AN22 Pre-weighted tube - Andersen Products · Balloon type Adult Radiopaque Sterile 8ft / 2.44m 16...

1
Balloon type Adult Radiopaque Sterile 8ft / 2.44m 16 Fr. www.anpro.com Andersen Products, Inc. Health Science Park • 3202 Caroline Drive Haw River, NC 27258-9564 USA 800-523-1276 • fax 336-376-8153 www.andcal.com H. W. Andersen Products of California, Inc. Health Science Park • 3151 Caroline Drive Haw River, NC 27258-9789 USA 800-524-3455 • fax 336-376-3088 Distributed in Europe by: H. W. Andersen Products, Ltd. Davy Road • Clacton-on-Sea Essex CO15 4XA UK sterilization redefined For hyperactive bowel & intraoperative passage The 24 aspirating ports reduce clogging of the aspirating tube by screening out particulate matter. The externally inflatable balloon is invaginated over the weighted tip of the tube making transnasal and transpyloric passage easy. Pre-weighted (with tungsten weights encapsulated at the tip) to aid passage through the pylorus. When duodenal intubation has been confirmed, the balloon is inflated with air providing an adequate bolus for the bowel to move the tube along. Markings at 65, 75, 100, 125, 150, 175, and 200 cm from the distal tip aid in the positioning of the tube during passage. To decompress the small intestine, the AN22 should be used on straight gravity drainage or with electric aspirators intended for gastrointestinal suction. The aspirating tube requires irrigation with normal saline hourly. The Andersen ® Intestinal Tube, Miller-Abbott Type is packed 10 per box. Each tube is 8ft. / 2.44m., sterile, with detailed instructions for use. Pass the AN-22 pre-weighted long tube transnasally to the level of the stomach. The tungsten weighted tip provides the mass to easily aim the tube tip at the polyorus. Pass it through the polyrus under x-ray image intensification control. When duodenal intubation has been confirmed, the balloon is inflated with air injected down the small tube to provide a bolus to help move the tube through the intestines. The Andersen ® Intestinal Tube, Miller-Abbott Type is a bilumenal intestinal tube with an inflatable latex balloon tip designed for those situations where the aspiration of liquid and air from the gastrointestinal tract is of therapeutic importance. The AN22 can be used for the temporary management of early mechanical obstruction in the small and large intestines. This is a straight drainage tube, not a sump tube. PN628_032003 Andersen ® Intestinal Tube, Miller-Abbott Type AN22 Pre-weighted tube No mercury required Pre-Weighted Pylorus Stomach Obstruction

Transcript of AN22 Pre-weighted tube - Andersen Products · Balloon type Adult Radiopaque Sterile 8ft / 2.44m 16...

Page 1: AN22 Pre-weighted tube - Andersen Products · Balloon type Adult Radiopaque Sterile 8ft / 2.44m 16 Fr.  Andersen Products, Inc. Health Science Park • 3202 Caroline Drive

Balloon type Adult Radiopaque Sterile8ft / 2.44m 16 Fr.

www.anpro.comAndersen Products, Inc.Health Science Park • 3202 Caroline DriveHaw River, NC 27258-9564 USA800-523-1276 • fax 336-376-8153

www.andcal.comH. W. Andersen Products of California, Inc.Health Science Park • 3151 Caroline DriveHaw River, NC 27258-9789 USA800-524-3455 • fax 336-376-3088

Distributed in Europe by:H. W. Andersen Products, Ltd.Davy Road • Clacton-on-SeaEssex CO15 4XA UK

sterilization redefined

For hyperactive bowel & intraoperative passage

The 24 aspirating ports reduce clogging of the aspirating tube by screening out particulate matter.

The externally inflatable balloon is invaginated over the weighted tip of the tube making transnasal and transpyloric passage easy.

Pre-weighted (with tungsten weights encapsulated at the tip) to aid passage through the pylorus. When duodenal intubation has been confirmed, the balloon is inflated with air providing an adequate bolus for the bowel to move the tube along.

Markings at 65, 75, 100, 125, 150, 175, and 200 cm from the distal tip aid in the positioning of the tube during passage.

To decompress the small intestine, the AN22 should be used on straight gravity drainage or with electric aspirators intended for gastrointestinal suction. The aspirating tube requires irrigation with normal saline hourly.

The Andersen® Intestinal Tube,Miller-Abbott Type is packed 10 per box. Each tube is 8ft. / 2.44m., sterile, with detailed instructions for use.

Pass the AN-22 pre-weighted long tube transnasally to the level of the

stomach. The tungsten weighted tip provides the mass to easily aim the

tube tip at the polyorus. Pass it through the polyrus under x-ray

image intensification control. Whenduodenal intubation has been

confirmed, the balloon is inflatedwith air injected down the small tube

to provide a bolus to help move the tube through the intestines.

The Andersen® Intestinal Tube,Miller-Abbott Type is a bilumenalintestinal tube with an inflatable latexballoon tip designed for those situationswhere the aspiration of liquid and airfrom the gastrointestinal tract is oftherapeutic importance. The AN22 can be used for the temporary management of early mechanical obstruction in the small and large intestines. This is a straight drainage tube, not a sump tube.

PN628_032003

Andersen® Intestinal Tube,Miller-Abbott Type

AN22 Pre-weighted tube

No mercury required Pre-Weighted

Pylorus

Stomach

Obstruction