Ankit Alankar ETP

16
A PRESENTATION ON EFFLUENT TREATMENT PLANT [E.T.P.] R.R. AUTONOMOUS COLLEGE ALWAR BARMALT MALTING INDIA PVT. LTD. KESHWANA , JAIPUR SUBMITTED BY ANKIT B.Sc. BIOTECH 3 rd YEAR ROLL NO. : 1353001

Transcript of Ankit Alankar ETP

Page 1: Ankit Alankar ETP

A PRESENTATION

ON EFFLUENT TREATMENT PLANT [E.T.P.]

R.R. AUTONOMOUS COLLEGE

ALWAR

BARMALT MALTING INDIA PVT. LTD.

KESHWANA , JAIPUR

SUBMITTED BY

ANKIT

B.Sc. BIOTECH 3rd YEAR

ROLL NO. : 1353001

Page 2: Ankit Alankar ETP

INTRODUCTION OF ETP

ETP IS THAT PROCESS IN

WHICH WE TREAT

EFFLUENT WATER .

WE REMOVE IMPURITIES

THE BACK UP OF TANKS.

Page 3: Ankit Alankar ETP

NEED OF ETP

Water is basic necessity of life used for

many purposes one of which is industrial

use.

Industries generally take water from rivers

or lakes but they have to pay heavy taxes

for that.

So its necessary for them to recycle that to

reduce cost and also conserve it.

Page 4: Ankit Alankar ETP

DESIGN BASIS

1. RAW WATER CHARACTERISTICS:-

The system based on the following

incoming waste water analysis.

S l. No. PARAMETER UNIT VALUE

1. Flow rate m3 1500

2. COD mg/L 4000-5000

3. BOD mg/L 3000-3500

4. TDS mg/L 1000-1500

5. PH S.U. 4 - 6

Page 5: Ankit Alankar ETP

2.EXPECTED TREATED WATER

CHARACTERISTICS :-

The treated waste water from Effluent

treatment plant shall meet the following

parameters after treatment.SI. Nos. PARAMETER

S

UNIT VALUE

1. Flow Rate m3/d 1500 (less due to sludge

generation)

2. COD mg/L < 250

3. BOD mg/L < 20

4. TDS mg/L < 10

Page 6: Ankit Alankar ETP

TREAMENT SCHEME AND PROCESS OF ETP

The ETP treat the waste water generated from company.

1. Raw water collection tank 2. Screen3. Equalization tank

4. AHR5. Biogas system including flare ignition6. Aeration tank

7. Lamella tank8. Final outlet

Page 7: Ankit Alankar ETP

RAW WATER TANK

EFFLUENT TANK

INEFFLUENT TANK WE COLLECTE THE COMPANY WASTE WATER.

IN THIS TANK ,AIR IS PRODVIDED FOR HOMOGENIZATION OF INCOMING EFFLUENT.

TO PREVENT THE SENDIMATION

Page 8: Ankit Alankar ETP

EQUALIZATION TANK

IN EQUALIZER TANK ,AIR IS PRODVIED FORHOMOGENIZATION OF INCOMING EFFLUENT THROUGHT COARSE AND FINE SCREEN.

IN EQUALIZER TANK ,EQUALIZE THE ALL WATER BY AIR BLOWER .

Page 9: Ankit Alankar ETP

AHR TANK

ANAEROBIC HYBRID REACTOR

IN AHR TANK WE PROVIDE

THE WATER IN THE ABESENSOXYGEN.

IN AHR TANK THREE PROCESSARE COMPLETE

1. HYDROLYSIS2. ACIDFICATION2.METHANE FORMATION

Page 10: Ankit Alankar ETP

THERE IS SOME MICROORGANISM ALSO

USE IN

AHR PROCESS

1. BACTERIA

2. ROTIFERS

3. VIRUSES

4. PROTOZOVA

5. FUNGI

6. ALGAI

Page 11: Ankit Alankar ETP

AERATION TANK

REDUCE THE RESIDUAL COD& BOD LOAD FROM THE WASTEWATER AEROBIC BIOLOGICAL PROCESS AND ACHIEVEDTHE FINAL CREATED WASTE WATER.

ACTIVATED SLUDGE PROCESSBASED BIOLOGICAL IS PROVIEDTHROUGH WHICH ORGANIC SUPENDED SOLID & DISSOLVEDSOLID.

Page 12: Ankit Alankar ETP

LAMELLA CLERIFER TANK

LAMELLA CLERIFER IS AWASTE WATER TREATMENTPROCESS THAT FEATURE A RACK OF INCLINED PLATESWHICH CAUSE SETTLING OF FIOCCULATED MATERIALFROM WATER THAT FLOWSACCROS THE PLATES

THE AEARTED MIXTURE,RICH IN FLOCS, IS FORWARDEDTO THE LAMELLA CLERIFER TANK.

Page 13: Ankit Alankar ETP

FINAL TANK

IN THIS TANK EFFLUENT WASTE WATER

COMPLETED TREATED TAKE

FINAL OUT LET .

CHECK THE ALL PARAMETERS

Page 14: Ankit Alankar ETP

WATER ANALYSIS

TREATED WATER CHARACTERISTICS

:-

The treated waste water from Effluent

treatment plant shall meet the following

parameters after treatment.SI. Nos. PARAMETER

S

UNIT VALUE

1. Flow Rate m3/d 1500 (less

due to sludge

generation)

2. COD mg/L < 250

3. BOD mg/L < 20

4. TDS mg/L < 10

Page 15: Ankit Alankar ETP

SAFETY PRECAUTION

Protective clothing, rubber boots, gloves for

the hands.

Personal should be a aware of the character

of the acid and their hazards.

Goggles must always be worn during the

corrosive acids.

Smoking or naked lights should be prohibited

in the vicinity of vessels containing acid.

Page 16: Ankit Alankar ETP