Analisis Anclas de Gas 2007 Podio
-
Upload
ferchocaceres -
Category
Documents
-
view
13 -
download
2
description
Transcript of Analisis Anclas de Gas 2007 Podio
-
Copyright
by
Ochiagha Victor Ananaba
2007
-
Experimental Study On The Effect Of The Internal Design On The
Performance Of Down hole Gas Separators
by
Ochiagha Victor Ananaba, B.Eng.
Thesis
Presented to the Faculty of the Graduate School of
The University of Texas at Austin
in Partial Fulfillment
of the Requirements
for the Degree of
MASTER OF SCIENCE IN ENGINEERING
The University of Texas at Austin
December 2007
-
Experimental Study On The Effect Of The Internal Design On The
Performance Of Down hole Gas Separators
Approved by Supervising Committee:
Augusto L. Podio (Supervisor)
Paul Bommer
-
Dedication
To God Almighty.
To my loving and supporting parents Sir Emeka & Lady Nnenne Ananaba.
To my siblings, Nnem, Ugochukwu, Ugwunwanyi, Ogbugo & Amah (Papa).
To the woman that will be my wife.
-
v
Acknowledgements
I specifically want to thank my supervisor Dr. Augusto Podio for his continuous
support and encouragement through this research project. Under his supervision I have
greatly improved my knowledge and skills in the areas of petroleum production engineering
and artificial lift systems. It is an honor to have him as my supervisor and to be his friend.
I wish to thank Dr. Paul Bommer for the time that he took inside his very busy
schedule to read and review my thesis.
I will not forget to thank our Lab. Technician and my friend Tony Bermudez whose
support in maintaining and constructing my laboratory models made certain that I finished
my experiments in good time with high levels of accuracy.
I wish to thank Glenn Banm, Harry Linnemeyer, Ehiwario M., Acholem K., Ojifini
R., Elekwachi K. and Don Sorrell who were there to help whenever I needed assistance.
My special thanks go to our amiable graduate coordinator Cheryl Kruzie. I would not
be in UT if not for her kind and honest counseling.
Finally I would like to thank the companies that supported this research, Echometer
Company, ConocoPhillips, Yates Petroleum and Chevron. The comments and suggestions
from James McCoy, Lynn Rowland, John Patterson and Gabriel Diaz helped in shaping my
research.
I worked with Renato Bohorquez in the early days of this research and it was great.
Ochiagha Victor Ananaba
December 2007
-
vi
ABSTRACT
Experimental Study On The Effect Of The Internal Design On The
Performance Of Down hole Gas Separators
Ochiagha Victor Ananaba, M.S.E.
The University of Texas at Austin, 2007
Supervisor: Augusto L. Podio
The re-design of the internal geometry of static down hole gas separators directly
affects the gas liquid separation performance.
This thesis describes experimental results obtained after changing the dip tube design
from the conventional straight design to a helical design. Typically, a static down hole gas
separator with a conventional straight dip tube design depends on gravity to induce density
difference in the flowing wellbore fluid which causes gas liquid separation to occur. Thus,
the device is known as a gravity driven down hole gas separator.
-
vii
This research compared the experimental results and visual observations from
gravity driven down hole gas separators to that of static down hole gas separators with
helical dip tube designs known as static centrifugal down hole gas separators.
The visual observations showed that not only did the driving mechanisms for gas
liquid separation inside static centrifugal down hole separators include gravity it also
incorporated other means such as induced centrifugal forces that greatly improved overall
gas liquid separation. The 6 inch/second threshold downward superficial liquid velocity
generally regarded as the industry rule of thumb for down hole gas separators was
increased to 10 inch/second. In field units this is a 200 BPD increase in liquid production.
This research also studied the effect of increasing outer diameter of gravity driven
down hole gas separators from 3inches (2.75 ID) to 4inches (3.75 ID). The results
showed that liquid handling capacity increased by over 90% due to favorable flow regimes
observed inside the separator. However, critical examination of gas liquid separation
performances of both 3 inch OD and 4 inch OD separators in terms of downward liquid
superficial velocity reveal that gas liquid separation results are similar. It was concluded
therefore that downward superficial liquid velocity is a reliable parameter in the design of
down hole gas separators and that all gravity driven separators regardless of separator
outer diameter will operate in similar fashion except at different liquid flow rates.
Bubble rise experiment performed in this research project gave a range of 1 100 cp
as region of applicability for the results discussed in this thesis.
-
viii
Table of Contents
Acknowledgment v
Abstract...vi
List of Tables ........................................................................................................ xii
List of Figures ...................................................................................................... xiii
CHAPTER 1 1
Introduction ..............................................................................................................1 1.1 OBJECTIVE ..........................................................................................1 1.2 LITERATURE REVIEW ......................................................................3
1.2.1 PATENTED STATIC CENTRIFUGAL DOWN HOLE GAS SEPARATORS ...........................................................................15
1.2.1.1 GAS ANCHOR - PATENT No 3128719 .................................15 1.2.1.2 Continuous Flow Down hole gas separator for
Progressive Cavity Pumps - Patent No 5902378 .........................17 1.2.2 ACTIVE TYPE CENTRIFUGAL DOWN HOLE GAS
SEPARATORS ...........................................................................20 1.2.2.1 Liquid Gas Separator Unit - Patent No 3887342 .............20 1.2.2.2 Liquid Gas Separator Apparatus - Patent No 4481020 ...21 1.2.2.4 Apparatus for separating gas and solids from well fluids -
Patent No 6382317 B1 .................................................................24
CHAPTER 2 28
Experimental Facility And Procedure ....................................................................28 2.1 EXPERIMENTAL FACILITIES.........................................................28 2.2 DESCRIPTION OF EXPERIMENTAL FACILITIES .......................28 2.3 LABORATORY TEST WELL ............................................................32
2.3.1 LABORATORY INSTRUMENTS ............................................34 2.3.1.1 LIQUID FLOW MEASUREMENTS ................................34 2.3.1.2 GAS FLOW MEASUREMENT ........................................35
-
ix
2.3.2.2 PRESSURE MEASUREMENT ........................................37 2.4 EXPERIMENTAL PROCEDURE ......................................................38 2.5 SEPARATOR PERFORMANCE DISPLAY ......................................39 2.6 DOWN HOLE GAS SEPARATOR DESIGNS ..................................44
2.6.1 ECHOMETER (3X1), ECHOMETER (3X1.5), ECHOMETER (4x1), ECHOMETER (4X1.5), ECHOMETER (4X1.75) ..........44
2.6.2 PATTERSON (3X1), PATTERSON (3X1.5), PATTERSON (4x1), PATTERSON (4X1.5), PATTERSON (4X2) ..................47
2.6.3 TWISTER ...................................................................................48 2.6.3.1 ECHOMETER-TWISTER ..........................................52 2.6.3.2 PATTERSON TWISTER .........................................53
CHAPTER 3 55
Analysis Of Experimental Results .........................................................................55 3.1 EFFECT OF HELICAL DIP TUBE DESIGN ....................................55
3.1.1 PERFORMANCE RESULTS FOR THE TWISTER SEPARATOR .............................................................................56
3.1.2 PERFORMANCE RESULTS FOR ECHOMETER TWISTER SEPARATOR .............................................................................58
3.1.3 PERFORMANCE RESULTS FOR PATTERSON TWISTER SEPARATOR .............................................................................61
3.2 COMPARISON OF PERFORMANCES OF HELICAL DIP TUBE GAS SEPARATORS TO STRAIGHT DIP TUBE GAS SEPARATOR63 3.2.1 COMPARISON OF ECHOMETER-TWISTER AND
ECHOMETER (3X1) GAS SEPARATORS ..............................63 3.2.2 COMPARISON OF PATTERSON-TWISTER AND
PATTERSON (3X1) GAS SEPARATORS ...............................73 3.2.3 EFFECT OF THE NUMBER OF DIP TUBE TWISTS ON
STATIC CENTRIFUGAL SEPARATORS ...............................78 3.2.4 ANALYSIS OF STATIC CENTRIFUGAL SEPARATOR
DESIGNS. ...................................................................................84 3.3 EFFECT OF INTERIOR AND EXTERIOR FLOW AREAS ON
SEPARATOR PERFORMANCE ........................................................88 3.3.1 EFFECT OF CHANGING INTERIOR AND EXTERIOR
ANNULAR AREA FOR ECHOMETER GAS SEPARATORS90
-
x
3.3.2 EFFECT OF CHANGING INTERIOR AND EXTERIOR ANNULAR AREA FOR PATTERSON GAS SEPARATORS103
3.4 DIP TUBE LENGTH EFFECTS ..............................................116 3.5 PERFORMANCE OF ECHOMETER (3X1) GAS SEPARATOR
WITH STANDING VALVE INCLUDED BETWEEN GAS SEPARATOR AND TUBING RETURN LINE (PUMP INTAKE) .119 3.5.1 ECHOMETER (3X1) AND ECHOMETER (3X1) WITH
STANDING VALVE COMPARED. .......................................123 3.5.2 ANALYSIS OF PRESSURE DROP FOR ECHOMETER (3X1)
AND ECHOMETER (3X1) WITH STANDING VALVE ......125 3.6 FLOW REGIMES INSIDE THE DOWN HOLE GAS
SEPARATORS ..................................................................................126
CHAPTER 4 133
Bubble Rise Experiments .....................................................................................133 4.1 APPARATUS USED IN BUBBLE RISE EXPERIMENTS .............134 4.2 PROPERTIES OF FLUIDS USED IN THE EXPERIMENT ...........136
4.2.1 TEST FOR NEWTONIAN CHARACTERISTICS OF FLUIDS136 4.2.2 DETERMINING THE VISCOSITY OF TEST FLUIDS IN
ASSOCIATION WITH WATER AT ROOM TEMPERATURE138 4.2.2.1 TEST DATA FOR GLYCERIN IN ASSOCIATION WITH
WATER ....................................................................................139 4.2.2.2 TEST DATA FOR CORN SYRUP IN ASSOCIATION
WITH WATER .........................................................................140 4.3 ANALYSIS OF RESULTS FROM BUBBLE RISE EXPERIMENTS141
CHAPTER 5 145
Conclusions and Recommendations ....................................................................145 5.1 CONCLUSIONS...............................................................................145
5.1.1 CONCLUSIONS FROM COMPARISONS OF GRAVITY DRIVEN SEPARATORS AND STATIC CENTRIFUGAL GAS SEPARATORS .........................................................................146
5.1.2 THE EFFECT OF INCREASING SEPARATOR OUTER DIAMETER FOR GRAVITY DRIVEN SEPARATORS .......147
5.1.3 CONCLUSIONS FROM BUBBLE RISE EXPERIMENT ....149
-
xi
5.2 GENERAL DESIGN GUIDE ...........................................................149 5.3 RECOMMENDATIONS AND FUTURE WORK ..........................150
Appendix A ..........................................................................................................152
Schematics of the Echometer Separators .............................................................152
Appendix B ..........................................................................................................155
Schematics of the Patterson Separators ...............................................................155
Appendix C ..........................................................................................................159
Original data files .................................................................................................159
Nomenclature .......................................................................................................160
Abbreviations .......................................................................................................161
References ............................................................................................................163
Vita .165
-
xii
List of Tables
Table 2-1 - Sample Excel Spreadsheet for continuous flow test .......................................... 41
Table 2-2 Echometer gas separators configuration ............................................................ 44
Table 2-3 Patterson Separator Configuration ...................................................................... 46
Table 4-1 Dimensions of bubble rise experiment apparatus ........................................... 134
Table 4-2 Fluid Properties used in bubble rise experiment ............................................. 135
Table 4-3 Test data for glycerin in association with water ............................................... 138
Table 4-4 - Test data for corn syrup in association with water ....................................... 139
-
xiii
List of Figures
Figure 1-1 - Centrifugal Separator(Kobylinski et al) ................................................................ 8
Figure 1-2 - Gas flow through centrifugal separator (Kobylinski et al) ................................ 9
Figure 1-3 - Reverse-flow separator (Kobylinski et al) .......................................................... 10
Figure 1-4 Collar-Size down hole gas separator (McCoy and Podio10) ....................... 12
Figure 1-5- Down-hole gas separator (Patterson and Leonard11) ........................................ 14
Figure 1-6 - Jongbloed et al12 ..................................................................................................... 17
Figure 1-7 Static Centrifugal Separator by Obrejanu Marcel13 .......................................... 19
Figure 1-8 Invention by Bunnelle P14.................................................................................... 21
Figure 1-9 - Centrifugal Separator by Kobylnski et al ........................................................... 23
Figure 1-10 Invention by Powers Maston15 ......................................................................... 24
Figure 1-11 Invention by Delwin Cobb16 ............................................................................. 26
Figure 1-12 Cross section (3) in Figure 1-11 .................................................................... 26
Figure 2-1 Schematic of experimental test facility .............................................................. 30
Figure 2-2 Laboratory facility ................................................................................................. 30
Figure 2-3 Laboratory test well .............................................................................................. 31
Figure 2-4 Laboratory Well .................................................................................................... 32
Figure 2-5 Turbine flow meter and valve between pump and mixer ............................... 33
Figure 2-6 - - ITT Barton floco positive displacement meter .............................................. 34
Figure 2-7 - Fisher Porter Flow Rator tube ............................................................................. 35
Figure 2-8 - Thermodynamic Omega Air Flow Meter .......................................................... 36
Figure 2-9 - Sample Performance plot for Patterson (3X1) in continuous flow ............... 42
Figure 2-10 Echometer (3 X1.5) gas separator design ....................................................... 45
Figure 2-11- Echometer entry port geometry ......................................................................... 45
Figure 2-12 Echometer (4X1.75) gas separator design ...................................................... 45
Figure 2-13 4 inch OD Patterson Separator Design .......................................................... 47
Figure 2-14 3 inch OD Patterson Separator Design .......................................................... 47
Figure 2-15 Twister Separator (Bohorquez) ........................................................................ 50
Figure 2-16 Twister Connection ............................................................................................ 50
-
xiv
Figure 2-17 Diagrammatic of the forces acting in a static centrifugal separator ............ 51
Figure 2-18 Echometer - Twister .......................................................................................... 52
Figure 2-19 Patterson - Twister ............................................................................................. 53
Figure 3-1- Twister results in field units .................................................................................. 56
Figure 3-2 - Twister result in terms of superficial velocities ................................................. 57
Figure 3-3 Echometer - Twister result in terms of superficial velocities ......................... 58
Figure 3-4 Echometer - Twister results in field units ......................................................... 59
Figure 3-5 - Patterson - Twister result in terms of superficial velocities ............................ 60
Figure 3-6 - Patterson - Twister results in field units ............................................................. 61
Figure 3-7 Comparison of Echometer Twister and Echometer (3X1) results in terms
of superficial velocity .................................................................................................................. 64
Figure 3-8- Comparison of Echometer Twister and Echometer (3X1) results in Field
Units .............................................................................................................................................. 65
Figure 3-9 - Pressure Drop between the entry ports and pump intake for Echometer
Twister and Echometer (3X1); Casing Pressure (Pc) = 10 13psi ...................................... 66
Figure 3-10 Pressure measurements during the tests ......................................................... 67
Figure 3-11 Pressure drop for Echometer-Twister and Echometer (3X1) at constant
gas rates; Pc = 10 13 psi .......................................................................................................... 68
Figure 3-12- Pressure drop for Echometer-Twister and Echometer (3X1) at constant
liquid rates; Pc = 10 13 psi ...................................................................................................... 71
Figure 3-13 - Comparison of Patterson Twister and Patterson (3X1) results in terms of
superficial velocity ....................................................................................................................... 72
Figure 3-14 - Comparison of Echometer Twister and Echometer (3X1) results in Field
Units .............................................................................................................................................. 73
Figure 3-15 - Pressure Drop between the entry ports and pump intake for Patterson
Twister and Patterson (3X1) separators; Casing Pressure (Pc) = 10 13psi ...................... 74
Figure 3-16 Pressure drop for Patterson-Twister and Patterson (3X1) at constant gas
rates; Pc = 10 13 psi ................................................................................................................. 75
-
xv
Figure 3-17 - Pressure drop for Patterson-Twister and Patterson (3X1) at constant liquid
rates; Pc = 10 13 psi ................................................................................................................. 76
Figure 3-18 Patterson-Twister (2 twits) ................................................................................. 77
Figure 3-19 - Patterson Twister (2 twists) results in terms of superficial velocities ....... 78
Figure 3-20 - Patterson Twister (2 twists) gas separator results in field units ................ 79
Figure 3-21 - Comparison of Patterson Twister (4 twists) and Patterson Twister (2
twists) results in superficial velocity terms ................................................................................ 80
Figure 3-22 - Comparison of Patterson Twister (4 twists) and Patterson Twister (2
twists) results in Field Units ........................................................................................................ 81
Figure 3-23 - Pressure drop between the entry ports and pump intake for Patterson
Twister 2 twists and 4 twists gas separators; Casing Pressure (Pc) = 10 -13 psi.................... 82
Figure 3-24 Comparison of results for all static centrifugal separators in terms of
superficial velocities .................................................................................................................... 84
Figure 3-25 - Comparison of results for all static centrifugal separators in field units ..... 85
Figure 3-26 - Pump Liquid Fraction for Static Centrifugal Separators at 10 in/sec ......... 86
Figure 3-27 - Echometer (4X1) and Echometer (3X1) results compared in field units ... 90
Figure 3-28 - Echometer (4X1.5) and Echometer (3X1.5) results compared in field units
........................................................................................................................................................ 91
Figure 3-29 - Echometer (4X1.75) results in field units ........................................................ 93
Figure 3-30 Comparison of results of all Echometer gas separators in terms of
superficial velocity ....................................................................................................................... 94
Figure 3-31 - Pump Liquid Fraction for Echometer Separators at 6 in/sec ...................... 96
Figure 3-32 - Pump Liquid Fraction for Echometer Separators at 10in/sec ..................... 97
Figure 3-33 Comparison of all Echometer 4 inch OD separator results in field units . 98
Figure 3-34 - Pressure drop between the entry ports and pump intake for Echometer 4
inch OD gas separators for 2 phase gas liquid flow; Casing Pressure (Pc) = 10 -13 psi . 100
Figure 3-35 - Pressure drop between the entry ports and pump intake all tested
Echometer gas separators; Casing Pressure (Pc) = 10 -13 psi ............................................ 101
Figure 3-36 - Patterson (4X1) and Patterson (3X1) results compared in field units ....... 103
-
xvi
Figure 3-37- Patterson (4X1.5) and Patterson (3X1.5) results compared in field units .. 104
Figure 3-38 Patterson (4X1.75) results in field units ........................................................ 105
Figure 3-39 - Patterson (4X2) results in field units .............................................................. 106
Figure 3-40 - Comparison of results for all Patterson 3 inch OD and 4 inch OD
separators in superficial velocity terms .................................................................................. 107
Figure 3-41 - Pump Liquid Fraction for Patterson Separators at 6 in/sec ....................... 109
Figure 3-42 - Pump Liquid Fraction for Patterson Separators between 8 9 in/sec ..... 110
Figure 3-43 - Comparison of all Patterson 4 inch OD separator results in field units ... 112
Figure 3-44 Pressure Drop between the entry ports and pump intake for Patterson 4
inch OD gas separators; Casing Pressure (Pc) = 10 13psi ............................................... 113
Figure 3-45 - Pressure drop between the entry ports and pump intake for Patterson 4
inch OD gas separators at varying gas and liquid rates; Casing Pressure (Pc) = 10 -13psi
...................................................................................................................................................... 114
Figure 3-46 Comparison of results for Echometer (4X1.75) with 5dip tube and Echometer
(4X1.75) with 2 dip tube in superficial velocity terms ................................................................. 116
Figure 3-47 - Comparison of results for Echometer (4X1.75) with 5dip tube and Echometer
(4X1.75) with 2 dip tube in field units ...................................................................................... 117
Figure 3-48 Standing Valve Assembly ................................................................................ 119
Figure 3-49 SV joint Gas Separator Connection ........................................................... 119
Figure 3-50 Echometer (3X1) with SV result in terms of superficial velocities ........... 120
Figure 3-51 - Echometer (3X1) with SV result in field units .............................................. 121
Figure 3-52 Comparison of Echometer (3X1) with and without Standing Valve in terms
of superficial velocities ............................................................................................................. 122
Figure 3-53 - Comparison of Echometer (3X1) with and without Standing Valve in field
units ............................................................................................................................................. 123
Figure 3-54- Pressure drop between the entry ports and pump intake for Echometer
(3X1) with and without Standing Valve .................................................................................... 124
Figure 3-55 - Pressure drop between the entry ports and pump intake for Echometer
(3X1) with and without Standing Valve at varying gas and liquid rates; Pc = 10 -13 psi ... 125
-
xvii
Figure 3-56 Flow Regimes observed in the gas separator annular area
(courtesy Renato Bohorquez7) ................................................................................................. 126
Figure 3-57 Flow regime map for the annular space of 3 inch OD gravity driven gas separators7 127
Figure 3-58 Flow regime map for the annular space of 4 inch OD gravity driven gas separators .. 128
Figure 3-59 Flow regime map for the Twister separator annlus7 ................................... 130
Figure 3-60 Flow regime for Patterson Twister and Echometer Twister static
centrifugal separators ................................................................................................................ 131
Figure 4-1 Schematic of Laboratory Constructed Apparatus for testing bubble rise velocity ......... 134
Figure 4-4 Glycerin Rheology test ....................................................................................... 136
Figure 4-5 Glycol Rheology test .......................................................................................... 136
Figure 4-6 Corn Syrup Rheology test.................................................................................. 137
Figure 4-7 Viscosity plot for Glycerin in association with water at room temperature
...................................................................................................................................................... 138
Figure 4-8 Viscosity plot for Corn Syrup in association with water at room temperature
...................................................................................................................................................... 139
Figure 4-9 Combined viscosity plots for glycerin and corn syrup in association with
water at room temperature ...................................................................................................... 140
Figure 4-10 Examples of bubble diameter sizes measured.142 Figure 4-11 Mean bubble rise velocities in stationary liquid in an annulus ................... 143
-
1
Chapter 1
Introduction
1.1 OBJECTIVE
Most wells producing from mature reservoirs use artificial lift methods for oil
and gas production. Common artificial lift methods include beam pumping,
progressive cavity pumping and electric submersible pumping. All the mentioned
artificial lift systems exhibit a common problem: Gas Interference
The presence of free gas in beam pumps (sucker rod pumps) prevents the
traveling valve from opening at the appropriate time interval during the downstroke.
This is caused by the high compressibility of gas in the pump barrel. The traveling
valve may eventually open when the gas inside the barrel has been compressed
enough to overcome the fluid load on the plunger. In such a case fluid pound occurs.
In extreme cases the peak pressure of the trapped gas on the downstroke is
insufficient to overcome the hydrostatic head of the traveling valve; then the pressure
is not reduced enough on the upstroke to allow the standing valve to open and admit
new fluid. Both valves are essential stuck at a closed position and the pump refuses to
pump. This extreme case is known as gas locking.
In progressive cavity pumps (PCP) the produced liquid lubricates the rotor and
the stator so as to reduce the heat caused by friction. The presence of free gas in the
-
2
produced fluid reduces the lubricating function of the produced fluid so that the rotor
and stator are in direct contact. Temperature increase due to the direct contact causes
damage to the pump. In other cases gas in the produced fluid in PCP may change the
chemical composition of the elastomer in the stator of the pump which further
complicates the problem.
Electric submersible pumps (ESP) are typically used to handle high liquid flow
rates. Significant volumes of gas entering the pump especially at low intake pressures
degrade the pump performance, and dramatically reduce the head produced by the ESP.
This may prevent the pumped liquid from reaching the surface. The ESP is composed of
a down hole motor which is connected to a seal section which in turn is connected
to a centrifugal pump. It is imperative that the motor be cooled by the produced fluid
passing the outer casing. In the event that large quantities of gas pass the motor, the heat
transfer from the motor to the produced fluid will be drastically reduced, potentially
causing motor damage by overheating.
In all cases - beam pumps, PCP and ESP the pump volumetric efficiency is
reduced by the presence of gas. To combat the problem of reduced volumetric efficiency
and system damage down hole gas separators are used in conjunction with down
hole pumps.
The sole purpose of down hole gas separators* is to prevent gas from entering
into down hole pumps, or to at least reduce the quantity of gas entering into the pump
to permissible ranges where the pump efficiency is still acceptable.
Unfortunately many gas separator designs have not yielded the desired efficiency.
The widely used poorboy gas separator which depends on gravity segregation to
separate gas from liquids has become synonymous with inefficiency. * Down hole gas separators will mean the same thing as gas separators throughout this thesis
-
3
A thorough literature review on the subject of gas separator design was done to
study previous designs and relevant applications. Sources of information included
published technical papers, patents and thesis reports by Lisguiski, Guzman and
Bohorquez.
The scope of the present work emphasized the effect of the internal geometry
and induction of centrifugal forces on gas separator performance.
1.2 LITERATURE REVIEW
Schome 1 in February 1953 reported a field test of a down-hole gas separator in a
well in Utah. The pump volumetric efficiency obtained before the installation the down-
hole gas separator ranged between 26 and 48%. Schome1 reported that the efficiency was
increased to 70%; resulting in an increased production of 50BPD after the new gas
separator was installed. The author went on to describe some bottom-hole separator (as
it was then referred) designs and their mode of operation. All the separator designs
described in his paper depended on gravity segregation as the controlling mechanism for
efficient performance and were 30 40 ft long with 1inch suction tubes (dip tubes).
Schome1 noted that operators often faced retrieval problems when the separators were
plugged with formation debris. He attributed that to inconsistent installation techniques
and gas separator designs.
Clegg2 did a thorough review of the different types of gas anchors (down-hole
gas separators) and the principles that govern most of their operation. He pointed out
that the desire of several gas separator inventors was to achieve a downward mixture
-
4
velocity of 0.5ft/sec (6in/sec) inside the separator dip tube annular area. A downward
mixture velocity of 0.5ft/sec is generally accepted as being below the rising (slip) velocity
of gas in low viscosity fluids. Clegg2 and McCoy3 et al described the reasons for the
inefficiency of the commonest down-hole gas separator design the poorboy separator.
The reasons for the inefficiency of the Poorboy gas separator according to the author
included the high downward liquid velocity inside the Poorboy separator and size of its
dip tube ID which the author considered as too small in diameter. The small ID dip tube
often causes excessive pressure drop inside the separator. The Shell (Schmit Jongbloed)
gas anchor formula:
gas anchor efficiency = 0.66 0.5100
(1 )wf slC P V+
1
Pwf= intake pressure at the anchor; Vsl=downward superficial velocity of liquids; C = gas anchor
constant (usually 0.2 based on laboratory data)
described by Clegg1 showed that the performance of any given size and type of gas
separator is largely dependent on the intake pressure at the anchor and the downward
superficial velocity of the fluids in the anchor. An examination on the formula done by
the author reveled that at zero pressure and zero velocity the anchor/gas separator
efficiency is 100% and that at high velocities (greater than 0.5 ft/sec) inside the gas
separator the separation efficiency is poor. Pressures above 400psig also resulted in low
efficiencies. The author however cautioned that actual experiences indicate that
separation may be significantly greater than what the formula predicts. The uncertainty in
the equation emerged from the use of the constant C which represented other
important variables such as viscosity, gas bubble size and dispersion. Laboratory results
that were not published indicated a constant of 0.2. The author warned that the
-
5
determination of accurate values of C is difficult for actual field conditions. Clegg2
strongly encouraged using a Natural gas anchor (installing the pump below the lowest
perforation) whenever it is feasible as is gives the greatest down-pass area for the liquid
thereby reducing the downward liquid velocity.
The work by Campbell and Brimhall4 largely focused on developing an industry
standard for determining the down-hole gas separator area; the dip tube area and the dip
tube length to be used for different liquid and gas flow rates. The objective of their
computer program was to aid in the design of a gas separator system and to evaluate the
pressure drops within the system and thus the system efficiency. The major parameters
which they noted were pivotal to gas separator design included the gas bubble velocity,
diameter of the mud anchor (down-hole gas separator), length of dip tube and the
pressure drops associated with the system. They agreed that the 0.5 ft/sec downward
liquid velocity inside the separator was a valid rule of thumb for low viscosity fluids.
The design procedure began with using Stokes Law (see Equation 2) to determine the
terminal rising velocity that a given gas bubble will achieve in a liquid for a given gas
bubble radius, liquid viscosity and density difference between the two phases.
2
1 22 ( )9
bg RU =
2
Where U = terminal velocity, ft/sec; g = 32.17 ft/sec2; L = liquid density; Ib/ft3 g = gas density,
Ib/ft3; = liquid viscosity; Ibm/(ft-sec); Rb = bubble radius (ft)
The second step used the calculated terminal velocity to calculate the area of the gas
separator (also called Mud Anchor or MA) using equation 3.
-
6
0.00935 LQAMAU EV
=
Where AMA = area of mud anchor, in2, QL = liquid rate,STBD
; EV = Pump efficiency
3
These calculated values are inputted into the computer program explained in
their paper to generate relationships between (1) pressure effects on gas bubble velocity
over constant viscosity and temperature (2) gas bubble velocity and diameter of the mud
anchor over different liquid flow rates (3) dip tube diameter and pressure drop in the gas
anchor over different liquid flow rates (4) pressure drop and dip tube length as a
function of liquid rate.
The results showed that gas bubbles travelled faster in smaller OD mud anchors
larger dip tube diameters yielded the smallest pressure drop and longer dip tubes had the
largest pressure drops.
Experimental results from Lisugurski5, Guzman6 and Bohorquez7 however
dispute the orders of magnitude of the results from Campbell and Brimhall4. Field
results9 based on Lisugurskis 5 thesis have shown that a 6ft long gas separator can
operate efficiently at rates which would require longer gas separator lengths if Campbell
and Brimhalls 4 results were practiced to the letter. Bohorquez7 in his work however
concluded that gas bubbles especially during the up - stroke of a sucker rod pumping
system coalesce more readily and rise faster in smaller separator annular areas compared
to larger annular areas.
Kobylinski et al 8 described the design, development and laboratory testing of a
new rotary gas separator, Figure 1-1 and Figure 1-2. The rotary gas separator is an active-
-
7
type centrifugal separator. Laboratory and field comparison were conducted between the
Centrifugal separator and the passive-type Reverse-flow separator, Figure 1-3.
Laboratory tests were done using water and air as test fluids in continuous flow
condition. The Reverse-flow separator uses the gravity separation mechanism for gas
liquid separation. The Centrifugal separator achieved separation of gas and liquid by the
use of cyclone and vortex technology. The characteristics of this method identified by
the authors were that the separated liquid is concentrated in the vicinity of the wall of the
separator while the gas phase concentrates at the center of the system. The authors
stated that dimensioning of the separator should be based on the equation of the
trajectory of the gas bubbles; they added that a general equation that would cover the
turbulence arising in the process is not available. Kobylinski et al8 believe that since both
bubble dimensions and proportionality constant between gas and liquid velocities are
unknown from Stokess law for laminar flow(1), reliance on experimental work for
design optimization remains the only alternative. A detailed discussion on bubble
dynamics is analyzed in the paper.
The results from the field tests8 complemented the results from the laboratory
and led to a 95% average improvement in fluid production when results from the active-
type centrifugal separators were compared to the passive-type reverse-flow separators in
tested wells. The dimensions of both the centrifugal and reverse-flow separators were
not given.
-
8
Figure 1-1 Centrifugal Separator Kobylinski et al
-
9
Figure 1-2 - Gas flow through centrifugal separator (Kobylinski et al)
-
10
Figure 1-3 - Reverse-flow separator (Kobylinski et al)
McCoy and Podio10 gave a detailed description of the Collar Size gas separator,
Figure 1-4. They emphasized a maximum pressure loss of PSI for friction loss in the
dip tube. The authors also highlighted the need to allow for sufficient space in the gas
-
11
separator annular area. According to the authors sufficient flow area should exist so that
the gas flow rate around the ports in the gas separator will allow liquid to flow or fall
into the gas separator annulus. The authors noted the necessity to balance the area
available for flow in the wellbore and that inside the gas separator. Decreasing the casing
annulus will result in increased upward gas velocity which when above 10 ft/second will
suspend some of the liquid and allow mist flow to occur. Another consequence of casing
annulus reduction and increase of gas velocity will be the prevention of liquid from
flowing into the gas separator annulus. The authors stressed the need for the use of large
ports. Large ports allow liquid from the casing to fall by gravity force into the gas
separator because the pressures inside and outside the large ports are the same.
Kobylinski et al8 in their paper also recommended that for a gas separator to operate
efficiently, it must ingest the two phase mixture with minimal pressure drop. This is
necessary to prevent additional gas breakout inside the separator. The Collar Size
separator10 had a total port area which was approximately four times the area inside the
gas separator. The gas separator length received special treatment by McCoy and Podio10
they suggested that the dip tube length extend at least 18 inches below the gas separator
inlet perforations (separator ports). They based their calculation on a gas rise velocity of
6in/sec (0.5ft/sec) and an average pumping speed of 10 strokes per minute which
translates to a pumping cycle time of 6 seconds. The authors also looked at eccentricity
of the separator. Earlier studies noted by the authors showed that liquid concentrates
where tubing is placed against the casing wall and thus advised that gas separators outer
diameter should contact the casing wall, see Figure 1-4.
In wells with some deviation McCoy and Podio10 advised that the separator
should be allowed to rest on the low side of the casing since gas tends to flow up on the
-
12
high side of the casing annulus by installing any tubing anchors at a distance of 60 to 90
feet shallower than the pump intake.
Figure 1-4 Collar-Size down hole gas separator (McCoy and Podio10)
Patterson and Leonard11 ran some field tests in coal-bed methane wells in
Wyoming with some changes in the down hole pump setting depth interval and for an
increase in gas separator OD. The authors noted that while the modifications were not
fully understood or tested with significant number of installations the improvements
observed warranted some discussion. The tests were conducted in two wells and are fully
described in the paper.
Patterson and Leonard11designed different gas separators used in the field tests in
a bid to achieve greater pump efficiency. The gas separators used in the tests had smaller
slot width and included vent holes and a baffle to facilitate the evolution of gas - Figure
-
13
1-5 . The concept according to the authors assumes that a smaller slot width will reduce
the amount of gas entering the gas separator and the vent holes will allow the gas that
enters to vent back to the casing. The slot sizes ranged from 0.3 wide by 6 long for the
3.5 OD gas separator (2 in number) to a 3/16 wide by 10 long for the 5.5 OD gas
separator (8 in number). The 5.5 OD gas separators also had three diameter holes
in the swedge (see Figure 1.1-5). Both separator designs had the same dip tube OD but
different dip tube lengths 2 inches difference. The 3.5 OD gas separator was 24 feet
long whereas the 5 OD gas separator was 26 feet long.
The test well , 43-26, had a 3.5 OD 8 long gas separator installed with a
Progressive Cavity Pump (PCP) at 1446 ft after a bucket test had been conducted.
After some months a 5.5OD gas separator was attached to the PCP in test well 43-26.
Although the well contained coal particles which got into the gas separator and starved
the pump intake some useful evaluations on the effect of increase in gas separator cross
sectional area were made from test well 43-26.
Due to gas separator design changes the inlet area of the 5.5 OD gas separator
design increased four times compared to the 3.5 OD gas separator design. The 5.5
OD gas separator annular area (gas separator annular area = gas separator ID dip tube
OD) increased by approximately 3 times over the 3.5 OD gas separator.
The field results11 showed that no gas was produced through the tubing when the
5.5 OD separator was run with the PCP in test well 43-26. Patterson and Leonard11
infer that the differences in inlet area and cross sectional area available for flow could
have had an impact on gas separation and would appear that some combination of these
differences has a grater influence on gas separation than only increasing the cross
sectional area. In another well test where a 4 OD gas separator with some modifications
to the entry slot area and separator length was compared to a 3.5 OD gas separator
-
14
efficiency in the same well. The authors observed that whereas the 3.5 OD gas
separator produced gas through the tubing the 4 OD gas separator did not. The authors
observed that the increase in annular area must have contributed to pump efficiency
improvement. They however speculated that the increase in length of the 4 OD
separator or the baffle design of the gas separator might also have aided to the
improvement. The authors suggested that more field tests be done and visual modeling
experiments be evaluated with different geometries and configurations to better
understand the reason(s) behind the improvements. Patterson and Leonard11 made other
related conclusions in the paper which dealt with; downward liquid velocity, essence of
vent holes, position of the inlet of the gas separator relative to the perforations and the
age old theory that placing the intake of the pump below the perforated interval creates
an effective natural gas anchor (gas separator).
Figure 1-5- Down-hole gas separator (Patterson and Leonard11)
-
15
Guzman6 experimentally determined that placing the gas separator inlet at about
3feet below the lowest perforation results in natural separation that yields total gas
liquid separation. A gas separator is not needed in such cases as long as the annular liquid
downward velocity is less than 6 inches per second.
Guzman6 also suggested that the ports area should be equal the gas separator
annular area so that the superficial liquid velocity does not control the flow regime inside
the separator. The use of vent holes in the design of Patterson and Leonard11 in the
experiments conducted by in continuous flow Guzman6 showed that the vent holes do
not improve gas separation. The author suggested the use of single row slots instead of
multiple rows. He however noted that for the decentralized wells the results might be
difficult to predict due to well eccentricity10.
Several centrifugal gas separators have been patented over the years. Most of the
patented arts require the invention have moving parts whereas some do not. The next
sections will initially describe the parts and mode of operation of patented static
centrifugal separators and finally do same for active patented centrifugal separators
1.2.1 PATENTED STATIC CENTRIFUGAL DOWN HOLE GAS
SEPARATORS
1.2.1.1 GAS ANCHOR - PATENT No 3128719
The invention (Figure 1-6) by Jongbloed et al12 in 1964 relates to a gas anchor
consisting of a cylindrical housing sealed at the bottom, at least one sheet metal helix
accommodated in the housing, and a tube (14), one side of which communicates with
the space underneath the sheet metal helix. According to the invention, a discharge
-
16
conduit is centrally positioned in the housing, the conduit is provided with openings,
preferably near the side of the sheet metal helix facing the bottom of the housing (19),
the gas discharge conduit (17) and the sheet, communicates with the outside of the
housing through the opening (21) that is above the supply openings (20).
In a reported experimental arrangement in which the outer diameter of the
helical channels was 7.5 cm (gas anchor ID = 3 inches), mixtures of varying gas/oil
ratios were supplied to a gas anchor according to the invention. The quantity of oil
passing the separator was from 1 1.5 cu. meters per hour (151 BPD 226 BPD).
When fluid mixtures (dispersions) having gas oil ratios of between 5 and 20
were supplied, the gas/oil ratio of the mixture flowing through conduit (14) was less
than 0.01.
This invention has no moving parts.
-
17
Figure 1-6 - Jongbloed et al12
1.2.1.2 Continuous Flow Down hole gas separator for Progressive Cavity Pumps - Patent No 5902378
This apparatus invented by Obrejanu Marcel13 in 1999 is a gas separator which
can be attached to the suction of a down hole pump to remove gas from the liquid
being pumped prior to the liquid entering the pump inlet. The separator has an elongate
-
18
housing having an annular chamber with guides which direct the liquid gas mixture to
flow in an annular path from the inlet to the outlet end. During this flow centrifugal
forces act to displace the gas content to the central region from which it is removed via a
separate central gas outlet so that liquid delivered to the pump inlet is greatly reduced in
its gas content.
In operation, the separator is attached in a coaxial fashion via sub (14) to the
lower end of a progressive cavity pump. In a gaseous environment the liquid will contain
dissolved gases and will enter the chamber (15) under formation pressure through the
inlet ports (16). When the pump is operated the reduction in pressure as a result of the
pump suction will cause some of the dissolved gas to come out of solution. The gas
liquid mixture is drawn upwardly within the tubular housing (12) and upon encountering
the helical flights (20) is guided thereby to move in a helical path. The centrifugal forces
created in the liquid as a result of the helical flow act to reduce the gas content of the
peripherally outer region of the flow and increase the gas content of the central region of
the flow. The angular momentum created in the liquid flow by the flights (20) is
maintained as the liquid moves upwardly into the expansion chamber (23). In this
chamber the cross sectional area of the flow passage is expanded as a result of the
termination of the flights (20), the tapering and termination of the spindle (17), and the
outwards flare of the inner wall of the tubular housing (12), the combined effects of
these resulting in a marked reduction in pressure of the liquid flow thus enhancing the
gas separation effect. The centrifugal force in the rotating liquid is effective to confine
the separated gas to the axial region of the chamber which rises above the rounded top
end (22) of the spindle. The separated gas flow through the axial exit passage (26) to the
exterior of the sub (14) where they can be released into the well bore, or if so desired
delivered to the surface through a separate conduit.
-
19
This separator has no moving parts within the separating chamber. To force the
liquid into the chamber the separator depends on both hydrostatic head and the pressure
drawdown created by the action of the PCP mounted above. Another interesting feature
about the invention is that multiple separation chambers could be attached just below
(18) for a two stage separation process before the liquid enters into the pump.
This separator design is currently been manufactured in commercial quantity in
Canada.
Figure 1-7 Static Centrifugal Separator by Obrejanu Marcel13
-
20
1.2.2 ACTIVE TYPE CENTRIFUGAL DOWN HOLE GAS SEPARATORS
1.2.2.1 Liquid Gas Separator Unit - Patent No 3887342
The unit was invented by Bunnelle P14 in 1975. The inventor claims that the unit
when tested in the laboratory could handle high liquid flow capacity of about 82 gallons
per minute (2730 BPD) at zero discharge pressure (pressure head generated by the unit)
and that this rate is slightly reduced to 70 GPM when a 26 ft3/min (37440 CFD) gas is
introduced into the unit. The test fluids where air and water.
The separator unit operates as follows. As motor shaft (58) revolves at a constant
rate impeller shaft (26) and impeller (16) likewise revolve. The impeller draws a liquid
gas mixture through intake openings (32a), into the chamber (12a). As this liquid gas
mixture moves upwardly within chamber 12a, the revolving impeller vanes (20) impart a
compound motion to it. Impeller vane segments (20b) impel the mixture primarily
upwardly through chamber (12a), while vane segments (20a) primarily impart circular
motion to the upwardly moving mixture, thereby centrifuging the liquid component of
the mixture of the mixture outwardly away from the impeller hub (18) and causing
undissolved gas present in the liquid to move inwardly toward the hub (18). The
separated liquid flows up through discharge channels (100) into discharge element
chamber (72a). The separated gas forms a liquid free gas column around hub, the
column of gas moves upwardly into discharge element chamber 86a from where the gas
flows into inlets (96b) and through gas conducting channels (96) to discharge outlets
(96a) in nearly vertical, upward directions. The channel outlets discharge discrete high
velocity gas streams of separated gas that are substantially upwardly directed to promote
-
21
upward movement of the discharged gas within a wellbore where the separated unit is
situated.
Figure 1-8 Invention by Bunnelle P14
1.2.2.2 Liquid Gas Separator Apparatus - Patent No 4481020
This centrifugal liquid-gas separator is same as described in earlier section (see
Figure 1-1). Here the mode of operation is briefly summarized with an explanatory
pictorial shown in Figure 1-9.
In operation the pump, separator apparatus (Figure 1-9) and motor are
submerged down hole within a liquid gas well fluid mixture. The liquid - gas enters
the intake ports (54) of the intake head (18) through a perforated or slotted member
-
22
(100) which assists in filtering debris from the fluid mixture. From the intake ports, the
fluid mixture enters the inducer (48) which pressurizes the fluid mixture and supplies it
to the centrifugal separator (50) via transition region (52). The transition region, which is
designed to provide a uniform rate of change through in flow direction and velocity to
the fluid mixture, conveys the fluid mixture smoothly to the centrifugal separator while
minimizing pressure loss. At the outlet end of the transition region, the tangential
velocity of the fluid approaches angular velocity of the centrifugal separator vanes and
the axial velocity of the fluid approaches the flow through velocity of the apparatus.
Liquid gas separation occurs at the inlet of the centrifugal separator region and
continues throughout its length. The liquid section is supplied to the pump through (86),
while the separated gas is vented via gas vents (90) into the space between the well casing
and the separator.
The rotary motion to the inducer and extending vanes are supplied by an
attached motor (20)
-
23
Figure 1-9 - Centrifugal Separator by Kobylnski et al
1.2.2.3 Recirculating Gas Separator for Electrical Submersible Pumps - Patent
No 4981175
This invention by Powers Maston15 in 1991(Figure 1-10) is a modification of
Lee et al (Figure 1-9). The inventor claims that by including a recirculating means (56)
for recirculating a portion of the discharged liquid from the discharge outlet (50) back to
the separator chamber (46) the gas oil ratio in the separator becomes substantially
lower than a gas to liquid ratio of well fluid entering the well fluid intakes (48). The
recirculating means includes all of the following:
1. Extraction chamber (60)
-
24
2. Liquid injection chamber (62)
3. Conduit (64)
A drive motor will be needed to extend an upward motion to drive all the
separator mechanisms.
Figure 1-10 Invention by Powers Maston15
1.2.2.4 Apparatus for separating gas and solids from well fluids - Patent No
6382317 B1
The apparatus invented by Delwin E. Cobb16 Figure 1-11, is designed to separate
gas and solids from well fluids in a wellbore.
-
25
The gas and solids are removed from the well fluids in two separate steps by two
separate spirals, one spiral for the gas (66) and a separate spiral for the solids (70). An
upper gas spiral is positioned below the openings (60) in the outer tubular housing (44)
and a separate lower spiral spaced axially from the upper gas spiral is provided for the
solids. The spirals are positioned in the annulus between the outer tubular housing and
the inner flow tube (46). The spirals provide a helical flow and are spaced axially from
each other at a distance. The gas accumulates in the swirl chamber (80) between the
spirals and is librated from the liquid. The gas normally exists as large bubbles through
an inner gas annulus (72). The liquid flows downwardly in a helical path to the solids
spiral.
The solids, such as sand are separated from the well fluid by the solids spiral and
fall by gravity into the mud anchor or other suitable collection area. The liquid then
flows upwardly in the flow tube (46) to be pumped for flow to a surface location.
This invention makes use of induced centrifugal motion and gravity to separate
gas and solids from wellbore fluids.
The invention has no moving parts.
-
26
Figure 1-11 Invention by Delwin Cobb16
Figure 1-12 Cross section (3) in Figure 1-11
-
27
The research reported in this thesis extended the experiments of Kobylinski et al8
and the theory behind the inventions of Jongbloed et al12 and Obrejanu13 in the sense of
using gravity, agitation and centrifugal forces as physical mechanisms to obtain improved
gas liquid separation. The difference between this research and Kobylinski et al8 is in
the use of different experimental procedure, experimental facilities and most importantly
that the centrifugal down hole gas separator must have no moving parts; it must be
static similar to the inventions of Jongbloed et al12 and Obrejanu13.
This research also investigated experimentally the points raised by Patterson and
Leonard11 in terms of the effect of the increase in the gas separator annular area and
improvement in pump efficiency. Visual observation as Patterson and Leonard11
suggested was used to capture the separation mechanism(s) in the production
engineering laboratory at University of Texas at Austin as described in the next chapter.
-
28
Chapter 2
Experimental Facility and Procedure
This chapter fully describes the facilities, equipment and procedure used in
acquiring laboratory data used throughout this research. The down hole gas separators
used for the purposes of this experimental study are described in detail.
2.1 EXPERIMENTAL FACILITIES
The separator designs were installed in a laboratory well model and tested over a
range of 120 900 BPD of water and air rates between 13 115 MSCFD. The input
into the experimental test system was water and air at pre - determined rates Qg and Qw;
the output from the system included the pressures at the entry ports, tubing pressure and
the gas flow-rate through the dip tube of the separator. The inputs and outputs are
combined in a mathematical model to calculate the pump liquid fraction (pump
efficiency) of the separator relative to particular input values.
This chapter describes the facilities at The University of Texas Production
Laboratory and the procedure used to input and acquire data.
2.2 DESCRIPTION OF EXPERIMENTAL FACILITIES
Figure 2-1 and Figure 2-2 show schematic and overview pictures of the
production laboratory facility used for testing down-hole gas separator designs. The test
facility is a closed loop system with manually controlled valves for fluid flow control.
Water was pumped in a loop into and out of a 3 - phase separator into the well (Figure
-
29
2-3) Air was supplied to the system by a compressed air line. Water and air meet at the
mixer before entering into the well. The hoses lead the mixture from the manifold
through the casing perforations into the well. Water is returned to the 3 phase
separator through a return a line. Air that passes through the dip tube is carried with the
water into the 3 phase separator and the rest rises up the casing.
-
30
Figure 2-1 Schematic of experimental test facility
-
31
Figure 2-2 Laboratory facility
Figure 2-3 Laboratory test well
-
32
2.3 LABORATORY TEST WELL
The bottom parts of the well are made of clear acrylic pipe to allow observation
of the gas and liquid phases inside the separator. Figure 2-3 shows close up pictures of
the laboratory well. Figure 2-4 shows the full laboratory well picture, notice that the
down hole gas separator is placed below the down hole pump. All the laboratory
tests were conducted with the gas separator situated in such position. The down-hole gas
separator components are positioned in the laboratory well as they would in a real well.
The mud anchor is the outer barrel of the separator. The mud anchor entry ports or
inlets allow water and some of the air to flow into the separator. The dip tube is the
small diameter tube inside the separator. The water flows down in the separator annular
area to the dip tube suction. Then the water flows up through the dip tube to the tubing
intake shown in Figure 2-4.
The bottom part of the casing has an ID of 6 inches. The upper part is PVC pipe
that extends to the rooftop of the Petroleum Engineering building at the University of
Texas, approximately 80ft. as seen in Figure 2-4. The bottom section of the casing has
several perforations, 31/64 inch in diameter, distributed at different positions. This way
it is possible to vary the relative location of the down-hole separator entry ports with
respect to the perforations.
-
33
Figure 2-4 Laboratory Well
Ports Pressure gauge (P2)
Casing Pressure gauge (P1)
Tubing Pressure gauge (P3)
Location of the separator
-
34
2.3.1 LABORATORY INSTRUMENTS
The instruments used in the conducting all the tests used for this research are
shown below. The functions that they performed are also explained.
2.3.1.1 LIQUID FLOW MEASUREMENTS
Figure 2-5 is a photo of the Daniel MRT97 turbine flow meter, used to measure
the water flow rate, installed in the liquid loop before the mixer. The water flow was
controlled by the valve in the same picture.
Figure 2-5 Turbine flow meter and valve between pump and mixer
The ITT Barton Floco positive displacement meter (ITT Barton, model 308K)
was used only for reference. It is installed between the turbine flow meter and the mixer.
-
35
Figure 2-6 - - ITT Barton floco positive displacement meter
2.3.1.2 GAS FLOW MEASUREMENT
The air flow into the mixer was controlled with the Fisher Porter flowrator tube
and the valve shown in Figure 2-7. The flowrator tube displays the airflow as a
percentage of the maximum flow rate, 16416 CFD. The percentages used in the tests
were 10, 20, 30, 60 and 90. The pressure in the compressed air line was measured by a
pressure transducer to convert the actual air flow rate to standard conditions using the
ideal gas law since working pressure of less than 100psi and laboratory temperature,
allowed assuming a Z factor in the vicinity of 1.0.
-
36
Figure 2-7 - Fisher Porter Flow Rator tube
Figure 2-8 shows the Omega FMA-A2313 thermodynamic mass flow meter
installed at the top outlet of the three - phase separator. This instrument gave the most
important reading in the tests, the amount of air that enters the pump. The units on the
display are in standard liters per minute with accuracy of 1%.
-
37
Figure 2-8 - Thermodynamic Omega Air Flow Meter
2.3.2.2 PRESSURE MEASUREMENT
The casing pressure (see Figure 2-4) was used as a control variable for the entire
system. This pressure was set between 10 psig 13 psig for all experiments. These
pressure values correspond to the maximum liquid volume in the casing that can be
managed at the highest gas flow rates without overflowing at the top of the well model.
This value was measured using an analog pressure gauge (Ashcroft, model Q-9047).
An analog pressure gauge (Ashcroft, model Q-9047) determined the annular
casing pressure at the entry of the top ports of the down-hole gas separator Figure 2-4,
P2. This pressure is measured within a foot from the ports and this value is used as a
reference value to determine the pressure drop inside the down-hole gas separator.
The discharge pressure of the separator is considered to be equivalent to the
pump intake pressure see Figure 2-4, P3. This pressure is equivalent to the pump
intake pressure. This pressure was measured using a pressure/ vacuum gauge, calibrated
-
38
in psig for positive values of pressure and in inches of mercury for vacuum. One of the
applications this pressure is to determine the pressure drop that occurs between the
separator in-take (P2) and the tubing pressure/discharge pressure (P3).
2.4 EXPERIMENTAL PROCEDURE
Use Figure 2-1 to follow the step - by - step procedure shown next. Before beginning
1. Make sure that there is sufficient water in the separator using the level
control. Add water if necessary
2. Make sure that the desired ports in the manifold are open to inject flow from
the desired position relative to the down-hole gas separator entry ports
Starting the flow of fluids in the loop and setting the system in steady state
3. Turn on the pump
4. Use valve G to regulate the water flow rate. The gallons per minute read
by the turbine flow meter should approximately result in the desired BPD.
Valve G and the turbine flow meter are shown in Figure 2-5.
5. Gradually open the air flow to the desired percentage. It is usually set at
0% for the first experiment. There are three valves involved in the airflow.
First open valve D to let air in from the compressed air line. Then set the
desired percentage with valve E (seen in Figure 2-7).
-
39
6. Finally open valve F to let air mix with the water. Valve F should be
opened carefully. Otherwise the sudden injection of air can cause the
water to come out the top of the well.
7. By closing valve A, let water accumulate in the well until a desired bottom
hole pressure is obtained. The pressure gauge labeled BHP in Figure 2-1
indicates the bottom hole pressure. All the continuous flow tests were
run between 10 13 psi. Once the desired hydrostatic head is obtained,
regulate the flow out of the well to match the flow entering the well using
valve A. This way, the BHP and liquid level inside the three phase
separator are kept constant. This control is done throughout the test.
2.5 SEPARATOR PERFORMANCE DISPLAY
The performance plots are displayed as three Dimensional graphs, Figure 2-9.
The plots are presented both in terms of oil field units and in terms of superficial
velocities.
In terms of oil filed units the x axis represents the input liquid flow rate in
BPD entering into the well through the perforations; the y axis is the gas flow rate in
MSCFD entering the laboratory well; the z axis is the gas rate through the separator in
MSCFD. This represents the gas that would enter the pump in a real well having the
down hole gas separator installed immediately below the pump intake.
In terms of superficial velocity the x axis is labeled the superficial liquid
velocity inside the separator in inch/second. The y axis represents the superficial gas
-
40
velocity inside the casing annulus in inch/second and the z axis is the gas rate through
the separator in MSCFD.
The height of each dot (and/or the vertical bar) on the 3 D performance plot
corresponds to the gas rate through the separator for a given liquid and gas rate either in
terms of oil filed units or in terms of superficial velocity.
The data used in plotting the performance plots are managed with an Excel
spreadsheet, see a sample data set in Table 2-1.
The inputs for the spreadsheet include the following:
1. The actual start and end time for each conducted test
2. The casing, ports and tubing pressures (P1, P2 and P3) psi
3. The Floco meter reading (sec/0.1 bbl)
4. The input gas meter pressure (psi)
5. The measured gas rate through the separator (SLM).
The spreadsheet calculates the following;
1. The liquid input rate (BPD)
2. The gas rate (MSCFD)
3. The superficial velocities for both liquid and gas (inch/second) inside the
casing and inside the separator.
4. Gas rate through the separator (MSCFD)
-
41
5. The pump liquid fraction
The spreadsheet provides all the information needed to accurately study the
performance of each separator design.
All the laboratory tests conducted were run under continuous flow condition. In
this type of test the valve H is completely open so that there is constant liquid and gas
rate throughout the system.
-
42
Table 2-1 - Sample Excel Spreadsheet for continuous flow test
-
43
Figure 2-9 - Sample Performance plot for Patterson (3X1) in continuous flow
-
44
2.6 DOWN HOLE GAS SEPARATOR DESIGNS
Seven down hole gas separator designs were tested. Two of the four gravity driven
separators were originally constructed in 2004 and 2005 and were used with minor
modifications. The other two were constructed in 2007. The three static centrifugal
separators were constructed between summer 2006 and summer 2007.
2.6.1 ECHOMETER (3X1), ECHOMETER (3X1.5), ECHOMETER (4x1),
ECHOMETER (4X1.5), ECHOMETER (4X1.75)
The naming procedure is given as: (separator name) (separator OD x dip tube OD).
Continuous flow tests2 were run on these separators between spring 2006 and
summer 2007 for the purposes of:
a. Comparing the performance of a gravity driven separator to that of a centrifugal
separator
b. Studying the effect of increasing the separator annular area
c. Studying the pressure drop inside the separator
d. Verifying the effect of port geometry
Figure 2-10 and Figure 2-12 are pictures of the Echometer (3X1) and Echometer
(4X1) design respectively. There are two sets of four slots. Each slot is 4 inches long and 2
inches wide. The first set is located 11 inches below the separator thread and the second set
2All the continuous flow tests were conducted with fluid entering from below the separator through the bottom four perforations located adjacent the separator see Figure 2-4
-
45
is 16 inches below the thread. There is a distance of 24 inches between the lower slots and
the dip tube suction and 44 inches between the upper slots and the dip tube suction.
Both the 3inch and 4inch OD Echometer separators have a wall thickness of 0.125
inch so that the IDs are 2.75 inch and 3.75 inch respectively. The dip tube wall thickness is
also 0.125 inch, making the ID of the dip tube a quarter of an inch less than the dip tube
OD.
The 4 inch OD Echometer separators have the same design configurations as the 3
inch OD Echometer separators, except for larger diameter.
A summary of the Echometer separator design configurations is shown in Table 2-2
below.
Table 2-2 Echometer gas separators configuration
Separator type
Number of slots
Size of slots (WXL) (inch)
Total area of slots (in2)
Area of separator dip tube
annulus (in2)
Area of casing separator
annulus (in2)Echometer (3X1) 4 2X4 32 5.15 21.20 Echometer (3X1.5) 4 2X4 32 4.17 21.20 Echometer (4X1) 4 2X4 32 10.26 15.70 Echometer (4X1.5) 4 2X4 32 9.28 15.70 Echometer (4X1.75) 4 2X4 32 8.64 15.70
-
46
Figure 2-10 Echometer (3 X1.5) gas separator design
Figure 2-11- Echometer entry port geometry
Figure 2-12 Echometer (4X1.75) gas separator design
-
47
2.6.2 PATTERSON (3X1), PATTERSON (3X1.5), PATTERSON (4x1),
PATTERSON (4X1.5), PATTERSON (4X2)
The naming principle is same as the Echometer designs. Continuous flow tests were
run concurrently for both designs between spring 2006 and fall 2007. The purpose of the
tests is same as listed for Echometer design.
The Patterson design has 16 thin and long entry slots. The slots are 1/8 inch wide
and 8 inch long. There are 0.5 in diameter vent holes. Table 2-3 is a summary of the
Patterson separator configuration.
Table 2-3 Patterson Separator Configuration
Separator type
Number of slots
Number of inch
holes
Size of slots
(WXL) (inch)
Total area of slots
(in2)
Area of separator dip tube annulus
(in2)
Area of casing separator annulus
(in2) Patterson
(3X1) 16 4 1/8 X 8 16 5.15 21.20
Patterson (3X1.5) 16 4 1/8 X 8 16 4.17 21.20
Patterson (4X1) 16 4 1/8 X 8 16 10.26 15.70
Patterson (4X1.5) 16 4 1/8 X 8 16 9.28 15.70
Patterson (4X1.75) 16 4 1/8 X 8 16 8.64 15.70
Patterson (4X2) 16 4 1/8 X 8 16 7.90 15.70
-
48
Figure 2-13 4 inch OD Patterson Separator Design
Figure 2-14 3 inch OD Patterson Separator Design
2.6.3 TWISTER
The separator named The Twister is the first in the series of static centrifugal
separators constructed since summer 2006. The initial results of the performance of the
Twister as reported by Bohorquez7 pointed to the need for more inquests into the
-
49
performance of static centrifugal separators based on the Echometer and Patterson separator
entry port designs.
The twister design uses a wire reinforced PVC hose used as a dip tube. The hose has
a 1.028 in OD and a 0.75 in. ID. The reinforced PVC is spiraled four full turns inside the
gas separator, Figure 2-15. The hose is twirled inside the gas separator and a plate is used to
secure the hose in place.
The straight dip tubes (for example, Echometer (3X1)) used for gravity separator
designs are directly connected to the wells tubing. But for the centrifugal design the
connection to the tubing is different. Figure 2-15 is a picture of the twister connection. The
arrows show the flow path for the gas through the gas vents and the liquid through the spiral
tube connection.
In operation the gas liquid mixture enters through the three circular entry ports of
the Twister separator. The helical dip tube induces a centrifugal motion on the mixture
entering through the ports. Gas is evolved and a coalescing zone is formed. The length of
the coalescing zone depends on the gas and liquid flow rates. The liquid mass is forced to
the inner walls of the separator by centrifugal forces and the gas mass accumulates at the
center (coalescing zone). While the gas rises to the gas vents at the separator connection to
escape into the casing annulus the liquid flows down towards the dip tube suction and
thereafter into the pump by gravity forces. Figure 2-17 shows a diagrammatic of the forces
acting on the mixture as soon as it enters into the separator annulus.
Laboratory observations show that the helical dip tube induces the centrifugal
motion by virtue of its design; a bubble coalescing zone is formed in the center of the
separator; the bubbles coalesce and become bigger bubbles in the coalescing zone and thus
rise faster; the liquid momentum is reduced by the helical nature of the dip tube. This greatly
The full construction detail for the Twister is covered in the thesis report by Bohorquez, 2006.
-
50
improved the gas pathway through the core of the separator eliminating the need for a gas
venting tube.
The operation of the twister is similar to the invention by Jongbloed et al12 since
both are static type separators. The basic difference between the two is that the twister does
not have a gas discharge conduit instead it has inclined gas vent holes at the connection head
(Figure 2-16). The Twister design also has similarity with the invention by Obrejanu13. Apart
from both separator designs been static by construction both separator designs depend on
the helical nature of the separator internal design to induce centrifugal motion and thus
centrifugal forces on the fluid flow inside the separator. The centrifugal forces induced
become the driving mechanism for gas liquid separation. The main differences between
the two are the entry port placement and gravity effects. The Twister has three entry port
circles at the top of the separator; the separator design by Obrejanu13 has the entry port at
the bottom part of the separator. The Twister depends to a significant extent on gravity for
gas liquid separation as well as on hydrostatic head to flow the mixture through the
separator. The gas separator by Obrejanu13 depends on both hydrostatic head and pressure
drawdown created by the action of the PCP to operate efficiently. Whilst the advantages of
having the entry ports at the bottom part of the gas separator is founded by density
difference; in the case of fines production the PCP rotor will erode at a faster pace causing
pre mature pump damage.
-
51
Figure 2-15 Twister Separator (Bohorquez)
Figure 2-16 Twister Connection
Gas Vent holes
Spiral Tube Connection
-
52
coalescing zone
Improved gas path way
Induced centrifugal motion
Dip tube acts as baffles which reduce liquid momentum
Figure 2-17 Diagrammatic of the forces acting in a static centrifugal separator
2.6.3.1 ECHOMETER TWISTER
The Echometer Twister is a static centrifugal separator. The design is very similar
to the Twister as per the dip tube design which is helical. The major difference between the
two separator designs is the entry port geometry. While the Echometer design has four 4X2
slots the Twister has 3 circular entry ports and 4 half inch vent holes.
The main objective of constructing the Echometer Twister is to study the effect of
centrifugal forces on separation performance. A head to head comparison is made
between Echometer (3X1) and Echometer Twister to understand the controlling
mechanisms.
-
53
Figure 2-18 is the picture of the laboratory constructed Echometer Twister
separator.
Figure 2-18 Echometer - Twister
2.6.3.2 PATTERSON TWISTER
The Patterson Twister is the third in the series of static centrifugal separators
constructed. This separator design (Figure 2-19) has the same entry port geometry has the
Patterson (3X1). Like the Echometer Twister it was constructed to comparatively study
the effect of centrifugal forces on the previously constructed Patterson (3X1) separator
design. The Patterson Twister also has a dip tube with four full turns/twists with pitch
length of 12 14 inches lying at an angle of 45o on the inner walls of the separator.
-
54
Figure 2-19 Patterson - Twister
-
55
Chapter 3
Analysis Of Experimental Results
3.1 EFFECT OF HELICAL DIP TUBE DESIGN
These experiments studied the effect of changing the dip tube design from the
conventional straight shape to a helical form.
The designs experimentally tested include the following; The Echometer-Twister,
Patterson-Twister (2 twists and 4 twists) and the Twister, which was previously tested by
Bohorquez7.
The following parameters were examined during the experimental tests of the
separators:
Liquid input rate: up to 600 BPD
Gas flow rate: 0 MSCFD to 115 MSCFD
Superficial liquid velocity in the separator: up to 14 in/sec
Superficial gas velocity in the casing: up to 70 in/sec
Casing pressure: between 10 and 13 psi
-
56
The performance plots for each of the static centrifugal separators are presented in
the following sections and a comparative analysis is presented thereafter so that the effects
of the change in dip tube design are effectively captured.
3.1.1 PERFORMANCE RESULTS FOR THE TWISTER SEPARATOR
Figure 3-1 and Figure 3-2 show the performance plots for the Twister separator in
continuous flow in both field units and in terms of superficial velocity. Notice that the
Twister achieved a zero gas flow rate through the separator up to a downward superficial
liquid velocity (Vsl) of 10 in/sec for all gas rates tested. This liquid rate is equivalent to 430
BPD. The area highlighted in red represents the optimum performance for the Twister
separator. Approximately no gas entered into the dip tube suction in this area for these
conditions of liquid and gas flow.
-
57
Figure 3-1- Twister results in field units
Separator Type: TwisterOD Dip Tube = 1; Number of Slots = 3; Number of Twists = 4; Casing Pressure = 10 13 psi
Dimension of Slots =2 1 holes & 1 1.5 hole; Position of the Separator = Above the Perforations
-
58
Figure 3-2 - Twister result in terms of superficial velocities
3.1.2 PERFORMANCE RESULTS FOR ECHOMETER TWISTER
SEPARATOR
In Figure 3-3 and Figure 3-4 the performance results for EchometerTwister
separator are shown.
Separator Type: TwisterOD Dip Tube = 1; Number of Slots = 3; Number of Twists = 4; Casing Pressure = 10 13 psi
Dimension of Slots =2 1 holes & 1 1.5 hole; Position of the Separator = Above the Perforations
-
59
Figure 3-3 Echometer - Twister result in terms of superficial velocities
Separator Type: Echometer - TwisterOD Dip Tube = 1; Number of Slots = 4; Number of Twists = 4; Casing Pressure = 10 13 psi
Dimension of Slots =2 X 4; Position of the Separator = Above the Perforations
-
60
Figure 3-4 Echometer - Twister results in field units
The region highlighted in red in both plots depicts areas where it was observed that
no gas entered into the dip tube suction of the EchometerTwister separator. Notice that in
Figure 3-3 the no gas zone was established at a downward Vsl 10 inch/sec.
Separator Type: Echometer - TwisterOD Dip Tube = 1; Number of Slots = 4; Number of Twists = 4; Casing Pressure = 10 13 psi
Dimension of Slots =2 X 4; Position of the Separator = Above the Perforations
-
61
3.1.3 PERFORMANCE RESULTS FOR PATTERSON TWISTER
SEPARATOR
Both Figure 3-5 and Figure 3-6 show the results for the PattersonTwister Separator
in continuous flow in terms of superficial velocities and in field units.
Figure 3-5 - Patterson - Twister result in terms of superficial velocities
Separator Type: Patterson - TwisterOD Dip Tube = 1; Number of Slots = 16; Number of Twists = 4; Casing Pressure = 10 13 psi
Dimension of Slots =1/8 X 8; Position of the Separator = Above the Perforations
-
62
Figure 3-6 - Patterson - Twister results in field units
In the following sections a comparison is made between the separation performances
of EchometerTwister and Echometer (3X1) and then Patterson Twister and Patterson
(3X1) in terms of both superficial velocity and field units.
Separator Type: Patterson - TwisterOD Dip Tube = 1; Number of Slots = 16; N