Alternative Floor Systems of a 20 Storied Concrete v4.0

32
ALTERNATIVE FLOOR SYSTEMS OF A 20 STORIED CONCRETE BUILDING SEMINAR ON : INNOVATION IN HYBRID BUILDING DESIGN

description

Alternative Floor Systems of a 20 Storied Concrete v4.0

Transcript of Alternative Floor Systems of a 20 Storied Concrete v4.0

Page 1: Alternative Floor Systems of a 20 Storied Concrete v4.0

ALTERNATIVE FLOOR SYSTEMS OF A 20 STORIED CONCRETE BUILDING

SEMINAR ON : INNOVATION IN HYBRID BUILDING DESIGN

Page 2: Alternative Floor Systems of a 20 Storied Concrete v4.0

FLOOR SYSTEM 01

• One-way slab, supported by (i) Monolithic concrete beams(ii) Steel beams

• One-way slab with cold-formed steel decking and reinforcement• One-way joist floor (also known as ribbed slab)• Two-way slab supported by edge beams• Flat slabs /plate

(i) With column capitals or drop panels or both, but without beams(ii)without beams and with no drop panels or column capitals

• Two-way joist floors, with or without beams on the column lines

Page 3: Alternative Floor Systems of a 20 Storied Concrete v4.0

One-way slab (Steel or RC Beams) One-way slab with cold-formed steel decking

One-way Joist floor Two-way slab (With Edge Beam)

FLOOR SYSTEM 02

Page 4: Alternative Floor Systems of a 20 Storied Concrete v4.0

Flat Slab with Capital & Drop Two-way joist floors

FLOOR SYSTEM 03

Page 5: Alternative Floor Systems of a 20 Storied Concrete v4.0

RC JOIST

Page 6: Alternative Floor Systems of a 20 Storied Concrete v4.0

OPEN WEB JOIST-01

BENEFITS• Reduced construction time (save on rent and move in sooner).• Floor is easily accessible to accommodate wiring plumbing / AC Service. • All services such as plumbing and electrical are easily accessible after construction enabling alternations to be carried out.

Page 7: Alternative Floor Systems of a 20 Storied Concrete v4.0

OPEN WEB JOIST-02

BENEFITS• Efficient framing system • Economical and lightweight • Exceptionally high strength-to-weight ratio. • Minimize floor-to-floor heightsSince steel joists are lighter than wooden / RC materials, the size of the supporting structural elements as well as the size of the building's foundation can be reduced for cost efficiency.

Page 8: Alternative Floor Systems of a 20 Storied Concrete v4.0

STEEL OPEN WEB JOIST - 01COMPONENTS

Page 9: Alternative Floor Systems of a 20 Storied Concrete v4.0

STEEL OPEN WEB JOIST - 02COMPONENTS

Page 10: Alternative Floor Systems of a 20 Storied Concrete v4.0

COMPOSITE STEEL JOIST - 01

DEFINITION

• Joist top chord and overlying concrete slab will actas an integral unit once the concrete has cured.

• Welded shear studs to ensure adequate transfer of shear

• Simplified erection, faster connections, and minimal crane lifts occur.

Page 11: Alternative Floor Systems of a 20 Storied Concrete v4.0

COMPOSITE STEEL JOIST -02

BENEFITS

• A more efficient and stiffer composite design makes it possible to support a given load with a shallower joist

• Weight savings from the joist design reduces building costs

• Simplified erection, faster connections, and minimal crane lifts occur.

Page 12: Alternative Floor Systems of a 20 Storied Concrete v4.0

COMPARATIVE ANALYSIS

BEAM SUPPORTED AND JOIST SUPPORTED SLAB.

Page 13: Alternative Floor Systems of a 20 Storied Concrete v4.0

CODE & MATERIALCODE AND STANDARD

• Steel Joist Institute (SJI) 2010• Bangladesh National Building Code - 1993 (BNBC)• American Institute of Steel Construction

MATERIAL PROPERTIES

Concrete : fc’ = 4,000 psi.Reinforcement : fy =72,500 psi.Steel Joist : fy = 50,000psi.

Fire Safety & Floor Vibration have not been considered in Joist supported slab.

Page 14: Alternative Floor Systems of a 20 Storied Concrete v4.0

FLOOR PLAN – BEAM SUPPORTED

Weight: 1138 kip / floor i.e 267 lb / sft

Page 15: Alternative Floor Systems of a 20 Storied Concrete v4.0

FLOOR PLAN – JOIST SUPPORTED

Weight: 878 kip / floor i.e 206 lb / sft

Page 16: Alternative Floor Systems of a 20 Storied Concrete v4.0

MEMBER DIMENSIONS

BEAM Supported slab (A) JOIST Supported slab (B)

Slab: 6inch Slab: 3.5inchBeam: 15x24inch Beam: 12X21 inch & 15x24inchColumn:36x36inch (GF-6th) 30x30inch (7th-12th) 24x24inch (13th-Roof)

Column:33x33inch (GF-6th) 27x27inch (7th-12th) 20x20inch (13th-Roof)

Pile Length: 120ft (Cap: 100T) Pile Length: 105ft (Cap: 90T)- Joist : 14K6 (7.7lb/ft)

Page 17: Alternative Floor Systems of a 20 Storied Concrete v4.0

LOADSDEAD

• Self weight & SDEAD load of 60psf.• Live Load : 60psf• Wind Load : BNBC 93, (210kph, Exposure A)• Seismic : BNBC 93 (Zone: 2, I : 1, R:8)

LOAD COMBINATION

RCC structure : BNBC 93 Joist (LRFD) : 1.4 DL (ASCE 2.3.2-1) 1.2 DL + 1.6 LL (ASCE 2.3.2-2)

Page 18: Alternative Floor Systems of a 20 Storied Concrete v4.0

CONCRETE & JOIST JOINT

Page 19: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 01BEAM Supported slab JOIST Supported slab

3.28 inch 3.14 inch

BEAM Supported slab JOIST Supported slab

28639 kip 23440 kip

TOP DEFLECTION

TOTAL BASE REACTION (Full Dead & Live Load)

BEAM Supported slab JOIST Supported slab

267lb/sft 206lb/sft

WEIGHT / sft (Dead Load Alone)

Page 20: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 02-A

Member Type

(A) RC Beam Supported Slab

(B) Joist Supported Slab % Saving

in BQuantity Unit Amount, TK

Quantity Unit Amount, TK

i) Concrete 483 cum 5859297 412 cum 5000564 14.66ii) Shutter 970 sqm 22219 867 sqm 19859 10.62iii) Rebar 116706 kg 11305321 106553 kg 10321758 8.70

SAVINGS IN COLUMN

Page 21: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 02-B

Member Type

(A) RC Beam Supported Slab

(B) Joist Supported Slab

% Saving in B

Quantity Unit Amount,

TKQuantity Unit Amount,

TK

i) Concrete 441 cum 5307032 403 cum 4846616 8.68ii) Shutter 484 sqm 12065 426 sqm 10618 12.00iii) Rebar 132194 kg 12805600 120693 kg 11691513 8.70

SAVINGS IN BEAM

Page 22: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 02-C

Member Type

(A) RC Beam Supported Slab

(B) Joist Supported Slab

% Saving in B

Quantity Unit Amount,

TKQuantity Unit Amount,

TK

i) Concrete 1370 cum 16850049 584 cum 7181791 57.38ii) Shutter 1266 sqm 30802 0 sqm 0 100.00iii) Rebar 161403 kg 15635061 64924 kg 6289182 59.78

SAVING IN SLAB

Page 23: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 02-D

Member Type

(A) RC Beam Supported Slab

(B) Joist Supported Slab

% Saving in BQuantity Unit Amount,

TKQuantity Unit Amount,

TK

i) Concrete 1613.39 cum 18679772 1473.02 cum 17054631 8.70ii) Boring 5700.00 rm 6891300 5278.20 rm 6381344 7.40iii) Rebar 145181 kg 14063693 130662.98 kg 12657323 10.00

SAVING IN FOUNDATION

Page 24: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 02-E

Member Type

(A) RC Beam Supported Slab

(B) Joist Supported Slab

% Saving in BQuantity Unit Amount,

TKQuantity Unit Amount,

TK

i) Joist 0.00 Ton 0 77.00 Ton 6970000 (100)ii) Metal Deck 0.00 Ton 0 45.00 Ton 5400000 (100)

ADDITIONAL COST IN RC JOIST

Page 25: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 02 SUMMARY (A-E)

COST SAVING IN CONCRET, STEEL & REINFORCEMENT

• 9% saving in column / wall.• 9% saving in beam & foundation.• 25% saving in slab (Considering joist cost)

Overall 12~13% cost saving in Joist Supported Slab

Page 26: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 03-AJOIST CALCULATION - 01

DESIGN DATA:JOIST ID : 14K6 (7.7lb/ft)Design Code : SJI 2010Design Type : LRFDMaterial criteria : 50ksi

Page 27: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 03-BJOIST CALCULATION - 02LoadDL-Dead Load : 3.5” slab = 44psf

SDEAD = 60psfLL-Live load : 60 psfFactored Load : 1.2DL+1.6LL = 124.8 + 96 = 220.8psfFactored Load / ft of Joist

= 220.8*3.62 lb/ft = 800lb/ft + 7.7lb/ft = 807.7lb/ft. Allowable Load : 825 lb/ft > 807.7lb/ft

Page 28: Alternative Floor Systems of a 20 Storied Concrete v4.0

OUTPUT 04JOIST ALLOWABLE LOAD TABLE

Page 29: Alternative Floor Systems of a 20 Storied Concrete v4.0

ESTIMATE 01SOURCE: PWD 2014

ABSTRACT OF COST (BEAM SUPPORTED SLAB)

A. CIVIL WORKS: Tk. 118972404

Tk. 118972404

Add @ 5% contingency Tk. 5948620

Total Tk. 124921024

Say Tk. 124,921,100

Rate / sft 1,470

Floor area: 4250 sft (20 Storied Bldg.)

Cost of Foundation, Frame & Slab (Including rebar)

Page 30: Alternative Floor Systems of a 20 Storied Concrete v4.0

ESTIMATE 02SOURCE: PWD 2014

ABSTRACT OF COST (OPEN WEB JOIST SUPPORTED SLAB)

A. CIVIL WORKS: Tk. 10520996Tk. 105209960

Add @ 5% contingency Tk. 5260498Total Tk. 110470458

Say Tk. 110,470,500.00

Rate / sft 1,300

Floor area: 4250 sft (20 Storied Bldg)

Cost of Foundation, Frame, Joist & Slab (Including rebar)

Page 31: Alternative Floor Systems of a 20 Storied Concrete v4.0

ESTIMATE 03SOURCE: PWD 2014

SLAB TYPE Cost /sft

RC BEAM SUPPORTED SLAB Tk1470

STEEL JOIST SUPPORTED SLAB Tk1300

SLAB TYPE Weight / floor

RC BEAM SUPPORTED SLAB 1138 kip (267lb/sft)

STEEL JOIST SUPPORTED SLAB 878 kip (206lb/sft)

Cost include: Foundation, Frame, Joist, Slab & rebar)

Weight include: Dead & SDEAD

Page 32: Alternative Floor Systems of a 20 Storied Concrete v4.0

CONCLUSIONSaving in cost has observed in steel joist supported slab for about 9% in column / wall, beam & foundation, About 25% saving in slab (Considering joist cost).