    Save time and money.Check the Troubleshooting list. This section helps stepyou through some common problems that might occur. Ifyou do need service, help is only a phone call away. CallFrigidaire Customer Services at 1-800-944-9044.

    Product RegistrationRegistering your product with Frigidaire enhances ourability to serve you. You can register online atwww.frigidaire.comor by dropping your ProductRegistration Card in the mail.

    The serial plate is on the left side of the range hood

    Record model & serial numbers here

    Purchase date

    Model number

    Serial number

    PRODUCT RECORD AND REGISTRATION

    CONTENTSImportant Safety Instructions ............................... 3List of materials ................................................... 5

    Electrical requirements ......................................... 5Location requirements .......................................... 6Product dimensions .............................................. 6Venting Requirements .......................................... 7Prepare the location ............................................. 8Install Range Hood (Ducted version) ..................... 10Make Electrical Connection .................................... 12Installing Range Hood (Recirculating version) ......... 13Range Hood Use .................................................. 14Range Hood Care ................................................. 14Troubleshooting ................................................... 16Warranty Information ........................................... 17

    Be sure to visit us online atwww.frigidaire.com

    for a complete line of accessories.

    Thank you for choosing Frigidaire.

    This Use & Care Guide is part of our commitment tocustomer satisfaction and product quality throughout theservice life of your new appliance.We view your purchaseas the beginning of a relationship. To ensure our ability tocontinue serving you, please use this page to recordimportant product information.

    Need help??

    Visit the Frigidaire web site at www.frigidaire.comBefore you call for service, there are a few things you cando to help us serve your better.

    Read this Use & Care manual.It contains instructions to help you use and maintain yourrange properly.

    If you received a damaged range Hood...immediately contact the dealer (or builder) that sold youthe range hood.

    Serial PlateLocation

    Remove the grease lter and the left side panel

  • 7/26/2019 Ancona Range Hood

    3/13

    3

    Save these instructions for future references

    Approved for residential appliances

    For residential use only

    Do not attempt to install or operate your appliance untilyou have read the safety precautions in this manual.Safety items throughout this manual are labeled with aWARNING or CAUTION based on the risk type.

    This is the safety alert symbol. It is used to alert you topotential personal injury hazards. Obey all safety mes-sages that follow this symbol to avoid possible injury ordeath.

    WARNING

    This symbol alerts you to situations that maycause serious body harm, death or propertydamage.

    CAUTION

    CAUTION indicates a potentially hazardoussituation which, if not avoided, may result in

    minor or moderate injury.

    IMPORTANT

    IMPORTANT indicates installation, operation,maintenance or valuable information that is not hazardrelated.

    IMPORTANT SAFETY INSTRUCTIONS

    CAUTION

    FOR GENERAL VENTILATING USE ONLY. DO NOTUSE TO EXHAUST HAZARDOUS OR EXPLOSIVEMATERIALS OR VAPORS.

    IMPORTANT SAFETY INSTRUCTIONS

    Read all instructions before using this appliance.

    WARNING

    TO REDUCE THE RISK OF FIRE, ELECTRICSHOCK, OR INJURY TO PERSONS, OBSERVE THEFOLLOWING:

    Use this unit only in the manner intended by themanufacturer. If you have questions, contact themanufacturerBefore servicing or cleaning the unit, switch poweroff at service panel and lock service paneldisconnecting means to prevent power frombeing switched on accidentally. When the servicedisconnecting means cannot be locked, securelyfasten a prominent warning device, such as a tag, to

    the service panel.Installation Work and Electrical Wiring Must Be DoneBy Qualied Person(s) In Accordance With allAplicable Codes & Standards, Including Fire-ratedConstruction.Sufcient air is needed for proper combustion and exhausting of gases through the ue (Chimney) of fuelburning equipment to prevent back- drafting. Followthe heating equipment manufacturers guideline andsafety standards such as those published by theNational Fire Protection Association (NFPA), theAmerican Society for Heating, Refrigeration and AirConditioning Engineers (ASHRAE), and the local code

    authorities.When cutting or drilling into wall or ceiling, do notdamage electrical wiring and other hidden utilities.Ducted systems must always be vented to theoutdoors.

    A.

    B.

    C.

    D.

    E.

    F.

    CAUTION

    To reduce risk of re and to properly exhaustair, be sure to duct air outside - do not vent ex-haust air into spaces within walls, ceilings,attics, crawl spaces, or garages.

    WARNING

    TO REDUCE THE RISK OF FIRE, USE ONLY METALDUCT WORK.Install this hood in accordance with all requirementsspecied.

  • 7/26/2019 Ancona Range Hood

    4/13

    4

    WARNING

    TO REDUCE THE RISK OF INJURY TO PERSONS,IN THE EVENT OF A RANGE TOP GREASE FIRE,OBSERVE THE FOLLOWING:

    SMOTHER FLAMES with a close - tting lid, cookiesheet, or other metal tray, then turn off the gasburner or the electric element.

    BE CAREFUL TO PREVENT BURNS.If the ames donot go out immediately, EVACUATE AND CALL THEFIRE DEPARTMENT.

    NEVER PICK UP A FLAMING PAN - you may beburned.DO NOT USE WATER, including wet dishcloths ortowels - a violent steam explosion will result.Use an extinguisher ONLYif:

    You know you have a class ABC extinguisher,and you already know how to operate it.The re is small and contained in the areawhere it started.The re department is being called.You can ght the re with your back to an exit.

    OPERATIONAlways leave safety grills and lters in place.Withoutthese components, operating blowers could catch ontohair, ngers and loose clothing.The manufacturer declines all responsibility in theevent of failure to observe the instructions given herefor installation,maintenance and suitable use of the

    product. The manufacturer further declines all respon-sibility for injury due to negligence and the warranty ofthe unit automatically expires due to improper mainte-nance.

    a)

    b)

    c)

    d)

    1)

    2)

    3)4)

    IMPORTANT SAFETY INSTRUCTIONS

    WARNING

    To Reduce The Risk Of Fire Or Electric Shock, DoNot Use This Hood With Any External Solid StateSpeed Control Device.

    WARNING

    TO REDUCE THE RISK OF A RANGE TOP GREASEFIRE.

    Never leave surface units unattended at highsettings. Boilovers cause smoking and greasyspillovers that may ignite. Heat oils slowly on low ormedium settings.Always turn hood ON when cooking at high heat orwhen ambeing food (l.e. Crepes Suzette, Cherries

    Jubilee, Peppercorn Beef Flambe).Clean ventilating fans frequently. Grease should notbe allowed to accumulate on fan or lter.Use proper pan size. Always use cookwareappropriate for the size of the surface element.

    a)

    b)

    c)

    d)

  • 7/26/2019 Ancona Range Hood

    5/13

    5

    LIST OF MATERIALS

    LIST OF MATERIALS

    Parts included in your hood4 - 0.45 x 1.3 cm mounting screws2 - .35 x .65 cm rectangular vent transition

    mounting screws2 - .29 x .65 cm round metal mounting platemounting screws3 x 10 (8.3 x 25.4 cm) rectangular metal ventsystem.7 (17.8 cm) round metal mounting plate.

    Parts Needed2 - UL listed wire connectorsWall or roof cap with damper to match vent systemVent clamps/duct tape as requiredUL listed or CSA approved strain relief

    Tools/Materials required

    Drill1 (3.0 cm) drill bit (0.3 cm) drill bit for pilot holesPencilWire stripper or utility knifeTape measure or rulerCaulking gun and weatherproofcaulking compoundFlat-blade screwdriverPhillips screwdriverSaber or keyhole saw

    For cabinets with recessed bottoms:Two - 2 (5.1 cm) wide ller strips. Length andthickness determined by recess dimensions.Four at head wood screws or machine screwswith washers and nuts (to attach ller strips).

    ELECTRICAL REQUIREMENTS

    Observe all governing codes and ordinances.Ensure that the electrical installation is adequate and inconformance with National Electrical Code, ANSI/NFPA

    70 (latest edition), or CSA Standards C22.1-94, CanadianElectrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-tion) and all local codes and ordinances.If codes permit and a separate ground wire is used, it isrecommended that a qualied electrician determine thatthe ground path is adequate.A copy of the above code standards can be obtainedfrom:

    National Fire Protection AssociationOne Batterymarch Park

    Quincy, MA 02269CSA International

    8501 East Pleasant Valley RoadCleveland, OH 44131-5575

    A 120 volt, 60 Hz., AC only, 15-amp, fused electricalcircuit is required.If the house has aluminum wiring, follow theprocedure below:

    Connect a section of solid copper wire to thepigtail leads.Connect the aluminum wiring to the addedsection of copper wire using special conectors and/or tools designed and UL listedfor joining copper to aluminum.

    Follow the electrical connector manufacturers recom-

    mended procedure. Aluminum/copper connection mustconform with local codes and industry accepted wiringpractices.

    Wire sizes and connections must conform withthe rating of the appliance as specied on themodel/serial rating plate.The model/serial plate is located on the left side ofthe range hood.Wire sizes must conform to the requirements ofthe National Electrical Code, ANSI/NFPA 70 (laest edition), or CSA Standards C22. 1-94, Canadan Electrical Code, Part 1 and C22.2 No. 0-M91(latest edition) and all local codes and ordinances.

    1.

    2.

  • 7/26/2019 Ancona Range Hood

    6/13

    6

    IMPORTANT

    Observe all governing codes and ordinances.It is the installers responsibility to comply with

    installation clearances specied on the model/serialrating plate. The model/serial rating plate is locatedinside the range hood on the left side (See page 2for location). Range hood location should be awayfrom strong draft areas, such as windows, doors andstrong heating vents.Cabinet opening dimensions that are shown mustbe used. Given dimensions provide minimumclearance. Consult the cooktop/range manufacturerinstallation instructions before making any cutouts.Grounded electrical outlet is required. SeeElectrical Requirements section.All openings in ceiling and wall where canopy hood

    will be installed must be sealed.

    For Mobile Home InstallationsThe installation of this range hood must conform to theManufactured Home Construction Safety Standards, Title24 CFR, Part 328 (formerly the Federal Standard forMobile Home Construction and Safety, Title 24, HUD, Part280) or when such standard is not applicable, the stan-dard for Manufactured Home Installation 1982 (Manu-factured Home Sites, Communities and Setups) ANSIA225.1/NFPA 501A, or latest edition, or with local codes.

    Cabinet Dimensions

    A. 66 (167 cm) suggested min. - top of range hood to floor.B. 30 (76.2 cm) min. cabinet opening width for 30 (76.2 cm)models and 36 (91.4 cm) min. cabinet width for 36 (91.4 cm)models.C. 13 (33.0 cm) cabinet depthD. 36 (91.4 cm) base cabinet height

    LOCATION REQUIREMENTS

    PRODUCT DIMENSIONS

    A

    B

    C

    D

    hood model Dim A Dim B

    FHWC3040

    30 models

    30 (76.2 cm) 69/16 (16.7 cm)

    FHWC3640

    36 models

    36 (91.44 cm) 9 (24.3 cm)

    3 (8.25cm)

    10 (25.4cm)

    1 (2.5cm)typical both sides

    9 (22.9cm)typical both sides

    193/4(50.2cm)

    7/8(2.2cm)

    7/8(2.2cm)

    415/16(12.5cm)

    1 (3.8cm)typical both sides

    DIM B

    DIM A

    1 (4cm)recirculating cover

    7 (17.8cm

    9 (24cm)recirculating cover

    9/16(1.4cm)

  • 7/26/2019 Ancona Range Hood

    7/13

    7

    Vent system must terminate to the outdoors.Do not terminate the vent system into an attic or otherenclosed area.Do not use a 4 (10.2 cm) laundry-type wall cap.Use a 3 x 10 (8.3 x 25.4 cm) rectangular or 7 (17.8cm) round metal vent. Rigid metal vent is recommended.Plastic or metal foil vent is not recommended.The length of vent system and number of elbowsshould be kept to a minimum to provide efcientperformance.

    For the most efcient and quiet operation:Use no more than three 90 elbows.Make sure there is a minimum of 24 (61 cm) of straightvent between the elbows if more than 1 elbow is used.Do not install 2 elbows together.Use clamps or duct tape to seal all joints in the

    vent system.The vent system at exit must have a cold air damper.Use caulking to seal exterior wall or roof openingaround the cap.Best performances are reached with straight piping,without elbows and using smooth pipe.Maximum recomended vent system length: 35 ft (10.7m).

    Cold Weather InstallationsAn additional back draft damper should be installed tominimize backward cold air ow and a thermal breakshould be installed to minimize conduction of outside tem-peratures as part of the vent system. The damper should

    be on the cold air side of the thermal break.The break should be as close as possible to where thevent system enters the heated portion of the house.

    Makeup AirLocal building codes may require the use of makeup airsystems when using ventilation systems greater thanspecied CFM of air movement. The specied CFM variesfrom locale to locale. Consult your HVAC professional forspecic requirements in your area.

    Venting MethodsVent system can terminate either through the roof or wall.

    Use 3 x 10 (8.3 x 25.4 cm) rectangular with a maximumvent length of 35 ft (10.7 m) or 7 (17.8 cm) round vent witha maximum length of 50 ft (15.2 m) for vent system.

    NOTE

    Flexible vent is not recommended. Flexible ventcreates both back pressure and air turbulencethat greatly reduce performance.

    Calculating Vent System LengthTo calculate the length of the system you need, add theequivalent feet (meters) for each vent piece used in thesystem.

    7 (17.8 cm) Round Vent System

    Vent Piece

    90 elbow 5.0 ft(1.5 m)

    7 (17.8 cm) wall cap 0.0 ft (0.0 m)

    Example Vent System

    A

    B

    C

    A

    B

    C

    A. 3 x 10 (8.3 x 25.4 cm)rectangular or 7 (17.8 cm)round vent through theroof. (purchased separately)

    B. Roof cap with damper(purchased separately)

    C. 24 (61.0 cm) min. to 30(76.2cm) above the cookingsurface

    A. 3 x 10 (8.3 x 25.4 cm)rectangular or 7 (17.8 cm)round vent through thewall or out the top(purchased separately)

    B. Wall cap with damper (purchased separately)C. 24 (61.0 cm) min. to 30

    (76.2cm) above the cooking

    surface

    Roof Venting Wall Venting

    Maximum Recommended Length = 50 ft (15.2 m)

    1 - 90 elbow = 5.0 ft (1.5 m)8 ft (2.4 m) straight = 8.0 ft (2.4 m)1 - wall cap = 0.0 ft (0.0 m)

    Length of 7 (17.8 cm) system = 13.0 ft (3.9 m)

    2 ft (0.6 m)

    7 (17.8 cm) round90 elbow

    6 ft (1.8 m)Wall Cap

    VENTING REQUIREMENTS

  • 7/26/2019 Ancona Range Hood

    8/13

    8

    PREPARE THE LOCATION

    NOTE

    Before making cutouts, make sure there isproper clearance within the ceiling or wall.

    Disconnect power.Select a at surface for assembling the range hood.Place covering over that surface.Lift the range hood and set it upside down onto coveredsurface.If cabinet has recessed bottom, add wood ller stripson each side. Install screws to attach ller strips inlocations shown.

    Determine Wiring Hole LocationDetermine and clearly mark a vertical centerline onthe wall and cabinet bottom.

    1.2.

    3.

    4.

    1.

    A

    A Centerline

    VENTING REQUIREMENTS

    3 x 10 (8.3 cm x 25.4 cm) Vent System

    Vent Piece

    3 x 10 (8.3 cm x 25.4 cm) 5.0 ft90 elbow (1.5 m)

    3 x 10 (8.3 cm x 25.4 cm) 12.0 ftflat elbow (3.7 m)

    3 x 10 (8.3 cm x 25.4 cm) 0.0 ftwall cap (0.0 m)

    Example Vent System

    Maximum Recommended Length = 35 ft (10.7 m)

    1 - 90 elbow = 5.0 ft (1.5 m)8 ft (2.4 m) straight = 8.0 ft (2.4 m)1 - wall cap = 0.0 ft (0.0 m)

    Length of 3 x 10 = 13.0 ft (3.9 m)(8.3 cm x 25.4 cm) system

    2 ft(0.6 m)

    3 x 10(8.3 x 25.4 cm)

    elbow 6 ft (1.8 m)

    Wall Cap

    Wood filler strips(recessed cabinetbottoms only)

    Wall

    Cabinetbottom

    3 (7.6 cm)

    3 (7.6 cm)

    A. 4 flat head wood screws withwashers and nuts

    AA

  • 7/26/2019 Ancona Range Hood

    9/13

    9

    To wire through top:Mark a line distance (A) from the right of thecenterline on the underside of the cabinet. Mark thepoint on this line that is 78 (2.2 cm) from back wall.Drill a 1 (3.2 cm) diameter hole (B) through thecabinet at this point.

    To wire through wall:Mark a line distance (A) from the right of thecenterline on the underside of the wall. Mark the pointon this line that is 78 (2.2 cm) from the underside ofthe cabinet. Drill a 1 (3.2 cm) diameter hole (B)through the rear wall at this point.

    VENTINGChoose venting exhaust discharge from the variousoptions listed - Style 1 - 4 that follows:

    Style 1 - Recirculating Hood versionFor this installation, go to Install Range Hood(recirculating version) on page 13.

    2.

    1.

    A

    Centerline

    78 (2.2 cm)from wall,not cabinet frame

    B

    hood

    model

    Dim

    A

    30 & 36

    models

    88(21.3 cm)

    A

    A Centerline

    78(2.2 cm)

    hood

    model

    Dim

    A

    30 & 36

    models

    88(21.3 cm)

    B

    Style 2 - Cut Openings for 3 x 10 (8.3 cm x25.4 cm) Rectangular Vent System

    Roof VentingTo make a 4 x 10 (10.16 cm x 26.7 cm) rectangularcutout on the underside of cabinet top and bottom:

    Mark lines (1.3 cm) and 4 (12.1 cm) from theback wall on the centerline of the underside of cabinet.Mark lines 5 (13.3 cm) to the right and left of thecenterline on the underside of cabinet.Use saber or keyhole saw to cut a rectangular openingfor vent.Repeat steps 1-3 for the underside of the top of thecabinet.

    Wall VentingTo make a 3 x 10 (8.9 cm x 26.7 cm) rectangle inthe wall:

    Make 2 lines by measuring (0.9 cm) and 3(9.8 cm) down from underside of cabinet and mark onthe centerline on the back wall.Mark lines 5 (13.3 cm) to the right and left of thecenterline on the wall.Use saber or keyhole saw to cut a rectangular openingin the wall for the vent.

    1.

    2.

    3.

    4.

    1.

    2.

    3.

    Cabinet cutouts

    *From wall, not cabinet frame

    *1/2(1.3 cm)

    51/4

    (13.3 cm)51/4

    (13.3 cm)

    *43/4

    (12.1 cm)

    Cabinet

    front

    Centerline

    51/4

    (13.3 cm)

    378

    (9.8 cm)

    38(0.9 cm)

    51/4

    (13.3 cm)

    Centerline

    PREPARE THE LOCATION

  • 7/26/2019 Ancona Range Hood

    10/13

    10

    Install Vent SystemInstall vent through the vent opening in upper cabinetor wall. Complete venting system according to theselected venting method. See Venting Requirementssection.Use caulking to seal exterior wall or roof openingaround the cap.

    INSTALL RANGE HOOD(Ducted version)

    NOTE

    Your model includes a 3 x 10 (8.3 x 25.4 cm)rectangular transition and a 7 (17.8 cm) round

    vent mounting plate inside the package.

    Detach the 3 x 10 (8.3 x 25.4 cm) rectangular and 7(17.8 cm) round vent from the package.Unpack the one you have chosen and set the other in asafe place.

    1.

    2.

    1.

    PREPARE THE LOCATION

    Style 3 - Cut Openings for 3 x 10 (8.3 x 25.4cm) Rectangular Vent Transition to Round Vent

    Roof VentingTo make a circular vent opening on the underside of thecabinet top:

    Mark a centerline on the underside of the top of cabinet.Mark a line 5 (12.7 cm) from the back wall on theunderside of the top of cabinet.Use a compass or a circle template to draw a circle witha diameter of 7 (19 cm).Use saber or keyhole saw to cut the circular ventopening.

    Style 4 - Cut Openings for 7 (17.8 cm) Round Ventto Round Vent Transition

    Roof Venting

    To make a circular vent opening on the underside of thecabinet top:

    Mark a centerline on the underside of the top of cabinet.Mark a line 5 (12.7 cm) from the back wall on theunderside of the top of cabinet.Use a compass or a circle template to draw a circle witha diameter of 7 (19 cm).Use saber or keyhole saw to cut the circular vent opening.Repeat steps 1-3 for the underside of the top of thecabinet.

    1.2.

    3.

    1.2.

    3.

    4.

    *From wall, not

    cabinet frame

    *5

    (12.7 cm)Cabinet

    cutouts

    7

    (19 cm)

    Centerline

    *From wall, not

    cabinet frame

    *5

    *

    *

    (12.7 cm)Cabinet

    cutouts

    * 7

    (19 cm)

    Centerline

    A. 3 x 10 (8.3 x 25.4 cm) rectangular vent damper

    B. 7 (17.8 cm) round vent mounting plate

    A

    B

  • 7/26/2019 Ancona Range Hood

    11/13

    11

    Vent Connector InstallationInstall 7 (17.8 cm) round vent mounting plate or 3 x10 (8.3 x 25.4 cm) vent connector, depending on yourvent system installation. Attach to range hood using theindicated screws provided in hardware kit.

    NOTE

    The 7 (17.8 cm) round vent mounting plate orthe 3 x 10 (8.3 x 25.4 cm) rectangular ventconnector can be installed up to 1 (2.5 cm) oneither side of the hood center to accommodateoff center ductwork.

    If a vent damper is installed with a wall cap withdamper, check that they do not interfere with each

    other. Remove the vent connector damper ap ifthey interfere.

    Power Supply Cable InstallationFor direct wire installations, run the home powersupply cable according to the National Electric Codeor CSA standards and local codes and ordinances.There must be enough wiring from the fused disconnect(or circuit breaker) box to make the connection in thehood electrical terminal box.

    1.

    Lift the range hood up under cabinet and determinenal location by centering beneath cabinet. Mark onthe underside of cabinet the location of the 4 keyholemounting slots on the range hood (See slot dimensionson page 6). Set range hood aside on a covered surface.

    Use 8 (3 mm) drill bit and drill 4 pilot holes as shown.NOTE: Make the drill holes on the thin area of the slot.

    Install the 4 - .45 cm x 1.3 cm mounting screws inpilot holes. Leave about (6.4 mm) space betweenscrew heads and cabinet to slide range hood into place.

    For roof installations, remove the top rectangular orround vent knockout depending on which vent system

    you desire to install. For wall installations, remove therear rectangular vent knockout.

    2.

    3.

    4.

    A

    A. Keyhole slot

    A

    4(6.4 mm)

    A

    A. Drill pilot hole

    A

    BA. Top rectangular knockout

    B. Rear rectangular knockout

    C. Top round knockout

    C

    A

    C

    D

    B

    C

    B

    A

    A

    B

    Install the 3 x 10 (8.3 x

    25.4 cm) rectangular vent

    transition

    A. 3 x 10 (8.3 x 25.4 cm)

    rectangular vent transition

    B. .35 x .65 cm screws

    C. Rectangular vent knockouts

    INSTALLING THE HOOD

    Install the 7 (17.8 cm)

    round vent mounting plate

    A. .29 x .65 cm screws

    B. 7 (17.8 cm) round vent

    mounting plate.

    C. Round vent knockout

    D. Rectangular vent knockout

  • 7/26/2019 Ancona Range Hood

    12/13

    12

    1. Disconnect power.

    2. Use UL listed wire connectors and connect white wires(A) together.

    3. Use UL listed wire connectors and connect black wires(B) together.

    WARNING

    Fire HazardElectrically ground the blower. Use copper wire.Connect ground wire to green ground screw interminal box. Failure to do so can result in death,re, or electrical shock.

    4. Connect green (or bare) ground wire from power supplyto green ground screw in terminal box and securely tighten.

    5. Install terminal box cover.6. Install the 50W maximum halogen light bulb. See

    Replacing the halogen lamp in the Range HoodCare section.

    7. Reconnect power.

    Complete InstallationReplace the two bottom panels.Replace grease lter if removed. See the Range HoodCare section.Check the operation of the range hood fan and light.See Range Hood Use section.

    If range hood does not operate, check to see whether acircuit breaker has tripped or a household fuse has blown.Disconnect power and check wiring connections.

    NOTE

    To get the most efcient use from your newrange hood, read the Range Hood Use section.

    1.2.

    3.

    NOTE

    Do not reconnect power until the installation iscomplete.Before starting the installation, remove thegrease lter, left and right side panelsComplete installation to reinstall the side panels.

    Remove the screw from theterminal box cover.Remove terminal box coverand set aside.

    Remove the power supply knockout from the topor rear of the vent hood (depending on the incominglocation of your home power supply cable) andinstall a UL listed or CSA approved strain relief.

    Using 2 or more people, lift the hood into nal position.Feed enough electrical wire through the UL listedor CSA approved strain relief to make connections inthe terminal box. Tighten the strain relief screws.Position the range hood so that the large end ofthe keyhole slots are over the mounting screws.Then push the hood toward the wall so that the screwsare in the neck of the slots. Tighten the mounting screws,making sure the screws are in the narrow neck of slots.Connect ventwork to hood. Seal joints with ventclamps or duct tape to make secure and airtight.Check that back draft dampers work properly.

    MAKE ELECTRICAL CONNECTION

    WARNING

    Electrical Shock HazardDisconnect power before servicing.Replace all parts and panels before operating.Failure to do so can result in death or electrical shock.

    2.

    3.

    4.

    5.

    6.

    7.

    A. Power supply

    knockout

    A

    A. Terminal box cover

    B. Screw

    A

    B

    INSTALLING THE HOOD

    A

    B

    C D

    E

    F

    G A.White wiresB. Black wiresC. UL listed wire connectorD. Green (or bare) ground wire

    E. Home power supply cableF. UL listed or CSA approved strain reliefG. Green ground screw

  • 7/26/2019 Ancona Range Hood

    13/13

    13

    INSTALL RANGE HOOD(Recirculating version)

    Lift the range hood up under cabinet and determine

    nal location by centering beneath cabinet. Mark onthe underside of cabinet the location of the 4 keyholemounting slots on the range hood (See slotsdimensions on page 6). Set range hood aside on acovered surface.

    Use 8 (3 mm) drill bit and drill 4 pilot holes as shown.NOTE: Make the drill holes on the thin area of the slot.

    Install the 4 - .45 cm x 1.3 cm mounting screws in pilot holes. Leave about (6.4 mm) space betweenscrew heads and cabinet to slide range hood into place.

    Power Supply Cable InstallationFor direct wire installations, run the home powersupply cable according to the National Electric Codeor CSA standards and local codes and ordinances.There must be enough wiring from the fused disconnect(or circuit breaker) box to make the connection in thehood electrical terminal box.

    NOTE

    Do not reconnect power until the installation iscomplete.

    Remove the screw from theterminal box cover.Remove terminal box coverand set aside.

    1.

    2.

    3.

    1.

    2.

    4(6.4 mm)

    A

    A. Drill pilot hole

    Remove the power supply knockout from the topor rear of the vent hood (depending on the incominglocation of your home power supply cable) andinstall a UL listed or CSA approved strain relief.

    Using 2 or more people, lift the hood into nal position.Feed enough electrical wire through the UL listedor CSA approved strain relief to make connections in

    the terminal box. Tighten the strain relief screws.Position the range hood so that the large end ofthe keyhole slots are over the mounting screws.Then push the hood toward the wall so that the screwsare in the neck of the slots. Tighten the mounting screws,making sure the screws are in the narrow neck of slots.

    Recirculation Vent CoverFor installations which are recirculating the air exhaust,the recirculation vent cover must be removed.Remove the recirculatingvent cover by removingthe 2 mounting screws

    with a phillips screwdriver.

    NOTE: For installationswhich are venting outthe roof or wall, therecirculating vent covermust remain in place.Do not remove as unitwill not perform properly.

    To complete the installation, go to Make Electrical

    Connection section on page 12.

    3.

    4.

    5.

    Part being removed

    A

    A. Power supply

    knockout

    A. Terminal box cover

    B. Screw

    A

    B

    A

    A. Keyhole slot

    A

    INSTALLING THE HOOD