Antibodies - Key Marker Performance - July 2015

12
Antibodies Key Marker Performance Performance Data CRP Recombinant Fabs Troponin I Monoclonals D – Dimer Monoclonals HbA1c Monoclonals Capabilities Monoclonal Antibodies Polyclonal Antibodies Recombinant Fab Antibodies Quality Innovation Results Partnership

Transcript of Antibodies - Key Marker Performance - July 2015

Page 1: Antibodies - Key Marker Performance - July 2015

AntibodiesKey Marker Performance

Performance Data CRP Recombinant FabsTroponin I MonoclonalsD – Dimer Monoclonals

HbA1c Monoclonals

CapabilitiesMonoclonal Antibodies

Polyclonal AntibodiesRecombinant Fab Antibodies

Quality InnovationResultsPartnership

Page 2: Antibodies - Key Marker Performance - July 2015

Be confident in your results when you choose BBI’s monoclonal antibodies for your next assay:

Tested in ELISA Tested in lateral flow Recommended pairings provided Positive customer feedback

We have now introduced highly sensitive recombinant Fab antibodies to improve your next generation assays.

Why choose BBI?

Quick Links

CRP Data >Troponin I Data >D-Dimer Data >HbA1c Data >

Monoclonal Antibodies >Polyclonal Antibodies >Recombinant Fab Antibodies >

How to Order >

Page 3: Antibodies - Key Marker Performance - July 2015

Antibody Spotlight NEW DATA – CRP Recombinant FAB

Return home >

100

75 50 25 10 5 2 1 00

200400600800

10001200

Comparison of BR228-D4A3 with commercially available antibodies

BR228-D4A3

Competitor A

Competitor B

Flu Fab

CRP conc (ng/mL)

Pea

k he

ight

Reader

CRP conc (ng/ml)100 75 50 25 10 5 2 1 0

BBI antibody, BR228-D4A3

Competitor B antibody

Competitor A antibody

Visual

Lateral Flow: Comparison of BR228-D4A3 with commercially available antibodies

Our CRP antibodies have a dynamic range of antigen detection of 151 - 231000 ng/ml determined by ELISA. Our CRP antibodies can be used in a competitive ELISA, without need for pairing. Alternatively they can be paired with other antibodies.

BR228-D4A3 antibody, is able to detect down to < 1ng/ml in Lateral Flow allowing you to produce high sensitivity assays. We have determined the affinity constant for this antibody to be 0.138 nM.

Page 4: Antibodies - Key Marker Performance - July 2015

Antibody Spotlight NEW DATA – Troponin I Lateral Flow Data Detect down to 12.5ng/ml Troponin I in Lateral Flow using BBI’s Lateral Flow antibodies Epitopes matching those prevalent in Troponin I assays The antibodies are also suitable for ELISA

Return home >

Capture: BM322-K5F1 & BM322-N4D1 (0.8 mg/ml)Detection: BM322-M4E5

TnI (ng/ml): 0 12.5 25 50 100 200 0 12.5 25 50 100 200

Capture: BM322-K5F1 (0.8 mg/ml)Detection: BM322-M4E5

Antibody Epitope AAsBM322-K5F1 QPLELTGLGFAELQDL 81-96

BM322-M4E5 LDLRAHLKQVKKEDTE 167-182

BM322-N4D1 EVGDWRKNIDALSGME 187-202

Page 5: Antibodies - Key Marker Performance - July 2015

Lane 1: Native Human D-Dimer

Lane 2: Human Serum

Lane 3: Native Fibrinogen

Lane 4: Native Plasminogen

D-Dimer clones 1D2 and 3B6 3B6 clone used in a number of commercially

available assays

Tested in Lateral Flow, Sandwich ELISA,

Western Blot and Latex Agglutination

Clones cited in 100’s of peer-reviewed journal

papers

Do not detect the closely related molecules

Fibrinogen and Plasminogen

Product Code Description

BM243-1D2Sandwich ELISA: Detection Ab paired with BM243-3B6 as CaptureLateral Flow: Capture Ab paired with BM243-3B6 as DetectionWestern Blot

BM243-3B6

Sandwich ELISA: Capture Ab paired with BM243-1D2 as DetectionLateral Flow: Detection Ab paired with BM243-1D2 as CaptureLatex AgglutinationWestern Blot

Antibody Spotlight D – Dimer Monoclonal Antibodies

Return home >

Page 6: Antibodies - Key Marker Performance - July 2015

Antibody Spotlight HbA1c Monoclonal Antibodies

Product Code Description

BM300-F7C2ELISA - STAR PAIR: Detection antibody paired with BM302-F1B4 (Hb mAb), or paired with BM302-S6B9

BM300-S3C9 Lateral Flow & Turbidimetric Assay : Detection paired with BM302-F1B4 (Hb ab)

BM300-H2B1 Lateral Flow & Turbidimetric Assay : Detection paired with BM302-F1B4 (Hb ab)

BM300-H2E2 ELISA, Lateral Flow: Detection paired with BM302-S6B9 (Hb mAb)

BM300-P4D1 ELISA, Lateral Flow: Detection paired with BM302-S6B9 (Hb mAb)

Some antibodies are currently not available to be sold into the USA. Return home >

BM300-F7C2 is able to quantify levels of HbA1c in patient blood samples using an ELISA assay, correlating with results from a commercial HPLC platform (Biorad Variant II).

Page 7: Antibodies - Key Marker Performance - July 2015

Antibody Spotlight HbA1c Monoclonal Antibodies

Return home >

Sample: Blank Level1 Level2 Level3 Level4

Lateral Flow Test for HbA1c

Capture: Mouse anti-HbA1c BM300-F7C2Detector: Mouse anti-Hb BM302-F1B4

Lateral flow test shows that as levels of HbA1c increases the signal strength of antibody detection also increases

Page 8: Antibodies - Key Marker Performance - July 2015

Our Capabilities | Monoclonal Antibodies

Cardiac Infectious Disease Listeria Veterinary D-Dimer C. difficile Toxin A Malaria HRP2 Canine Distemper VirusMyoglobin C. difficile Toxin B Malaria LDH (pan) Avian Influenza H5Troponin I Chikungunya Malaria LDH (Pf & Pv) FeLV

Dengue NS1 Norovirus Brucella LPSDiabetes Ebola Reston PBP2a EnrofloxacinHb Ebola Sudan TB Goat IgGHbA1c Ebola Zaire Canine IgM  HAV Tumour Chicken IgYDrugs of abuse H. pylori CA125 GSTTHCΔ9 HAV CA15-3  HBV CA19-9Hormones Hepatitis B CalcitoninProgesterone HIV p24  PTH HIV gp36 Immunoglobulins

HIV gp41 IgAPregnancy Influenza A IgEAFP Influenza B

Leptospira

   

        

Return home >

Page 9: Antibodies - Key Marker Performance - July 2015

Our Capabilities | Polyclonal AntibodiesInflammation Pregnancy RenalCRP AFP A2M    B2MHormones Inflammatory Cystatin CHCG A1AT  αHCG      Haematology MetabolismImmunoglobulins Haptoglobin CeruloplasminIgA Ferritin  IgM Haemoglobin  IgG  Albumin  

Return home >

Page 10: Antibodies - Key Marker Performance - July 2015

Our Capabilities | Recombinant Fab Antibodies

* Detection Ranges are assay dependent and optimised for specific clinical conditions, therefore may be improved with optimisation

Biomarker Detection Range* Capture Antibody Detection Antibody  

HSP60 0.1 - 1200 ng/mL BR100-G2A7 BR100-H4C2  

Adiponectin 0.1 - 525 ng/mL BR101-P7E2 BR101-M3H8  

Adiponectin 230 - 59118 ng/mL BR101-H2B4 (Competitive ELISA)  

Angiopoietin 2 0.001 - 97 ng/mL BR103-P4E8 BR103-V5F2  

Big Endothelin 1 0.001 - 1.8 ng/mL BR104-D6A4 BR104-H1A4  

Calcitonin 0.006 - 2 ng/mL BR388-G6B1 BR388-D5C4  

Cathepsin D 0.03 - 150 ng/mL BR107-F5G2 BR107-K6D3  

Eotaxin 0.007 - 2 ng/mL BR108-M7H3 BR108-K2D9  

Chondrolectin 0.9 - 21 ng/mL BR111-P8G3 BR111-T6B1  

CKBB 0.15 - 33 ng/mL BR112-V6F6 BR112-Z1C4  

Proinsulin C-Peptide 0.09 - 38 ng/mL BR143-G5D3 BR143-K7C9  

CRP 151 - 231000 ng/mL BR228-D4A3 (Competitive ELISA)  

Cystatin C 165 - 9073 ng/mL BR175-G8D9 (Competitive ELISA)  

Cystatin C 165 - 9073 ng/mL BR175-H4C8 (Competitive ELISA)  

E. histolytica not tested BR116-K9F7 BR116-G3A1  

E-selectin 0.05 - 235 ng/mL BR117-K2E7 BR117-H5B6  

FABP Intestine 0.65 - 100 ng/mL BR115-F7G7 BR115-G6B9  

FABP Liver 0.03 - 90 ng/mL BR106-G5A2 BR106-P9F5  

Return home >

Page 11: Antibodies - Key Marker Performance - July 2015

Our Capabilities | Recombinant Fab Antibodies

* Detection Ranges are assay dependent and optimised for specific clinical conditions, therefore may be improved with optimisation

Biomarker Detection Range* Capture Antibody Detection Antibody

G. lamblia not tested BR120-P3F2 & BR120-T1G8

Human Fetal Hemoglobin 1.9 - 305 ng/mL BR121-T5H9 BR121-V5A7

Leptin 3.9 - 691 ng/mL BR123-M4D6 BR123-P4G2

MMP7 0.1 - 293 ng/mL BR124-S4E3 BR124-T6G8

MMP9 Active 11 - 183 ng/mL BR125-N5F7 BR125-M6D6

MPO 2 - 1200 ng/mL BR240-N5G6 BR240-D8B4

Neutrophil Elastase 0.008 - 33 ng/mL BR127-H2A4 BR127-G7C2

Free PAPP A 0.3 - 299 ng/mL BR129-M5E3 BR129-F2H4

Pentraxin 3 4.6 - 876 ng/mL BR130-H2C3 BR130-K6D6

PGDS 0.2 - 85 ng/mL BR131-M6H7 BR131-P7F7

PSAP A 0.013 - 123 ng/mL BR132-T5G4 BR132-S6E4

PSAP B 0.3 - 1500 ng/mL BR133-V6B5 BR133-V4D1

RBP 4 350 - 500000 ng/mL BR134-Z7D3 (Competitive ELISA)

S100 Beta 0.04 - 5.6 ng/mL BR332-G4B9 BR332-F5H7

ST2 1.39 - 97 ng/mL BR139-S7B7 BR139-V8D4

ST2 0.08 - 31 ng/mL BR139-T3G5 BR139-V8D4

Tie2 0.8 - 600 ng/mL BR140-Z7A5 BR140-D9D7

Return home >

Page 12: Antibodies - Key Marker Performance - July 2015

How to Order

Please get in touch to arrange a quote for any of our products.

You can also order directly via our website www.bbisolutions.com

[email protected]

USA: 1-800-423-8199

Intl: +44 (0) 2920 747 232

Quote on ordering – NF JUL

BBI Solutions

bbi_solutions

BBI Solutions

Return home >