Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019...

39
DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM (left hand entrance of City Hall) 18 MAIN STREET Sutter Creek, California 1:30 P.M. 1. CALL TO ORDER AND ESTABLISH A QUORUM FOR REGULAR MEETING-1:30 P.M 2. PLEDGE OF ALLEGIANCE TO THE FLAG 3. PUBLIC FORUM Any person may address the Committee regarding matters not on the agenda and within their purview. 4. * CONSENT AGENDA Items listed on the consent agenda are considered routine and may be enacted in one motion. Any item may be removed for discussion at the request of the Committee or the Public. A. Approval of Design Review Committee Minutes of September 18, 2019. 5. * DESIGN CLEARANCE A. 18 Main Street- Request by AT&T to place an additional tower on the roof of City Hall RECOMMENDATION: Review plans and approve or deny design clearance. If denied, provide direction to applicant for design clearance approval. B. Historic Element of the General Plan- review and discuss 6. ADJOURNMENT * Attachments The next scheduled meeting is WEDNESDAY, NOVEMEBR 6 TH , at 1:30 P.M In compliance with the Americans with Disabilities Act, if you need special assistance to participate in this meeting, please contact the City Office at (209) 267-5647. Notification 48 hours prior to the meeting will enable the City to make reasonable arrangements.

Transcript of Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019...

Page 1: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

DESIGN REVIEW COMMITTEE

WEDNESDAY, OCTOBER 16, 2019

CITY HALL CONFERENCE ROOM

(left hand entrance of City Hall)

18 MAIN STREET

Sutter Creek, California

1:30 P.M.

1. CALL TO ORDER AND ESTABLISH A QUORUM FOR REGULAR MEETING-1:30 P.M

2. PLEDGE OF ALLEGIANCE TO THE FLAG

3. PUBLIC FORUM – Any person may address the Committee regarding matters not on the agenda

and within their purview.

4.

*

CONSENT AGENDA – Items listed on the consent agenda are considered routine and may be enacted in

one motion. Any item may be removed for discussion at the request of the Committee or the Public.

A. Approval of Design Review Committee Minutes of September 18, 2019.

5.

*

DESIGN CLEARANCE

A. 18 Main Street- Request by AT&T to place an additional tower on the roof of City Hall

RECOMMENDATION: Review plans and approve or deny design clearance. If denied, provide

direction to applicant for design clearance approval.

B. Historic Element of the General Plan- review and discuss

6. ADJOURNMENT

* Attachments

The next scheduled meeting is WEDNESDAY, NOVEMEBR 6TH, at 1:30 P.M

In compliance with the Americans with Disabilities Act, if you need special assistance to participate in this meeting,

please contact the City Office at (209) 267-5647. Notification 48 hours prior to the meeting will enable the City to make

reasonable arrangements.

Page 2: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

1

MINUTES OF THE DESIGN REVIEW COMMITTEE

September 18, 2019

Committee Members: Staff Present:

Mike O’Neill Amy Gedney, City Manager

John Otto Karen Darrow, City Clerk

Sandi Baracco

Susan Peters

Absent: Sharyn Brown

1. CALL TO ORDER -1:30 P.M

Chairman Mike O’Neill called the meeting to order at 1:30 p.m.

2. PLEDGE OF ALLEGIANCE TO THE FLAG

Chairman O’Neill led the Pledge of Allegiance.

3. PUBLIC FORUM

Committee member Otto reiterated his previous request for the Design Review Committee to be able to review

the Historic Element of the General Plan.

4. CONSENT AGENDA – Items listed on the consent agenda are considered routine and may be enacted in

one motion. Any item may be removed for discussion at the request of the Committee or the Public.

A. Approval of Design Review Committee Minutes of August 7, 2019.

M/S Otto/O’Neill to approve the Design Review Committee Minutes of August 7, 2019, as

amended. AYES: Baracco, Otto, Peters and O’Neill NOES: None ABSTAIN: None ABSENT: Brown MOTION CARRIED

5. DESIGN CLEARANCE

A. 170 China Gulch Rd: 018-054-009 Owner: Doran Fry

RECOMMENDATION: Review plans as presented and provide applicant direction for design

clearance.

M/S Peters/Otto to issue design clearance for 170 China Gulch Rd., as presented because the

windows are compatible with the existing structure, which is not historic. AYES: Baracco, Otto, Peters and O’Neill NOES: None ABSTAIN: None ABSENT: Brown MOTION CARRIED

kdarrow
Textbox
Item 4A
Page 3: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

2

The committee requested that staff revise the application to include a requirement for applicant to

provide proof of previous approvals.

6. ADJOURNMENT

The meeting was adjourned at 2:22 p.m.

_________________________________ ___________________________________

Karen Darrow, City Clerk Mike O’Neill, Chairman

Date Approved:

Page 4: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

City of Sutter Creek

Design Review Checklist For Commercial Projects

within the Historic District

Page 1 of 3

Please complete the “Existing & Proposed” Columns. Please submit your plans in print ready.pdf to be printed as 11 x 17. Please show: elevations, site plan, spot grades,

and include elevations at the corners of buildings and also include any existing historic features.

DATE: ____________________________

TO: DESIGN REVIEW COMMITTEE

FROM: ____________________________ REVIEWED and SUBMITTED BY: ____________________

Project Address: ________________________________________

# Design

Standard

Reference

Description Design Criteria

Requirements:

Existing: Proposed: Has

design

criteria

been

met?

Y/N?

Recommendations,

if any to meet

Design Criteria:

1. Zoning

2. District: Historic

3. Lot Size: N/A

4. Set Back

requirements:

5. Front 25’

6. Side 5’

7. Rear 10’

8. Siting:

9. Lot coverage

10. Are there

existing historic

features?

11. Structure Type

12. Max Building

height

35’

13. Roof pitch In new construction,

reflect historic style

jphillips
Typewritten Text
9/13/2019
jphillips
Typewritten Text
James Phillips
jphillips
Typewritten Text
18 Main Street
jphillips
Typewritten Text
MVMV
jphillips
Typewritten Text
jphillips
Typewritten Text
500 +/- S.F.500 +/- S.F.
jphillips
Typewritten Text
Existing Building with 3 Rooftop Mounted Antennas
jphillips
Typewritten Text
Existing Building with 4 Rooftop Mounted Antennas
jphillips
Typewritten Text
Building Rooftop
jphillips
Typewritten Text
Building Rooftop
jphillips
Typewritten Text
33' +/-No Change
jphillips
Typewritten Text
N/AN/A
jphillips
Typewritten Text
N/AN/A
kdarrow
Textbox
Item 5A
Page 5: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

City of Sutter Creek

Design Review Checklist For Commercial Projects

within the Historic District

Page 2 of 3

# Design

Standard

Reference

Description Design Criteria

Requirements:

Existing: Proposed: Has

design

criteria

been

met?

Y/N?

Recommendations,

if any to meet

Design Criteria:

14. Style National, shotgun,

Victorian, or

craftsman

15. 3.4.2 Exterior Finish

and color

scheme

16. 3.4.3 Doors Consistent in shape

and scale with

building’s style.

17. 3.4.4 Windows Match historic style

with panes and trim.

18. 3.4.5 Lighting Match architecturally

19. 3.4.6 Fences Wood picket,

masonry, simple iron

or wire or dry stacked

stone

20. 3.4.7 Mechanical

Equipment

21. Siding Match historic style

22. Roofing

material

Match historic style

23. Porches Match the building in

historic character

jphillips
Typewritten Text
ShotgunNo Change
jphillips
Typewritten Text
White Building Green Roof
jphillips
Typewritten Text
No Change
jphillips
Typewritten Text
N/AN/A
jphillips
Typewritten Text
N/AN/A
jphillips
Typewritten Text
N/AN/A
jphillips
Typewritten Text
N/AN/A
jphillips
Typewritten Text
N/A N/A
jphillips
Typewritten Text
N/AN/A
jphillips
Typewritten Text
N/A N/A
jphillips
Typewritten Text
N/A N/A
Page 6: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

City of Sutter Creek

Design Review Checklist For Commercial Projects

within the Historic District

Page 3 of 3

24. Does the

structure blend

as proposed?

Other Comments:

jphillips
Typewritten Text
N/A N/A
jphillips
Typewritten Text
AT&T proposes to upgrade the Existing Wireless Facility to better enhance the E911 services in the City of Sutter Creek. The modification includes replacing (3) Existing Antennas plus the addition of 1 New Antenna all of which will be the same size and height mounted on top of the Existing Rooftop. Please contact: James Phillips Project Manager – Northern California 3443 Airport Road, Sacramento, CA 95834 Mobile: (530) 333-5786 Email: [email protected] www.mastecnetworksolutions.com
Page 7: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

1387 Calle Avanzado. San Clemente, CA 92673 949-391-6824

Structural Analysis

AT&T

March 19, 2019

Site Name DT SUTTER CREEK Site Number CVL01219 Client MASTEC Proposed Carrier AT&T

Site Location

18 MAIN STREET SUTTER CREEK, CA 9568538.392219 N NAD83 -120.802416 W NAD83

Structure Type Rooftop Structural Usage Ratio 99.3% Overall Result Pass

Upon reviewing the results of this analysis, it is our opinion that the structure does meet the specified IBC/ASCE/TIA code requirements. The antenna mounts and rooftop framing are therefore deemed adequate to support the existing and proposed loading as listed in this report.

Page 8: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Page 1

Summary of Contents Introduction Opening Statement Project Description Criteria Conclusion

Calculations

Appendix A Design Tables & Resources Used

Assumptions and Limitations Our structural calculations are completed assuming all information provided to M SQUARED WIRELESS is accurate and applicable to this site. For the purposes of calculations, we assume an overall structure condition of “like new” and all members and connections to be free of corrosion and/or structural defects. The structure owner and/or contractor shall verify the structure’s condition prior to installation of any proposed equipment. If actual conditions differ from those described in this report M SQUARED WIRELESS should be notified immediately to complete a revised evaluation. Our evaluation is completed using standard TIA, AISC, ACI, and ASCE methods and procedures. Our structural results are proprietary and should not be used by others as their own. M SQUARED WIRELESS is not responsible for decisions made by others that are or are not based on our supplied assumptions and conclusions.

Page 9: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Page 2

INTRODUCTION At the request of AT&T, M SQUARED WIRELESS has performed a structural analysis for the proposed modifications. All supporting documents have been obtained from the client and are assumed to be accurate and applicable at this site. The antenna mounts and rooftop were analyzed using Risa3D version 17.0. Supporting Documentation Antenna Loading M.SQUARED WIRELESS, Construction Drawings, Dated:

02/13/19 Previous Analysis M.SQUARED WIRELESS, Structural Analysis, Dated:

11/29/16 Previous Analysis Wireless Structures Consulting, PC, Structural Analysis, Dated:

04/17/11 Analysis Code Requirements Wind Speed 95 mph (Vult) Wind Speed w/ ice 30 mph (3-Second Gust) w/ 0” ice TIA Revision ANSI/TIA-222-H Adopted IBC 2018 IBC / 2019 CBC Structure Class 2 Exposure Category C Topographic Category 1 Calculated Crest Height 1186

CONCLUSION Upon reviewing the results of this analysis, it is our opinion that the structure does meet the specified IBC/ASCE/TIA code requirements. The antenna mounts and rooftop framing are therefore deemed adequate to support the existing and proposed loading as listed in this report.

Page 10: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Page 3

Existing and Reserved Loading

Mount Height (ft) Qty. Appurtenance Mount Type Carrier

51.0 3 Kathrein 800-10516

Tripod AT&T

2 DBVP DLA-VR-07-360-0N 3 TMA

Equipment Area

4 RRUs 11 Pipe Mount 3 RRUs 12 To Be Removed Loading

Mount

Height (ft) Qty. Appurtenance Mount Type Carrier

51.0 3 Kathrein 800-10516 Tripod AT&T 2 DBVP DLA-VR-07-360-0N

Equipment Area

1 RRUs 11 Pipe Mount 3 RRUs 12 Proposed Loading

Mount

Height (ft) Qty. Appurtenance Mount Type Carrier

51.0 4 Kathrein 800-10776

(N) Tripod

AT&T

9 TMA 1 Diplexer

Equipment Area

2 RRUs 11 Pipe Mount 3 RRUs 4449 B5 / B12

3 RRUs 8843 B2 / B66

Page 11: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Page 4

Final Configuration

Mount Height (ft) Qty. Appurtenance Mount Type Carrier

51.0 4 Kathrein 800-10776

(N) Tripod

AT&T

12 TMA 1 Diplexer

Equipment Area

5 RRUs 11 Pipe Mount 3 RRUs 4449 B5 / B12

3 RRUs 8843 B2 / B66 Check Roof Joists 2x8 @ 24” O.C. w/ 13’ span. DL = 20 psf LL = 20 psf Tripod DL = 258 lbs Tripod Max vertical load = 460 lbs – 258 lbs = 202 lbs (W) E 2x8s OK See attached Enercalc Structure Usages 2x8 .993 PIPE_2.5 .217 LL2x2x4x3 .021 RATING= 99.3%

Page 12: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Site Name: CVL01219 Design Wind Velocity: 95Client: Mastec Wind Centerline: 51

Carrier: AT&T Exposure Category: CDate: 3/19/2019 Code TIA-222-H

Shape = RoundCa = 1.2qz = 23.1 Fp = 0.20F = 27.7

Appurtenance Name Quantity Weight (lbs)F-norm(lbs)

F-perp (lbs)

F-norm (lbs)

F-perp (lbs)

Kathrein 800-10776 3.0 50.0 32.1 32.1 10.1 10.1RRUs 11 3.0 50.7 64.3 27.4 10.2 10.2RRUs 11 2.0 50.7 64.3 27.4 10.2 10.2RRUs 4449 B5 / B12 3.0 80.0 45.4 32.5 16.1 16.1RRUs 8843 B2 / B66 3.0 80.0 37.9 31.3 16.1 16.1TMA 3.0 14.8 13.2 7.3 3.0 3.0TMA 3.0 14.8 13.2 7.3 3.0 3.0TMA 3.0 14.8 13.2 7.3 3.0 3.0TMA 3.0 14.8 13.2 7.3 3.0 3.0Diplexer 3.0 7.1 4.6 4.3 1.4 1.4

Wind Force Seismic Force

Page 13: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 14: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 15: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 16: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 17: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Member Primary Data

Hot Rolled Steel Properties

Basic Load Cases

Load Combinations

Page 18: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Load Combinations (Continued)

Envelope Joint Reactions

Envelope AISC 14th(360-10): LRFD Steel Code Checks

Page 19: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Wood BeamMLELic. # : KW-06012339

DESCRIPTION: 2x8

Title Block Line 1You can change this areausing the "Settings" menu itemand then using the "Printing &Title Block" selection.Title Block Line 6

Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.30 .File = C:\DROPBO~1\M2\2019\03-MAR~1\AT&T\CVL01219\Calc\CVL01219.ec6 .

Project Title:Engineer:Project ID:

Printed: 19 MAR 2019, 5:23PM

Project Descr:

CODE REFERENCESCalculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10Load Combination Set : ASCE 7-16Material Properties

Beam Bracing : Beam is Fully Braced against lateral-torsional buckling

Allowable Stress Design

Douglas Fir-LarchNo.1 & Better

120012001550625

1800660

180800 31.21

Analysis Method :

Eminbend - xx ksiWood Species :Wood Grade :

Fb +psipsi

Fv psi

Fb -

Ft psi

Fc - Prll psipsiFc - Perp

E : Modulus of ElasticityEbend- xx ksi

Density pcf

Load Combination :ASCE 7-16

Applied Loads Service loads entered. Load Factors will be applied for calculations.

Uniform Load : D = 0.020, Lr = 0.020 ksf, Tributary Width = 2.0 ftPoint Load : D = 0.2580, W = 0.2020 k @ 2.0 ft

DESIGN SUMMARY Design OKMaximum Bending Stress Ratio 0.993: 1

Load Combination +D+Lr+H

Span # where maximum occurs Span # 1Location of maximum on span 6.026ft

95.55 psi=

=

FB : Allowable 1,800.00psi Fv : Allowable

2x8Section used for this span

Span # where maximum occursLocation of maximum on span

Span # 1=

Load Combination +D+Lr+H=

=

=

225.00 psi==

Section used for this span 2x8fb : Actual

Maximum Shear Stress Ratio 0.425 : 1

0.000 ft==

1,787.89psi fv : Actual

Maximum Deflection

0 <360219

Ratio = 0 <180

Max Downward Transient Deflection 0.302 in 517Ratio = >=360Max Upward Transient Deflection 0.000 in Ratio =Max Downward Total Deflection 0.711 in Ratio = >=180Max Upward Total Deflection 0.000 in

Maximum Forces & Stresses for Load Combinations

Span #Moment ValuesLoad Combination

C i C LC CCC F/V mr tdShear ValuesMax Stress Ratios

M CV fbM fvF'b V F'vSegment Length+D+H 0.00 0.00 0.000.00

1.00Length = 13.0 ft 1 0.791 0.388 0.90 1.200 1.00 1.00 1.00 1.12 1,025.24 1296.00 0.46 162.001.00 62.831.00+D+L+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.712 0.349 1.00 1.200 1.00 1.00 1.00 1.12 1,025.24 1440.00 0.46 180.001.00 62.831.00+D+Lr+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.993 0.425 1.25 1.200 1.00 1.00 1.00 1.96 1,787.89 1800.00 0.69 225.001.00 95.551.00+D+S+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.619 0.304 1.15 1.200 1.00 1.00 1.00 1.12 1,025.24 1656.00 0.46 207.001.00 62.831.00+D+0.750Lr+0.750L+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.887 0.388 1.25 1.200 1.00 1.00 1.00 1.75 1,596.27 1800.00 0.63 225.001.00 87.371.00+D+0.750L+0.750S+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00

Page 20: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Wood BeamMLELic. # : KW-06012339

DESCRIPTION: 2x8

Title Block Line 1You can change this areausing the "Settings" menu itemand then using the "Printing &Title Block" selection.Title Block Line 6

Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.30 .File = C:\DROPBO~1\M2\2019\03-MAR~1\AT&T\CVL01219\Calc\CVL01219.ec6 .

Project Title:Engineer:Project ID:

Printed: 19 MAR 2019, 5:23PM

Project Descr:

Span #Moment ValuesLoad Combination

C i C LC CCC F/V mr tdShear ValuesMax Stress Ratios

M CV fbM fvF'b V F'vSegment Length1.00Length = 13.0 ft 1 0.619 0.304 1.15 1.200 1.00 1.00 1.00 1.12 1,025.24 1656.00 0.46 207.001.00 62.831.00+D+0.60W+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.502 0.267 1.60 1.200 1.00 1.00 1.00 1.27 1,156.78 2304.00 0.56 288.001.00 76.981.00+D+0.750Lr+0.450W+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.733 0.340 1.60 1.200 1.00 1.00 1.00 1.85 1,687.80 2304.00 0.71 288.001.00 97.981.00+D+0.750S+0.450W+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.487 0.255 1.60 1.200 1.00 1.00 1.00 1.23 1,123.15 2304.00 0.53 288.001.00 73.441.00+0.60D+0.60W+0.60H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.325 0.180 1.60 1.200 1.00 1.00 1.00 0.82 749.33 2304.00 0.38 288.001.00 51.841.00+D+0.70E+0.60H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.445 0.218 1.60 1.200 1.00 1.00 1.00 1.12 1,025.24 2304.00 0.46 288.001.00 62.831.00+D+0.750L+0.750S+0.5250E+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.445 0.218 1.60 1.200 1.00 1.00 1.00 1.12 1,025.24 2304.00 0.46 288.001.00 62.831.00+0.60D+0.70E+H 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 13.0 ft 1 0.267 0.131 1.60 1.200 1.00 1.00 1.00 0.67 615.15 2304.00 0.27 288.001.00 37.70

Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" DeflOverall Maximum Deflections

+D+Lr+H 1 0.7106 6.405 0.0000 0.000

Load Combination Support 1 Support 2Vertical Reactions Support notation : Far left is #1 Values in KIPS

Overall MAXimum 0.750 0.560Overall MINimum 0.171 0.031+D+H 0.478 0.300+D+L+H 0.478 0.300+D+Lr+H 0.738 0.560+D+S+H 0.478 0.300+D+0.750Lr+0.750L+H 0.673 0.495+D+0.750L+0.750S+H 0.478 0.300+D+0.60W+H 0.581 0.318+D+0.750Lr+0.450W+H 0.750 0.509+D+0.750S+0.450W+H 0.555 0.314+0.60D+0.60W+0.60H 0.390 0.198+D+0.70E+0.60H 0.478 0.300+D+0.750L+0.750S+0.5250E+H 0.478 0.300+0.60D+0.70E+H 0.287 0.180D Only 0.478 0.300Lr Only 0.260 0.260L OnlyS OnlyW Only 0.171 0.031E OnlyH Only

Page 21: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

Page 5

APPENDIX A Design Tables & Resources

Page 22: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

wp

wpF p w p

wp

ppDSp WISF

hz

IR

WSaF

p

p

pDSpp

ppDSp WISF

Page 23: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

��������� ���� ��������������

���������� ������������������� ��!��"��#���$�%�������&���$'����%��(�)&����!��$ ���

�� ��������������

*+,-./0123-4,5631

733-861,5+9: �%�������;'����%��(�)

<=+>,5631: ��%)?�

@64+95,4A: ����'��'����%�B��������C

D,E,-8@FA+: G!��"��

H+2+-+1.+

I3.J4+15:

�GKL'��

H69M7,5+N3-F: OO

*65+7=,99: P

Q7<HD3-6E315,=H+9A319+*A+.5-J4 I+96N1D3-6E315,=H+9A319+*A+.5-J4

R,96.S,-,4+5+-9

T,4+ U,=J+ I+9.-6A5631

GG ��(�� VKW������"�����X�!����$����Y

G� ����B VKW������"�����X�!����$����Y

GVG ��)�� G��!'"���?�!���!��������!�!������Z���!

GV� ��(�% G��!'"���?�!���!��������!�!������Z���!

GPG ��(�� [�"!����!��"���!����Z���!������G�

GP� ����� [�"!����!��"���!����Z���!������G�

\]8865631,=0123-4,5631

T,4+ U,=J+ I+9.-6A5631

GP P G!��"���!�������!����

� ��(B( G��!�"���?�������?�����������

Z ���B G��!�"���?�������?�����������

WG ����) �!??���!���?���_X����Y

`abcd

efghfifjklmnoppqrstuvwouxsgpyifzfgsyypy

� � ( ) % �� �� S+-638{9|

����

����

����

����

��(�

��B�

��)�

*,{N|

� � ( ) % �� �� S+-638{9|

����

����

����

����

��(�

*,{N|

Page 24: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

��������� ���� ��������������

���������� ������������������� ��!��"��#���$�%�������&���$'����%��(�)&����!��$ ���

*� ���) �!++���!���+���,-����.

/0� ����� 120�!�,���������!�!������

3/0� ��4�� 5��!�"���+�������+�������/0�

/0�1 ����( 5��!"���+�!��!�,���������!�!������

�� �� ����'�!���������������!����-�.

5�*� ��(�� /���������������,'����!�!�������"�����-����.

5�6� ���4% 3�����!����+��"'�� �����!��������!�!������-�7������������+

!8�!!����!��4��!���.

5�9 ��4 3�����!��!�!�"����������!�!������:���!-����.

5�*� ����4 /���������������,'����!�!�������"�����-����.

5�6� ����( 3�����!����+��"'�� �����!��������!�!������-�7������������+

!8�!!����!��4��!���.

5�9 ��) 3�����!��!�!�"����������!�!������:���!-����.

/0�� ��4 3�����!��!�!�"����������!�!������:���!-/0�.

;<=>=?@AB?CDECFGB=E<=>=HIJI;>=KA=FBGDL?BGB=M>AMFGAGN=DEN=DB?BMB<=OGA@=?M>GDLE=ACD=GBCMDACD=?NGE=E@>CDPB<=Q@CAECDPFME=

GEMRBCMDR>MF=??ST?=>??<M@AEFMDKC>NGDLM@BR@BMQBGCD=EK>MNB<C?BMMAUCB<B<=AMFGAV@B<M>CBLWGOCDPX@>C?ECFBCMDQ=KM>=R>MF==ECDPUCB<

E=?CPDS

YZ[\]Z_ a

�� ����������!���:��!�����!6�5�0!��������5��:!�5!��"��9!����b!�5!�:��!��

b���!��!��+��"�������!�!��!�������c!����!���!��!:!����!����!��d�����������������������������������"!���!��������������

���������+����������������!"��!������!�!��!�����!�!��������������!��!����!��!�����+�������!��+�������������c��������"�!�!��

!8�"����������:!��+��������+�����������d�����������������������������!����!!�������!����!��!����+!�������������!�������!��������!

��!�+������+��"������!����!��!�����e���"!���+������"�!�!�����+!��������d��:���!8�!��!��!���,��c�!��!����!+�!���+�������!d���

�����������!+����!���������+���!�!f���!��+�������+!�������������!���!�����������������!�!������+��!�!�������:��!�������c!����!�

6�!���+��!��+��"�����+��"����c!����!����"!�������������������+��"������!�6�!�+��!�������+����c!����!��!�����"��������:����

��!��:!����������������!����!��!��������!+�������������!�����:��������!���!������+����!�����������!�!�����!����������!���������!

������������!�!�����

Page 25: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

��������� ���� ��������������

���������� ������������������� �!���"���#�$�������%���#&����$��'�(%����)��# ���

�� ��������������

*+,-./0123-4,5631

733-861,5+9: �$�������;&����$��'�(

<=+>,5631: ��$(?�

@64+95,4A: ����&��&����$�B�����'�BC

D,E,-8@FA+: G���

H*7<IJKL

MNO��&P)�� ((Q��

MNO�B&P)�� R�Q��

MNOB�&P)�� RRQ��

MNO���&P)�� $�Q��

N��S��)����O $$Q��

N��S��)����OO �BQ��

N��S��)����OOO ���Q��

N��S��)����OT ��BQ��

H*7<IJKU

MNO��&P)�� R�Q��

MNO�B&P)�� R�Q��

MNOB�&P)�� $BQ��

MNO���&P)�� ��Q��

N��S��)����O ���Q��

N��S��)����OO ���Q��

N��S��)����OOO&OT ��BQ��

H*7<IJUV

�WXR&�BG���W�))� $BQ��

YZ[\[]_]abcade[cZ[\[fghgY\[i_[debj]e[k\_kde_el[bcl[b]kZ[me_[]k\ebjc[_ab[eakb_ab[]lec[c\abnZ[oa_cabn

dkc[eckpakbp\kd[]]qr][\]]Zk_cdkbia\lebjk p koeab[ci\klZa]kk_saZZ[_kde_t Zk\ajuemabnv\a]cadakbo[ik\[

p\kd[[cabnsaZc[]anbq

w69.=,64+-

�� ����������)���)������)�?��Q�������x��)����WXR��������)�������)�)��)��!���)���)�)��y)��WXR;�����������������

��)��������)��)�������������������)��)����!�����))���������?��)���������)�z����Q)���)�;����!)����)!���){��������)����

��)����!�����))�������������)�)?��);���x��)�!�����))�������������������)��|}�X�~����)��)��)��!���&����)�)�����)����

��������)�;��)�)��������)�)�Q����������)�����x)����������!����Q���??)��!�)��)����������������)�)����)!������!���&����)

�)�����)�����

M�����������)�����;����)�;��)�����Q������)�;�����)����!����)�����������)){�Q��)�?���������!��������������

G���)��)��?��Q�������)�)��)�������!)����)���)��)x)����)����)��;�����������������������������������Q)���)������������

�����������?����������������)Q��)������)�)��)�����)�)��������������)��)����)��)�����?�������)��?�������������!������

��Q�)�)��){�Q����������x)��?��������?�����������;�����������������������������)����))�������)����)��)����?)�������������)�

������)��������)��)�?������?��Q������)����)��)���������Q)���?������Q�)�)�����?)��������;��x���){�)��)��)���S��!�)��)

����)?�)���?�������);��������������)?����)���������?���)�)����)��?�������?)�������������)���)�����������������)�)������?��)

�)�������x��)�������!)����)���)���?��)��?��Q�����?��Q����!)����)����Q)�������������������?��Q������)���)�?��)�������?

����!)����)��)�����Q��������x������)��x)����������������)����)��)��������)?�������������)�����x��������)���)������?����)

������

���������������������������������������

Page 26: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

��������� ���� ��������������

���������� ������������������� �!���"���#�$�������%���#&����$��'�(%����)��# ���

����!)����)��)�����*��������+������)��+)����������������)����)��)��������),�������������)�����+��������)���)������,����)

�����������)�)�����)����������)���������)������������)�)�����

Page 27: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM

6

OR6

REVISIONSREV. ZONE

1. ALL METRIC DIMENSIONS ARE IN BRACKETS.

OR

A

NOTES:

DESCRIPTIONOGG

DATEBYREDRAWN & REVISED 10/04/10

ITEM PART NO. DESCRIPTION

TP-G

300-

B

TP-G

300-

72 Q

TY.

TP-G

300-

96 Q

TY.

TP-G

300-

126

QTY

.

TP-G

312-

72 Q

TY.

TP-G

312-

96 Q

TY.

TP-G

312-

126

QTY

.

WEIGHT

1 TPG412B.04 TRIPOD BRACE 3 3 3 3 3 3 3 4.99 LBS2 TPG412B.09 TRIPOD LEG ANGLE 6 6 6 6 6 6 6 14.74 LBS3 TPG300B01 2.875-3.50" TRIPOD CLAMP 6 6 6 6 6 6 6 3.09 LBS4 TPG412B.07 TRIPOD FOOT 3 3 3 3 3 3 3 5.84 LBS5 GWF-05 5/8" GALV FLAT WASHER 6 6 6 6 6 6 6 0.02 LBS6 GB-05245 5/8"X2-1/2" GALVBOLT KIT 12 12 12 12 6 6 6 0.13 LBS7 GB-05305 5/8" X 3.0" GALV BOLT KIT 6 - - - - - - 0.13 LBS8 MT54672 2.875" O.D X 72" PIPE - 1 - - - - - 34.88 LBS8 MT54696 2.875" O.D X 96" PIPE - - 1 - - - - 46.51 LBS8 MT-546-126 2.875" O.D X 126" PIPE - - - 1 - - - 61.05 LBS8 MT54772 3.50" O.D X 72" PIPE - - - - 1 - - 45.21 LBS8 MT54796 3.50" O.D X 96" PIPE - - - - - 1 - 60.83 LBS8 MT-547-126 3.50" O.D X 126" PIPE - - - - - - 1 79.83 LBS

OGG

RU.S.A.

10/04/10

A

B

C

D

A

B

C

D

8 7 6 5 4 3 2 1

8 7 6 5 4 3

DESCRIPTION:

MATERIAL:

2 1

Andrew Corporation.

SHEET: PART NUMBER:

±2°±1/32.06

.030

DO NOT SCALE THIS PRINT

TOLERANCES UNLESS OTHERWISE SPECIFIED:ALL DIMENSIONS ARE IN INCHES U.O.S.

REMOVE BURRS AND BREAK EDGES .005

.XX = ±

.XXX= ±

.X = ± ANGLES FRACTIONS

SEE TABLE

CHECKED BY:

.12DATE:

GALV A123FINISH:REVISION:

NTS

A36,A500,A529

TPSCALE:

ASSEMBLY DRAWINGDRAWING TYPE:

WEIGHT

DRAWN BY:

1 of 1These drawings and specifications are the proprietary property of ANDREW CORPORATION and may be used only for the specific purpose authorized in writing by

ORLAND PARK, IL. 60462

1631.5REF

64

1079REF

4236 919.5

REF3

TP-G312-72 SHOWN

1

2

8

4 75

6

7

Page 28: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 29: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 30: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 31: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 32: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 33: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 34: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 35: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 36: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 37: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 38: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM
Page 39: Any person may address the Committee regarding matters not ... DRC Agenda Packet.pdf · 10/16/2019  · DESIGN REVIEW COMMITTEE WEDNESDAY, OCTOBER 16, 2019 CITY HALL CONFERENCE ROOM