Ambient Temperature Correction Test for WLTP
Transcript of Ambient Temperature Correction Test for WLTP
Ambient Temperature
Correction Test for WLTP
WLTP IG Meeting, Vienna, 26-28.3.2014 Contact: [email protected]
Motivation:
In order to reflect the CO2 values obtained under “real life temperature conditions”,
an additional test is proposed to be conducted on a regional base.
For this test, the vehicle shall be soaked at a defined “regional” temperature Treg over
a defined soak/park time (tsoak). No restrictions for oil and water temperature.
The ATCT (measurement) shall be performed only once for a temperature correction
vehicle family.
AMBIENT TEMPERATURE CORRECTION TEST (ATCT) FOR WLTP.
Approach for Europe:
Typical use cases for soak time are overnight parking ~10-12h and daytime parking at work ~8h. This leads to tsoak= 9h.
Climate data derived from FAT Study (Prof. Köhler, Technical University Braunschweig, Germany)
Page 2
Page 3
Type I Test
CO2_1
CO2_2
CO2_3
Test cell, soak: 23 °C
Soak time: 6 – 36 h
Engine oil, water: 23 °C
CO2@Creg
Test cell, soak: Treg, e.g. [14] °C for EU
Soak time: tsoak, eg. [9 + 2] h for EU
Engine oil, water: no restrictions
Ambient Temperature
Correction Test
FCFCOCO ITypeATCT _2_2
IType
reg
CO
CCOFCF
_2
2 @
FCF = Family Correction Factor CO2_Type-I = TA CO2 value for Type-I test (23°C)
For one vehicle out of a family (measurement)
For all vehicles in one family (calculated value)
Vehicle Family for ATCT
CO2_ATCT = corrected CO2 value Creg = regional conditions
AMBIENT TEMPERATURE CORRECTION TEST (ATCT) FOR WLTP.
AMBIENT TEMPERATURE CORRECTION TEST (ATCT) FOR WLTP.
Road load determination
a. Correction of F0,F1,F2 to 20°C => GTR Annex 4 §4.5
b. Adjust dyno settings @ 23°C
c. Pre Con WLTC for warm up @23°C
23°C Test
14°C Test
d. Soak @23°C for 6-36h (forced cool
down) until engine oil & water = 23°C
e. WLTC with emissions measurement
a. Correction of F0,F1,F2 to 14°C => GTR Annex 4 §4.5
b. Adjust dyno settings @ 14°C
c. Pre Con WLTC for warm up @23°C
d. Soak @14°C for 9h and natural cool
down with no restrictions. Tolerance between test end and start
cool down 10 min.
Logged temperatures: engine oil &
water, soak area temperature.
e. WLTC with emissions measurement f. Soak @23°C for at least 9 h
with natural cool down.
Tolerance between test end and start
cool down 10 min.
Logged temperatures: engine oil &
water, soak area temperature.
- CO2 @ 23°C
- Cool down curves @23°C for Temperature Criteria check
CO2 @ 14°C
Selection of ATCT family representative vehicle.
Criteria:
Temperature and vehicle requirements.
CCO
CCOFCF
23@
14@
2
2
For
eac
h C
O2 fa
mily
For each A
TC
T fam
ily Family criteria check and ATCT (example for 14°C and 9h)
Page 4
The following characteristics should be equal within the family:
- temperature at the end of soak time within a tolerance of [5/10] K
- combustion process (two stroke, four stroke, rotary)
- number of cylinders
- configuration of the cylinder block (in-line, V, radial, horizontally opposed,…)
The inclination or orientation of the cylinders is not a criteria
- method of engine fuelling (e.g. indirect or direct injection)
- type of cooling system (air, water, oil)
- method of aspiration (naturally aspirated, pressure charged)
- fuel for which the engine is designed (petrol, diesel, NG, LPG, etc.)
- engine cylinder capacity of the largest engine within the family minus [20] %
Additional provisions for emissions control and heat storage systems available
AMBIENT TEMPERATURE CORRECTION TEST (ATCT) FOR WLTP.
Requirements for family criteria check:
Page 5
Vehicle FCF FCF
Test1 Test2 328xi Limo (MT) +1,8% +1,5% 320iA GT (AT) +2,0% +1,4%
ACEA proposal [5]K absolute temperature tolerance
)23@(1
)14@(
2
2
CCOType
CCOATCTFCF
Vehicle Engine coolant temperature
@23°C, 9h Test1 Test2
328xi Limo (MT) T_amb+8.8 T_amb+6.4 320iA GT (AT) T_amb+7.3 T_amb+5.7
ΔT=3.1K
AMBIENT TEMPERATURE CORRECTION TEST (ATCT) FOR WLTP.
PSA results show similar behavior.
Check, if ATCT family temperature
criteria is met.
ATCT at Treg=14°C and tsoak=9h
Page 6
ATCT FOR PHEVS?
The correction is complex and requires significant lab ressources:
Correction of Charge Sustaining CO2 value: possible (like ICE)
Correction of electric range for Utility Factor and CO2: ?
Page 7
ATCT FOR PHEVS IN WLTP. ATCT IMPACT ON THE ELECTRIC RANGE OF CD TEST.
Example PHEV
(40km eRange, 100g CO2/km)
-3% @ 40 km electric
range
+
Shift in UF curve
ΔCO2 ≤ 1 g/km
For i3 Range Extender, the influence
would be <<1g/km CO2
UF
[%
]
Electric Range [km]
10
30
20
40
50
60
70
80
90
100
10 30 20 40 50 60 70
Type I
@ 23°C charging
@ 14°C / 9h
ATCT
@ 14°C -3% eRange
BMW i3 Range Extender
Page 8
ATCT FOR PHEVS IN WLTP.
ACEA proposal for ATCT and PHEVs :
Correction of Charge Sustaining according to ICE procedure
No correction of e-Range and UF.
Page 9
Status and Summary:
Detailed proposal for ATCT Procedure drafted by Audi/BMW.
Validation tests successfully conducted at BMW and PSA.
For PHEV, only Charge Sustaining CO2 shall be temperature corrected.
AMBIENT TEMPERATURE CORRECTION TEST (ATCT) FOR WLTP.
Page 10