of electrical drive. • Easy to buy, use and install.

Self Priming: • No need of priming. • Unloading from drums/ sumps etc. • Replaces the traditional drum pumps • Example: Acid and solvents (raw

material) unloading in pharma and refineries

Page 7: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Seal-less Pumps: • Zero Leakage • Less maintenance compared to sealed

pumps • Ideal for corrosive, abrasive, hazardous

liquids handling • Example: Sulphuric Acid, Ink, Solvents

Can be stalled indefinitely: • Can restart automatically when

pressure is released. • Ideal for filling applications • Example: Oil filling lines

Page 8: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Can run at wide variety of flows: • Through air-regulator • No need of VFD • Example: Unloading applications

Can run dry without damage: • No internal pump damage

• Any other seal pump will have seal failures

• Any motorized pump will have motor damage

• In case of PC pump, the whole pump failure

• Example: Viscous liquids/ slurries prone to choking like fruit pulp

Page 9: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Low Shear: • Low velocity and absence of tight

clearances => low shear • Low product degradation and agitation • Example: Paint, Emulsions, Latex

Can handle solids: • No tight clearances • No mechanical seals • Example: Ceramic, waste-water

treatment

Page 10: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Naturally Intrinsically safe -ATEX Approved models: • Safe for using in hazardous environment

Can operate Submerged: • Air supply and exhaust hose will

extend to pump submerged below • Used when lifting from tank below is

not practical

Page 11: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Compact and Portable: • Not anchored to a foundation

• Easy to move • No alignment issues

• Light weight • One pump can be used for many

intermittent services • Example: Sludge removal from tanks

Page 12: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Paints

Pharmaceutical

Ceramics

Chemicals & Petrochemicals

Page 13: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Food Processing

Water & Waste Water

Construction

Pulp/Paper

Page 14: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Marine

Mining

Automotives

Oil & Gas

Page 15: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Ceramics Slip and glaze, Filter Presses, Abrasive Fluids, and Sanitary Products

Chemical & Petrochemical Oil, Sludge, Chemicals, Acids, Solvents, Hydrocarbons, Polymers, Resins, Dyes, Effluent, Additives

Paints and Coatings Paints, Inks, Dyes, Resins, Adhesives

Food and Beverage Beverages, Dairy products, Purees, Juices, Preserves

Waste Water Chemical and General Waste

Page 16: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Leak Detection Filter/Regulator Stroke counter/Batch control

Level Controllers Surge suppressors Air Dryer

Page 17: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Spare Kits - Blagdon

Reduce frequency of repairs

Increase service life

Increase uptime

Save time and money

Page 18: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

http://www.idexindia.in/blagdon-pump/

Page 19: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Savli, Vadodara

IDEX Fluid & Metering – Manufacturing facility Blagdon AODD Pumps in India

Page 20: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

IFMT India Facility - AODD Value Stream

Page 21: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential

Our Contacts Manufacturing Facilities:

Blagdon Pump

79, Shannon Industrial Estate Shannon, Co.

Clare, Ireland

Tel: +353 61 471933

Fax: +353 61 475046

IDEX Fluid & Metering Pvt. Ltd.

Survey No. 256, GIDC Manjusar, Savli

Near Bombardier Circle,

Distr. Vadodara 391770, India

Tel: +91-2667-662-001

Sales & Support

Blagdon - Mumbai

S 14, First floor

Solitaire Corporate Park, 167, Guru Hargovindji Marg,

Chakala,

Andheri (East), Mumbai 400 093

Tel: +91-22 6643-5552/5555

Email: [email protected]

Blagdon - Delhi

4th flr, Office No. 801 Statesman House, Barakhamba

Road Connaught Place

New Delhi 110001

Tel: +91-11-3044-6482

Email: [email protected]

Blagdon - Chennai

The Executive Centre, Tamarai Tech Park Level 5,

S.P.Plot No.16-19 & 20-A,

Thiru Vi Ka Industrial Estate, Inner Ring Road, Guindy,

Chennai 600032, India

Tel: +91 44 6693 6630

Email: [email protected]

Page 22: Aodd pump operating principle - Blagdon Pump

IDEX Proprietary & Confidential