An investigation on the fresh properties of self-compacted lightweight concrete containing expanded polystyrene Rahmat Madandoust , Malek Muhammad Ranjbar, S. Yasin Mousavi Department of Civil Engineering, University of Guilan, P.O. Box 3756, Rasht, Iran article info Article history: Received 1 November 2010 Received in revised form 15 March 2011 Accepted 11 April 2011 Available online 4 May 2011 Keywords: Self-compacting lightweight concrete Expanded polystyrene aggregate Hauling time Workability Nano-SiO 2 abstract This paper presents the fresh properties of structural self-compacted lightweight concrete (SCLC) con- taining expanded polystyrene (EPS) assessed by means of slump flow, T 50 , V-funnel and L-box tests. Fif- teen mixes including different water/binder (W/B) ratios, nano-SiO 2 contents and EPS percentages (10%, 15%, 22.5% and 30% by volume) were designed. The change in slump flow by hauling time was also eval- uated and was predicted with multiple regression equations. The results indicate that mixtures with density higher than 1900 kg/m 3 (up to 22.5% EPS) generally sat- isfy the self-compactibility criteria of SCLC containing EPS. The nano-SiO 2 addition has some negative effects on the fresh self-compacted concrete (SCC), but this is to be less for EPS mixtures. While, the slump flow of SCLC containing EPS decreased up to 6% by reducing the given W/B ratio, T 50 and V-funnel times increased in the ranges of 23–29% and 18–48%, respectively. EPS inclusion in SCC shows an increase in the slump flow retention up to 17%. Additionally, by using nonlinear multiple regression, the slump flow with hauling time can be accurately predicted. Ó 2011 Elsevier Ltd. All rights reserved. 1. Introduction The traditional vibrated concrete produces differential compac- tion and hence differential durability. This aspect coupled with shortage of skilled workmen and noisy nature of vibrated concrete were the factors which forced to develop a new type of high perfor- mance concrete, namely self-compacted concrete (SCC). The main requirements of fresh SCC are filling ability, passing ability and very high segregation resistance. SCC contains powder material as constituent in addition to the traditional concrete materials. Therefore, in general, the density of SCC seems to be higher than the density of normal concrete [1,2]. Use of lightweight aggregates in the production of concrete can decrease the self-weight of structures. This can result in reduced members’ sections and, therefore, it will save on overall construc- tion costs. Lightweight aggregates are generally classified either as natural or artificial. Expanded polystyrene (EPS) beads are a type of artificial ultra-lightweight non-absorbent aggregate [3]. Polysty- rene is a thermoplastic polymeric material initially in the solid form and it can be expanded by the use of steam and expansive agents transform to EPS beads. EPS aggregates are commercially available worldwide and have a closed cell structure consisting essentially of 98% air. The main problem associated with lightweight aggregates is that these porous aggregates absorb a large quantity of the mixing water. This absorption by the aggregate will mean that additional water will be required to maintain the workability at acceptable levels. Hence, higher cement content will be necessary without any increase in strength. For this case, non-absorbent, artificial ul- tra-lightweight EPS aggregate can be suitable [4–9]. Noticeable problems associated with unsuitable vibration of lightweight concrete was reported for the inefficient distribution of lightweight aggregates, especially EPS aggregate [8,10]. This will tend to move the lightweight aggregate to the surface of concrete and forms a weak layer. To have all benefits of lightweight aggre- gate concrete, self-compacted lightweight concrete (SCLC) that does not need any vibration seems to be an efficient choice to over- come these problems [11]. Providing that SCLC is compacted under its self-weight without any compaction, it is necessary to compro- mise between self-compactibility and weight of SCLC. So, the pri- mary objective of the present study is to provide information about the balance between self-compactibility and weight of SCLC containing EPS. Earlier studies have been focused on EPS aggregate usage in or- dinary mortar or concrete for both structural and non-structural applications [4–9]. Some authors studied the behavior of EPS con- crete containing supplementary cementitious materials [4,7]. Ef- fect of EPS aggregate size on concrete strength and moisture migration characteristics has been presented by Babu et al. [5]. The durability of EPS lightweight concrete was reported by Babu 0950-0618/$ - see front matter Ó 2011 Elsevier Ltd. All rights reserved. doi:10.1016/j.conbuildmat.2011.04.018 Corresponding author. Tel.: +98 9113314970; fax: +98 1316690271. E-mail address: [email protected] (R. Madandoust). Construction and Building Materials 25 (2011) 3721–3731 Contents lists available at ScienceDirect Construction and Building Materials journal homepage: www.elsevier.com/locate/conbuildmat

description

Propiedades concreto aligerado con poliestireno expandido

Transcript of An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded...

Page 1: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

Construction and Building Materials 25 (2011) 3721–3731

Contents lists available at ScienceDirect

Construction and Building Materials

journal homepage: www.elsevier .com/locate /conbui ldmat

An investigation on the fresh properties of self-compacted lightweightconcrete containing expanded polystyrene

Rahmat Madandoust ⇑, Malek Muhammad Ranjbar, S. Yasin MousaviDepartment of Civil Engineering, University of Guilan, P.O. Box 3756, Rasht, Iran

a r t i c l e i n f o

Article history:Received 1 November 2010Received in revised form 15 March 2011Accepted 11 April 2011Available online 4 May 2011

Keywords:Self-compacting lightweight concreteExpanded polystyrene aggregateHauling timeWorkabilityNano-SiO2

0950-0618/$ - see front matter � 2011 Elsevier Ltd. Adoi:10.1016/j.conbuildmat.2011.04.018

⇑ Corresponding author. Tel.: +98 9113314970; faxE-mail address: [email protected] (R. Mad

a b s t r a c t

This paper presents the fresh properties of structural self-compacted lightweight concrete (SCLC) con-taining expanded polystyrene (EPS) assessed by means of slump flow, T50, V-funnel and L-box tests. Fif-teen mixes including different water/binder (W/B) ratios, nano-SiO2 contents and EPS percentages (10%,15%, 22.5% and 30% by volume) were designed. The change in slump flow by hauling time was also eval-uated and was predicted with multiple regression equations.

The results indicate that mixtures with density higher than 1900 kg/m3 (up to 22.5% EPS) generally sat-isfy the self-compactibility criteria of SCLC containing EPS. The nano-SiO2 addition has some negativeeffects on the fresh self-compacted concrete (SCC), but this is to be less for EPS mixtures. While, theslump flow of SCLC containing EPS decreased up to 6% by reducing the given W/B ratio, T50 and V-funneltimes increased in the ranges of 23–29% and 18–48%, respectively. EPS inclusion in SCC shows an increasein the slump flow retention up to 17%. Additionally, by using nonlinear multiple regression, the slumpflow with hauling time can be accurately predicted.

� 2011 Elsevier Ltd. All rights reserved.

1. Introduction

The traditional vibrated concrete produces differential compac-tion and hence differential durability. This aspect coupled withshortage of skilled workmen and noisy nature of vibrated concretewere the factors which forced to develop a new type of high perfor-mance concrete, namely self-compacted concrete (SCC). The mainrequirements of fresh SCC are filling ability, passing ability andvery high segregation resistance. SCC contains powder materialas constituent in addition to the traditional concrete materials.Therefore, in general, the density of SCC seems to be higher thanthe density of normal concrete [1,2].

Use of lightweight aggregates in the production of concrete candecrease the self-weight of structures. This can result in reducedmembers’ sections and, therefore, it will save on overall construc-tion costs. Lightweight aggregates are generally classified either asnatural or artificial. Expanded polystyrene (EPS) beads are a type ofartificial ultra-lightweight non-absorbent aggregate [3]. Polysty-rene is a thermoplastic polymeric material initially in the solidform and it can be expanded by the use of steam and expansiveagents transform to EPS beads. EPS aggregates are commerciallyavailable worldwide and have a closed cell structure consistingessentially of 98% air.

ll rights reserved.

: +98 1316690271.andoust).

The main problem associated with lightweight aggregates isthat these porous aggregates absorb a large quantity of the mixingwater. This absorption by the aggregate will mean that additionalwater will be required to maintain the workability at acceptablelevels. Hence, higher cement content will be necessary withoutany increase in strength. For this case, non-absorbent, artificial ul-tra-lightweight EPS aggregate can be suitable [4–9].

Noticeable problems associated with unsuitable vibration oflightweight concrete was reported for the inefficient distributionof lightweight aggregates, especially EPS aggregate [8,10]. This willtend to move the lightweight aggregate to the surface of concreteand forms a weak layer. To have all benefits of lightweight aggre-gate concrete, self-compacted lightweight concrete (SCLC) thatdoes not need any vibration seems to be an efficient choice to over-come these problems [11]. Providing that SCLC is compacted underits self-weight without any compaction, it is necessary to compro-mise between self-compactibility and weight of SCLC. So, the pri-mary objective of the present study is to provide informationabout the balance between self-compactibility and weight of SCLCcontaining EPS.

Earlier studies have been focused on EPS aggregate usage in or-dinary mortar or concrete for both structural and non-structuralapplications [4–9]. Some authors studied the behavior of EPS con-crete containing supplementary cementitious materials [4,7]. Ef-fect of EPS aggregate size on concrete strength and moisturemigration characteristics has been presented by Babu et al. [5].The durability of EPS lightweight concrete was reported by Babu

Page 2: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

Table 1Chemical composition and physical properties of ordinary Portland cement, silicafume and nano-SiO2.

Cement Silica fume Nano-SiO2

Chemical composition (%)SiO2 21.46 91.7 99.9Al2O3 5.55 1 –Fe2O3 3.46 0.9 –CaO 63.95 1.68 –MgO 1.86 1.8 –SO3 1.42 0.87 –K2O 0.54 – –Na2O 0.26 0.1 –LOI – 2 0.1

Physical propertiesSpecific gravity 3.15 2.12Specific surface (m2/g) 0.33 20 160Particle size 13 (lm) 0.1 (lm) 15 (nm)

3722 R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731

and Babu [4,6]. Regarding to extremely lightweight and hydropho-bic nature of EPS aggregates, it tends to float. This can result in apoor mix distribution and segregation, necessitating the use ofbonding additives [12]. Chen and Liu [9] showed that incorporatingfine silica fume, instead of bonding additives can improve the dis-persion of EPS in the matrix and the interfacial bonding strength.Furthermore, an experimental investigation and modeling wereconducted by Miled et al. [13] to evaluate the effect of particle sizeson the compressive strength of EPS concrete. The compressivestrength of lightweight concrete containing EPS has been reportedto be higher than those obtained for vermiculite or perlite concrete[14], but still its strength gain is a main objective which must beconsidered for structural lightweight concrete. This weakness ofEPS aggregates can be compensated either by reducing W/B ratioor using advanced nanotechnology development such as nano-SiO2 considered in this study. These procedures which increasethe compressive strength, can mainly affect the workability ofthe cement matrix. So, the secondary objective of this study is tofind the effect of these two procedures on the workability of SCLCcontaining EPS aggregates.

Nano-SiO2 is recently receiving special attention because of itsbetter performance when compared with traditional mineral addi-tions. Qing et al. [15] reported that the compressive strength ofhardened cement paste and bond strength of paste–aggregateinterface containing nano-SiO2 were remarkably higher than thoseobtained for mixtures containing silica fume, especially at earlyages. Jo et al. [16] reported that the addition of nano-SiO2 behavesas an activator to promote pozzolanic reaction. Li [17] found thatnano-SiO2 can enhance both short-term and long-term strengthsof high-strength concrete containing high-volume fly ash. Ji [18]indicated that with nano-SiO2 addition, the water permeabilityresistant capacity of concrete can be improved. At the fresh-statepoint of view, Senff et al. [19] reported that nano-SiO2 additionleads to lower fresh apparent density. Their results also concludedthat nano-SiO2 addition reduces the setting time and the beginningof the acceleration period of cement hydration. Diamantonis et al.[20] evaluated the effect of nano-SiO2 as additives on the viscosityof SCC. This study focused on the performance of nano-SiO2 onSCLC containing EPS as the available information is not adequatein this area.

To attain the scopes of this study, the characterization of SCLCcontaining EPS was evaluated at fresh-state. Several tests such asslump flow, T50, visual segregation index (VSI), V-funnel andL-box were conducted to assess the workability of the matrix. Tosimulate the real-world applications, the slump flow values weremeasured at different hauling times. Furthermore, linear and non-linear regression analysis has been carried out to predict howslump flow changes with hauling time.

2. Experimental plan

2.1. Materials

Type I ordinary Portland cement complying with the requirement of ASTM C150 was used. Silica fume was used to improve segregation resistance. Nano-SiO2

with 1.3 g/cm3 density has been used in this study. The chemical compositionsand physical properties of cement, silica fume and nano-SiO2 are given in Table 1.Two types of commercial spherical EPS were used as replacement of fine and coarseaggregates equally at required volume percentages. River sand with fineness mod-ulus of 2.83 and crushed gravel were used as natural aggregates. Fine and coarseaggregate properties are shown in Table 2. Polycarboxylic ether based high rangewater reducer (HRWR) namely Glenium51 with density between 1.06 and 1.08 g/cm3 (at 20 �C) was used to enhance the flowability of the mixtures.

2.2. Mixture proportion

The SCLC mixtures were designed in three groups which defined as G1, G2 andG3. In the first concrete group (G1), the W/B ratio was 0.44 and no nano-SiO2 wasemployed. To keep slump flow in a desired range, HRWR dosage was adjusted from

2.5 to 4 kg/m3. The natural aggregates were partially replaced with EPS aggregateswith 10%, 15%, 22.5% and 30% by volume in order to produce structural SCLC havingcompressive strength above 17 MPa. This range was established to meet theserequirements on the basis of preliminary studies. In the case of second concretegroup (G2), the W/B ratio was 0.44 and nano-SiO2 was replaced 2.7% by weightof the total cementitious materials. To assess the effect of nano-SiO2 on the freshSCLC, the HRWR and EPS contents were considered to be the same as the first con-crete group. In the third concrete group (G3), the W/B ratio was 0.38 and no nano-SiO2 was employed. The W/B ratio was adjusted to obtain a similar strength com-pared to G2 group. The HRWR and EPS contents were the same as that used forG1 group.

Considering the above groups, totally fifteen mixes were presented in Table 3 inwhich silica fume was replaced 10% by weight of the total cementitious materials.Silica fume was considered as additive in order to improve the bonding betweenEPS and the cement paste and to ensure proper resistance to segregation.

For mix preparation, similar procedure established by Khayat et al. [21] for SCCwas used in this study. In this way, natural coarse and fine aggregates followed byEPS aggregates were homogenized for 30 s at normal mixing speed (about 18 rpm).Thereafter, adding about half of the mixing water into the mixer while mixing goeson for 1 min. The mixture was rested for 1 min so that the aggregates could absorbthe water in the mixer. Then, binder materials including cement and silica fumewere added and mixed for one more minute. The remaining water and HRWR wereintroduced to the wet mixture, while mixing was going on for 3 min. Finally, after2 min resting, mixing sequence resumed for additional 2 min. This optimum time isnecessary to disperse HRWR and stabilize viscosity. It should be emphasized thatfor mixes containing nano-SiO2 (G2), the HRWR was dissolved in water and thennano-SiO2 was added and stirred at a high speed for 2 min and subsequently wereintroduced to the mixtures.

2.3. Test procedure

The fresh concrete tests were performed according to the procedure given byEFNARC Committee [22].

Slump flow test has been proposed to assess filling ability of concrete in the ab-sence of obstructions. The slump cone was filled with concrete and the average flowdiameter for the samples was determined when the cone was lifted. Also, the slumpflow change with hauling time was measured at 8, 15, 25, 35 and 45 min. It shouldbe noted that, following the mix preparation, the agitating speed was adjusted to4 rpm until the desired hauling time was met. This low speed was chosen to simu-late the agitation of the ready-mixed concrete in the truck mixer. The procedures aconcrete truck follows upon arriving at the job site were also simulated by adjustingthe mixer speed to 18 rpm for 1 min just prior to slump flow test.

According to EFNARC [22], there are typically three slump flow classes for arange of applications which are given in Table 4. Slump flow is not a suitable factorto exactly exhibit the fresh characteristic of SCC. But, if the slump flow is kept with-in a desirable range [23–26], it is possible to evaluate the requirements of SCC. Thus,SCLC with slump flow values between 600 and 700 mm were proposed by someresearchers [24, 25]. In the present paper, this range was also considered for SCLCwith EPS.

The visual stability index (VSI) was used in relation to slump flow test as thesimplest well known method to detect stability. According to this index, self-com-pactibility of concrete is scaled into four groups between 0 (highly stable) and 3(highly unstable). After removing the slump cone, the segregation resistance ofSCLC can be inspected visually by measuring a coarse aggregate pile or the thick-ness of cement paste extended beyond the coarse aggregate.

Viscosity can be assessed by the T50 or V-funnel times. The times when thediameter of slump flow reaches 50 cm were recorded as T50. In the case of V-funneltest, as detailed in Fig. 1, it is filled completely with fresh concrete and then, its bot-

Page 3: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

Table 2Fine and coarse aggregate properties.

Components Fine aggregates Coarse aggregates

River sand EPS (type I) Crushed gravel EPS (type II)

Sieve opening Cumulative passing (%)Gradation 1/2 in. (12.5 mm) – – 92.5 100

3/8 in. (9.5 mm) – – 54.8 100No. 4 (4.75 mm) 96 96 2.7 0No. 8 (2.36 mm) 82.4 4 – 0No. 16 (1.18 mm) 68.2 0 – 0No. 30 (600 lm) 42.5 0 – 0No. 50 (300 lm) 20.7 0 – 0No. 100 (150 lm) 6.9 0 – 0

Maximum nominal size (mm) 4.75 4.75 12.5 9.5Specific gravity 2.65 0.025 2.75 0.018Bulk density (kg/m3) 1567 13.6 1638 10.4Water absorption (%) 1.3 – 0.78 –

Table 3Mix details of EPS concrete.

Mix group Mix ID Cement(kg/m3)

SF(kg/m3)

Nano-SiO2

(kg/m3)Water(kg/m3)

Total aggregates(kg/m3)

Gravel(kg/m3)

Sand(kg/m3)

EPS volume(%)

HRWR(kg/m3)

G1 SCCM 400 44 – 196 1715 800 915 0 4.0SCLCM10 400 44 – 196 1445 662 783 10 3.5SCLCM15 400 44 – 196 1310 594 716 15 3.2SCLCM22.5 400 44 – 196 1108 491 617 22.5 2.8SCLCM30 400 44 – 196 904 387 517 30 2.5

G2 SCCN 388 44 12 196 1715 800 915 0 4.0SCLCN10 388 44 12 196 1445 662 783 10 3.5SCLCN15 388 44 12 196 1310 594 716 15 3.2SCLCN22.5 388 44 12 196 1108 491 617 22.5 2.8SCLCN30 388 44 12 196 904 387 517 30 2.5

G3 SCCH 434 48 – 183 1715 800 915 0 4.0SCLCH10 434 48 – 183 1445 662 783 10 3.5SCLCH15 434 48 – 183 1310 594 716 15 3.2SCLCH22.5 434 48 – 183 1108 491 617 22.5 2.8SCLCH30 434 48 – 183 904 387 517 30 2.5

Table 4Slump flow, viscosity and passing ability classes with respect to EFNARC [22].

Class Slump flow (mm)

Slump flow classesSF1 550–650SF2 660–750SF3 760–850

Class T50 (s) V-funnel time (s)Viscosity classesVS1/VF1 62 68VS2/VF2 >2 9–25

Passing ability classesPA1 P0.8 with two rebarPA2 P0.8 with three rebar

Fig. 1. V-funnel apparatus [22].

R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731 3723

tom gate is opened. The time takes by fresh concrete to flow out of the funnel wasmeasured and recorded as the V-funnel time. On the basis of EFNARC [22], there aretwo viscosity classes which determined by V-funnel and T50 flow times (Table 4).The V-funnel test was also used to describe the stability of SCC as well as viscosityassessment.

The L-box test is utilized to determine passing ability of SCC when flowingthrough confined or reinforced areas. The L-box test consists of an L-shaped appa-ratus in which the vertical part is filled with 12 L of concrete without any compac-tion. A gate between the horizontal and vertical parts of the L-box is lifted up andthe concrete passed through three 12 mm-diameter steel bars separated by 40 mmclear spacing. The ratio of the height of concrete remaining at the leading edge inthe horizontal section to that in the vertical section h2/h1 is an indication of thepassing ability of concrete through obstacles. The passing ability classificationsaccording to EFNARC [22] were presented in Table 4.

To assess the 28-days compressive strength development, mixtures were cast inthe 100 mm cubic molds. The specimens were demolded after 24 h of casting andstandard water curing regime were applied until the testing day.

3. Results and discussions

The characterization of the fresh SCLC containing EPS was stud-ied and the results were summarized in Table 5.

3.1. Slump flow

The effect of EPS percentage on the slump flow value and HRWRcontent are presented in Fig. 2. From this figure, it can be seen thatthe slump flow values for different concrete groups were in the

Page 4: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

Table 5Workability test results after mixing.

Mix group Mix ID EPS volume (%) Fresh concrete density (kg/m3) Slump flow (mm) T50 (s) V-funnel (s) L-box (blocking ratio) Eyes observation

G1 SCCM 0 2424 645 2.0 6.2 0.92 No segregationSCLCM10 10 2185 650 2.1 8.0 0.95 No segregationSCLCM15 15 2040 645 2.2 9.5 0.90 No segregationSCLCM22.5 22.5 1896 660 2.3 11.8 0.90 No segregationSCLCM30 30 1712 680 2.4 13.6 0.83 Slight segregation

G2 SCCN 0 2392 620 2.5 8.2 0.89 No segregationSCLCN10 10 2187 615 2.5 10.7 0.93 No segregationSCLCN15 15 2105 625 2.5 12.2 0.88 No segregationSCLCN22.5 22.5 1898 640 2.6 14.2 0.87 No segregationSCLCN30 30 1701 660 2.8 15.7 0.81 No segregation

G3 SCCH 0 2518 600 2.6 10.9 0.87 No segregationSCLCH10 10 2235 610 2.6 11.7 0.89 No segregationSCLCH15 15 2077 615 2.7 14.1 0.88 No segregationSCLCH22.5 22.5 1919 630 2.9 14.9 0.81 No segregationSCLCH30 30 1748 640 3.1 16.1 0.78 No segregation

600

620

640

660

680

700

0 10% 15% 22.50% 30%

EPS in vol.

Slum

p flo

w (m

m)

2

2.5

3

3.5

4

4.5

HR

WR

(kg/

m3 )

Slump flow (G1,W/B=0.44,NS=0)

Slump flow (G2,W/B=0.44,NS=12)

Slump flow (G3,W/B=0.38,NS=0)

HRWR

Fig. 2. Variation of slump flow and HRWR vs. EPS volume for different concrete groups.

3724 R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731

range of 600–680 mm. This figure also indicates that requiredHRWR dosage decreased with an increase in EPS volume. A slumpflow increasing trend can be seen in Fig. 2, when the EPS content isincreased. This could be explained by hydrophobic nature of EPSaggregates and the lower internal friction resulting from thereplacement of angular aggregates by EPS with spherical shapeand relatively smooth surface. However, a similar tendency hasnot been detected for SCLCN10 (G2 group) and SCLCM15 (G1group) mixes which might be due to the application of constantHRWR for all mixes at each EPS percentage.

For mixes on G2 group (with nano-SiO2), at a given EPS percent-age, the slump flow reduced as compared with those obtained formixes on G1 group (Fig. 2). For instance, the slump flow value forSCCM was measured at 645 mm, whereas this value was foundto be 620 mm for SCCN. This clearly shows that the use of nano-SiO2 is detrimental to flowability of mixture. This observation isin agreement with those obtained by Senff et al. [19] conductedon ordinary mortars. The nano-SiO2 addition in matrix needs high-er amount of water or HRWR to preserve the slump flow [19]. If thewater content or HRWR dosage is kept constant, an increase ofnano-SiO2 content will promote the packing of particles and

decreasing the free water. Therefore, there is a higher internal fric-tion which resulted in decreasing the flowability. However, thesame pattern was not reported by Maghsoudi and Arabpour [27].Nevertheless, this reduction was found to be lower for mixes con-taining EPS.

For similar EPS content, the slump flow of mixes increased withincreasing W/B ratio, as seen in Fig. 2. This may be due to the in-crease in the lubrication between the fine particles which resultedin reducing the yielding stress and better flowability.

In Fig. 3, the relative slump flow vs. EPS content is presented forall groups. Although the slump flow for G2 and G3 groups are low-er than G1group, it is clearly shown that the influence of W/B ratioto be more detrimental than the addition of nano-SiO2 on slumpflow reduction.

3.2. Slump flow retention

The elapsed time from the first contact of water and cement tothe time when concrete is placed is described as hauling time[28]. The slump flow changes were measured at four hauling timesof 15, 25, 35 and 45 min. The results were compared with slump

Page 5: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

84

88

92

96

100

104

108

0 10% 15% 22.50% 30%EPS in vol.

Rel

ativ

e sl

ump

flow

(%) G1 G2 G3

Fig. 3. Relative slump flow vs. EPS in vol.

R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731 3725

flow values determined immediately after mixing, as indicated inFigs. 4–7. Accordingly, regardless of concrete compositions, theslump flow decreased with the increasing hauling time. The mech-anism of slump flow reduction with hauling time has been estab-lished by several researchers [29–31]. This mechanism can be dueto: (i) the adsorption of superplasticizer on the cement hydratedproduct, (ii) the stiffness of matrix due to growth of hydration prod-uct, (iii) the additional fines brought to the concrete matrix by thegrinding of aggregates and (iv) a reduction in the mixing water byevaporation. It should be noted that, for full-scale ready-mix pro-duction, factors such as mixing procedures and time may becomeimportant and would need to be assessed for the particular plant.

400

450

500

550

600

650

700

0 5 10 15 20Hauling

Slum

p flo

w (m

m)

Fig. 4. Slump flow vs. hauling tim

400

450

500

550

600

650

700

0 5 10 15 20Hauling

Slum

p flo

w (m

m)

SCCM SCLCM10 SC

Fig. 5. Slump flow vs. hauling t

In general, the SCC with slump flow value lower than 500 mmcannot completely pass through the highly dense reinforcement[32]. Therefore, as illustrated in Fig. 4, SCCN and SCCH mixes couldnot technically be categorized as SCC after 25 and 35 min of haul-ing times, respectively. In addition, because of high pozzolanicactivity of nano-SiO2, the highest slump flow losses resulted forSCCN. This behavior could be regarded as the weak point ofnano-SiO2 in SCC.

It should be noted that different additions have different effectson slump flow losses [33–35]. In this study, the slump flow reten-tion using silica fume turned out to be 77% after 45 min of haulingtime, whereas Ghafoori and Barfield [28] reported that the slump

25 30 35 40 45 50time (min)

w/b=0.44, NS=0w/b=0.44, NS=12w/b=0.38, NS=0

e for mixtures without EPS.

25 30 35 40 45 50 time (min)

LCM15 SCLCM22.5 SCLCM30

ime for G1 concrete group.

Page 6: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

400

450

500

550

600

650

700

0 5 10 15 20 25 30 35 40 45 50Hauling time (min)

Slum

p flo

w (m

m)

SCCN SCLCN10 SCLCN15 SCLCN22.5 SCLCN30

Fig. 6. Slump flow vs. hauling time for G2 concrete group.

400

450

500

550

600

650

700

0 5 10 15 20 25 30 35 40 45 50Hauling time (min)

Slum

p flo

w (m

m)

SCCH SCLCH10 SCLCH15 SCLCH22.5 SCLCH30

Fig. 7. Slump flow vs. hauling time for G3 concrete group.

3726 R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731

flow retention of 77% can be attained after 60 min of hauling timefor SCC containing fly ash.

As indicated in Figs. 5–7, EPS inclusion in SCC shows an increasein the slump flow retention up to 17%. This may be due to higherfree water content in matrix or relatively smooth surface textureof EPS aggregates. These characteristics of EPS aggregates couldovercome the weak point of the nano-SiO2 application in SCC asseen in Fig. 6.

The slump flow values for all mixes with hauling time were pre-sented in Fig. 8. The weak correlation coefficient (R2 = 0.63) indi-cate no single variable can adequately explain how the slumpflow changes with hauling time. For this purpose, linear multipleregression technique (LMRT) and nonlinear multiple regression

400

450

500

550

600

650

700

0 5 10 15 20Hauling

Slum

p flo

w (m

m)

Fig. 8. The change in slump flow

technique (NLMRT) were performed. Obviously, there are severalparameters which can affect the slump flow retention. For the pur-pose of this study, the effect of mixture compositions was of pri-mary interest and other factors such as atmospheric temperature,chemical materials, mixing sequence and non-uniform dopinghave not been included. Hence, polynomial regression equationswith input parameters, namely, W/B ratio (WB), nano-SiO2 content(NS), hauling time (T) and EPS percentage (EPS) were developed toestimate the slump flow (SF) as output. Among 65 sets of data pat-terns, 33 sets of data were randomly selected as a data base to trainthe regression equations. The remaining was employed to test theaccuracy of the proposed models in the prediction of the slumpflow values. Various polynomial equations were tried and the best

SF = 838.68T -0.1368

R2 = 0.6305

25 30 35 40 45 50time (min)

with respect to hauling time.

Page 7: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731 3727

equations were determined by considering related R2. The detail ofthe best LMRT and NLMRT equations are given as Eqs. (1) and (2),respectively.

SF ¼ 166:58� 5:596� NSþ 1180:56�WB� 4:383� T

þ 1:681� EPS ð1Þ

SF ¼ 150:395� 2:999� NSþ 1202:531�WB� 4:086� T

þ 0:067� EPS2 � 0:140� NS� Tþ 0:516� T�WB ð2Þ

Statistical parameters of LMRT and NLMRT were summarized inTable 6. Additionally, to observe the relative performances of LMRTand NLMRT in detail, scatter plots for these two regression modelsare presented in Figs. 9 and 10. Referring to Figs. 9 and 10, discrep-ancies from the line of equality in NLMRT and LMRT are very smallbut NLMRT shows a slightly better performance in prediction ofslump flow values.

3.3. T50

As shown in Table 5, the T50 flow times are ranging from 2 to 3.1s. The differences are very less but it can be concluded that T50 washigher for the mixture containing higher EPS in volume. This find-ing was confirmed by Mazaheripour et al. [26] for SCLC containinglightweight expanded clay aggregates. By comparing the results ofG1 and G2 groups, at a given EPS percentage, it is observed thatnano-SiO2 addition leads to higher T50 time which can be expectedto improve the segregation resistance. The higher T50 flow times of

Table 6Statistic comparison between LMRT and NLMRT.

St. tech. R2 Mean relative error(%)

Maximum relative error(%)

LMRT Training 0.909 2.71 5.84Testing 0.901 2.86 9.05

NLMRT Training 0.947 1.99 4.27Testing 0.914 2.73 5.22

450

500

550

600

650

700

750

450 500 550 6

Target slum

Pred

icte

d sl

ump

flow

(mm

)

Training data set, R2 = 0.909

Testing data set, R2=0.901

Fig. 9. Comparison of target and predicted

mixtures with lower W/B ratio (G3 group) indicate a higher plasticviscosity.

3.4. Visual Stability Index Test (VSI)

For each concrete mixture, segregation and bleeding were visu-ally inspected during the slump flow test. Generally, after mixing, aVSI of 0 or 1 (stable matrix) were attained for all mixes except forSCLCM30 in G1 group. For this mix, segregation of EPS due to buoy-ancy was detected on the surface of concrete (Fig. 11). In addition,due to low plastic viscosity of this mix, EPS segregation was alsodetected near the edges of the spread-out concrete. This segrega-tion can be reduced either by applying nano-SiO2 or by loweringW/B ratio.

3.5. V-funnel test

The effect of EPS on slump flow and V-funnel time are illus-trated in Figs. 12–14. From these figures, it can be seen that theV-funnel time for different concrete groups were in the range of6.2–16.1 s. For all concrete groups, the greater EPS volume, thelonger V-funnel time was recorded. For instance, SCCM had a V-funnel time of 6.2 s which increased to 13.6 s as EPS introducedup to 30% by volume. By increasing the EPS percentage, the unitweight will decrease. Hence, the self-compactibility of concretecannot be achieved completely by its dead weight which will be re-sulted a higher V-funnel time [36]. A similar conclusion was alsoobserved by other researchers. Kim et al. [24] reported that theV-funnel time was mostly increased to some extent when naturalcoarse aggregates were replaced by lightweight aggregates. Choiet al. [25] also showed that the V-funnel times increased withincreasing the proportion of lightweight fine aggregates. As evidentfrom Figs. 12 and 13, the incorporation of nano-SiO2 increased theV-funnel times of the SCLC containing EPS. Regarding the effect ofW/B ratio, the V-funnel times of G3 mixes group (W/B = 0.38) areabout 18–48% higher than that of G1 group (W/B = 0.44) dependingon the EPS content. Similar tendency has been reported by Feleko-glu et al. [23] for SCC.

00 650 700 750

p flow (mm)

slump flow by means of LMRT model.

Page 8: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

450

500

550

600

650

700

750

450 500 550 600 650 700 750

Target slump flow (mm)

Pred

icte

d sl

ump

flow

(mm

)

Training data set, R2=0.947

Testing data set, R2=0.914

Fig. 10. Comparison of target and predicted slump flow by means of NLMRT model.

Fig. 11. Slump flow appearance for SCLCM30.

590

610

630

650

670

690

0 10% 15%EPS in

Slum

p flo

w (m

m)

Slump flowV-funnel time

Fig. 12. Variation of EPS vol. on slum

3728 R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731

3.6. L-box test

The results from the L-box test are presented graphically inFig. 15. The L-box blocking ratio of SCLC containing EPS changedfrom 0.95 to 0.78. According to the results, the highest blocking ra-tio was achieved for SCLCM10 and the lowest for SCLCH30. FromFig. 15, it can be seen that for 10% replacement of EPS in all mixes,the blocking ratio increases. Such behavior may be attributed tothe replacement of angular aggregates by EPS with spherical shapeand relatively smooth surface. But, as EPS replacement increases bymore than 10%, it seems that there will be a decrease in the passingability of the fresh concrete through the space between the steelbars. This may be explained by the fact that the undesirable effectof self-weight of EPS aggregate dominates the effect of its surfacecharacteristic.

3.7. Compressive strength

The 28-days compressive strength of SCLC is shown in Fig. 16.From this figure, adequate structural compressive strength (above

22.50% 30%vol.

4

6

8

10

12

14

16

18

V-fu

nnel

tim

e (s

ec)

p flow and V-funnel time for G1.

Page 9: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

570

590

610

630

650

670

690

0 10% 15% 22.50% 30%EPS in vol.

Slum

p flo

w (m

m)

4

6

8

10

12

14

16

18

V-fu

nnel

tim

e (s

ec)Slump flow

V-funnel time

Fig. 13. Variation of EPS vol. on slump flow and V-funnel time for G2.

550

570

590

610

630

650

670

690

0 10% 15% 22.50% 30%EPS in vol.

Slum

p flo

w (m

m)

4

6

8

10

12

14

16

18

V-fu

nnel

tim

e (s

ec)

Slump flowV-funnel time

Fig. 14. Variation of EPS vol. on slump flow and V-funnel time for G3.

0.7 0.75 0.8 0.85 0.9 0.95 1

SCCM (G1)

SCLCM10 (G1)

SCLCM15 (G1)

SCLCM22.5 (G1)

SCLCM30 (G1)

SCCN (G2)

SCLCN10 (G2)

SCLCN15 (G2)

SCLCN22.5 (G2)

SCLCN30 (G2)

SCCH (G3)

SCLCH10 (G3)

SCLCH15 (G3)

SCLCH22.5 (G3)

SCLCH30 (G3)

Blocking ratio

Fig. 15. Blocking ratio of different mixes.

R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731 3729

17 MPa) was achieved for all mixes. The increase in the EPS contentresults in a significant reduction in compressive strength for all

concrete groups. Considering the G1 and G2 groups, the positiveinfluence of nano-SiO2 can be seen on the compressive strength re-

Page 10: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

0

10

20

30

40

50

60

0 10% 15% 22.50% 30%EPS in vol.

Com

pres

sive

str

engt

h (M

Pa)

G1 G2 G3

Fig. 16. Compressive strength of different concrete groups.

3730 R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731

sults. But, its influence turned out to be lower as EPS aggregate wasintroduced.

3.8. Acceptance criterion of self-compactibility of SCLC containing EPS

There is yet no fully recognized standard for characterization offresh SCC, especially for SCLC. Nonetheless, some specificationswere employed in literatures [24–26]. On the basis of the author’sown experience, the following criteria for satisfactory self-com-pacting behavior may be adopted for SCLC with EPS.

3.8.1. Slump flowMixes with slump flow values between 600 and 660 mm were

accepted. These values are mostly within the EFNARC criteria class1. Mixtures with a slump flow higher than this criterion show asign of segregation.

3.8.2. T50

Mixtures with a T50 time higher than 2 s can be considered as anacceptable for SCLC design containing EPS. Most of the mixturesfulfill EFNARC VS2 specifications.

3.8.3. V-funnelIn some technical literature [11,24–26], the V-funnel times of

SCLC were restricted based on EFNARC or JSCE specifications. How-ever, the results of this study concluded that it was not possible torestrict the V-funnel time into limited values to produce a self-compactable and stable SCLC containing EPS. For instance, the V-funnel time of 16.1 s is enough for SCLCH30 with W/B = 0.38 to at-tain stable mixture. While, the V-funnel time of 13.6 s for SCLCM30with W/B = 0.44 is not enough. It should be remembered that theseresults satisfy the requirements specified by EFNARC VF2 or JSCER2.

3.8.4. L-boxMixtures with L-box ratios between 0.8 and 1 appear to be

acceptable. These values are within the EFNARC criteria PA2. Basedon this judgement, SCLCH30 concerning to G3 group was rejected.

In general, the mixtures with density higher than 1900 kg/m3

(up to 22.5% of EPS by vol.) satisfy the fresh-state behavior require-ments related to high segregation resistance, deformability, pass-ing and filling abilities. Moreover, by applying the nano-SiO2, allstructural SCLC containing EPS with density below 1900 kg/m3

may be accepted.

4. Conclusion

In this paper the fresh properties of SCLC containing EPS aggre-gates were evaluated and the following conclusions can be drawn:

(1) All mixes were designed to have slump flow values between600 and 700 mm attained by adjusting the high range waterreducer dosage. Using EPS decreased the high range waterreducer demand while higher slump flow was achieved.

(2) The segregation tendency of EPS aggregates can be seen inmixtures with the density lower than 1900 kg/m3 whichcan be reduced by applying nano-SiO2.

(3) The highest rate of slump flow losses resulted for mixes con-taining nano-SiO2. In addition, the slump flow losses forSCLC containing EPS were observed to be lower than ordin-ary SCC.

(4) Linear and nonlinear multiple regression techniques can besuccessfully employed to predict the slump flow retention.However, nonlinear multiple regression technique exhibitsslightly better performance.

(5) Using EPS aggregates increased both V-funnel and T50 times.Moreover, the nano-SiO2 addition or decreasing W/B ratioleads to higher V-funnel or T50 times which indicated higherviscosity.

(6) The passing ability of mixes reveals that, whereas the block-ing ratio increases for 10% replacement of EPS, it decreasesfor the higher percentage of EPS replacement.

(7) The addition of nano-SiO2 seems to have less negative effecton workability of SCLC containing EPS than W/B ratioreduction.

(8) The compressive strength test results revealed that the useof the EPS aggregates remarkably decreased the compressivestrength of SCLC. Moreover, the influence of nano-SiO2 onstrength gain was also detected.

(9) In general, SCLC containing EPS with the density higher than1900 kg/m3 (up to 22.5% of EPS by volume) meets the fresh-states behavior requirements of concrete.

References

[1] Persson B. A comparison between mechanical properties of self-compactingconcrete and the corresponding properties of normal concrete. Cem Concr Res2001;31:193–8.

[2] Topçu IB, Bilir T, Uygunoglu T. Effect of waste marble dust content as filler onproperties of self-compacting concrete. Constr Build Mater 2009;23:1947–53.

[3] Sussman V. Lightweight plastic aggregate concrete. ACI J 1975(July):321–3.[4] Babu KG, Babu DS. Behaviour of lightweight expanded polystyrene concrete

containing silica fume. Cem Concr Res 2003;33:755–62.[5] Babu DS, Babu KG, Tiong-Huan W. Effect of polystyrene aggregate size on

strength and moisture migration characteristics of lightweight concrete. CemConcr Compos 2006;28:520–7.

[6] Babu KG, Babu DS. Performance of fly ash concretes containing lightweight EPSaggregates. Cem Concr Compos 2004;26:605–11.

[7] Babu DS, Babu KG, Wee TH. Properties of lightweight expanded polystyreneaggregate concretes containing fly ash. Cem Concr Res 2005;35:1218–23.

[8] Sri Ravindrarajah R, Tuck AJ. Properties of hardened concrete containingtreated expanded polystyrene beads. Cem Concr Compos 1994;16:273–7.

Page 11: An Investigation on the Fresh Properties of Self-compacted Lightweight Concrete Containing Expanded Polystyrene

R. Madandoust et al. / Construction and Building Materials 25 (2011) 3721–3731 3731

[9] Chen B, Liu J. Properties of lightweight expanded polystyrene concretereinforced with steel fiber. Cem Concr Res 2004;34:1259–63.

[10] Madandoust R. Strength assessment of lightweight concrete. PhD thesis,Liverpool University; 1990.

[11] Wu Zh, Zhang Y, Zheng J, Ding Y. An experimental study on the workabilityof self-compacting lightweight concrete. Constr Build Mater 2009;23:2087–2092.

[12] Cook DJ. Expanded polystyrene concrete. In: Swamy RN, editor. New concretematerials. Concrete technology and design, vol. 1. Surrey University Press;1983. p. 41–69.

[13] Miled K, Sab K, Le Roy R. Particle size effect on EPS lightweight concretecompressive strength: experimental investigation and modeling. Mech Mater2007;39:222–40.

[14] Sussman V, Baumann GH. Expanded polystyrene beads lighten the load. SocPlast Eng J 1972;28:18–21.

[15] Qing Y, Zenan Zh, Deyu K. Rongshen Ch. influence of nano-SiO2 addition onproperties of hardened cement paste as compared with silica fume. ConstrBuild Mater 2007;21:539–45.

[16] Jo BW, Kim CH, Tae Gh, Park JB. Characteristics of cement mortar with nano-SiO2 particles. Constr Build Mater 2007;21:1351–5.

[17] Li G. Properties of high-volume fly ash concrete incorporating nano-SiO2. CemConcr Res 2004;34:1043–9.

[18] Ji T. Preliminary study on the water permeability and microstructure ofconcrete incorporating nano-SiO2. Cem Concr Res 2005;35:1943–7.

[19] Senff L, Labrincha JA, Ferreira VM, Hotza D, Repette WL. Effect of nano-silica onrheology and fresh properties of cement pastes and mortars. Constr BuildMater 2009;23:2487–91.

[20] Diamantonis N, Marinos I, Katsiotis MS, Sakellariou A, Papathanasiou A,Kaloidas V, et al. Investigations about the influence of fine additives on theviscosity of cement paste for self-compacting concrete. Constr Build Mater2010;24:1518–22.

[21] Khayat KH, Bickley J, Lessard M. Performance of self-consolidating concrete forcasting basement and foundation walls. ACI Mater J 2000;97:374–80.

[22] The European guidelines for self-compacting concrete; specificationproduction and use. EFNARC; May 2005.

[23] Felekoglu B, Turkel S, Baradan B. Effect of water/cement ratio on the fresh andhardened properties of self-compacting concrete. Build Environ2007;42:1795–802.

[24] Kim YJ, Choi YW, Lachemi M. Characteristics of self-consolidating concreteusing two types of lightweight coarse aggregates. Constr Build Mater 2010;24:11–6.

[25] Choi YW, Kim YJ, Shin HC, Moon HY. An experimental research on the fluidityand mechanical properties of high-strength lightweight self-compactingconcrete. Cem Concr Res 2006;36:1595–602.

[26] Mazaheripour H, Ghanbarpour S, Mirmoradi SH, Hosseinpour I. The effect ofpolypropylene fibers on the properties of fresh and hardened lightweight self-compacting concrete. Constr Build Mater 2011;25:351–8.

[27] Maghsoudi AA, Arabpour DF. Application of nanotechnology in self-compacting concrete design. Int J Eng 2009;22:229–44.

[28] Ghafoori N, Barfield M. Effects of hauling time on air-entrained self-consolidating concrete. ACI Mater J 2010;107:275–81.

[29] Collepardi M. Admixtures used to enhance placing characteristics of concrete.Cem Concr Compos 1998;20:103–12.

[30] Lowke D, Schiessl P. Effect of Mixing Energy on Fresh Properties of SCC. In:Proceedings of the fourth international RILEM symposium on self-compactingconcrete and second north american conference on the design and use of self-consolidating concrete, Chicago, USA; 2005.

[31] Stieb M. Mechanische Verfahrenstechnik 1. Berlin: Springer; 1995. Secondissue.

[32] Bouzoubaa N, Lachemi M. Self-compacting concrete incorporating highvolumes of class F fly ash Preliminary results. Cem Concr Res 2001;31:413–20.

[33] Sonebi M, Grünewald S, Walraven J. Filling ability and passing ability of self-consolidating concrete. ACI Mater J 2007;104:162–70.

[34] Sonebi M. Medium strength self-compacting concrete containing fly ash:modelling using factorial experimental plans. Cem Concr Res 2004;34:1199–208.

[35] Boukendakdji O, Kenai S, Kadri EH, Rouis F. Effect of slag on the rheology offresh self-compacted concrete. Constr Build Mater 2009;23:2593–8.

[36] Wang HY, Huang WL. A study on the properties of fresh self-consolidatingglass concrete (SCGC). Constr Build Mater 2010;24:619–24.