Ammonia storage and delivery systems for NOx...
Transcript of Ammonia storage and delivery systems for NOx...
![Page 1: Ammonia storage and delivery systems for NOx aftertreatmentenergy.gov/sites/prod/files/2014/03/f8/deer07_johannessen.pdf · Ammonia enabling technologies Ammonia storage and delivery](https://reader031.fdocuments.net/reader031/viewer/2022022003/5a9e12067f8b9a29228d2a54/html5/thumbnails/1.jpg)
Ammonia enabling technologies
Ammonia storage and delivery systemsfor NOx aftertreatment
Tue Johannessen, Henning Schmidt, Jakob Svagin and Jan OechsleAmminex A/S
Poster location: P21
Key issue: Reductant storage for SCR Ammonia is the active molecule Urea is currently considered as “fuel” for SCR But urea presents many challenges for LD/PC
Low capacity “Issues” in both cold and warm climate Conversion and mixing in exhaust line (deposits?) Limitation on dosing at low load / urban driving
DEER 2007 © Amminex A/S, 2007 14.09.2007
![Page 2: Ammonia storage and delivery systems for NOx aftertreatmentenergy.gov/sites/prod/files/2014/03/f8/deer07_johannessen.pdf · Ammonia enabling technologies Ammonia storage and delivery](https://reader031.fdocuments.net/reader031/viewer/2022022003/5a9e12067f8b9a29228d2a54/html5/thumbnails/2.jpg)
SCR
Muf
fler
Feed
ing
line
DPF
Ammonia stored safely in AdAmmineTM: Mg(NH3)6Cl2 (>50 wt% NH3; > 600g NH3/liter) No degradation; long shelve life 100g material sample
300% higher capacity than urea (AdBlue) Safe storage enables direct ammonia dosing for SCR
Release by controlled thermal desorption of NH3 from cartridges: AdAmmine cartridge with heater, Psensor, thermocouple Dynamic dosing from 3.5kg prototype demonstrated
7
Am
mo
nia
flo
w (
SL
PM
) FlowrateSP 6
Ammonia dosing 5
4
3
2
1
ECU 2500 liters NH3 (STP) 0
94 96 98 100 102 104 106
Time (min)
DOC System design and performance: Dosing Ammonia Storage and Delivery Systems – ASDS
Power demand for US06/FTP75 < 60W ADCU Peak flows above 10 SLPM
Electronics and control: Storage unit Algorithms for power minimization
OBD functions
DEER 2007 © Amminex A/S, 2007 14.09.2007