u 32 Hardwired zones / 8 Areas / 64 User codes
u 3 x 256 Events log stamped with date and time
u On-board voice dialer
u Macro functionality
u USB direct connection
The intrusion alarm system AMAX panel 3000 EN isdesigned for residential and small to medium-sizedbusinesses. It offers 32 zones and 8 areas and comeswith an enclosure and a transformer. An on-boardPSTN dialer transmits an alarm via the commontelephone network to a phone and/or acommunication center while at the same time a voicemessage is sent to the owner’s landline or mobilephone to inform him about an intruder’s presence.Commissioning the system is simple and involvesminimum programming: the default settings alreadycover 90 % of the available functionality. Programmingcan either be done via the AMAX TEXT, LCD and LEDkeypads or via the programming software (A-LinkPlus).The intrusion system can be used with both RADIONwireless peripherals, operating at 433 Mhz andhardwired detectors from Bosch.
System overview
Phone
Option Bus
AMAX panel 3000 EN
CMS Programming SW
A-Link Plus
P S T NTelephone
Network
Functions
AMAX panel 3000 EN is a 32 zone / 8 area intrusioncontrol panel with enclosure and transformer. Thesystem includes a PSTN dialer to transmit an alarm viathe common telephone network. An alarm can betransmitted to a phone and a communication center.Program the control panel easily with the AMAX TEXT,LCD and LED keypads or via the remote programmingsoftware, A-Link Plus.
Basic functions• Keypad Code STAY / AWAY Arming• One Button STAY / AWAY Arming• On-board dialer with CID / SIA transmission format.
Voice dialer transmits up to 4 recorded messages tolandline/mobile phones in case of an alarm. Recordmessages with a PC and send to the control panelwith the remote programming software, A-Link Plus.
• Program up to 16 weekly schedules and exceptions inthe calendar.
• 3 programmable macros: several single functionsfrom the keypad are combined to one customermacro function. Execute by pressing one button.
• Program the control panel with the new release ofremote programming software, A-Link Plus. All controlpanel and status information are accessible.
• Execute remote maintenance operations (eg. WalkTest, Bypass)
• In multi-area set-up (direct and multiple arming),“area status” is displayed.
• Display Area Name in the master keypad• 3 on-board outputs (two monitored)• Use any zone with four-wire fire detectors• Use any zone for Chime Mode (Door Bell)• Use any zone to detect Sensor Tamper (DEOL)• Test Mode for outputs and zones
Optional functions• Wireless devices (433 MHz) RADION from Bosch• Zone inputs on extension modules (with DX2010)• Relay outputs on extension modules (with DX3010)• Connect outdoor sirens and IP cameras to an optional
8 relay module (DX3010)• Programming key
Optional Alarm Transmission• IP communication with Bosch Conettix IP / SIA DC09
(UDP) Protocol via B426 module• GPRS communication with Bosch Conettix IP l / SIA
DC09 (UDP) Protocol via B450 module
Optional Remote Programming• IP (B426 module)• GPRS (B450 module)
Optional Video Alarm VerificationOptional video alarm verification is possible incombination with DX3010 8 relay module and IP 200camera series of Bosch. The live video verificationensures a location check and false alarm reduction viaInternet from every location worldwide. This meansthat you or the monitoring center can get alarm
notification in order to detect the exact location wherethe alarm was triggered and if a real intruder ispresent.
Compatibility Information
Basic
PSTN Communicator (Integrated) Formats:Contact ID, SIA
Magnetic Contacts (1) All magnetic contacts, includingrecessed, terminal connection,miniature over-head door, andsurface mount.
Intrusion Detectors (1) All conventional intrusiondetectors, including Blue Line,seismic, PIR, TriTech,photoelectric and TriTech PIRMicrowave.
Four-wire Smoke Detectors (1, 2) Conventional 12V smoke, heatand photoelectric smokedetectors.
Optional (1, 2)
Zone DX2010 zone input module
Relays DX3010 output module
IP-Communicator B426 Ethernet Network InterfaceModule
GPRS/GSM Communicator B450 Module
Assorted literature is available. Refer to theappropriate datasheet, brochure, and installationguide for additional data.Availability varies according to sales region.
Certifications and approvals
Region Certification
Europe CE DIN EN 50130-4 (6/2011)DIN EN 55022 (5/2008)EN 60950-1:2006 + A11:2009+ A1:2010
EN EN 50131-3 Grade 2EN 50136 ATS 2Environmental Class 2
Germany VDS Home
Sweden SSF 1014 Edition 4 Class 1
France AFNOR NF a 2pEnvironmental class 1
2 | AMAX panel 3000 EN
Parts included
CTN Pcs Description
AMAX panel 3000 EN 1 32 zone / 8 areas intrusion panelwith enclosure and transformer,tamper, integrated PSTNCommunicator
1 User Guide, multilingual
Technical specifications
Panel
Enclosure:
Dimensions (HxWxD): • 260 x 280 x 83,5 mm(L x W x H)
Weight: • 1950g
Environmental Considerations:
Relative Humidity: • 10%-95%
OperatingTemperature:
• -10°C - +55°C
Supervised Zones:
Onboard:
Z1 – Z8 COM: • 8 Single or dual end-of-line (EOL2,2KΩ) tamper point support
Tamper: • Enclosure tamper input (does notreduce point capacity)
Programmable Outputs (PO):
Onboard:
PO -1: • supervised output max 500mA
PO -2: • supervised output max 500mA
Relay: • -12V output max 100mA
Number of...
Zones: • 32
Users: • 128
Key Fobs: • 128
Events: • 256 history events, stamped withtime and date
• 256 EN history events, stamped withtime and date
• 256 dialer history events, stampedwith time and date
Pin Code variations: • 1.000.000
Keypads: • 8
DX2010 • 3
DX3010: • 2
B426: • 2
B450: • 1
Wireless Receiver: • 1
Wireless Devices: • 32
Power:
Power Supply Type: • A
Transformer: • 230V Input/18VAC 20VAFuse=500mA
AC Input: • AC Input Voltage: 195 VAC to 253VAC
• Line Voltage Frequency: 50 Hz• Panel AC Input Voltage: 18-22V AC
DC Output: • maximum current for all components1100mA
• max current for all componentsBattery 7Ah standby 12h (rechargeBatt 80% in 72h) = 550mA
Aux (+12V/GND)Output:
• 500mA maximum
Option Bus : • 500mA maximum
Cable requirements: • four wire, AWG18 or AWG22• maximum length 200m (Panel to last
KP)• maximum BUS 1 length 700m ( max
14 devices, max 8 KPs)
Panel PCB: • Quiescent current maximum 100mA
Battery: • 12V/7 Ah, lead acid rechargeable
Ordering information
AMAX panel 3000 ENLanguage Package 2: French, German, Dutch,PortugueseOrder number ICP-AMAX3-P2-EN
AMAX panel 3000 ENLanguage Package 3: English, Spanish, Polish, SwedishOrder number ICP-AMAX3-P3-EN
Accessories
AE20ENAE20EN plastic enclosure for DX2010/DX3010.Order number AE20EN
AMAX keypad 2000 L8AMAX keypad 2000 L8, 8 zone LED keypad.Order number IUI-AMAX-LED8
AMAX keypad 2000 D8AMAX keypad 2000 D8, 8 zones LCD Icon keypad.Order number IUI-AMAX-LCD8
3 | AMAX panel 3000 EN
AMAX keypad 3000 L8AMAX keypad 3000 L8 is a 8 zone LED keypad.Approval: EN 50131-3 Grade 2Order number IUI-AMAX3-LED8
AMAX keypad 3000 L16AMAX keypad 3000 L16 is a 16 zone LED keypad.Approval: EN 50131-3 Grade 2Order number IUI-AMAX3-LED16
AMAX keypad 4000 TAMAX keypad 4000 T, LCD text keypad, two lines witheach 18 characters.Order number IUI-AMAX4-TEXT
DX2010 Input ExpanderZone expansion module with 8 DOEL zone inputs.Order number DX2010
DX3010 Octo‑output ExpanderPackage includes only the DX3010 board.Order number DX3010
B426 Ethernet Communication ModuleSupports two-way communications over Ethernetnetworks for compatible control panels.Order number B426
B442 Conettix Plug-in GPRS Cellular CommunicatorMulti-function cellular communicator that provides IPcommunication over a (GPRS) cellular network.Order number B442
B443 Conettix Plug-in HSPA+ Cellular CommunicatorMulti-function 3G/4G cellular communicator providingIP communication over a GPRS/EDGE/UMTS/HSPA+cellular network.Order number B443
B450 Conettix Plug-in Communicator InterfaceSupports two-way IP communication over commercialcellular networks using a plug-in CellularCommunicator for compatible control panels.Order number B450
4 | AMAX panel 3000 EN
Represented by:
Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]
Bosch Security Systems B.V.P.O. Box 800025617 BA Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]
Robert Bosch (SEA) Pte Ltd, SecuritySystems11 Bishan Street 21Singapore 573943Phone: +65 6571 2808Fax: +65 6571 [email protected]
Bosch (Shanghai) Security Systems Ltd.201 Building, No. 333 Fuquan RoadNorth IBPChangning District, Shanghai200335 ChinaPhone +86 21 22181111Fax: +86 21 22182398www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems DivisionVia Anhanguera, Km 98CEP 13065-900Campinas, Sao Paulo, BrazilPhone: +55 19 2103 2860Fax: +55 19 2103 [email protected]
© Bosch Security Systems 2014 | Data subject to change without notice13939978507 | en, V6, 09. Dec 2014