Annex3 Technical Specification

33
Technical Specifications (Annex 3) 1. General requirements.......................................................................................................................................... 2 2. Requirements to the Project implementation.................................................................................................... 3 3. Project services requirements............................................................................................................................. 3 4. Powering of the SYSTEM...................................................................................................................................... 4 5. Integration of the SYSTEM................................................................................................................................... 4 6. Access to the SYSTEM........................................................................................................................................... 4 7. Administration of the SYSTEM............................................................................................................................. 4 8. Backup of the SYSTEM.......................................................................................................................................... 4 9. Requirements to the documentation of the SYSTEM......................................................................................... 5 10. Performance of the SYSTEM................................................................................................................................ 5 11. Supported interface types.................................................................................................................................... 5 12. Supported interfaces............................................................................................................................................ 6 13. Supported protocols............................................................................................................................................. 6 14. “Protocol Analyzer”............................................................................................................................................... 6 15. “Call Trace”............................................................................................................................................................ 7 16. “Network Performance Monitoring”................................................................................................................... 7 17. “Roaming and interconnect”............................................................................................................................... 8 18. “Reporting”............................................................................................................................................................ 8 19. “GPRS” measurement mode.............................................................................................................................. 10 20. Geo location........................................................................................................................................................ 10 21. Marketing specialized reporting....................................................................................................................... 10 22. Customer Care specialized tool......................................................................................................................... 11 23. Alarm reporting.................................................................................................................................................. 14 24. Network topology............................................................................................................................................... 15 25. Warranty and service terms.............................................................................................................................. 15 26. System acceptance............................................................................................................................................. 16 27. Training............................................................................................................................................................... 16 28. SYSTEM management........................................................................................................................................ 16 29. Fault tolerance.................................................................................................................................................... 16 30. Security................................................................................................................................................................ 17 31. Monitoring center implementation.................................................................................................................. 17 Appendix 1: “K-Telecom” CJSC Core network topology............................................................................................. 18 Appendix 2: Statement of Compliance (SOC)............................................................................................................ 19 1

Transcript of Annex3 Technical Specification

Page 1: Annex3 Technical Specification

Technical Specifications (Annex 3)

1. General requirements................................................................................................................................................2

2. Requirements to the Project implementation............................................................................................................3

3. Project services requirements....................................................................................................................................3

4. Powering of the SYSTEM............................................................................................................................................4

5. Integration of the SYSTEM.........................................................................................................................................4

6. Access to the SYSTEM.................................................................................................................................................4

7. Administration of the SYSTEM...................................................................................................................................4

8. Backup of the SYSTEM................................................................................................................................................4

9. Requirements to the documentation of the SYSTEM..................................................................................................5

10. Performance of the SYSTEM.......................................................................................................................................5

11. Supported interface types..........................................................................................................................................5

12. Supported interfaces..................................................................................................................................................6

13. Supported protocols...................................................................................................................................................6

14. “Protocol Analyzer”....................................................................................................................................................6

15. “Call Trace”................................................................................................................................................................7

16. “Network Performance Monitoring”..........................................................................................................................7

17. “Roaming and interconnect”......................................................................................................................................8

18. “Reporting”................................................................................................................................................................8

19. “GPRS” measurement mode....................................................................................................................................10

20. Geo location.............................................................................................................................................................10

21. Marketing specialized reporting..............................................................................................................................10

22. Customer Care specialized tool................................................................................................................................11

23. Alarm reporting........................................................................................................................................................14

24. Network topology....................................................................................................................................................15

25. Warranty and service terms.....................................................................................................................................15

26. System acceptance...................................................................................................................................................16

27. Training....................................................................................................................................................................16

28. SYSTEM management..............................................................................................................................................16

29. Fault tolerance.........................................................................................................................................................16

30. Security....................................................................................................................................................................17

31. Monitoring center implementation..........................................................................................................................17

Appendix 1: “K-Telecom” CJSC Core network topology......................................................................................................18

Appendix 2: Statement of Compliance (SOC).....................................................................................................................19

Appendix 3 Interface types, quantities and load................................................................................................................20

Appendix 4 Basic reports for KPIs and counters.................................................................................................................21

1

Page 2: Annex3 Technical Specification

2

Page 3: Annex3 Technical Specification

1. General requirements

Hardware and software components of the Network Quality of Service (QoS) monitoring system (hereafter SYSTEM) are intended for monitoring of signaling and data exchange as well as radio network performance in the network of “K-Telecom” CJSC and will be accommodated in c. Yerevan;

The core network elements are distributed between two different locations in c. Yerevan as shown in Appendix 1;

The radio network elements are collocated with core network elements as well as in remote regional sites;

The Contractor must ensure compatibility of the supplied system and its components with existing 2G, 3G and 4G (LTE) networks and corresponding interfaces, protocols;

The Contractor must have at least 3 years of proven experience in the field of monitoring systems integration into mobile operator networks and sufficient expertise in mobile networks audit;

Option of portable probes for signaling traffic capturing on remote locations should be provisioned (particularly for Abis and Iub monitoring);

Equipment must have 19 inch form factor and be installable in standard industrial racks; Offered equipment for traffic capture on network element interfaces and the diagram of

connections must be agreed with and approved by the Customer; Detailed cost table should be presented by the Contractor reflecting costs for equipment

(servers, probes, ports, cables, etc.), services (implementation, training, system expansion, licenses, post-warranty support, etc.), software applications, change requests implantation, etc.

The SYSTEM must be dimensioned with at least 30% spare capacity (including traffic capturing, processing, storage, etc.);

Taking into account the rapid growth of data services usage and consequent need of the SYSTEM expansion to handle increased load, the Contractor should present the SYSTEM upgrade scenario. The cost of upgrade must be reflected the cost table;

During the SYSTEM expansion and modernization, cost of the interfaces and licenses must be fixed as defined in the frame contract for equipment supply, in accordance with tender offer;

The Contractor can suggest project implementation scenario in phases depending on the availability of hardware or software functionality (based on roadmap), or other reasonable conditions. In this case the implementation period of each phase must be presented with detailed cost information;

The Contractor can suggest additional services or system components that can enhance the SYSTEM performance and overall network performance monitoring, reporting, analysis and troubleshooting process. The cost for enhancement implementation, services, and post-warranty terms must be specified explicitly;

Statement of Compliance (SOC) provided in Appendix 2 must be provided by the Contractor. Compliance of the offer to each item in SOC must be specified by the Contractor in terms “Noted”, “Compliant”, “Partially Compliant”, “Not Compliant”. Comments must be provided for the “Partially Compliant” and “Not Compliant” items. If the above mentioned statements are not presented for the specific point, then “Not compliant” statement will be applied for this particular requirement. The SOC will be used during the offer evaluation and later will be attached to the contract as a separate appendix.

All proposals presented within the frame of the current process shall include as a minimum: Official Technical Datasheets and Product Description information about presented

solutions. It shall contain all technical information for all the elements integrating the overall solution (Hardware platforms, products, network elements, SW, etc.);

3

Page 4: Annex3 Technical Specification

Generic Solution Architecture Diagrams, with the maximum level of detail in terms of architecture and interfaces;

Detailed roadmap of the solution and planned new products; References in terms of already operating solutions within the Industry; Acceptance & Testing Standard document; Training catalog; Optional Maintenance policy terms and conditions after the warranty period; Any other information that may be considered of relevance within the current RFP process.

2. Requirements to the Project implementation

Following actions should be performed by the Contractor before starting the Project implementation works:

Develop technical requirements specification of the Project based on the technical requirements of the Customer;

Develop and confirm with Customer the Project Implementation Plan (PIP). Following on the terms specified in the confirmed PIP is a mandatory condition. Penalties must be foreseen in the contract for the case of PIP terms violation;

Perform site survey on the sites where the equipment will be installed; Appoint a responsible specialist for project management, and oblige the manager to control

the follow-up on PIP terms and works implementation process as agreed with the Customer; The Contractor should provide responsibility matrix for the Project services, to be confirmed

with the Customer; The Contractor provides all necessary information for the equipment installation, powering

and integration including equipment components, size and weight, powering options, power consumption, heat dissipation, cooling mechanism, etc.

The Contractor ensures delivery of all required installation materials for the whole scope of Project implementation works. All the materials should be available on sites before the start of installation works.

3. Project services requirements

The implementation works duration for the SYSTEM installation, integration and configuration according to the Customer’s requirements (including configuration of KPIs, alarm thresholds, etc.) should not exceed two months from the date of equipment delivery;

The Contractor should present initial engineering data no later than 10 weeks in prior the works completion act signing date;

The Contractor provides the installation and integration works completion act within five days duration from the date of signing of the last Acceptance Test act;

All the works should be performed by a company having all proper licenses of the Republic of Armenia for corresponding works performance. The licenses should be valid for not less than 30 days after the works completion data as indicated in the PIP presented by the Contractor;

The specialists working on equipment powering should have proper certificates for operations with carriers up to 1000V;

The Contractor must provide all required information regarding the authorized subcontractor organizations involved in the project implementation works;

The Contractor bears all responsibility for the actions of subcontractor organization, authorized by the Contractor for the Project installation and integration works;

4

Page 5: Annex3 Technical Specification

All the expenses of the Contractor in the scope of Project realization works (services costs) should be included in the tender offer and reflected in the cost table;

The Contractor guarantees system integration works implementation without any impact (outage or degradation) on the Customer’s network;

4. Powering of the SYSTEM

It is preferred to use -48V DC power supply for the SYSTEM components; 230V AC power supply may be used upon necessity with allowed fluctuations in the range

215V…235V; The servers, probes and other components of the SYSTEM should have redundancy for power

supply. The equipment must be capable to function without any degradation in case of loss of any one direction of power supply.

Installation materials (power cable, cable terminals, fuses, breakers, etc.) for connection to the existing power supply system should be delivered before the start of installation works;

Provide information on equipment power consumption (servers, probes, TAPs, etc.).

5. Integration of the SYSTEM

The SYSTEM should have possibility of integration with OSS systems for Ericsson and Huawei equipment, with support of CORBA;

Signaling information storage servers of the SYSTEM should provide possibility of signaling information provisioning to information platforms from other vendors, which can be integrated in the Customer’s network.

6. Access to the SYSTEM

License for not less than 20 simultaneous users of the SYSTEM should be provided; All applications of the SYSTEM should support multiuser access with user rights

differentiation; SYSTEM access control mechanism should be implemented.

7. Administration of the SYSTEM

The SYSTEM should have convenient, intuitive and easy-to-use graphical interface for adjusting or changing all necessary parameters of the SYSTEM – threshold values, timers, prefixes, etc.

Possibility to have full network view on one screen; Possibility to configure user groups with corresponding access rules to predefined reports,

functions, etc.

8. Backup of the SYSTEM

The SYSTEM should support automatic full and incremental backup of configuration data and operation system according to the configurable time table;

The SYSTEM should support automatic backup of all indicators and KPIs according to the configurable time table;

The SYSTEM backup copies storage time should be not less than 60 days.

5

Page 6: Annex3 Technical Specification

9. Requirements to the documentation of the SYSTEM

At the end of project realization the Contractor provides full documentation of the SYSTEM in hard and electronic formats in English language. The completeness, composition and format of the documentation should be defined by the Customer.

The SYSTEM documentation should include: General description of the SYSTEM; Detailed description of the network part; Detailed description of the HW equipment part; Technical documentation on exploitation and configuration; Product description with detailed documentation on the SYSTEM structure, its logical

modules, description of internal and external interfaces, configuration rules and administration of the modules and interfaces;

Documentation on configuration and monitoring of alarm messages; Description of statistical information collection and analysis methods;

Reference documentation sufficient for the SYSTEM exploitation should be integrated into the SYSTEM.

10. Performance of the SYSTEM

Minimal storage time for all unprocessed data in signaling data capturing servers should be not less than seven days;

Minimal storage time for xDRs not less than 45 days; Processing capacity for load up to 0,4Erl/channel and up to 1Erl/channel in busy hour on E1

interface, and up to 1Gbps on Ethernet interface; The SYSTEM should have practical realization on mobile operator networks with subscriber

base not less than 2 000 000. Realization description and references should be provided; The SYSTEM should be scalable the way to enable further increasing of interfaces for data

capturing and processing; The SYSTEM should have distributed architecture with capability to install portable probes for

data capturing; All the relevant SYSTEM components should support centralized time synchronization for

correct time stamping of xDRs; Possibility to export xDRs to other platforms or external media; Flexible configuration of exported xDR fields and parameters.

11. Supported interface types

LSL/HSL on STM-1/SDH interface; Sigtran & VoIP Ethernet interface (100, 1000 Mbps copper and optical); 10 Gbps Ethernet optical interface; Frame Relay; PRI (Q.931); Information on interface connection type licensing (if applicabe) should be provided with

corresponding costs; Possibility of co-location of different interfaces inside one probe must be specified; The cost each interface should be fixed by mutual agreement of the Parties and should not be

increased during 10 years;

6

Page 7: Annex3 Technical Specification

Interface quantities, types and utilization are presented in the Appendix 3.

12. Supported interfaces

Information on licensing for any interface (if applicable) should be provided with corresponding costs;

Interfaces to be supported should include: A, C, D, E, F, Mc, Nc, Nb, Iub, IuCS, Gr, Gs, Gp. IuPS (Control Plane) Gb Frame Relay, Gb over IP Gn (GTP-С, GTP-U), Gi S1, S1AP, S6A, S10, S11, X2, SGi Abis over TDM, Abis over IP, Iub (Huawei, Ericsson). For Abis and Iub interfaces a solution with

portable probes should be provisioned, which could be fully integrated into monitoring and statistical systems to enable full correlation of signaling messages with the measurements data from the portable probes.

13. Supported protocols

Information on licensing for any protocol (if applicable) should be provided with corresponding prices;

Protocols to be monitored should include: Sigtran (SCTP, M2UA, M3UA, IUA, M2PA, SUA), MTP, SCCP, MAP (ver. 1, 2, 3), TCAP, DTAP, CAP (Phase 1, 2, 3, 4), BSSAP, BSSMAP, RANAP, ISUP, R-ISUP, SIP, BICC, H.248, INAP (Ericsson CS 1+), DNS, DHCP, RADIUS, DIAMETER, HTTP, SMPP 3.4/5.0; BGP (GRX links);

NBAP, LAPD.

14. “Protocol Analyzer”

Supported decoding protocols: NBAP, LAPD, BSSAP, BSSMAP, CAP ph1-4, DTAP, MAP v1, v2, v3, MEGACO (H.248), H.323, BICC, MTP2, MTP3, RANAP, SCCP, SIP, SIGTRAN (SCTP, M2UA, M2PA, M3UA, IUA, SUA), TCAP, DIAMETER, BGP (GRX links), SAAL, ALCAP, DNS, DHCP, RADIUS, HTTP, SMPP 3.4/5.0, ISDN-PRIISUP, ISUP-R2000, IUP/BTNUP, MGCP, R2-Signalling, RTCP, RTSP, RTP, UDP, TCP, IP (v4, v6), ICMP, ARP, BSSGP, LDAP, S1AP, GTP-U v1, GTP-C v2, X2AP, NAS;

Possibility to perform search in the signaling messages based on any field value (“Called Party Number”, “Calling Party Number”, “Original Calling Number”, “Redirecting Number”, A-IMSI, B-IMSI, etc.), time stamp of the signaling message, type of signaling message, protocol, etc.

Possibility to make combinations of different filters using Boolean functions “AND”, “OR”, “NOT”;

On-Line and Off-Line analysis modes availability; Support of signaling point code labels, not only OPC/DPC values; Possibility to save and load custom filters; Support of messages color coding (based on direction, protocol, etc.); Possibility to export data to TXT, CSV, XLS, etc. formats; Functionality of message correlation for any particular call or transaction; xDR viewing capability for any particular call; Delay in trace result viewing from the moment of signaling information receipt on the probes

should not be more than 30 seconds;

7

Page 8: Annex3 Technical Specification

Possibility to switch from Protocol Analyzer view to Call Trace view; Possibility to use the full functionality of Protocol Analyzer by several users simultaneously; Interface types are presented in Appendix 2.

15. “Call Trace”

Possibility to perform search in the signaling messages based on any field value (“Called Party Number”, “Calling Party Number”, “Original Calling Number”, “Redirecting Number”, A-IMSI, B-IMSI, cause, etc.), time stamp of the call attempt, call answer, disconnection, call duration, etc. Possibility to make combinations of different filters using Boolean functions “AND”, “OR”, “NOT”;

On-Line and Off-Line analysis modes availability; Support of signaling point code labels, not only OPC/DPC values; Possibility to save and load custom filters; Possibility to export data to TXT, CSV, XLS, etc. formats; Graphical representation of the messages of a call of transaction (message flow chart); GIS integration for Abis and Iub signaling messages mapping, possibility of interaction with

Google Earth; Functionality of correlation of signaling data from different interfaces relating to one call or

transaction; Functionality of cross-protocol correlation; Functionality of data correlation between LTE, 2G and 3G networks; Possibility to switch to signaling tracing mode; Possibility to view messages of all logical layers above physical; IMSI-TMSI correspondence for the subscribers registered in the network; Maximum number of simultaneous call trace tasks supported by the system should be

specified.

16. “Network Performance Monitoring”

On-Line and Off-Line modes of network performance analysis (quantity of different messages, number of errors, rejects, success rates, etc.), statistics, monitoring of a set of signaling channels, separate channels, signaling point;

Flexible monitoring time intervals – 5, 15, 30, 60 min. Viewed information filtering possibility; Possibility to view information in graphical as well as table formats; Possibility to export information; Possibility to perform network KPI decomposition to network elements KPI level (drill down); Possibility to switch to call trace or protocol analyzer modes for detailed analysis.

17. “Roaming and interconnect”

On-Line and Off-Line modes of monitoring; Statistics for inbound and outbound roamers; Monitoring on the level of country and operator (prefixes, GTs, etc.); Statistics of events, messages and main KPIs; Data export functionality; Configurable measurements time intervals – 15 min, 60 min, 24 hr; Data sorting and filtering functionality;

8

Page 9: Annex3 Technical Specification

Graphical reporting of statistical and qualitative figures; Possibility to configure counters for SCCP messages for inter-operator exchange; Counter for inter-operator MSU exchange; Possibility to configure anchors for MSISDN, IMSI, IP address, SCCP GT to specific operators; Possibility to perform KPI decomposition to network elements KPI level (drill down); Possibility to switch to call trace or protocol analyzer modes for detailed analysis; Possibility to export data.

18. “Reporting”

Following reporting functionality should be supported by the SYSTEM: Statistics based on any field of xDR records, with possibility to apply filters and build graphs; xDR specification with corresponding descriptions of all fields should be provided; Reports based on:

Counters (i.e. number of call attempts); Defined ratios (i.e. ASR); Statuses;

Possibility to create custom reports using counters, KPIs and save them as templates; Possibility to configure KPIs aggregation (hourly, daily, weekly, monthly, etc.); Possibility to modify KPI formulas and add new KPIs and reports; Availability of logical, mathematical and date functions; Time interval for updating the report (15 min, 60 min, 24 hr, month) must be configurable for

each report; GUI interface for creating custom KPIs with the use of counters and formulas; Possibility to integrate reference data (i.e. user equipment specifications); Thresholds definition for counters and KPIs (to define degradation, partial or full

unavailability); Availability of reports for radio conditions (coverage) and capacity analysis for 2G, 3G and 4G

(LTE) networks including: Cell neighboring relations analysis; Cell coverage and load analysis; HSDPA/HSUPA performance and mobility analysis; HSPA+, DC (Dual Carrier), MIMO analysis;

Integration with geo location applications (or integrated GIS) for radio measurements and KPIs visual mapping with serving cells and sites;

Automatic report updating and distributing (via email) functionality; Availability of standard reports for all data types available to a user. The list of these reports

should be provided; Possibility to use graphical as well as table format reports; Possibility to create different types of graphs – linear, pie charts, histograms/bar charts in

combination of 2G, 3G and 4G (LTE) data; Possibility to create comparative reports with graphs for different data types; Possibility of generating the reports using:

Search; Filtering; Sorting; Grouping; Time (relative, absolute);

9

Page 10: Annex3 Technical Specification

Value filtering for including or excluding defined values; Parallel working (simultaneous viewing or working with several reports); Best and worst KPIs;

Report planning functionality. Scheduled sending of reports to email addresses: Information panel – dashboard creation possibility, which will include a set of monitored KPIs

with possibility of further detailing; Monitored KPI aggregation possibility on different levels:

On network element level (MSC. BSC, etc.) Geographical, can be based on external DB or file (i.e. cells cluster, BSC/RNC clusters, etc.); Network level – 2G, 3G, 4G; Subscriber group (postpaid, prepaid, etc.); Terminal equipment model and type;

Possibility to control graph axis parameters. By default X axis should be the time; Possibility to switch to trending view (comparison with previous reporting periods results on

the same graph); Drill down functionality to switch from KPI reporting mode to KPI decomposition and down to

call trace mode; All the KPIs and counters that will not be implemented in supplied software version and will

be available in the future, should be provided to the Customer free of charge; Quality measurements should be implemented according to the ITU-T Q.752 and E.422

recommendations; Reporting for protocols S1AP, GTPv2; Configured reports for the KPIs and counters requested the Customer including the ones

defined in Annex 4; Reporting for USSD transactions:

Statistics on USSD requests, request codes; Flexible options for filtering on USSD code fields values; Statistics on USSD request processing results (successful, fail, error, unknown service, etc.); USSD response message body analysis;

Report exporting functionality including XLS, SCV, PDF, HTML, JPEG formats; Access to all performance indicators used in KPI composition; Reference data availability for all KPIs and timers; Storage terms for KPIs:

Hourly KPIs – 45 days; Daily KPIs – 6 months; Weekly KPIs – 1 year; Monthly KPIs – 3 years;

Any limiting factor in the Reporting system should be specified (i.e. max number of reports created, max number of custom KPIs supported, max number of defined thresholds, max storage time, etc.).

19. “GPRS” measurement mode

Possibility to perform search in the signaling messages based on any field value (MSISDN, IMSI, URL, APN, USER IP, disconnection cause, etc.), time stamp of the session activation attempt, disconnection, session duration, etc.

Possibility to make combinations of different filters using Boolean “AND”, “OR”, “NOT” functions;

10

Page 11: Annex3 Technical Specification

Protocol decoding functionality on interfaces: Gb, Gr, Gs, Gn, Gi, Gp, IuPS; Raw signaling storage time not less than 7 days; On-Line and Off-Line modes availability; Custom filters saving and loading functionality; Data export functionality (TXT, CSV, XLS, HTML, etc.); Message correlation functionality for any given transaction or call; User plane monitoring and analysis on Gn interface (including RTT, retransmission rate and

other related measurements); Analysis possibilities based on URL, APN, user agent, user application, user IP address/range,

service type, etc.

20. Geo location

Functionality to enable geo location of the network events using signaling information on NE interfaces;

User position definition algorithm accuracy (in meters) must be specified; Full integration into monitoring and reporting system with support of drill down functionality; Easy switching to call trace, protocol analyzer and reporting views; Functionality of KPIs mapping on physical map (RSCP levels, setup inefficiency, drops, HO

success rate, call density, pilot pollution, etc.); Possibility to apply filters on mapped data/KPIs (subscriber groups, time interval, etc.); Reports/maps exporting functionality.

21. Marketing specialized reporting

Following reporting functionality should be supported by the SYSTEM: Customer equipment benchmarking; Customer applications usage statistics; Customer services usage statistics; DPI data analysis:

Visited URLs Protocols used Applications used

Customer generated traffic, its composition by customer equipment, application, service, URL, etc.;

Customer behavior in terms of device usage (analysis based on IMEI, MSISDN, IMSI); ADMS features:

Device vendor, model Browser info Operating system Service supporting info (e.g. video call, MMS, etc.);

Duration stats (session, call); Location stats (cell ID with map overlaying); Latency info; Average throughput; Total bandwidth utilized; Peak and off-peak info (voice, data); APNs load statistics;

11

Page 12: Annex3 Technical Specification

APN usage stats; Possibility to apply filters (date, time, duration, etc.); Possibility to create custom reports and save them as templates; Possibility to create different types of graphs – linear, pie charts, histograms/bar charts in

combination of 2G, 3G and 4G (LTE) data; Possibility to create reports with comparative graphs for different data types; Possibility of report viewing with following functionality:

Search Filtering Sorting Grouping Time (relative, absolute) Value filtering for including or excluding defined values; Parallel working (simultaneous viewing or working with several reports); Best and worst KPI

Monitored KPI aggregation possibility on different levels; Possibility to switch to trending view (comparison with previous reporting periods results on

the same graph); Drill down functionality to switch from KPI reporting mode to KPI decomposition view; Report exporting wide functionality including XLS, SCV, PDF, HTML, JPEG formats.

22. Customer Care specialized tool

Requirements for Voice services reporting: Availability of search functionality using IMSI, MSISDN, IMEI, etc. Customer device/phone model and type identification; Reference data availability for user equipment (capabilities, supported standards, modes,

etc.); Activity start & end time, total duration in seconds; Traffic case name (originating or terminating); Called number network identification (home network or international destinations); Called number mobile operator identification (based on external reference data); Charging category description (on net calls, PSTN, etc.); Integration with charging/billing platform for price plan identification, charged amount

definition, balance before/after processed activity; In case of free call/SMS reason’s visibility (hot line, from available any free airtime or bonuses,

etc.); GSM number’s current status identification both for prepaid and postpaid; Transaction cell and site identification; Network type 2G, 3G, LTE and used service type (GPRS, EDGE, HSDPA, HSPA+, WCDMA, LTE)

identification; Transaction/activity final status (failed, error, success); In case of originating SMS check & note existence of SMSIW agreement, third part carrier

(based on external reference data); Reporting for USSD transactions:

Statistics on USSD requests, request codes; Flexible options for filtering on USSD code fields values; Statistics on USSD request processing results (successful, fail, error, unknown service, etc.);

12

Page 13: Annex3 Technical Specification

USSD response message body analysis;Requirements for Data services reporting:

Availability of search functionality by IMSI, MSISDN, IMEI, etc. Customer device/phone model and type identification; Reference data availability for user equipment (capabilities, supported standards, modes,

etc.); Session duration in seconds; Serving cell and site identification; Serving APN identification; User browser identification; Visited URL identification; IP address identification (real, dynamic, etc.); Activity start time & end time; Total traffic/UL+DL KB; Mean throughput on DL (Kb/S); Mean throughput on UL(Kb/S); Average Latency; Current Latency; Possibility of integration with charging/billing platforms for balance identification before/after

processed activity; GSM number’s current status identification both for prepaid and postpaid; GSM number Price Plan identification; Serving network type 2G, 3G, LTE (GPRS, EDGE, HSDPA, HSPA+, WCDMA, LTE); Quality of Experience evaluation; Data products specific price plan (PP) details should be taken into account in order to have

correct statistical data interpretation, since there are some restrictions, special requirements and privileges which are applied on monthly basis (high traffic packages, speed limitations, etc.);

Device Management: Identification of customer device vendor, model, IMEI, used APN, OS; Reference data availability for user equipment (capabilities, supported standards, modes,

MMS & GPRS capable, streaming, video call, PTT capable, etc.); Visited web sites analysis; Availability of search functionality by IMEI, IMSI, MSISDN; Total traffic/UL+DL KB; Mean throughput DL(Kb/s); Mean throughput UL(Kb/s); Integration option with ADMS platform for provisionign of MMS/GPRS configuration

information via this interface; Reports generation capability based on devices vendors, models, etc.;

VOIP services reporting: All options listed above for Voice services; Called numbers’ mobile operator and country identification; Dialed number formula checking (with prefix 77 or not); Possibility to check & indicate existence of VOIP agreement to the called direction (reference

data importing interface should be foreseen);Roaming (Inbound, Outbound):

Availability of search functionality by IMSI number, MSISDN, IMEI;

13

Page 14: Annex3 Technical Specification

Device vendor and model identification; OS identification; Activity start time & end time; Activity duration in sec.; Host mobile operator indication, availability of reference data regarding theexistence of

Roaming agreement with the particular operator; Identification of destination number network (home network or international destinations); Destination numbers’ mobile operator identification (based on reference data); Session duration in seconds; Used APN; Used browser identification; Requested URL identification; Total traffic/UL+DL KB Mean throughput DL (Kb/s) Mean throughput UL (Kb/s) Possibility to import references data regarding existing current roaming agreements with

other operators; Possibility to monitor Welcome message receipt for outbound roamers (welcome messages

are sent from our network); VIP customer care

Support of VIP customer lists/groups based on MSISDN, IMSI, IMEI; Special interface for constant monitoring of each VIP customer/group KPIs (voice and data

separately) with alarming capability in case of KPI degradation; Easy navigation to other reporting tools.

Reporting Flexible solution for trending reports generation based on different filtering/grouping criteria –

PP, equipment vendor and model, visited URLs, service type, cell ID, etc; Flexible report period adjustment capability – 15 min, 60 min, 24 hr, etc.; Report exporting capability in graphical as well as table formats;

Customization of user interface including but not limited to the monitored KPIs list, reports, graphs, lists, user interface organization should be foreseen during the SYSTEM adaptation and testing period. The term and conditions for customization services should be specified.

23. Alarm reporting

The SYSTEM should support following alarm representation possibilities: Several classes of alarms severities (minimum 3); Color coding of alarm messages based on alarm severity; Maximum delay of alarm reporting to user interface from the moment of meeting alarm

triggering condition – 5 seconds;The SYSTEM should support following possibilities of alarm messages configuration and reporting:

Possibility to create alarm messages and triggering conditions based on any available or custom created KPI;

Unique identifier existence for each alarm message; Alarm message resetting possibility in case of solving alarm triggering problem; Alarm message body configuration possibility; Functionality of alarm triggering thresholds configuration based on values set for each

indicator:

14

Page 15: Annex3 Technical Specification

Threshold for counters values; Threshold for counter or indicator ratio; Threshold for the deviation value of a counter or indicator from defined normal behavior

pattern (i.e. day/night pattern); Availability of standard predefined alarm messages and possibility to configure all alarm

message fields; Possibility to create and use different threshold values for different periods, days (seasonal

thresholds); Possibility to reflect following fields in the alarm message:

Alarm rising time; Alarm clearing time; Alarm severity; Text message (including the triggering condition); Alarm number; Alarm repeat counter; Comments (to be filled by the user/operator); Handling suggestions (to be configurable by the operator or administrator); Each change in the alarm state should fixed and brought to the operator attention;

Alarm short and detailed views availability; Possibility to initiate SMS or email sending upon triggering event (configurable); Alarm exporting functionality to other (umbrella) monitoring system; Detection and alarm generation in case of fault or loss of connection with any part (HW or

SW) of the SYSTEM or detection of problems on traffic capturing ports; Detection and alarm generation in case of loss of a capturing port, protocol or particular NE

messages (based on functional network topology); Alarm messages storage time in the SYSTEM should be not less than 6 months; Any limiting factors in Alarm reporting system should be specified (i.e. max number of

stored/raised alarms, custom created alarms, configurable thresholds, etc.).

24. Network topology

The SYSTEM should have network topology visualization tool for network elements and corresponding connections mapping. Whereas:

Automatic discovery and identification of new added elements based on SPC and/or IP address;

Automatic discovery of connections/links between network elements; Grouping functionality of different logical elements with different SPC codes; Flexible updating of NE labels based on SCP and/or IP address; Visualization of alarm status of links and NEs; Network topology and links manual editing possibility; Reference data availability for network elements with corresponding SPCs, IP addresses, etc.

25. Warranty and service terms

Warranty for all hardware and software components of the system should be not less than 3 years;

15

Page 16: Annex3 Technical Specification

Technical support for the SYSTEM should be available during 365 days per year, 24 hours a day. Technical problems neutralization and resolution terms will depend on the problem severity and priority and need to explicitly specified in the SLA;

Post-warranty support of the SYSTEM (all components) should be not less than 7 years; Post-warranty service cost will be defined in the frame contract and is not subject to be

increased later; Post-warranty service terms and conditions need to presented (including contract template)

with detailed cost table and payment terms; The Contractor will supply the latest software release officially available for deployment; In the warranty period the Contractor will ensure delivery and installation of all new software

releases and upgrades to the SYSTEM for improvement of performance, and ensures compatibility of new software with existing hardware parts;

Provide the periodicity and approximate cost of software upgrades for post warranty period; In the warranty period the Contractor will bear responsibility for free of charge repair (or

replacement) of the hardware equipment or its parts, software upgrades, discovered software and hardware defects elimination;

Terms for SYSTEM change requests implementation concerning the customization or changes in the user interface and system behavior should be specified;

The Contractor will provide the procedure for sending faulty equipment for repair and receiving the repaired ones;

The Contractor will provide the Technical Assistance Center (TAC) contacts and interaction procedure;

The Contractor will provide remote technical assistance through VPN connection; The Contractor must provide the cost of post warranty support in the costs table; The Contractor shall evaluate and provide the list of spare parts with corresponding

quantities to ensure uninterrupted operation of SYSTEM; Roadmap of the products and services should be presented including future software and

hardware releases, implemented protocols, applications, tools, etc.; Optionally annual network technical audit can be offered by the Contractor. In this case

network performance assessment criteria should be specified in the offer. In the outcome following points must be included:

oPresentation of network performance audit report with description of performed measurements and methodology;

o Evaluation of results and identification of network performance degradations, bottlenecks and deviations from normal/common behavior;

oRecommendations for improvement and optimization.

26. System acceptance

A fully integrated and configured system should be presented for acceptance, including KPI reports configuration specified in Appendix 4;

Acceptance test should be performed by the Contractor representative in presence of the specialists from “K-Telecom” CJSC;

Acceptance test cases and scenarios should be presented by the Contractor and approved by the Customer;

Based on acceptance test results the Contractor makes a Final Acceptance act.

16

Page 17: Annex3 Technical Specification

27. Training

Available trainings catalog must be provided by the Contractor; Training of 4 specialists for system administration level. The Contractor will provide the list of

required trainings (architecture, functional description, development, administration, exploitation servicing), suggested locations and include it in the technical and commercial offer;

Training of 20 specialists for system operator level; The Contractor will bear all the expenses for the Customer specialists training (travel,

accommodation, visa expenses, etc.). The cost of required training must be included in the offer.

28. SYSTEM management

The platform should have management system with support of following modules: Configuration module; Statistics collection module; Protocol analyzer module; Call trace module; Roaming module; System monitoring module (CPU load, memory usage, etc.); Alarm module with mandatory support of SNMP; Remote administering.

29. Fault tolerance

The platform should ensure the performance of main/key functions according to the following normative:

Signaling messages capture and analysis: 99.97% of time Availability of the SYSTEM: 99.97% of time

30. Security

Security configuration options should be foreseen in the SYSTEM to limit access based not only on authentication (username/password), but also based on IP address.

31. Monitoring center implementation

An optional offer for video-wall set-up can be made for visualization of monitoring system’s output (dashboards, trend reports, etc.).

17

Page 18: Annex3 Technical Specification

Appendix 1: “K-Telecom” CJSC Core network topology

18

Page 19: Annex3 Technical Specification

Appendix 2: Statement of Compliance (SOC)

19

Page 20: Annex3 Technical Specification

Appendix 3 Interface types, quantities and load

Interface Port type Number of Ports Mean load (total) Peak load (totoal)SIGTRAN (SCCP, MAP, CAP, BSSAP, BSSMAP, RANAP, ISUP, SIP, BICC, etc.) 1G electrical 4* 100 Mbps 200 MbpsGn (CP+UP) 10G optical 2 2.5 Gbps 3 Gbps

Gi (CP+UP) 1G electrical10G optical

22 2.5 Gbps 3 Gbps

Gb FR STM1 optical 2 70 Mbps 100 MbpsGb IP 1G electrical 4 50 Mbps 90 MbpsIu-PS (CP + UP) 1G optical 18 2.3 Gbps 3 GbpsS1 1G optical 2 200 Mbps 1 GbpsSGi 1G electrical 2 200 Mbps 1 GbpsAbis IP** 1G electrical 2 200 Mbps 400 MbpsIub IP** 1G optical 2 700 Mbps 1 GbpsAbis TDM** STM1 optical 2 200 Mbps 300 MbpsIub ATM** STM1 optical 2 200 Mbps 300 Mbps

* Two ports in site Yerevan 1, two ports in site Yerevan 2** Abis and Iub information is provided for dimensioning purposes for one controller with up to 120 BTS (more than 2000 TRXs) and 120 NodeBs configured.

20

Page 21: Annex3 Technical Specification

Appendix 4 Basic reports for KPIs and counters

2G VoiceCall Setup Success Rate 5DAVTCH Blocking Rate BH 5DAVDrop Call Rate 5DAVPagingSSS SUCCESS (Switch Subsystem Success Rate) Unsuccessful Calls directed to international operatorsUnsuccessful calls directed to local operators Drop Call Defects Cells Rate

3G VoiceCall Setup Success Rate UTRANBlok Sp Rate UTRANDrop Sp Rate UTRANSSS SUCCESS (Switch Subsystem Success Rate) Unsuccessful Calls directed to international operatorsUnsuccessful calls directed to local operators PagingDrop Call Defects Cells RateLocation Update success RateCSSR Defects Cells RateBlock TCH Defects Cells RateHR Defect Cells RateCSSR Defects Traffic RateBlock TCH Defects Traffic RateDrop Call Defects Traffic RateHR Defects Traffic RateEquipment DowntimeCSSR Video UTRANBlok Video Rate UTRANDrop Video Rate UTRAN

Roaming KPIROAMING ASRFOREIGN ASRTRANSIT ASRROAMING NERFOREIGN NERTRANSIT NERMER

21

Page 22: Annex3 Technical Specification

MER UL Location Update

Voice and Video TrafficSUM LOAD BSCTCH_Traffic_BH_5DAVTCH_Traffic_5DAVTRAFF_SPEECHTRAFF_VIDEO

2G DataPS Attach Success RateGPRS PDP context activation Success RateTBF Establishment Success RateTBF Drop Rate All CauseTBF Establishment Fail Rate due to congestionUser Data Throughput TBF Average ULUser Data Throughput TBF Average DLDetach Success RateIntra SGSN RAU Success RateInter SGSN RAU Success Rate2G CDR (Cells Rate non-fulfilling the requirements)2G CDTR (Traffic Rate in cells non-fulfilling the requirements)2G PS Setup Time GPRS Time Delay Rate2G Mean Throughput UL 2G Mean Throughput DL

3G DataCSSR RRC (Connection Setup Success Rate)Drop RRC Rate3G PS Blok Rate3G PS Success Rate3G PS Attach Success Rate3G PDP context activation Success RateDL Data R99 throughput at BHDL Data HSDPA throughput at BH3G PS Drop Data Rate3G PS Detach Success Rate3G Intra SGSN RAU (Routing Area Update) Success Rate3G CDR (Cells Rate non-fulfilling the requirements)3G CDTR (Traffic Rate in cells non-fulfilling the requirements)IRAT HO PS OUTHSDPA CH Success Rate

22

Page 23: Annex3 Technical Specification

3G PS Setup Time3G PS Mean Throughput UL 3G PS Mean Throughput DL 3G PS Mean Throughput UL HSPA 3G PS Mean Throughput DL HSPA R99 Time Delay RateHSPA Time Delay RateHSPA Retransmission RateR99 Retransmission Rate

Data TrafficTotal GPRS DL TrafficTotal GPRS UL TrafficTotal 3G DL TrafficTotal 3G UL TrafficR99 Data DL TrafficHSPA Data DL Traffic

LTEControl Plane KPIAttachAttach request Attach accept Attach completeAttach success rate Attach Accept rateAttach completion rateHO X2Ho request HO request ack HO complete (sur X2 ue cxt release) HO cancel preparation phase HO failure preparation phase HO cancel completion phase HO Completion phase failure due to Treloc Expiry HO preparation success rate HO completion success rate HO success rate Tracking area updateTA update request TA update request with S1 context TA update Accept TA Update reject TA update fail TA update success rate

23

Page 24: Annex3 Technical Specification

TA update preparation Success rate TA update Completion success rate User Plane KPIServices Traffic loadService Type: "DNS", "FTP", "HTTP", "MMS-HTTP", "MMS-WAP", "Other PS", "POP3", "SMTP",

"Streaming" or "WAP"Total IP volume (DL + UL) (GB)DL Volume (GB)UL Volume (GB)Traffic load (%)URLNumber of 1st page downloadsNumber of objects on 1st pageAverage duration of 1st page download (sec)Average duration of PDP activation and 1st page download (sec)Rate of PDP activation and 1st page download over 10sProtocolTraffic distributionService Type: "DNS", "FTP", "HTTP", "MMS-HTTP", "MMS-WAP", "Other PS", "POP3", "SMTP",

"Streaming" or "WAP"Protocol name (HTTP, HTTPS, FTP, FTP-DATA, MIC-DS, NETBIOS…)Total IP volume exchanged (UL+DL) (GB)

Radio QoSAbis KPISDCCH CongestionImmediate Assignment EfficiencyTCH Assignment EfficiencyIncoming HO EfficiencyRX Lev before call DropsRX Qual/TA before call DropsRX Lev before HORX Qual/TA before HOCall drop causesCell metrics per RXlevDL Quality per RX LevUL Quality per RX LevLink Balance per DL RX LevLink Balance Distribution and RxQualCell metrics per TATiming Advance DistributionRX Level per Timing AdvanceRX Level PC Compensated per Timing AdvanceRX Quality per Timing AdvanceLink Balance per Timing AdvanceTCH/Call drops per Timing AdvanceSDCCH Statistics per Access Delay

24

Page 25: Annex3 Technical Specification

Immediate Assignment Failures per Access DelayLocation Update Failures per Access DelayMO SMS Failures per Access DelayMT SMS Failures per Access DelayNEIGHBOURHOOD statisticsNeighborhood statisticsNeighborhood OptimizationHourly statisticsSDCCH CongestionSDCCH trafficTCH trafficCapture CheckCapture ConsistencyRRC connection setup inefficiency

Iub indicatorsRRC connection setup inefficiencyDrops of connections in CELL_DCHDrops of connections in CELL_FACHDrops of connections in Compressed ModeRadio Link Synchronization problemsRadio Link Setup failure ratesRadio Link Setup failure causesRadio Link Addition failure ratesRadio Link Addition failure causesSynchronized Radio Link Reconfiguration failuresRadio Link Reconfiguration failure causesActive set life duration and sizeCells characteristics statistics (Ec/No at connection request; Ec/No vs distance at connection

request; RRC connection success rate vs Ec/No; Distance; SIR target; UL BLER; Transmitted code Power, etc.)

Neighbor set statistics (3G/2G HO per 3G cell; 3G/2G HO per 2G cell; 3G neighbor cells per couple; 3G candidate cells for a best server; 3G best servers for a candidate cell; 2G Neighboring per 3G/2G cells couples; 2G Neighboring for 3G cell; 3G Neighboring for 2G cell)

RLC DATA Round Trip TimeRNC RLC DATA latencyHSPA Radio Bearer Setup EfficiencyCell_ FACH to Cell_DCH channel type switching efficiencyHSPA Mobility EfficiencyHSPA StabilityHSPA Mobility Profile

25