Amarex N - 60 Hz
Transcript of Amarex N - 60 Hz
Submersible Motor Pump
Amarex N
60 Hz
Type Series Booklet
Legal information/Copyright
Type Series Booklet Amarex N
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,edited or processed for any other purpose, nor otherwise transmitted, published or made available toa third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
© KSB Aktiengesellschaft, Frankenthal 28.11.2013
Contents
Waste Water ......................................................................................................................................................4
Submersible Motor Pump ............................................................................................................................................... 4
Amarex N ................................................................................................................................................................... 4
Main applications ................................................................................................................................................ 4
Fluids handled ...................................................................................................................................................... 4
Operating data ....................................................................................................................................................4
Designation .......................................................................................................................................................... 4
Design details ....................................................................................................................................................... 5
Materials ..............................................................................................................................................................5
Product benefits .................................................................................................................................................. 5
Certifications ........................................................................................................................................................ 6
Overview of product features / selection tables ................................................................................................ 6
Table of fluids handled .................................................................................................................................6
Overview of product features ....................................................................................................................... 8
Options of material variants .............................................................................................................................10
Technical data .................................................................................................................................................... 10
Characteristic curves ..........................................................................................................................................16
Amarex N S 50-170, n = 3500 rpm ............................................................................................................... 16
Amarex N S 50-220, n = 3500 rpm ............................................................................................................... 17
Amarex N F 50-170, n = 3500 rpm ............................................................................................................... 18
Amarex N F 50-220, n = 3500 rpm ............................................................................................................... 19
Amarex N F 65-170, n = 3500 rpm ............................................................................................................... 20
Amarex N F 65-220, n = 1750 rpm ............................................................................................................... 21
Amarex N F 80-220, n = 1750 rpm ............................................................................................................... 22
Amarex N F 100-220, n = 1750 rpm ............................................................................................................. 23
Dimensions and connections ............................................................................................................................24
Connections .................................................................................................................................................. 24
Dimensions ...................................................................................................................................................25
Installation types ...............................................................................................................................................37
Information on installation ............................................................................................................................... 38
Suggested installation layouts for transportable pump sets .................................................................... 38
Suggested installation layouts for stationary pump sets ..........................................................................39
Suggested electrical installation layouts ....................................................................................................41
Scope of supply .................................................................................................................................................. 41
Accessories ......................................................................................................................................................... 42
Installation parts for stationary pump sets ................................................................................................42
Installation parts for transportable pump sets ..........................................................................................43
Chain for stationary and transportable pump sets .................................................................................... 44
Pump accessories .......................................................................................................................................... 44
Electrical accessories ....................................................................................................................................46
Contents
3
Waste Water
Submersible Motor Pump
Amarex N
Main applications
▪ Waste water management
▪ Drainage systems
▪ Sewage treatment plants
▪ Sludge disposal
▪ Drainage of rooms and areas at risk of flooding onmunicipal, commercial and industrial premises
Fluids handled
▪ Service water
▪ Grey water
▪ Waste water with faeces
▪ Waste water containing long fibres and solid substances
▪ Fluids containing gas
▪ Activated sludge
▪ Digested sludge
▪ Raw sludge
Operating data
Operating properties
Characteristic ValueFlow rate Q Up to 135 m3/h (37.5 l/s)Head H Up to 47 mFluid temperature t Up to +40 °C1)
Motor rating P2 0.8 kW to 4.1 kWEnclosure IP 68 to EN 60529 / IEC 529
Designation
Example: Amarex N F 80-220 / 04 4 YL G-180
Key to the designation
Code DescriptionAmarex N Type seriesF Impeller type
F Free-flow impellerS Cutter
80-220 Size of hydraulic system04 Motor size4 Number of motor poles
2 2-pole4 4-pole
YL Motor versionUL Without explosion protection, for fluid
temperatures of up to 55 °CYL2) With explosion protection, for fluid
temperatures of up to 40 °CWL Without explosion protection, for fluid
temperatures of up to 60 °CG Material variant
G Pump casing: grey cast iron JL1040Intermediate casing: grey cast iron JL 1040Impeller: grey cast iron JL 1040
G1 Pump casing: grey cast iron JL1040Intermediate casing: grey cast iron JL 1040Impeller: Noridur 1.4593 (duplex stainlesssteel)
G2 Pump casing: grey cast iron JL1040Intermediate casing: grey cast iron JL 1040Impeller: Norihard 0.9635 (white cast iron)
GH Pump casing: grey cast iron JL1040Intermediate casing: Norihard 0.9635 (whitecast iron)Impeller: Norihard 0.9635 (white cast iron)
180 Nominal impeller diameter [mm]
1) For short periods (3 to 5 minutes or until the temperature guards trip) UL and WL models can be operated at up to 80 °C.2) In countries stipulating explosion-proof units for handling sewage with faeces, motor version YL must be used.
Waste WaterSubmersible Motor Pump
4 Amarex N
Design details
Design
▪ Fully floodable submersible motor pump
▪ Not self-priming
▪ Close-coupled pump set
Shaft seal
▪ Two bi-directional mechanical seals in tandemarrangement, with liquid reservoir
Impeller types
▪ Various, application-based impeller types
F impeller
Free-flowimpeller (impeller type F)
Suitable for the followingfluids:fluids containing solids andstringy material as well asfluids with entrapped air orgas
F impellers are suitable for handling the following fluids:
▪ Activated sludge
▪ Digested sludge
▪ Heating sludge
▪ Mixed water
▪ Raw waste water
▪ Raw sludge
▪ Recirculated sludge
S impeller
Impeller withcutter (impeller type S)
Suitable for the followingfluids:faeces, domestic sewage andwaste water containing longfibres
S impellers are suitable for handling the following fluids:
▪ Domestic waste water
▪ Grey water
▪ Waste water with faeces
Standard bearings
▪ Grease-lubricated bearings sealed for life
▪ Maintenance-free
Reinforced bearings (optional, only for S impeller)
The following hydraulic system/motor combinations can befitted with reinforced bearings:
Reinforced bearings
Size of hydraulic system Motor size and number ofpoles
Amarex N S 50-170(motor version YL)
002, 012, 022
Amarex N S 50-220(motor version YL)
032, 042
Pump-end bearings:
▪ Grease-lubricated bearing sealed for life
Drive
▪ Three-phase asynchronous squirrel-cage motor
Explosion-proof pump sets comply with Ex dc IIB type ofprotection.
Materials
Overview of available materials
Component MaterialCasing JL 1040Intermediate casing JL 1040Impeller JL 10403)
Cutter (only Amarex N S) 1.2080 (K100)Shaft 1.4021Mechanical seal (motor end) Carbon/Al2O3
Mechanical seal (pump end) SiC/SiCScrews/bolts A2Sealing elements NBR
Product benefits
▪ Easy and fast installation/removal with polarised,absolutely watertight cable and KSB plug connectionensuring correct installation
▪ Motor absolutely watertight, also in the event of damageto the cable sheath and core insulation, with individuallystripped, tinned and resin-sealed conductors
▪ Highest operating reliability with optimum motorselection for operating mode S1, thermal class F,explosion-proof variant in Ex d IIB T4 Gb
▪ Long service life with shaft made of corrosion-resistantstainless steel
▪ Zero maintenance, ideal for continuous duty, with long-life bearings sealed on both sides, grease-packed for life
▪ Environmentally friendly, non-toxic, food-approved oil fillfor lubricating the mechanical seal (liquid reservoir)
▪ Significant reduction of energy costs by optimisedhydraulic system and high efficiency
▪ Absolutely reliable and non-clogging design withoptimised cutter (S impeller).
▪ Close-coupled pump design prevents risk of leakage(pump volute casing and motor housing cast as a singlepiece)
▪ Stationary pump sets easy to install and remove withautomatic, bolt-free connection; leakage prevented byelastic sealing elements
▪ Ease of service with wetted bolts made of stainless steel,which are easy to undo even after years of operation
▪ Two bi-directional mechanical seals with oil reservoir filledwith ecologically acceptable oil provide double safety
▪ Well suited for mechanical seal with covered spring forabrasive and aggressive fluids
▪ Only one set of spare parts for all pump sizes thanks tomodular system
3) Amarex N F 50/65/80/100 in material variant G1 = 1.4593 (Noridur), G2 = 0.9635 (Norihard)
Waste WaterSubmersible Motor Pump
Amarex N 5
Certifications
Label Valid in: CommentEurope Suitable for plants to Standard
EN 12050-1Europe BMW (test report) Nos.:
0420266-01 to 05
Overview of product features / selection tables
Table of fluids handled
The table below for your guidance is based on KSB's long-standing experience. The data are standard values and are notto be considered as generally binding recommendations. Moredetailed advice is available from our specialist department.Make use of our laboratory's expertise when selectingmaterials.
Selection aid for materials and hydraulic systems per fluid
Fluid handled4) Recommended
material
Recommended
impellertype5)
Comments, further recommendations
Grey water JL 1040 F, S Free passage > any solids contained, possibly pre-screenedRiver water JL 1040 F Free passage > any solids contained, possibly pre-screenedContaminated surface water JL 1040 F Free passage > any solids contained, possibly pre-screenedWaste water
▪ Untreated municipal wastewater
JL 1040 S ATV6) recommends a free passage of 100 mm; min. free passage:76 mm
▪ Waste water containing airor gas
JL 1040 F Up to 8 %, contact KSB for handling fluids with high outgassing rates
▪ Raw waste water JL 1040 F ATV6) recommends a free passage of 100 mm; min. free passage:76 mm
▪ Mixed water JL 1040 F Free passage > any solids contained, possibly pre-screened▪ Waste water or grey water
containing long fibresJL 1040 F, S Free passage > any solids contained, possibly pre-screened
▪ Highly abrasive waste watercausing wear (chemicallyneutral)
Norihard F For solids contents < 5 g/lmaterial variants G2, GH
▪ Corrosive waste water Noridur F Material variant G1 if required according to analysis of the fluidhandled
Sludge▪ Raw sludge JL 1040 F Pumpable up to a dry substance content of: 8 % (F)▪ Digested sludge JL 1040 F Pumpable up to a dry substance content of: 8 % (F)▪ Activated sludge JL 1040 F Pumpable up to a dry substance content of: 8 % (F)
Industrial waste water containing ...▪ Paint suspensions JL 1040 F Solvent-free, observe the operator's instructions.▪ Lacquer/paint/varnish
suspensionsJL 1040 F Solvent-free, contact KSB for silicone-free version.
▪ Fibres/pulp JL 1040 F, S ▪ Chips/swarf Norihard F Material variant G2 or GH, special mechanical seal; solids content <
5 g/l▪ Abrasive substances7) Norihard F Material variant G2 or GH, special mechanical seal; solids content <
5 g/lMildly acidic industrial wastewater
JL 1040 F pH value ≥ 6.5 G1 variant and FPM (Viton) O-rings
Non-corrosive waste water▪ Ammonium hydroxide JL 1040 F ▪ Ammonium hydroxide 5 %
NH4OHJL 1040 F
▪ Urea 25 % (NH2)2-CO JL 1040 F ▪ Potassium hydroxide 10 %
KOHJL 1040 F
▪ Calcium hydroxide 5 %Ca(OH)2
JL 1040 F
▪ Sodium hydroxide 5 % NaOH JL 1040 F
4) For any fluids which are not listed in this table contact KSB.5) The first impeller type listed should be given preference.6) ATV = German regulatory body for waste water management7) Severe hydroabrasive wear occurs if solids contents of approx. 0.5 g/l or higher are combined with circumferential speeds
exceeding 20 m/s or low-flow conditions to the left of the duty point.
Waste WaterSubmersible Motor Pump
6 Amarex N
Fluid handled4) Recommended
material
Recommended
impellertype5)
Comments, further recommendations
▪ Sodium carbonate 30 %Na2CO3
JL 1040 F
Non-corrosive waste water containing ...▪ Aliphatic hydrocarbons, e.g.
oils, petrol, butane, methaneJL 1040 F FPM (Viton) O-rings, TEHSITE cable, for high concentrations contact
KSB.▪ Aromatic hydrocarbons, e.g.
benzene, styreneJL 1040 F FPM (Viton) O-rings, TEHSITE cable, for high concentrations contact
KSB.▪ Chlorinated hydrocarbons
(e.g. tetrachloroethylene,ethylene chloride,chloroform, methylenechloride)
JL 1040 F FPM (Viton) O-rings, TEHSITE cable, for high concentrations contactKSB.
Highly abrasive industrial waste water causing wear (chemically neutral)8)
▪ Lime water Norihard F For sinter contents < 5 g/l, material variant GH▪ Lime milk containing quartz
and pigment suspensionNorihard F Lime milk of up to 15 %, material variant GH
▪ Water/sand mixture Norihard F Up to 5 g/l solids content, material variant GH
4) For any fluids which are not listed in this table contact KSB.5) The first impeller type listed should be given preference.8) The material variants required highly depend on the operating hours, rotational speed and flow velocity.
Waste WaterSubmersible Motor Pump
Amarex N 7
Overview of product features
Standard designs
Size S impeller F impeller
Amarex N S 50-... Amarex N F 50-...Amarex N F 65-...Amarex N F 80-...Amarex N F 100-...
Material variant G GNumber of motor poles2-pole 50-170/...
50-220/...50-170/...50-220/...65-170/...
4-pole - 65-220/...80-220/...100-200/...
Explosion protectionMotor version UL Not explosion-proofMotor version YL9) Ex d IIB T4 GbMotor version WL Not explosion-proofMotorStarting method DOL10)
Voltage 380 VCooling Cooled by surrounding fluidMode of operation S1: submerged (max. 25 m) (see 2) in outline drawing)
S3: outside the fluid (see 1) in outline drawing)Power cableType Rubber-sheathed cable (H07RN8-F 7G1.5²)Length 10 mCable entry Absolutely watertightSealing elementsShaft seal Mechanical sealElastomer seals NBRMonitoring equipmentWinding temperature version YL Temperature monitoring circuit (with automatic reset and start-up): bimetal switch
directly connected with the control circuit of the motor contactorLimiting circuit (temperature limit for explosion protection without automatic reset):
bimetal switch connected via a tripping unit with manual resetWinding temperature version UL, WL Temperature monitoring circuit (with automatic reset and start-up): bimetal switch
directly connected with the control circuit of the motorCoating Environmentally friendly KSB top coat (two-component epoxy paint), colour RAL 5002,
film thickness = 80 µmInstallation (⇨ Page 37)Stationary, with guide hoop Installation depths 1.5 m/1.8 m/2.1 mStationary, with single guide rail Installation depth 4.5 mStationary, with twin guide rail Installation depth 4.5 mStationary, with guide wire Installation depth 4.5 mTransportable Installation depth 4.5 mMaximum temperature of fluid handledMotor version UL 55 °CMotor version YL 40 °CMotor version WL 60 °C
9) In countries stipulating explosion-proof units for handling sewage with faeces, motor version YL must be used.10) Maximum switching frequency: 30 starts per hour
Waste WaterSubmersible Motor Pump
8 Amarex N
Standard variants
Size S impeller F impeller
Amarex N S50-170/...
Amarex N S50-220/...
Amarex N F 50-...Amarex N F 65-...Amarex N F 80-...Amarex N F 100-...
Material variant G G1 G2 GHNumber of motor poles2-pole - 50-170/...
50-220/...65-170/...
4-pole - 65-220/...80-220/...100-200/...
Shaft materialMaterial 1.4462 + C45 N ✘ ✘MotorVoltage , version U: 230 V, 440 V, 460 V, 690 VVoltage, version Y, W: 440 V, 690 VMonitoringLeakage sensor in the motor space11) ✘ ✘Suction flangeDrilled to DIN/ISO PN16 or ASME 150 lb - ✘Sealing elementsElastomer seals: O-rings and flange gaskets made ofViton, lower mechanical seal with Viton gaskets
✘ ✘
Shaft seal: special mechanical seal (mechanical seal withcovered spring HJ977)12)
✘ ✘
Power cablesStandard rubber-sheathed cable (H07RN8-F 7G1.52); forversions ULG, YLG, WLG13)
✘ ✘
Standard rubber-sheathed cable (H07RN8-F 8x1.52) forpump with leakage sensor13)
✘ ✘
TEHSITE power cable (8G1.5) for pump with or withoutleakage sensor, for versions ULG, YLG, WLG14)
✘ ✘
Shielded rubber-sheathed cable (S07RC4N8-F-8G1.5) forpump with or without leakage sensor, for versions ULG,YLG, WLG controlled by a frequency inverter15)16)
✘ ✘
Coating Environmentally friendly KSB standard coating (two-component epoxypaint), colour RAL 5002, film thickness = 300 µm
Installation (⇨ Page 37)Stationary, with guide hoop Installation depths 1.5 m/1.8 m/2.1 mStationary, with single guide rail Installation depth 6.0 mStationary, with twin guide rail Installation depth 6.0 mStationary, with guide wire Installation depth 9.5 mTransportable Installation depth 4.5 m
11) 8-core connection cable required12) Silicon carbide/silicon carbide seal faces, Viton sealing elements, stainless steel spring and metal part, Viton (FPM) O-rings
and flange gaskets13) Total lengths available 15 m/20 m/30 m/40 m/50 m14) Total lengths available 10 m/15 m/20 m15) Total lengths available 10 m/15 m/20 m/30 m16) The percentage of submersible motor pumps controlled by frequency inverters is on the increase. If pump speed is
controlled by a frequency inverter, high frequency interference signals occur in the area of the motor connection cables.The cables between motor and frequency inverter can act like a transmitting antenna. In accordance with the EuropeanDirective 89/336/EEC these electromagnetic interferences have to be limited. The frequency inverter must therefore beequipped with a suitable output filter and/or the electric cables between frequency inverter and motor have to beshielded. Therefore the use of shielded cables is often demanded for submersible motor pumps controlled by frequencyinverters.
Waste WaterSubmersible Motor Pump
Amarex N 9
Options of material variants
Overview of material variants for standard designs
Component S impeller F impeller
Amarex N S 50-170/...Amarex N S 50-220/...
Amarex N F 50-...Amarex N F 65-...Amarex N F 80-...Amarex N F 100-...
G GCasing JL 1040 JL 1040Intermediate casing JL 1040 JL 1040Impeller JL 1040 JL 1040Cutter 1.2080.02 (K100) -Shaft 1.4021 1.4021Mechanical seal Drive end Carbon/Al2O3 Carbon/Al2O3
Pump end SiC/SiC SiC/SiCScrews/bolts A2 A2Elastomer seals NBR NBR
Overview of material variants for standard designs
Component S impeller F impeller
Amarex N S50-170/...
Amarex N S50-220/...
Amarex N F 50-...Amarex N F 65-...Amarex N F 80-...Amarex N F 100-...
G G1 G2 GHCasing - JL 1040 JL 1040 JL 1040Intermediate casing - JL 1040 JL 1040 0.963518)
Impeller - 1.459317) 0.963518) 0.963518)
Cutter - - - -Shaft - 1.4021 1.4021 1.4021Mechanical seal Drive end - Carbon/Al2O3 Carbon/Al2O3 Carbon/Al2O3
Pump end - SiC/SiC SiC/SiC SiC/SiCScrews/bolts - A2 A2 A2Elastomer seals - NBR19) NBR19) NBR19)
Technical data
3~ 690 V
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]100 S 50-170 / 012 LG ULG 2,49 1,9 2,3 14,75 55 39 100 S 50-170 / 012 LG YLG 2,49 1,9 2,3 14,75 40 39 100 S 50-170 / 012 LG WLG 2,49 1,9 2,3 14,75 60 39 110 S 50-170 / 012 LG ULG 2,49 1,9 2,3 14,75 55 39 110 S 50-170 / 012 LG YLG 2,49 1,9 2,3 14,75 40 39 110 S 50-170 / 012 LG WLG 2,49 1,9 2,3 14,75 60 39 120 S 50-170 / 022 LG ULG 3,0 2,3 2,9 14,75 55 39 120 S 50-170 / 022 LG YLG 3,0 2,3 2,9 14,75 40 39 120 S 50-170 / 022 LG WLG 3,0 2,3 2,9 14,75 60 39 130 S 50-170 / 022 LG ULG 3,0 2,3 2,9 14,75 55 39 130 S 50-170 / 022 LG YLG 3,0 2,3 2,9 14,75 40 39 130 S 50-170 / 022 LG WLG 3,0 2,3 2,9 14,75 60 39 130 S 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 54 130 S 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 54 130 S 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 54 140 S 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 54 140 S 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 54
17) Noridur (= duplex stainless steel)18) Norihard (= white cast iron)19) Optional: FPM
Waste WaterSubmersible Motor Pump
10 Amarex N
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]140 S 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 54 150 S 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 54 150 S 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 54 150 S 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 54 158 S 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 54 158 S 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 54 158 S 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 54 90 F 50-170 / 002 LG ULG 1,73 1,3 1,7 14,75 55 41 3910023790 F 50-170 / 002 LG YLG 1,73 1,3 1,7 14,75 40 41 3910023890 F 50-170 / 002 LG WLG 1,73 1,3 1,7 14,75 60 41 107 F 50-170 / 022 LG ULG 3,03 2,3 2,9 14,75 55 41 39100239107 F 50-170 / 022 LG YLG 3,03 2,3 2,9 14,75 40 41 39100240107 F 50-170 / 022 LG WLG 3,03 2,3 2,9 14,75 60 41 110 F 50-220 / 032 LG ULG 3,68 2,8 3,24 32 55 51 110 F 50-220 / 032 LG YLG 3,68 2,8 3,24 32 40 51 110 F 50-220 / 032 LG WLG 3,68 2,8 3,24 32 60 51 120 F 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 51 120 F 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 51 120 F 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 51 130 F 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 52 130 F 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 52 130 F 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 52 140 F 50-220 / 042 LG ULG 5,25 4,1 4,65 32 55 52 140 F 50-220 / 042 LG YLG 5,25 4,1 4,65 32 40 52 140 F 50-220 / 042 LG WLG 5,25 4,1 4,65 32 60 52 112 F 65-170 / 032 LG ULG 3,68 2,8 3,24 32 55 57 112 F 65-170 / 032 LG YLG 3,68 2,8 3,24 32 40 57 112 F 65-170 / 032 LG WLG 3,68 2,8 3,24 32 60 57 120 F 65-170 / 042 LG ULG 5,25 4,1 4,65 32 55 58 120 F 65-170 / 042 LG YLG 5,25 4,1 4,65 32 40 58 120 F 65-170 / 042 LG WLG 5,25 4,1 4,65 32 60 58 128 F 65-170 / 042 LG ULG 5,25 4,1 4,65 32 55 58 128 F 65-170 / 042 LG YLG 5,25 4,1 4,65 32 40 58 128 F 65-170 / 042 LG WLG 5,25 4,1 4,65 32 60 58 136 F 65-170 / 042 LG ULG 5,25 4,1 4,65 32 55 59 136 F 65-170 / 042 LG YLG 5,25 4,1 4,65 32 40 59 136 F 65-170 / 042 LG WLG 5,25 4,1 4,65 32 60 59 135 F 65-220 / 004 LG ULG 1,2 0,8 1,12 10,5 55 49 135 F 65-220 / 004 LG YLG 1,2 0,8 1,12 10,5 40 49 135 F 65-220 / 004 LG WLG 1,2 0,8 1,12 10,5 60 49 145 F 65-220 / 014 LG ULG 1,8 1,3 1,7 10,5 55 49 145 F 65-220 / 014 LG YLG 1,8 1,3 1,7 10,5 40 49 145 F 65-220 / 014 LG WLG 1,8 1,3 1,7 10,5 60 49 155 F 65-220 / 014 LG ULG 1,8 1,3 1,7 10,5 55 49 155 F 65-220 / 014 LG YLG 1,8 1,3 1,7 10,5 40 49 155 F 65-220 / 014 LG WLG 1,8 1,3 1,7 10,5 60 49 165 F 65-220 / 024 LG ULG 2,45 1,8 2,34 10,5 55 50 165 F 65-220 / 024 LG YLG 2,45 1,8 2,34 10,5 40 50 165 F 65-220 / 024 LG WLG 2,45 1,8 2,34 10,5 60 50 175 F 65-220 / 024 LG ULG 2,45 1,8 2,34 10,5 55 50 175 F 65-220 / 024 LG YLG 2,45 1,8 2,34 10,5 40 50 175 F 65-220 / 024 LG WLG 2,45 1,8 2,34 10,5 60 50 120 F 80-220 / 034 LG ULG 2,82 2,2 2,7 23,2 55 62 120 F 80-220 / 034 LG YLG 2,82 2,2 2,7 23,2 40 62 120 F 80-220 / 034 LG WLG 2,82 2,2 2,7 23,2 60 62 135 F 80-220 / 034 LG ULG 2,82 2,2 2,7 23,2 55 63 135 F 80-220 / 034 LG YLG 2,82 2,2 2,7 23,2 40 63 135 F 80-220 / 034 LG WLG 2,82 2,2 2,7 23,2 60 63 150 F 80-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 63 150 F 80-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 63 150 F 80-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 63 165 F 80-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 64 165 F 80-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 64
Waste WaterSubmersible Motor Pump
Amarex N 11
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]165 F 80-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 64 180 F 80-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 64 180 F 80-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 64 180 F 80-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 64 120 F 100-220 / 034 LG ULG 2,82 2,2 2,7 23,2 55 63 120 F 100-220 / 034 LG YLG 2,82 2,2 2,7 23,2 40 63 120 F 100-220 / 034 LG WLG 2,82 2,2 2,7 23,2 60 63 135 F 100-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 64 135 F 100-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 64 135 F 100-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 64 150 F 100-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 64 150 F 100-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 64 150 F 100-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 64 165 F 100-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 65 165 F 100-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 65 165 F 100-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 65 180 F 100-220 / 044 LG ULG 4,7 3,7 4,46 23,2 55 66 180 F 100-220 / 044 LG YLG 4,7 3,7 4,46 23,2 40 66 180 F 100-220 / 044 LG WLG 4,7 3,7 4,46 23,2 60 66
3~ 460 V
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]100 S 50-170 / 012 LG ULG 2,49 1,9 4,0 33 55 39 110 S 50-170 / 012 LG ULG 2,49 1,9 4,0 33 55 39 120 S 50-170 / 022 LG ULG 3,0 2,3 4,6 33 55 39 130 S 50-170 / 022 LG ULG 3,0 2,3 4,6 33 55 39 130 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 140 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 150 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 158 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 90 F 50-170 / 002 LG ULG 1,77 1,3 3,1 33 55 41 107 F 50-170 / 022 LG ULG 3,0 2,3 4,6 33 55 41 110 F 50-220 / 032 LG ULG 3,68 2,8 5,9 94 55 51 120 F 50-220 / 042 LG ULG 5,25 4,1 7,9 94 55 51 130 F 50-220 / 042 LG ULG 5,25 4,1 7,9 94 55 52 140 F 50-220 / 042 LG ULG 5,25 4,1 7,9 94 55 52 112 F 65-170 / 032 LG ULG 3,68 2,8 5,9 94 55 57 120 F 65-170 / 042 LG ULG 5,25 4,1 7,9 94 55 58 128 F 65-170 / 042 LG ULG 5,25 4,1 7,9 94 55 58 136 F 65-170 / 042 LG ULG 5,25 4,1 7,9 94 55 59 135 F 65-220 / 004 LG ULG 1,2 0,8 2,3 21 55 49 145 F 65-220 / 014 LG ULG 1,8 1,3 2,95 21 55 49 155 F 65-220 / 014 LG ULG 1,8 1,3 2,95 21 55 49 165 F 65-220 / 024 LG ULG 2,45 1,8 3,8 21 55 50 175 F 65-220 / 024 LG ULG 2,45 1,8 3,8 21 55 50 120 F 80-220 / 034 LG ULG 2,82 2,2 5,0 49 55 62 135 F 80-220 / 034 LG ULG 2,82 2,2 5,0 49 55 63 150 F 80-220 / 044 LG ULG 4,7 3,7 7,2 49 55 63 165 F 80-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 180 F 80-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 120 F 100-220 / 034 LG ULG 2,82 2,2 5,0 49 55 63 135 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 150 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 165 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 65 180 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 66
Waste WaterSubmersible Motor Pump
12 Amarex N
3~ 440 V
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]100 S 50-170 / 012 LG ULG 2,49 1,9 4,0 33 55 39 100 S 50-170 / 012 LG YLG 2,49 1,9 4,0 33 40 39 100 S 50-170 / 012 LG WLG 2,49 1,9 4,0 33 60 39 110 S 50-170 / 012 LG ULG 2,49 1,9 4,0 33 55 39 110 S 50-170 / 012 LG YLG 2,49 1,9 4,0 33 40 39 110 S 50-170 / 012 LG WLG 2,49 1,9 4,0 33 60 39 120 S 50-170 / 022 LG ULG 3,0 2,3 4,6 33 55 39 120 S 50-170 / 022 LG YLG 3,0 2,3 4,6 33 40 39 120 S 50-170 / 022 LG WLG 3,0 2,3 4,6 33 60 39 130 S 50-170 / 022 LG ULG 3,0 2,3 4,6 33 55 39 130 S 50-170 / 022 LG YLG 3,0 2,3 4,6 33 40 39 130 S 50-170 / 022 LG WLG 3,0 2,3 4,6 33 60 39 130 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 130 S 50-220 / 042 LG YLG 5,25 4,1 7,9 93 40 54 130 S 50-220 / 042 LG WLG 5,25 4,1 7,9 93 60 54 140 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 140 S 50-220 / 042 LG YLG 5,25 4,1 7,9 93 40 54 140 S 50-220 / 042 LG WLG 5,25 4,1 7,9 93 60 54 150 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 150 S 50-220 / 042 LG YLG 5,25 4,1 7,9 93 40 54 150 S 50-220 / 042 LG WLG 5,25 4,1 7,9 93 60 54 158 S 50-220 / 042 LG ULG 5,25 4,1 7,9 93 55 54 158 S 50-220 / 042 LG YLG 5,25 4,1 7,9 93 40 54 158 S 50-220 / 042 LG WLG 5,25 4,1 7,9 93 60 54 90 F 50-170 / 002 LG ULG 1,77 1,3 3,1 33 55 41 90 F 50-170 / 002 LG YLG 1,77 1,3 3,1 33 40 41 90 F 50-170 / 002 LG WLG 1,77 1,3 3,1 33 60 41 107 F 50-170 / 022 LG ULG 3,0 2,3 4,6 33 55 41 107 F 50-170 / 022 LG YLG 3,0 2,3 4,6 33 40 41 107 F 50-170 / 022 LG WLG 3,0 2,3 4,6 33 60 41 110 F 50-220 / 032 LG ULG 3,68 2,8 5,9 94 55 51 110 F 50-220 / 032 LG YLG 3,68 2,8 5,9 94 40 51 110 F 50-220 / 032 LG WLG 3,68 2,8 5,9 94 60 51 120 F 50-220 / 042 LG ULG 5,25 4,1 7,9 94 55 51 120 F 50-220 / 042 LG YLG 5,25 4,1 7,9 94 40 51 120 F 50-220 / 042 LG WLG 5,25 4,1 7,9 94 60 51 130 F 50-220 / 042 LG ULG 5,25 4,1 7,9 94 55 52 130 F 50-220 / 042 LG YLG 5,25 4,1 7,9 94 40 52 130 F 50-220 / 042 LG WLG 5,25 4,1 7,9 94 60 52 140 F 50-220 / 042 LG ULG 5,25 4,1 7,9 94 55 52 140 F 50-220 / 042 LG YLG 5,25 4,1 7,9 94 40 52 140 F 50-220 / 042 LG WLG 5,25 4,1 7,9 94 60 52 112 F 65-170 / 032 LG ULG 3,68 2,8 5,9 94 55 57 112 F 65-170 / 032 LG YLG 3,68 2,8 5,9 94 40 57 112 F 65-170 / 032 LG WLG 3,68 2,8 5,9 94 60 57 120 F 65-170 / 042 LG ULG 5,25 4,1 7,9 94 55 58 120 F 65-170 / 042 LG YLG 5,25 4,1 7,9 94 40 58 120 F 65-170 / 042 LG WLG 5,25 4,1 7,9 94 60 58 128 F 65-170 / 042 LG ULG 5,25 4,1 7,9 94 55 58 128 F 65-170 / 042 LG YLG 5,25 4,1 7,9 94 40 58 128 F 65-170 / 042 LG WLG 5,25 4,1 7,9 94 60 58 136 F 65-170 / 042 LG ULG 5,25 4,1 7,9 94 55 59 136 F 65-170 / 042 LG YLG 5,25 4,1 7,9 94 40 59 136 F 65-170 / 042 LG WLG 5,25 4,1 7,9 94 60 59 135 F 65-220 / 004 LG ULG 1,2 0,8 2,3 21 55 49 135 F 65-220 / 004 LG YLG 1,2 0,8 2,3 21 40 49 135 F 65-220 / 004 LG WLG 1,2 0,8 2,3 21 60 49 145 F 65-220 / 014 LG ULG 1,8 1,3 2,95 21 55 49 145 F 65-220 / 014 LG YLG 1,8 1,3 2,95 21 40 49 145 F 65-220 / 014 LG WLG 1,8 1,3 2,95 21 60 49 155 F 65-220 / 014 LG ULG 1,8 1,3 2,95 21 55 49 155 F 65-220 / 014 LG YLG 1,8 1,3 2,95 21 40 49
Waste WaterSubmersible Motor Pump
Amarex N 13
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]155 F 65-220 / 014 LG WLG 1,8 1,3 2,95 21 60 49 165 F 65-220 / 024 LG ULG 2,45 1,8 3,8 21 55 50 165 F 65-220 / 024 LG YLG 2,45 1,8 3,8 21 40 50 165 F 65-220 / 024 LG WLG 2,45 1,8 3,8 21 60 50 175 F 65-220 / 024 LG ULG 2,45 1,8 3,8 21 55 50 175 F 65-220 / 024 LG YLG 2,45 1,8 3,8 21 40 50 175 F 65-220 / 024 LG WLG 2,45 1,8 3,8 21 60 50 120 F 80-220 / 034 LG ULG 2,82 2,2 5,0 49 55 62 120 F 80-220 / 034 LG YLG 2,82 2,2 5,0 49 40 62 120 F 80-220 / 034 LG WLG 2,82 2,2 5,0 49 60 62 135 F 80-220 / 034 LG ULG 2,82 2,2 5,0 49 55 63 135 F 80-220 / 034 LG YLG 2,82 2,2 5,0 49 40 63 135 F 80-220 / 034 LG WLG 2,82 2,2 5,0 49 60 63 150 F 80-220 / 044 LG ULG 4,7 3,7 7,2 49 55 63 150 F 80-220 / 044 LG YLG 4,7 3,7 7,2 49 40 63 150 F 80-220 / 044 LG WLG 4,7 3,7 7,2 49 60 63 165 F 80-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 165 F 80-220 / 044 LG YLG 4,7 3,7 7,2 49 40 64 165 F 80-220 / 044 LG WLG 4,7 3,7 7,2 49 60 64 180 F 80-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 180 F 80-220 / 044 LG YLG 4,7 3,7 7,2 49 40 64 180 F 80-220 / 044 LG WLG 4,7 3,7 7,2 49 60 64 120 F 100-220 / 034 LG ULG 2,82 2,2 5,0 49 55 63 120 F 100-220 / 034 LG YLG 2,82 2,2 5,0 49 40 63 120 F 100-220 / 034 LG WLG 2,82 2,2 5,0 49 60 63 135 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 135 F 100-220 / 044 LG YLG 4,7 3,7 7,2 49 40 64 135 F 100-220 / 044 LG WLG 4,7 3,7 7,2 49 60 64 150 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 64 150 F 100-220 / 044 LG YLG 4,7 3,7 7,2 49 40 64 150 F 100-220 / 044 LG WLG 4,7 3,7 7,2 49 60 64 165 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 65 165 F 100-220 / 044 LG YLG 4,7 3,7 7,2 49 40 65 165 F 100-220 / 044 LG WLG 4,7 3,7 7,2 49 60 65 180 F 100-220 / 044 LG ULG 4,7 3,7 7,2 49 55 66 180 F 100-220 / 044 LG YLG 4,7 3,7 7,2 49 40 66 180 F 100-220 / 044 LG WLG 4,7 3,7 7,2 49 60 66
3~ 380 V
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]100 S 50-170 / 012 LG ULG 2,46 1,9 4,2 27 55 45 39100201110 S 50-170 / 012 LG ULG 2,46 1,9 4,2 27 55 45 39100203120 S 50-170 / 022 LG ULG 3,03 2,3 5,3 27 55 46 39100205130 S 50-170 / 022 LG ULG 3,03 2,3 5,3 27 55 46 39100207130 S 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 55 39100219140 S 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 55 39100221150 S 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 56 39100223158 S 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 56 3910022590 F 50-170 / 002 LG ULG 1,73 1,3 1,7 14,75 55 41 39100237107 F 50-170 / 022 LG ULG 3,03 2,3 2,9 14,75 55 41 39100239110 F 50-220 / 032 LG ULG 3,46 2,8 5,9 58 55 51 39100251120 F 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 51 39100253130 F 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 52 39100255140 F 50-220 / 042 LG ULG 5,08 4,1 8,45 58 55 52 39100257112 F 65-170 / 032 LG ULG 3,46 2,8 5,9 58 55 57 39100269120 F 65-170 / 042 LG ULG 5,08 4,1 8,45 58 55 58 39100271128 F 65-170 / 042 LG ULG 5,08 4,1 8,45 58 55 58 39100273136 F 65-170 / 042 LG ULG 5,08 4,1 8,45 58 55 59 39100275135 F 65-220 / 004 LG ULG 1,08 0,8 2,05 19 55 49 39100287145 F 65-220 / 014 LG ULG 1,77 1,3 3,1 19 55 49 39100289155 F 65-220 / 014 LG ULG 1,77 1,3 3,1 19 55 49 39100291
Waste WaterSubmersible Motor Pump
14 Amarex N
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[kW] [kW] [A] [A] [°C]165 F 65-220 / 024 LG ULG 2,51 1,8 4,25 19 55 50 39100293175 F 65-220 / 024 LG ULG 2,51 1,8 4,25 19 55 50 39100295120 F 80-220 / 034 LG ULG 2,75 2,2 4,9 42 55 62 39100307135 F 80-220 / 034 LG ULG 2,75 2,2 4,9 42 55 63 39100309150 F 80-220 / 044 LG ULG 4,82 3,7 8,1 42 55 63 39100311165 F 80-220 / 044 LG ULG 4,82 3,7 8,1 42 55 64 39100313180 F 80-220 / 044 LG ULG 4,82 3,7 8,1 42 55 64 39100315120 F 100-220 / 034 LG ULG 2,75 2,2 4,9 42 55 63 39100327135 F 100-220 / 044 LG ULG 4,82 3,7 8,1 42 55 64 39100329150 F 100-220 / 044 LG ULG 4,82 3,7 8,1 42 55 64 39100331165 F 100-220 / 044 LG ULG 4,82 3,7 8,1 42 55 65 39100333180 F 100-220 / 044 LG ULG 4,82 3,7 8,1 42 55 66 39100335
3~ 230 V
Impellerdiameter
Size Motor version P1 P2 IN IA Fluid temperature [kg] Mat. No.
[hp] [hp] [A] [A] [°C]100 S 50-170 / 012 LG ULG 2,46 1,9 6,9 45 55 39 110 S 50-170 / 012 LG ULG 2,46 1,9 6,9 45 55 39 120 S 50-170 / 022 LG ULG 3,03 2,3 8,8 45 55 39 130 S 50-170 / 022 LG ULG 3,03 2,3 8,8 45 55 39 130 S 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 54 140 S 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 54 150 S 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 54 158 S 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 54 90 F 50-170 / 002 LG ULG 1,73 1,3 5,1 45 55 41 107 F 50-170 / 022 LG ULG 3,03 2,3 8,8 45 55 41 110 F 50-220 / 032 LG ULG 3,46 2,8 9,75 96 55 51 120 F 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 51 130 F 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 52 140 F 50-220 / 042 LG ULG 5,08 4,1 14,0 96 55 52 112 F 65-170 / 032 LG ULG 3,46 2,8 9,75 96 55 57 120 F 65-170 / 042 LG ULG 5,08 4,1 14,0 96 55 58 128 F 65-170 / 042 LG ULG 5,08 4,1 14,0 96 55 58 136 F 65-170 / 042 LG ULG 5,08 4,1 14,0 96 55 59 135 F 65-220 / 004 LG ULG 1,08 0,8 3,4 31 55 49 145 F 65-220 / 014 LG ULG 1,77 1,3 5,1 31 55 49 155 F 65-220 / 014 LG ULG 1,77 1,3 5,1 31 55 49 165 F 65-220 / 024 LG ULG 2,51 1,8 7,0 31 55 50 175 F 65-220 / 024 LG ULG 2,51 1,8 7,0 31 55 50 120 F 80-220 / 034 LG ULG 2,75 2,2 8,1 69 55 62 135 F 80-220 / 034 LG ULG 2,75 2,2 8,1 69 55 63 150 F 80-220 / 044 LG ULG 4,82 3,7 13,4 69 55 63 165 F 80-220 / 044 LG ULG 4,82 3,7 13,4 69 55 63 180 F 80-220 / 044 LG ULG 4,82 3,7 13,4 69 55 64 120 F 100-220 / 034 LG ULG 2,75 2,2 8,1 69 55 63 135 F 100-220 / 044 LG ULG 4,82 3,7 13,4 69 55 64 150 F 100-220 / 044 LG ULG 4,82 3,7 13,4 69 55 64 165 F 100-220 / 044 LG ULG 4,82 3,7 13,4 69 55 65 180 F 100-220 / 044 LG ULG 4,82 3,7 13,4 69 55 66
Waste WaterSubmersible Motor Pump
Amarex N 15
Characteristic curves
Amarex N S 50-170, n = 3500 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6050170SE/0
0 5 10 15 20 25 30Q [m³/h]
0 50 100Q [US.gpm]
0 20 40 60 80 100Q [IM.gpm]
5
10
15
20
25
H [m]
20
40
60
80
H [ft]
0 2 4 6 8Q [l/s]
1.0
1.5
2.0
2.5
3.0
P [kW]
2
3
4
P [hp]
0 5 10 15 20 25 30Q [m³/h]
ø130
ø130
ø120
ø120
ø110
ø110
ø100
ø100
Qmax42.3
41
41
39.5
39.5
38
38
34
34
28
2010
42.7
41
41
39.5
39.5
38
38
34
34
2820
10
38.0
34
34
28
20
10
31.6
28
28
20
10
η [%]
Free passage = 10 mm
Waste WaterSubmersible Motor Pump
16 Amarex N
Amarex N S 50-220, n = 3500 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6050220SE/0
0 5 10 15 20 25 30Q [m³/h]
0 50 100Q [US.gpm]
0 20 40 60 80 100Q [IM.gpm]
15
20
25
30
35
40
45
H [m]
40
60
80
100
120
140
H [ft]
0 2 4 6 8Q [l/s]
2
3
4
P [kW]
2
4
6
P [hp]
0 5 10 15 20 25 30Q [m³/h]
ø158
ø158
ø150
ø150
ø140
ø140
ø130
ø130
Qmax
42.7
42
38
30
20
46.6
46
46
4442
38
30
20
44.7
44
44
42
42
38
30
20
41.7
38
38
30
20
η [%]
Free passage = 10 mm
Waste WaterSubmersible Motor Pump
Amarex N 17
Amarex N F 50-170, n = 3500 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6050170FE/0
0 5 10 15 20 25 30 35Q [m³/h]
0 50 100 150Q [US.gpm]
0 50 100Q [IM.gpm]
4
6
8
10
12
14
16
18
H [m]
20
40
60
H [ft]
0 2 4 6 8 10Q [l/s]
1.0
1.5
2.0
P [kW]
1
2
P [hp]
0 5 10 15 20 25 30 35Q [m³/h]
ø107
ø107
ø90
ø90
38.2
37
37
35
35
32
32
28
20
10
35.335
35
32
32
28
28
20
10
η [%]
Free passage = 40 mm
Waste WaterSubmersible Motor Pump
18 Amarex N
Amarex N F 50-220, n = 3500 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6050220FE/0
0 10 20 30 40 50Q [m³/h]
0 50 100 150 200Q [US.gpm]
0 50 100 150Q [IM.gpm]
10
15
20
25
30
35
H [m]
20
40
60
80
100
H [ft]
0 2 4 6 8 10 12Q [l/s]
2
4
P [kW]
2
4
6
P [hp]
0 10 20 30 40 50Q [m³/h]
ø140
ø140
ø130
ø130
ø120
ø120
ø110
ø110
Qmax
43.5
42
42
40
40
36
30
20
45.9
42
42
40
40
36
30
20
46.7
42
42
40
40
36
36
3020
47.0
42
42
40
40
36
36
3020
η [%]
Free passage = 40 mm
Waste WaterSubmersible Motor Pump
Amarex N 19
Amarex N F 65-170, n = 3500 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6065170FE/0
0 10 20 30 40 50 60 70Q [m³/h]
0 100 200 300Q [US.gpm]
0 100 200Q [IM.gpm]
5
10
15
20
H [m]
20
40
60
H [ft]
0 5 10 15 20Q [l/s]
2
3
4
5
P [kW]
4
6
P [hp]
0 10 20 30 40 50 60 70Q [m³/h]
ø136
ø136
ø128
ø128
ø120
ø120
ø112
ø112
Qmax
39.2
38
38
35
35
30
30
20
10
40.8
40
40
38
38
35
35
30
2010
40.7
40
40
38
38
35
35
30
30
2010
39.3
38
38
35
35
30
30
20
10
η [%]
Free passage = 65 mm
Waste WaterSubmersible Motor Pump
20 Amarex N
Amarex N F 65-220, n = 1750 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6065220FE/0
0 10 20 30 40 50Q [m³/h]
0 50 100 150 200 250Q [US.gpm]
0 50 100 150 200Q [IM.gpm]
2
4
6
8
10
H [m]
10
20
30
H [ft]
0 5 10 15Q [l/s]
0.5
1.0
1.5
P [kW]
1
2
P [hp]
0 10 20 30 40 50Q [m³/h]
ø175
ø175
ø165
ø165
ø155
ø155
ø145
ø145
ø135
ø135
51.4
51
51
49
49
45
4137
3020
10
50.4
49
49
45
4137
3020
10
54.2
51
51
49
4541
3730
2010
54.2
51
51
49
49
4541
3730
2010
52.3
51
51
49
49
45
45
4137
3020
10
η [%]
Free passage = 65 mm
Waste WaterSubmersible Motor Pump
Amarex N 21
Amarex N F 80-220, n = 1750 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN6080220FE/0
0 20 40 60 80 100 120Q [m³/h]
0 100 200 300 400 500Q [US.gpm]
0 100 200 300 400Q [IM.gpm]
2
4
6
8
10
12
14
16
H [m]
10
20
30
40
50
H [ft]
0 10 20 30Q [l/s]
1
2
3
4
P [kW]
2
4
6
P [hp]
0 20 40 60 80 100 120Q [m³/h]
ø180
ø180
ø165
ø165
ø150
ø150
ø135
ø135
ø120
ø120
Qmax55.4
54
54
50
50
45
45
38
3020
55.3
54
54
50
50
45
3830
20
52.4
50
50
45
45
3830
20
50.0
45
45
3830
20
46.345
45
38
38
3020
η [%]
Free passage = 76 mm
Waste WaterSubmersible Motor Pump
22 Amarex N
Amarex N F 100-220, n = 1750 rpm
Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to§ 4.4.2. The curves refer to the effective motor speed.
The values of the characteristic curves shown were measured at460 V/60 Hz. For characteristic curves at different voltages referto KSB's pump selection program.
AN60100220FE/0
0 20 40 60 80 100 120 140Q [m³/h]
0 200 400 600Q [US.gpm]
0 100 200 300 400 500Q [IM.gpm]
2
4
6
8
10
12
14
H [m]
10
20
30
40
H [ft]
0 10 20 30 40Q [l/s]
1
2
3
4
P [kW]
2
4
6
P [hp]
0 20 40 60 80 100 120 140Q [m³/h]
ø180
ø180
ø165
ø165
ø150
ø150
ø135
ø135
ø120
ø120
Qmax
51.6
50
50
48
48
45
45
40
40
35
35
2820
10
48.7
48
48
45
45
40
40
35
35
2820
10
44.7
40
40
35
35
28
28
2010
41.3
40
40
35
35
28
28
2010
36.735
35
28
28
2010
η [%]
Free passage = 100 mm
Waste WaterSubmersible Motor Pump
Amarex N 23
Dimensions and connections
Connections
Discharge line connections at the duckfoot bend
Flanged connection (DN 50/DN 65) Threaded connection in the flange(DN 50/DN 65)
Clamped connection (DN 50/DN 65)
P2 / P4P27
P2 / P4
P8
P2 / P4
For standard pipes to DIN 2440 / DIN 2441
▪ With outside diameter of 60.3 mm,steel for DN 50
▪ With outside diameter of 63 mm, PVC(ISO 3606) for DN 50
▪ With threaded flange DN 50 - G 2″▪ With outside diameter of 76.1 mm,
steel for DN 65
▪ With outside diameter of 75 mm, PVC(ISO 3606) for DN 65
▪ With threaded flange DN 65 - G 2 1/2″
For standard pipes to DIN 2440 /DIN 2441 / DIN 2448
▪ With outside diameter of 60.3 mm,steel for DN 50
▪ With outside diameter of 63 mm, PVC(ISO 3606) for DN 50
▪ With outside diameter of 76.1 mm,steel for DN 65
▪ With outside diameter of 75 mm, PVC(ISO 3606) for DN 65
Waste WaterSubmersible Motor Pump
24 Amarex N
Dimensions
Amarex N, transportable model
2)
1)
b2
e2
a 2
R2
DN2
DN1
b3
f 2
1) Lowest switch-off point for automatic operation2) Minimum submergence for continuous operation
Pump dimensions [mm]
Size Pump
DN1 DN2 a2 20) b2 b3 e2 f2
20) R2
50-170 S - 50 547 322 293 180 152 20750-170 F 50 50 547 322 293 180 152 20750-220 S - 50 609 336 307 180 155 20350-220 F 50 50 609 336 307 180 155 20365-170 F 65 65 653 367 338 210 164 24865-220 F 65 65 593 353 347 210 163 25380-220 F 80 80 672 386 392 230 187 249100-220 F 100 100 698 383 390 230 207 277
Connection elbow with flange/hose connection (P13)
D1
DN L 1
C1
Dimensions [mm]
DN D1 C1 L1
65 75 40 13580 75 115 175100 110 45 195
Connection elbow with flanges (P14)
DN3
L 2
C2
DN
Dimensions [mm]
DN DN321) C2 L2
65 65 135 13580 80 135 135100 100 120 175
Connection elbow with internal and external thread(P14) and threaded flange (P27)
DN3
L 2
C2
DN 50PN 16
Dimensions [mm]
DN DN3 C2 L2
50 G 2″ 78 58
Pump flange DN₂
DN 50 und 65ISO 7005 PN 16DIN 2501 PN 16
DN 80 und 100ISO 7005 PN16DIN 2501 PN16
Hf
kf
Zf x R9,5
Df
DN2
Z f x
R9,5kf
Df
Hf
22°30‘
22
°30
‘
DN2
Dimensions of the pump flange in [mm]
Size Flange
Hf kf Df Zf
50-170 S 125 125 140 450-170 F 125 125 140 450-220 S 125 125 140 450-220 F 125 125 140 465-170 F 144 145 164 465-220 F 144 145 164 480-220 F 180 160 180 4100-220 F 202 180 205 4
20) If a foot plate is fitted, a₂ + 10 mm21) DN₃ to ISO 7005/DIN 2501
Waste WaterSubmersible Motor Pump
Amarex N 25
Amarex N 50, stationary installation with guide wire, single guide rail and guide hoop arrangement, straight claw
DN 3 = DN 50: DIN ISO ASME = standard
Guide wire arrangement Single guide rail arrangement Guide hooparrangement
1)
2)
3)
a)
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
60
85100
Ø10
k1
b1
125DN3
125
125
Ø10DN1
l1
h1
R1
R3 a 1
f 1
g20
60
B
C
AA
50
512 15
1220
79
B
76 85
Ø10
Ø33,7 x 3,2
113 DN3
E
E50
20
12
512 15
b)
1800
125DN3
AA AA
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimumb) Maximum
Dimensions of pump and foundation [mm]
Size Pump Foundation
DN1 DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3 Zf DN3 N O P
50-170 S - 50 470 376 250 105 200 31 472 502 125 161 501 4 50 465 465 35050-170 F 50 50 470 376 250 105 200 31 472 502 125 161 501 4 50 465 465 35050-220 S - 50 532 389 254 105 200 27 488 514 129 153 559 4 50 465 465 35050-220 F 50 50 532 389 254 105 200 27 488 514 129 153 559 4 50 465 465 350
Installation in the sump
185
25
100
120
80110
12 12
125
A - A C
DN2
O a)
P a)
dm
N a)
Pump flange DN₂ Flanged bend DN₃ISO 7005 PN10/16 DIN 2501 PN10/16
ISO 7005 PN 10 - PN16 DIN 2501 PN10 - PN16ASME 2″ASME B16.1 class 125
Ø120,5
ASME 2″
130
120
Ø125 DN50 PN10-PN16
4 x 18+250
Ø102
125
DN2
Zf x R 9,5
Ø125 140
Clamped connection
(PVC) NF EN 1452-2
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
Ø63Ø60,3
G
G
Waste WaterSubmersible Motor Pump
26 Amarex N
Amarex N 50, stationary installation with guide wire, single guide rail and guide hoop arrangement, inclined claw
DN 3 = DN 50: DIN ISO ASME = standard
Guide wire arrangement Single guide rail arrangement Guide hooparrangement
3)
2563:129
2)
1)
a)
b)
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
k1
b1
C
B
125 DN3
125
125Ø10
l1
R3 a 1
R1
h1
20f 1
g
60Ø
10
60
85
1050
20 12
79
512 15
B
AA
E
E
76 85
Ø10
Ø33,7 x 3,2
113 DN3
50
2012
5
1512
1800
A AØ10
125
125
125DN3
60f 1
g
AA
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimumb) Maximum
Dimensions of pump and foundation [mm]
Size Pump Foundation
DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3 Zf DN3 N O P
50-170 S 50 495 421 250 105 200 58 500 526 125 220 550 4 50 480 480 35050-220 S 50 556 416 254 105 200 54 506 532 129 230 606 4 50 480 480 350
Installation in the sump
185
25
100
120
80110
12 12
125
A - A C
DN2
O a)
P a)
dm
N a)
Pump flange DN₂ Flanged bend DN₃ISO 7005 PN10/16 DIN 2501 PN10/16
ISO 7005 PN16 DIN 2501 PN16ASME 2″ASME B16.1 class 125
Ø120,5
ASME 2″
130
120
Ø125 DN50 PN10-PN16
4 x 18+250
Ø102
125
DN2
Zf x R 9,5
Ø125 140
Clamped connection
(PVC) NF EN 1452-2
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
Ø63Ø60,3
G
G
Waste WaterSubmersible Motor Pump
Amarex N 27
Amarex N 50, stationary installation with twin guide rail arrangement, inclined claw
DN 3 = DN 50: DIN ISO ASME = standard
Twin guide rail arrangement
1)
2)
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
76E
85
k1
b1
113
DN3R3
R1
a 1h
1
DN1
l1
125Ø10 60f 1
gØ
10
50
55
70
50
1212
D
A A
E
3)Ø33,7 x 3,2
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimum
Dimensions of pump and foundation [mm]
Size Pump Foundation
DN1 DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3 Zf DN3 N O P
50-70 S - 50 494 422 250 105 200 54 499 528 125 220 550 4 50 480 480 35050-170 F 50 50 494 422 250 105 200 54 499 528 125 220 550 4 50 480 480 35050-20 S - 50 549 426 254 105 200 53 506 535 129 230 606 4 50 480 480 35050-220 F 50 50 549 426 254 105 200 53 506 535 129 230 606 4 50 480 480 350
Installation in the sump
a)
a)
a)
A - A D125
12 12
100
120
80110
25
185
O
DN2
P dm
N
Flanged bend DN₃ ISO 7005 PN16 DIN 2501 PN16ASME 2″ASME B16.1 class 125
Ø120,5
ASME 2″
130
120
Ø125 DN50 PN10-PN16
4 x 18+250
Ø102
Clamped connection
(PVC) NF EN 1452-2
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
Ø63Ø60,3
G
G
Waste WaterSubmersible Motor Pump
28 Amarex N
Amarex N 65, stationary installation with guide wire, single guide rail and guide hoop arrangement
DN 3 = 65/65: DIN ISO ASME = standard - DN 3 = 65/80: DIN ISO = standard, ASME = variant
Guide wire arrangement Single guide rail arrangement Guide hooparrangement
1)
2)
b)
a)
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
3)
B60
Ø10
85
100C
k1
b1
R3 a 1
R1
h1
165 DN3
20
g
f 160
l1
DN1
Ø10
B
79
20
50
512 1512
E
50
E
20 12
12 15
5Ø1076 85
Ø33,7 x 3,2
153 165 DN3
1800
AA 165 A AA A
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimumb) Maximum
Dimensions of pump and foundation [mm]
Size Pump Foundation
DN1 DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3 Zf DN3 N O P
65–170 F 65 65 578 422 251 150 260 61 558 583 127 234 639 4 65 500 500 40065–220 F 65 65 518 407 265 150 260 63 544 569 142 241 581 4 65 500 500 400
Installation in the sump
165
A - A C
12
120
85
25
215
120
140
d
O a)
mN
a)
DN2
P a)
Flanged elbow DN
DN 65/65
ISO 7005 PN16DIN 2501 PN16
ASME B 16.1 class 125 2 1/2 ″
Df
Ø65 gf
k f
Zf x 21
150
Df
Ø65 gf
k f
Zf x 21
150
Dimensions of the flanged elbow DN3 [mm]
Flange design DN3 gf kf Df Zf
ISO 7005 PN16DIN 2501 PN16
65 122 145 140 480 133 160 200 8
ASME B16.1 class 125 65 122 140 140 480 127 152,5 191 4
Waste WaterSubmersible Motor Pump
Amarex N 29
Extension elbow DN3
DN 65/80
ISO 7005 PN16DIN 2501 PN16
ASME B 16.1 class 1253″
25 25
gf
k f
Zf x 19
Zf x 18
Df gf
k f
Df
Ø80
Ø80
Clamped connection
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
(PVC) NF EN 1452-2
Ø75
DØ76,1
D
Waste WaterSubmersible Motor Pump
30 Amarex N
Amarex N 65, stationary installation with twin guide rail arrangement
DN 3 = 65/65: DIN ISO ASME = standard - DN 3 = 65/80: DIN ISO = standard, ASME = variant
Twin guide rail arrangement
1)
2)
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
76E
85
Ø10
k1
D
b1
153
DN3
16510l1
DN1
R3
R1
a 1h
1
A A
60f 1
g
3)
Ø33,7 x 3,2
70E50
12
12
50
55
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimum
Dimensions of pump and foundation [mm]
Size Pump Foundation
DN1 DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3 Zf N O P
65–170 F 65 65 578 468 251 150 260 61 588 613 127 234 639 4 550 550 40065–220 F 65 65 518 454 265 150 260 63 574 599 142 241 581 4 550 550 400
Installation in the sump
a)
165
A - A D
12
25
215
120
85 120
140
d
m
P
O
DN2
N
a)
a)
Flanged elbow DN
DN 65/65
ISO 7005 PN16DIN 2501 PN16
ASME B16.1 class 1252 1/2″
Df
Ø65 gf
k f
Zf x 21
150
Df
Ø65 gf
k f
Zf x 21
150
Dimensions of the flanged elbow DN3 [mm]
Flange design DN3 gf kf Df Zf
ISO 7005 PN16DIN 2501 PN16
65 122 145 140 480 133 160 200 8
ASME B16.1 class 125 65 122 140 140 480 127 152,5 191 4
Waste WaterSubmersible Motor Pump
Amarex N 31
Extension elbow DN3
DN 65/80
ISO 7005 PN16DIN 2501 PN16
ASME B16.1 class 1253″
25 25
gf
k f
Zf x 19
Zf x 18
Df gf
k f
Df
Ø80
Ø80
Clamped connection
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
(PVC) NF EN 1452-2
Ø75
DØ76,1
D
Waste WaterSubmersible Motor Pump
32 Amarex N
Amarex N 80 and 100, stationary installation with guide wire and single guide rail arrangement
DN 3 = 80/80: DIN ISO = standard, ASME = variant - DN 3 = 80/100 or 100/100: DIN ISO ASME = standard
Guide wire arrangement Single guide railarrangement
2)
1)
Ø 60,3 x 3,6DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
a)
3)
B60
100
85
Ø10
C
k1
b1
G
DN3
H
DN1
l1
ØK
h1
a 1
R1
R3
gL
f 1
50B
20 12
165
15
125 Ø10
8560
50
20 12
512 15
G1 DN3
H
E
E
A A A A
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimum
Pump dimensions [mm]
Size Pump
DN1 DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3
80-220 F 80 80 582 478 322 200 320 103 604 694 176 262 685100-220 F 100 100 603 476 318 210 345 98 641 691 169 280 701
Dimensions of the foundation in [mm]
Size Foundation
DN3 A B C D E G G1 H J øK L N O P
80-220 F 80 300 200 220 150 40 172,5 163 170 20 18 110 550 550 40080-220 F 100 300 200 220 150 40 172,5 163 170 20 18 110 550 550 400100-220 F 100 300 200 220 150 40 212,5 203 210 20 18 110 550 550 400
Installation in the sump
a)
a)
a)
B
A - A C
DB D
C
AE
O
DN2
dm
P
N
Flanged bend DN
DN 80/80ISO 7005 PN16DIN 2501 PN16
DN 80/80ASME B16.1 class 1253″
DN 100/100ISO 7005 PN16DIN 2501 PN16ASME B16.1 class 1254″
gf
DN3 k f
Df
Z f x 18
Zf x R9,5
gf
k f
Df
Ø80
Waste WaterSubmersible Motor Pump
Amarex N 33
Extension elbow DN3
DN 80/100ISO 7005 PN16DIN 2501 PN16
DN 80/100ASME B16.1 class 1254″
25
gf
k f
Zf x 19
Df
Ø10
0
Df
gf k f
Z f x 19
DN 3
Dimensions of the flanged bend DN3 [mm]
Flange design DN3 gf kf Df Zf
ISO 7005 PN16DIN 2501 PN16
80 132 160 200 8100 156 180 220 8
ASME B16.1 class 125 80 127 152,5 191 4100 156 190,5 220 8
Waste WaterSubmersible Motor Pump
34 Amarex N
Amarex N 80 and 100, stationary installation with twin guide rail arrangement
DN 3 = 80/80: DIN ISO = standard, ASME = variant - DN 3 = 80/100 or 100/100: DIN ISO ASME = standard
Twin guide rail arrangement
2)
1)
DIN 2440DIN 2448NF A 49-004NF A 49-005NF A 49-111NF A 49-117
3)
E 86
85 Ø10
Dk1
b1
G1
DN3
a 1
R3
R1
h1
DN1
l1
Ø18
H
g
f 1
A A
110
E 7050
55
1212
82
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation3) Not included in KSB's scope of supply a) Minimumb) Maximum
Pump dimensions [mm]
Size Pump
DN1 DN2 a1 b1 d f1 g h1 k1 l1 m R1 R3
80-220 F 80 80 582 506 322 200 320 103 630 720 176 262 685100-220 F 100 100 603 529 318 210 345 98 674 724 169 280 701
Installation in the sump
B
A - A
D
D
D B
A
E
C
O a)
P a) d
m DN2
Na)
Dimensions of the foundation in [mm]
Size Foundation
DN3 A B C D E G1 H J N O P
80-220 F 80 300 200 220 150 40 170 170 20 580 580 400100-220 F 100 300 200 220 150 40 210 210 20 600 600 400
Waste WaterSubmersible Motor Pump
Amarex N 35
Flanged bend DN
DN 80/80 ISO 7005 PN16DIN 2501 PN16
DN 80/80ASME B16.1 class 1253″
DN 100/100ISO 7005 PN16DIN 2501 PN16ASME B16.1 class 1254″
g
f
DN3 k f
Df
Z f x 18
Zf x R9,5
gf
k f
Df
Ø80
Extension elbow DN3
DN 80/80ISO 7005 PN16DIN 2501 PN16
DN 80/100ASME B16.1 class 1254″
25
gf
k f
Zf x 19
Df
Ø10
0
Df
gf k f
Z f x 19
DN 3
Dimensions of the flanged bend DN3 [mm]
Flange design DN3 gf kf Df Zf
ISO 7005 PN16DIN 2501 PN16
80 132 160 200 8100 156 180 220 8
ASME B16.1 150 lbs 80 127 152,5 191 4100 156 190,5 220 8
Waste WaterSubmersible Motor Pump
36 Amarex N
Installation types
Overview of installation types
Installation type S - stationary wet installation
P7P4
P5
P1
P7
P4P5
P1
P2
P1P7
P5
Guide hoop arrangement Guide wire arrangement Single guide rail arrangement
P1: pumpP2: installation parts for guidehoop arrangement (Amarex N50 and 65 only),installation depth = 1.5 m /1.8 m / 2.1 mP5: clawP7: chain and shackle, length = 2 m
P1: pumpP4: installation parts for guidewire arrangement, installationdepth = 4.5 mP5: clawP7: chain and shackle,length = 5 m
P1: pump P4: installation parts for singleguide rail arrangementP5: clawP7: chain and shackle, length = 5 m
Installation type P - transportable wet installation
P7
P4P5
P1
P7
P1
P6
Twin guide rail arrangement P1: pumpP4: installation parts for twinguide rail arrangementP5: claw and adapterP7: chain and shackle, length = 5 m
P1: pumpP6: footP7: chain and shackle,length = 5 m
Waste WaterSubmersible Motor Pump
Amarex N 37
Information on installation
Suggested installation layouts for transportable pump setsSize 50
P1
P17
P14
P27
P6
P18P1
P17
P14
P6
P27
P1
P27 P17 P18
P6
Suggestion 1Vertical hose connection with elbow(P14) and Storz rigid coupling (P17)(quick connection)
Suggestion 2Vertical hose connection with plastichose (P18)
Suggestion 3Horizontal hose connection (quickconnection) with plastic hose (P18)
Sizes 65, 80, 100
P19P1P20P16P15
P26
P14P25
P6
P19
P1
P20
P13
P25
P6
P1
P25 P15 P16 P20 P19
P6
Suggestion 1Vertical hose connection (quickconnection) with plastic hose (P19)and hose clip (P20)
Suggestion 2Vertical hose connection with plastichose (P19), hose clip (P20) andconnection elbow (P13)
Suggestion 3Horizontal hose connection (quickconnection) with plastic hose (P19),hose clip (P20), Storz hose coupling(P16), Storz rigid coupling (P15)
P1 to P27 (⇨ Page 42)
Waste WaterSubmersible Motor Pump
38 Amarex N
Suggested installation layouts for stationary pump setsSizes 50, 65, 80, 100Guide hoop arrangementAmarex N S 50-172/F 50-170, S 50-222/F 50-220, F 65-170/65-220
Suspended installationAmarex N S 50-172/F 50-170, S 50-222/F 50-220, F 65-170/65-220
P22
P21
P1
P8/P27
P4
P7P22
P21
P1
P14
P27
P7
Suggestion 1Single-pump stationFlanged duckfoot bend
Suggestion 2Single-pump station for 1.5 m installation depthDirect connection to discharge pipe (suspended installation)
Guide wire, single guide rail or twin guide rail arrangementAmarex N 50, 65, 80, 100
P22a)P24P21a)P23
P1
P8/P27a)
P4
P7
P22a)P24P21a)P23
P4
P7
P1≥ DN1
Suggestion 3Either with guide wire, single guide rail or twin guide railarrangementSingle-pump station for 4.5 m installation depthFlanged duckfoot bend
Suggestion 4Either with guide wire, single guide rail or twin guide railarrangementDual-pump station for 4.5 m installation depthFlanged duckfoot bend
a) DN 50 only
Waste WaterSubmersible Motor Pump
Amarex N 39
DimensionsGuide wire arrangementAmarex N 50, 65, 80, 100
DN2
GK
B
≥ DN 1
L
ØA
≥ DN1
E
ØD
E
Na)
Ma)
O
Single-pump station for 4.5 m installation depthFlanged duckfoot bend
Dual-pump station for 4.5 m installation depthFlanged duckfoot bend
a) Minimum
Dimensions [mm]
Amarex N Ø A B Ø D E G K L M N O DN 1 DN2
S 50-170 /F 50-170
1 pump 625 165 1000 - 75 150 42 - - - 50 502 pumps - 235 1000 300 75 150 - 550 700 200 50 50
S 50-220 / F 50-220
1 pump 625 165 1000 - 75 150 42 - - - 50 502 pumps - 235 1000 300 75 150 - 550 700 200 50 50
F 65-170 / F 65-220
1 pump 625 175 1000 - 180 260 92 - - - 65 652 pumps - 360 1200 600 180 260 - 550 1000 135 65 65
F 80-220 1 pump 625 200 1000 - 180 260 25 - - - 80 802 pumps - 320 1200 600 180 260 - 600 1000 168 80 80
F 100-220 1 pump 625 200 1000 - 190 300 65 - - - 100 1002 pumps - 320 1200 600 190 300 - 600 1000 128 100 100
Waste WaterSubmersible Motor Pump
40 Amarex N
Suggested electrical installation layouts
Amarex N is available in explosion-proof and non-explosionproof design.
CEE motor protection switch (up to 4.0 kW) E4/E11, E14, E17, E19E50
E51E52E53
E60
E50E51E52E53
E20, E21, E23, E24
E63
Suggested installation layout No. 1 Suggested installation layout No. 2Non-explosionproof Explosion-proof
Scope of supply
Wet-installed stationary pump sets
▪ Pump set, complete with power cable
▪ Claw with sealing element (O-ring) and mountingelements
▪ Lifting rope/lifting chain22)
▪ Mounting bracket with mounting elements
▪ Duckfoot bend with mounting elements
▪ Guiding accessories(guide rails are not included in KSB's scope of supply)
Wet-installed transportable pump sets
▪ Pump set, complete with power cable
▪ Feet (and foot plate, if applicable)
▪ Lifting rope/lifting chain23)
22) Optional23) Optional
Waste WaterSubmersible Motor Pump
Amarex N 41
Accessories
Installation parts for stationary pump sets
Overview of installation parts for stationary installation
Item Description Sizes Connection/installation depth
Mat. No. [kg]
Guide hoop arrangementP2 +P5
Installation parts for stationary wetinstallation (guide hoop arrangement)
Consisting of: DN 50 flanged duckfoot bend,stainless steel anchor bolts, guide rail, clawwith stainless steel screws/bolts
Amarex DN 50,DN 3: DIN ISOASMEstraight claw
Inst. depth 1.5 m 39022210 9Inst. depth 1.8 m 39022211 10Inst. depth 2.1 m 39022212 11
Amarex N DN 50,DN 3: DIN ISOASMEinclined claw
Inst. depth 1.5 m 39022213 14Inst. depth 1.8 m 39022214 15Inst. depth 2.1 m 39022215 14
P2 +P5
Installation parts for stationary wetinstallation (guide hoop arrangement)
Consisting of: DN 65 flanged duckfoot bend,stainless steel anchor bolts, guide hoop, clawwith stainless steel screws/bolts
Amarex N DN 65,DN 3: DIN ISOASME
1,5 m 39020827 14.51,8 m 39020828 15.52,1 m 39020829 17
P2 +P5
Installation parts for stationary wetinstallation (guide hoop arrangement)
Consisting of: DN 65/80 flanged duckfootbend, stainless steel anchor bolts, guide rail,claw with stainless steel screws/bolts
Amarex N DN65/80,DN 3: DIN/ISO
Inst. depth 1.5 m 39020848 16Inst. depth 1.8 m 39020849 17Inst. depth 2.1 m 39020850 18.5
Amarex N DN65/80,DN 3: ASME
Inst. depth 1.5 m 39022255 16Inst. depth 1.8 m 39022256 17Inst. depth 2.1 m 39022257 16
Guide wire arrangementP4 +P5
Installation parts for stationary wetinstallation, installation depth 4.5 m (guidewire installation)
Consisting of: flanged duckfoot bend,stainless steel anchor bolts, suspensionbracket, mounting bracket, 10 m guide wire,claw with stainless steel screws/bolts
Amarex Nstraight claw
DN 50, DN 3: DIN ISO ASME 39022196 13
Amarex Ninclined claw
DN 50, DN 3: DIN ISO ASME 39022200 18
Amarex N DN 65, DN 3: DIN ISO ASME 39020820 15Amarex N DN 65/80, DN 3: DIN/ISO 39020834 19.1Amarex N DN 65/80, DN 3: ASME 39020838 19.1Amarex N DN 80, DN 3: DIN/ISO 39020988 35Amarex N DN 80, DN 3: ASME 39020992 41Amarex N DN 80/100, DIN ISO ASME 39021002 31.5Amarex N DN 100, DIN ISO ASME 39021009 41
Single guide rail arrangementP4 +P5
Installation parts for wet-installed stationarypump sets (single guide rail arrangement) forinstallation depth = 4.5 m
Consisting of: flanged duckfoot bend,stainless steel anchor bolts, mountingbracket, claw with stainless steel screws/bolts(guide rail not included in KSB's scope ofsupply)
Amarex Nstraight claw
DN 50, DN 3: DIN ISO ASME 39022204 12.5
Amarex Ninclined claw
DN 50, DN 3: DIN ISO ASME 39022207 18.5
Amarex N DN 65, DN 3: DIN ISO ASME 39021191 14.8Amarex N DN 65/80, DN 3: DIN/ISO 39021194 18.7Amarex N DN 65/80, DN 3: ASME 39021197 19.2Amarex N DN 80, DN 3: DIN/ISO 39021200 26Amarex N DN 80, DN 3: ASME 39021203 29.6Amarex N DN 80/DN 100, DN 3: DIN
ISO ASME39021206 31
Amarex N DN 100, DN 3: DIN ISOASME
39021209 26.8
Twin guide rail arrangementx2
x4
x4
P4 +P5
Installation parts for stationary wetinstallation (twin guide rail arrangement)
Consisting of: flanged duckfoot bend,stainless steel anchor bolts, mountingbracket, adapter, claw with stainless steelscrews/bolts (guide rails not included in KSB'sscope of supply)
Amarex Ninclined claw
DN 50, DN 3: DIN ISO ASME 39023002 14
Amarex Nstraight claw
DN 65, DN 3: DIN ISO ASME 39023006 19.5DN 65/80, DN 3: DIN/ISO 39023009 22.8DN 65/80, DN 3: ASME 39023012 24.5DN 80, DN 3: DIN/ISO 39023018 32DN 80, DN 3: ASME 39023021 32DN 80/100, DN 3: DIN ISOASME
39023024 34
DN 100, DN 3: DIN ISOASME
39023027 34
Claw
Waste WaterSubmersible Motor Pump
42 Amarex N
Item Description Sizes Connection/installation depth
Mat. No. [kg]
P5 Claw for Amarex N JL 1040 with stainless steelscrews/bolts
Guide hoop arrangement for DN 50 and DN65; guide wire and single guide railarrangement for all DN
Amarex Nstraight claw
DN 50 39022248 1.1
Amarex Ninclined claw
DN 50 39022252 7
Amarex N DN 65 39021018 1.9Amarex N DN 80/DN 100 39021020 3.1
P5 Claw for Amarex N JL 1040 with stainless steelscrews/bolts
Twin guide rail arrangement
Amarex Ninclined claw
DN 50 39022990 6
Amarex Nstraight claw
DN 65 39022993 7.3DN 80 39022996 9.7DN 100 39022999 14.7
Claw for Amarex JL1040 with stainless steelscrews/bolts
Guide wire, single guide rail, guide hooparrangement
Amarexstraight claw
DN 50 39021016 1.1
Amarexinclined claw
DN 50 19551046 5
Amarex DN 65 39021018 1.9DN 80/DN 100 39021020 3.1
Lifting bail
x 2
x 4
Lifting bail made of stainless steel 1.4306 withA4-70 bolts, for lowering the pump set at anangle
Amarex N DN 50 39022395 0.6
x 2
x 4
DN 65/DN 80/DN 100 39018004 1
x 2
x 4
Lifting bail made of stainless steel 1.4306
with A4-70 screws/bolts, for lowering thepump set in a vertical position
Amarex N DN 32/50 39023593 0.85
x 2
x 4
Amarex N DN 65/DN 80/DN 100 39023594 1.2
Conversion parts Parts for conversion to twin guide rail
arrangement, consisting of: mountingbracket, stainless steel screws/bolts, adapter,anchor bolts
Note: required for conversion of guide hoop,guide wire or single guide rail arrangementto twin guide rail arrangement
Note: for twin guide rail arrangements a clawis mandatory.
DN 50/DN 65 39022984 1.4DN 80/DN 100 39022987 2.5
Off-standard designs on request.
Installation parts for transportable pump sets
Overview of installation parts for transportable pump sets
Item Description Sizes Mat. No. [kg]
P6 3 feet Amarex N DN 50, 65, 80, 100 39022260 0.4Foot plate incl. bolts
(only for uneven mounting surfaces and incombination with feet)
Amarex N DN 50, 65, 80, 100 39022262 0.9
Waste WaterSubmersible Motor Pump
Amarex N 43
Chain for stationary and transportable pump sets
Overview of chains for stationary and transportable pump sets
Item Description Sizes Mat. No. [kg]P7 Chain (1.4404) short-linked, tested and duly labelled to Directive
2006/42/EC (Machinery Directive), hook (1.4301), shackle (1.4404)
Maximum load: 160 kg
2 m Amarex N DN 50, 65 39023811 1.23 m Amarex N DN 50, 65, 80, 100 39023812 1.65 m Amarex N DN 50, 65, 80, 100 39023813 2.410 m Amarex N DN 50, 65, 80, 100 39023814 4.4
Polypropylene lifting rope with shackle 1.4401 and hook1.457124)
5 m Amarex N DN 50, 65, 80, 100 39021975 2.5
Pump accessories
Overview of accessories for stationary and transportable pump sets
Item Description Connection Amarex N Mat. No. [kg]
50 65 80 100
P8 Flange for pipe coupling PN 10, at the flangedelbow, mating dimensions to PN 16
DN 50/R2" pipe ✘ - - - 19551111 1.2DN 65/R2½" pipe - ✘ - - 39020184 1.2
P9 PVC adapter for hose connection, with 1 hoseclip, plastic hose of inner diameter 63 item 19
R2" ✘ - - - 11191498 0.3
P13 Connection elbow with flange/hose connectionmade of JL 1040, grey cast iron
PN 16, DIN 2501, including joint ring and hoseclip; for DN 100 also with fixing bolts
To be used for flange connections item 25 / item26 (not for DN 100).
DN 65/B 75 - ✘ - - 19135655 6DN 80/B 75 - - ✘ - 19131746 6.6DN 100/A 110 - - - ✘ 19139718 10
P14 Elbow with external/internal thread (to be usedfor flange connections item 27 /item 30),galvanised grey cast iron
R2" ✘ - - - 00241966 0.3
Connection elbow with flanges PN 16, DIN 2501(to be used for flange connections item 25 / item26), grey cast iron
DN 65/65 - ✘ - - 00265480 11DN 65/80 - ✘ - - 25198402 8DN 80/80 - - ✘ - 11150856 10DN 100/100 - - - ✘ 25145802 14.4
P15 Storz rigid coupling with flange, to DIN 2501,drilled to PN 16 (to be used for flangeconnections item 25 / item 26), aluminium/steel
DN 65/B 75 - ✘ - - 18040148 3.5DN 80/B 75 - - ✘ - 18072642 3.5DN 100/A 110 - - - ✘ 18060162 5
P16 Storz hose coupling, aluminium alloy
2 hose clips, item 20, are required for hosemounting (for plastic hoses B 75 and A 110, item19)
C 52 (DIN 14321) ✘ - - - 00524551 0.3B 75 (DIN 14322) - ✘ ✘ - 00520454 0.7A 110 (DIN 14323) - - - ✘ 00522313 1.5
P17 Storz rigid coupling with external thread, DIN ISO228/1
C 52/G 2 A ✘ - - - 00524370 0.2B 75 - G 2½ - ✘ - - 00524371 0.4
P18 Plastic hose DN 50, DIN 14811, with integrated Ccouplings
C 52-5 m ✘ - - - 00522262 2.3C 52-10 m ✘ - - - 00522263 4.2C 52-20 m ✘ - - - 00522264 5.7
P19 Plastic hoseWithout coupling, DIN 14 811
Inside diameter63
5 m ✘ - - - 39018688 1.710 m ✘ - - - 39018689 3.420 m ✘ - - - 39018690 6.8
B 75 5 m - ✘ ✘ - 39019064 220 m - ✘ ✘ - 39019066 830 m - ✘ ✘ - 39019071 12
24) Increase quantity for larger installation depths.
Waste WaterSubmersible Motor Pump
44 Amarex N
Item Description Connection Amarex N Mat. No. [kg]
50 65 80 100
Inside diameter80
5 m - - ✘ - 39018691 2.210 m - - ✘ - 39019062 4.3
A 110 5 m - - - ✘ 39019067 4.710 m - - - ✘ 39019068 9.330 m - - - ✘ 39019070 27.9
P20 Hose clip DIN 3017, chrome steel B 5025) ✘ - - - 39000515 0.03B 75 - ✘ ✘ - 00109515 0.04AL 110 - 120 B26) - - - ✘ 00520853 0.1
P21 RK swing check valve
Plastic, EN 12 050-4, with internal thread ISO 7/1,full port and drain plug; cannot be used forpumped drainage
Rp 2 ✘ - - - 01009773 0.5
P22 Socket gate valve CuZn PN 10-12 DIN 3352 Rp 2 ✘ - - - 00411503 1.1Rp 2½ - ✘ - - 39000507 1.7
P23 KSB check valve, grey cast ironWith full port, backwash device, flanges drilled toDIN 2501, PN 16 (not for lifting units)
DN 65 - ✘ - - 48829253 16.2DN 80 - - ✘ - 48829254 21.5DN 100 - - - ✘ 48829255 29
P24 ECOLINE GTR-16P gate valve, grey cast iron,PN 16, flanges drilled to ISO 7005/DIN 2501
DN 65 - ✘ - - 49709579 15DN 80 - - ✘ - 49709580 22DN 100 - - - ✘ 49709581 26.5
P25 Set of installation accessories for a flange connection, discharge nozzle;item 13, 14 or 15
Consisting of: 4 hexagon head bolts with nuts and 1 sealing element
✘ - - - 39021944 0.8- ✘ - - 19551115 0.8- - ✘ - 19551100 0.8- - - ✘ 19551113 0.8
P26 Set of installation accessories for a flange connection,
Consisting of: 8 hexagon head bolts with nuts and 1 sealing element
- - ✘ - 19551114 0.8- - - ✘ 19551116 0.8
P27 Threaded flange for guide hoop arrangement(P2) and guide wire arrangement (P4)
Consisting of: flange, 4 hexagon head bolts withnuts and discs, and 1 sealing element
DN 50/Rp 2 ✘ - - - 19551353 2DN 65/Rp 2½ - ✘ - - 39021943 2.9
P28 Hand pump, wall mounting, grey cast iron, suction-side connection Rp1½
✘ ✘ ✘ ✘ 00520485 12
P30 Adapter with reduced external thread M4 EN1042K
2 x 1¼ - - - - 01135663 0.4
25) For plastic hose Ø 63 item 1926) 2 units required
Waste WaterSubmersible Motor Pump
Amarex N 45
Electrical accessories
Control units, non-ATEX compliant
Control units for Amarex N, non-ATEX compliant
Item Description Powermin[A]
Powermax[A]
Type Mat. No. [kg]
E4 Multi-functional plug, type Hyper, with motor protection relayCEE plug
2,6 3,7 Hyper 37.1 19071492 13,7 5,5 Hyper 55.1 19071493 15,5 8,0 Hyper 80.1 19071494 18,0 11,5 Hyper 115.1 19071495 1
LevelControl Basic 2 control unit for single-pump station, IP 54
E11 For float switch or 4...20 mA sensor, optional with master switch,400 x 278 x 120 mm
2,5 4,0 BC1 400 DFNO 040 19073763 4.54,0 6,3 BC1 400 DFNO 063 19073764 4.56,3 10,0 BC1 400 DFNO 100 19073765 4.5
E14 Pneumatic, optional master switch, 400 x 278 x 120 mm 2,5 4,0 BC1 400 DPNO 040 19073768 4.54,0 6,3 BC1 400 DPNO 063 19073769 4.56,3 10,0 BC1 400 DPNO 100 19073770 4.5
E17 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS1 400 DLNO 040 19073818 124,0 6,3 BS1 400 DLNO 063 19073819 126,3 10,0 BS1 400 DLNO 100 19073820 12
E19 Bubbler control for BC version
Only to be used for connections with neutral conductor!Installation option O1 (master switch) not possible! 400 x 278 x 120mm
2,5 4,0 BC1 400 DLNO 040 19075148 4.54,0 6,3 BC1 400 DLNO 063 19075149 4.56,3 10,0 BC1 400 DLNO 100 19075150 4.5
LevelControl Basic 2 control unit for dual-pump station, IP 54
E 31 For float switch or 4...20 mA sensor, optional master switch,400 x 278 x 120 mm
2,5 4,0 BC2 400 DFNO 040 19073777 4.74,0 6,3 BC2 400 DFNO 063 19073778 4.76,3 10,0 BC2 400 DFNO 100 19073779 4.7
E34 Pneumatic, optional master switch, 400 x 278 x 120 mm 2,5 4,0 BC2 400 DPNO 040 19073782 4.74,0 6,3 BC2 400 DPNO 063 19073783 4.76,3 10,0 BC2 400 DPNO 100 19073784 4.7
E37 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS2 400 DLNO 040 19073860 134,0 6,3 BS2 400 DLNO 063 19073861 136,3 10,0 BS2 400 DLNO 100 19073862 13
E39 Bubbler control for BC version
Only to be used for connections with neutral conductor!Installation option O1 (master switch) not possible! 400 x 278 x 120mm
2,5 4,0 BC2 400 DLNO 040 19075151 4.74,0 6,3 BC2 400 DLNO 063 19075152 4.76,3 10,0 BC2 400 DLNO 100 19075153 4.7
Waste WaterSubmersible Motor Pump
46 Amarex N
Alarm switchgears for pumps without ATEX
AS 0/AS 1/AS 2/AS 4/AS 5
Item Description Mat. No. [kg]
E50 Alarm switchgear AS 0
with circuit breaker, piezoceramic signal transmitter, 85 dB(A) at a distance of 1 m and4.1 kHz, green equipment-on lamp
Plastic housing IP20, 140 x 80 x 57 mm. Use float switch, F1 moisture sensor (item E64), M1alarm contactor or signal relay of control unit as contactor.
29128401 0.5
E51 Alarm switchgear AS 2
with circuit breaker, piezoceramic signal transmitter, 85 dBA at a distance of 1 m and 4.1kHz, green equipment-on lamp, volt-free contact for hook-up to a control station.
Plastic housing IP20, 140 x 80 x 57 mm. Use float switch, F1 moisture sensor (item E64) orsignal relay of control unit as contactor.
29128422 0.5
E52 Alarm switchgear AS 4
with circuit breaker, piezoceramic signal transmitter, 85 dB(A) at a distance of 1 m and4.1 kHz, green equipment-on lamp, volt-free contact for hook-up to a control station, self-charging power supply unit for 5 hours' operation in the event of power failure
Plastic housing IP20, 140 x 80 x 57 mm. Use float switch (E60), F1 moisture sensor (item E64)or signal relay of control unit as contactor.
29128442 0.5
E53 Alarm switchgear AS 5
Mains-independent, with self-charging power supply unit for 10 hours' operation in theevent of power failure, mains pilot LED, fault indicator light, horn-off push button, volt-free contact for hook-up to a control station, ready for connection with 1.8 m connectioncable and plug.
ISO housing IP41, 190 x 165 x 75 mm. Use float switch (E60) or signal relay of control unitas contactor.
00530561 1.7
E55 Alarm switchgear AS 1
In ISO plug housing IP30, mains-independent, with self-charging power supply unit for 5hours’ operation in the event of a power failure, acoustic signal 70 dB(A) with circuitbreaker and integrated signal transmitter with 3-metre connection cable, max. 60 °C, notsuitable for steam and condensate.
1. High water alert by suspending the moisture sensor in a (pump) sump above the pumpstart-up point.
2. Water alarm signal at a water level of only 1 mm (!), by placing the contactor on thefloor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in thekitchen or bathroom.
00533740 0.9
Waste WaterSubmersible Motor Pump
Amarex N 47
Accessories for non-ATEX control units
Overview of control unit accessories for Amarex N, non-ATEX compliant
Item Description Mat. No. [kg]
E60 Float switch with free cable end (NO contact)
Switch housing made of polypropylene (max. fluid temperature70 °C), circuit closed in upper float position, connection cable (H07 RN-F3G1)
3 m 11037742 0.55 m 11037743 0.810 m 11037744 1.315 m 11037745 1.820 m 11037746 2.425 m 11037747 2.930 m 11037748 3.4
E62 Float switch with free cable end (NC contact), circuit open inupper float position, power cable (H 07 RN-F3G1)
5 m 11037756 0.810 m 11037757 1.420 m 11037758 2.6
E64 Leakage sensor F 1 3 m 19072366 0.2
E65 Open pressure bell set - pneumatic and bubbler controlwith polyamide tube 8 x 1 mm
Tube length 10 m 19071721 1.2Tube length 20 m 19071837 2Tube length 50 m 19074200 2.5
E66
Closed pressure bell set - pneumaticwith polyamide tube 8 x 3 mm
Tube length 10 m 19071722 3.5Tube length > 10 m
E70 Horn, 12 V DC, 105 dB(A), 1.2 W 01086547 0.1
E71 Alarm combination, 12 V DC 01139930 0.1
E72 Alarm strobe light, 12 V DC 01056355 0.3
E73 PC service tool 47121210 0.2
E90 Rechargeable battery retrofit kit for LevelControl Basic 2, forpowering the electronics, the float switches or internal pressuresensor and the alarm equipment (buzzer, horn, alarmcombination), for single-pump and dual-pump stations
For type BC, includes 2rechargeable batteries6 V, 1.3 Ah and chargingunit
19074194 0.8
For type BS, consisting of1 rechargeable battery12 V, 1.2 Ah andcharging unit
19074199 1
Waste WaterSubmersible Motor Pump
48 Amarex N
Control units for Amarex N, ATEX-compliant
The control units are not explosion-proof, which meansthat they must not be operated in potentially explosiveatmospheres.
For ATEX-compliant variants, intrinsic safety barriers andan ATEX level switch (float switch) must be fitted. Selection viaKSB EasySelect.
Control unit accessories for Amarex N, ATEX-compliant
Item Description Powermin[A]
Powermax[A]
Type Mat. No. [kg]
LevelControl Basic 2 control unit for single-pump station E20 Float switch, with master switch, 600 x 400 x 200 mm 2,5 4,0 BS1 400 DFEO 040 19073800 12
4,0 6,3 BS1 400 DFEO 063 19073801 126,3 10,0 BS1 400 DFEO 100 19073802 12
E21 Pneumatic, optional master switch, 400 x 278 x 120 mm 2,5 4,0 BC1 400 DPEO 040 19073771 4.54,0 6,3 BC1 400 DPEO 063 19073772 4.56,3 10,0 BC1 400 DPEO 100 19073773 4.5
E23 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS1 400 DLEO 040 19073821 124,0 6,3 BS1 400 DLEO 063 19073822 126,3 10,0 BS1 400 DLEO 100 19073823 12
E24 Bubbler control for BC version
Only to be used for connections with neutral conductor!Installation option O1 (master switch) not possible!400 x 278 x 120 mm
2,5 4,0 BC1 400 DLEO 040 19075154 4.54,0 6,3 BC1 400 DLEO 063 19075155 4.56,3 10,0 BC1 400 DLEO 100 19075156 4.5
LevelControl Basic 2 control unit for dual-pump station E40 Float switch, with master switch, 600 x 400 x 200 mm 2,5 4,0 BS2 400 DFEO 040 19073842 13
4,0 6,3 BS2 400 DFEO 063 19073843 136,3 10,0 BS2 400 DFEO 100 19073844 13
E41 Pneumatic, optional master switch, 400 x 278 x 120 mm 2,5 4,0 BC2 400 DPEO 040 19073785 4.74,0 6,3 BC2 400 DPEO 063 19073786 4.76,3 10,0 BC2 400 DPEO 100 19073787 4.7
E43 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS2 400 DLEO 040 19073863 134,0 6,3 BS2 400 DLEO 063 19073864 136,3 10,0 BS2 400 DLEO 100 19073865 13
E44 Bubbler control for BC version
Only to be used for connections with neutral conductor!Installation option O1 (master switch) not possible!400 x 278 x 120 mm
2,5 4,0 BC2 400 DLEO 040 19075157 4.74,0 6,3 BC2 400 DLEO 063 19075158 4.76,3 10,0 BC2 400 DLEO 100 19075159 4.7
Waste WaterSubmersible Motor Pump
Amarex N 49
Accessories for ATEX-compliant control units
Overview of accessories for Amarex N, ATEX-compliant
Item Description Mat. No. [kg]
E63 Float switch with free cable end(NO contact)With declaration of compliance with explosion protectionstandardsPower cable (H 07 RN-F3G1)
5 m 01148226 0.710 m 01148247 120 m 01148248 2
E65 Open pressure bell set - pneumatic and bubbler controlwith polyamide tube 8 x 1 mm
Tube length 10 m 19071721 1.2Tube length 20 m 19071837 2Tube length 50 m 19074200 2.5
E66 Closed pressure bell set - pneumaticwith polyamide tube 8 x 3 mm
Tube length 10 m 19071722 3.5Tube length > 10 m
E70 Horn, 12 V DC, 105 dB(A), 1.2 W, not explosion-proof 01086547 0.1
E71 Alarm combination, 12 V DC, not explosion-proof 01139930 0.1
E72 Alarm strobe light, 12 V DC, not explosion-proof 01056355 0.3
E73 PC service tool 47121210 0.2
E90 Rechargeable battery retrofit kit for LevelControl Basic 2, forpowering the electronics, the float switches or internal pressuresensor and the alarm equipment (buzzer, horn, alarmcombination), for single-pump and dual-pump stations
For type BC, includes 2rechargeable batteries6 V, 1.3 Ah andcharging unit
19074194 0.8
For type BS, consistingof 1 rechargeablebattery 12 V, 1.2 Ahand charging unit
19074199 1
Waste WaterSubmersible Motor Pump
50 Amarex N
2563
.56/
04-E
N28
.11.
2013
KSB S.A.S.128, rue Carnot • 59320 Sequedin/Lille (France)B.P. 60095 • 59482 Haubourdin Cedex (France)Tel. +33 3 2022-7000 • Fax +33 3 2022-7099www.ksb.com