ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project...

5
600Ø RCP 600Ø RCP 600Ø RCP 1 2 3 4 5 600Ø RCP 6 CITY OF GREATER BENDIGO Survey Scale: Approved by Design Checked GB4413 ALLINGHAM STREET GOLDEN SQUARE DRAINAGE RENEWAL H. WHYTOCK B. JANSSEN L. OLIVER N. SARTORI 08/10/18 12/03/19 - 1 COVER SHEET Revision : File : Original sheet size: AMENDMENTS Approved by Date Revision Description DRAFT 1 PRELIMINARY DESIG Plot Date: BAYLEY JANSSEN Plotted By: 26/03/2019 Sheet: Reference: OF 5 12/03/19 12/03/19 A GB4413.dwg A3 - - - - ALLINGHAM STREET, GOLDEN SQUARE GB4413 DRAINAGE UPGRADE MARCH 2019 PROJECT EXTENTS LOCALITY MAP ALLINGHAM STREET KANGAROO FLAT-BENDIGO RAIL LINE 91-109 ALLINGHAM STREET ORTECH INDUSTRIES Kangaroo Flat - Bendigo Rail Line Allingham Street DOCUMENT CONTROL SHEET No. SHEET DESC. 26/03/19 xx/xx/xx xx/xx/xx DRAFT TENDER CONSTRUCTION ISSUE ISSUE ISSUE 1 COVER SHEET A 2 PLAN VIEW 1 A 3 PLAN VIEW 2 A 4 LONG SECTION A 5 GENERAL NOTES A Oak Street

Transcript of ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project...

Page 1: ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project Manager is to be notified seven days prior to the commencement of Works with a Pre-commencement

600Ø

RC

P

600Ø RCP

6

0

0

Ø

R

C

P

1

2

3

4

5

6

0

0

Ø

R

C

P

6

CITY OF GREATER BENDIGO

Survey

Scale:

Approved by

Design

Checked

GB4413

ALLINGHAM STREET

GOLDEN SQUARE

DRAINAGE RENEWAL

H. WHYTOCK

B. JANSSEN

L. OLIVER

N. SARTORI

08/10/18

12/03/19

-

1

COVER SHEET

Revision :

File :

Original sheet size:

AMENDMENTS

Approved by DateRevision Description

DRAFT 1PRELIMINARY DESIGN

Plot Date:

BAYLEY JANSSENPlotted By:

26/03/2019

Sheet: Reference:

OF 5

12/03/19

12/03/19

A

GB4413.dwg

A3

- - - -

ALLINGHAM STREET, GOLDEN SQUARE

GB4413

DRAINAGE UPGRADE

MARCH 2019

PROJECT EXTENTS

LOCALITY MAP

ALLIN

G

H

AM

ST

R

EE

T

KA

NG

AR

OO

FLA

T-B

EN

DIG

O R

AIL

LIN

E

91-109 ALLINGHAM STREET

ORTECH INDUSTRIES

K

a

n

g

a

ro

o

F

la

t - B

e

n

d

ig

o

R

a

il L

in

e

A

llin

g

h

a

m

S

tre

e

t

DOCUMENT CONTROL

SH

EE

T

No.

SH

EE

T

DE

SC

.

26/03/19

xx/xx/xx

xx/xx/xx

DRAFT TENDER CONSTRUCTION

ISSUE ISSUE ISSUE

1 COVER SHEET A

2 PLAN VIEW 1 A

3 PLAN VIEW 2 A

4 LONG SECTION A

5 GENERAL NOTES A

O

a

k

S

t

r

e

e

t

AutoCAD SHX Text
Cooper
AutoCAD SHX Text
Ash
AutoCAD SHX Text
Baslar
AutoCAD SHX Text
Belinda
AutoCAD SHX Text
Benghasi
AutoCAD SHX Text
Bond
AutoCAD SHX Text
Bowles
AutoCAD SHX Text
Broad
AutoCAD SHX Text
Cogo
AutoCAD SHX Text
Coolbunna
AutoCAD SHX Text
Coonooer
AutoCAD SHX Text
Coonooer
AutoCAD SHX Text
Derna
AutoCAD SHX Text
Doble
AutoCAD SHX Text
Elliott
AutoCAD SHX Text
Elm
AutoCAD SHX Text
Gordon
AutoCAD SHX Text
Graham
AutoCAD SHX Text
Haydrian
AutoCAD SHX Text
Ham
AutoCAD SHX Text
Holly
AutoCAD SHX Text
Lindsay
AutoCAD SHX Text
MacDougall
AutoCAD SHX Text
Manallack
AutoCAD SHX Text
Martin
AutoCAD SHX Text
Maude
AutoCAD SHX Text
McLachlan
AutoCAD SHX Text
McLachlan
AutoCAD SHX Text
Mimosa
AutoCAD SHX Text
Monak
AutoCAD SHX Text
Noble
AutoCAD SHX Text
Osborn
AutoCAD SHX Text
Poplar
AutoCAD SHX Text
Snell
AutoCAD SHX Text
Stoneham
AutoCAD SHX Text
Sunkist
AutoCAD SHX Text
Tucker
AutoCAD SHX Text
Kurrajong
AutoCAD SHX Text
Wireless
AutoCAD SHX Text
Young
AutoCAD SHX Text
Court
AutoCAD SHX Text
Ct
AutoCAD SHX Text
Street
AutoCAD SHX Text
Avenue
AutoCAD SHX Text
Av
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Ct
AutoCAD SHX Text
Court
AutoCAD SHX Text
Close
AutoCAD SHX Text
Street
AutoCAD SHX Text
Av
AutoCAD SHX Text
Court
AutoCAD SHX Text
St
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
St
AutoCAD SHX Text
Court
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
St
AutoCAD SHX Text
Road
AutoCAD SHX Text
St
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Avenue
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
St
AutoCAD SHX Text
Street
AutoCAD SHX Text
Street
AutoCAD SHX Text
St
AutoCAD SHX Text
Street
AutoCAD SHX Text
Potters
AutoCAD SHX Text
La
AutoCAD SHX Text
Ct
AutoCAD SHX Text
Shinda
AutoCAD SHX Text
Rowe
AutoCAD SHX Text
Guidice
AutoCAD SHX Text
Stanistreet
AutoCAD SHX Text
St
AutoCAD SHX Text
Cr
AutoCAD SHX Text
Street
AutoCAD SHX Text
Stoneham
AutoCAD SHX Text
St
AutoCAD SHX Text
Norma
AutoCAD SHX Text
Street
AutoCAD SHX Text
Liepoldt
AutoCAD SHX Text
Rise
AutoCAD SHX Text
Panton
AutoCAD SHX Text
Street
AutoCAD SHX Text
MacCullagh
AutoCAD SHX Text
Street
AutoCAD SHX Text
MacDougall
AutoCAD SHX Text
Panton
AutoCAD SHX Text
St
AutoCAD SHX Text
MACKENZIE ST WEST
AutoCAD SHX Text
OAK STREET
AutoCAD SHX Text
HATTAM
AutoCAD SHX Text
CALDER
AutoCAD SHX Text
HIGHWAY
AutoCAD SHX Text
COOINDA
AutoCAD SHX Text
PARK
AutoCAD SHX Text
BENDIGO
AutoCAD SHX Text
ROTARY
AutoCAD SHX Text
PARK
AutoCAD SHX Text
Gray
AutoCAD SHX Text
Street
AutoCAD SHX Text
(HIGH STREET)
AutoCAD SHX Text
GOLDEN SQUARE
AutoCAD SHX Text
SECONDARY COLLEGE
AutoCAD SHX Text
Waterson
AutoCAD SHX Text
Court
AutoCAD SHX Text
Close
Page 2: ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project Manager is to be notified seven days prior to the commencement of Works with a Pre-commencement

600Ø

RC

P

4

5

6

0

0

Ø

R

C

P

6

CITY OF GREATER BENDIGO

Survey

Scale:

Approved by

Design

Checked

GB4413

ALLINGHAM STREET

GOLDEN SQUARE

DRAINAGE RENEWAL

H. WHYTOCK

B. JANSSEN

L. OLIVER

N. SARTORI

08/10/18

12/03/19

-

2

PLAN VIEW 1

Revision :

File :

Original sheet size:

AMENDMENTS

Approved by DateRevision Description

DRAFT 1PRELIMINARY DESIGN

Plot Date:

BAYLEY JANSSENPlotted By:

26/03/2019

Sheet: Reference:

OF 5

12/03/19

12/03/19

A

GB4413.dwg

A3

- - - -

Upgrade existing SEP to EKI (COGB

SD590-A-D-J). Break into existing pit

and connect 600RCP. Block off existing

600RCP under road with concrete.

91-109 Allingham Street

Kangaroo F

lat - B

endig

o R

ail L

ine R

eserve

A

LLIN

G

H

A

M

S

TR

E

E

T

Excavate and remove

existing concrete drain.

Construct 900 x 900 SEP

(COGB SD590-A-C-G-R).

Construct 600 x 900 JP.

Construct letter box opening on

eastern side of pit to allow open

drain from property to enter.

(COGB SD590-A-C-L-R).

IMPORTANT!

The location of underground services have been derived from

available information, however accuracy cannot be guaranteed.

All existing service information should therefore be treated as

indicative only, and service locations must be arranged prior to

commencement of any excavation. The contractor will be held

responsible for any damage caused to underground services.

Block off pipe and fill

in hole

Fill in open drain with

compacted clean fill, finish

with 50mm topsoil and seed.

AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
DWY
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
DWY
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text
WATER 150%%CAC
AutoCAD SHX Text
Gas Transmission Line 200%%C
AutoCAD SHX Text
PAVED
AutoCAD SHX Text
FPATH
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text
SEWER 150%%CVC
AutoCAD SHX Text
TELSTRA 50%%CAC
Page 3: ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project Manager is to be notified seven days prior to the commencement of Works with a Pre-commencement

STN

RL 243.814

600Ø R

CP

6

0

0

Ø

R

C

P

1

2

3

CITY OF GREATER BENDIGO

Survey

Scale:

Approved by

Design

Checked

GB4413

ALLINGHAM STREET

GOLDEN SQUARE

DRAINAGE RENEWAL

H. WHYTOCK

B. JANSSEN

L. OLIVER

N. SARTORI

08/10/18

12/03/19

-

3

PLAN VIEW 2

Revision :

File :

Original sheet size:

AMENDMENTS

Approved by DateRevision Description

DRAFT 1PRELIMINARY DESIGN

Plot Date:

BAYLEY JANSSENPlotted By:

26/03/2019

Sheet: Reference:

OF 5

12/03/19

12/03/19

A

GB4413.dwg

A3

- - - -

Excavate and grade

invert to ensure flow

from outlet

Install SEP in existing

Kerb

Install EKI in existing

kerb.

Upgrade existing SEP to

EKI (COGB SD590-A-D-J)

Remove minor vegetation

and Install modified winged

endwall to accommodate

both outlets

Existing Gas High Pressure Transmission Line

Indicative Location only. Any works within the vicinity of a high

pressure transmission line will require Notification to SP AUSNET

Place 10m2 of 150mm

depth, 150mm rockspall

as shown.

91-109 Allingham Street

Kangaroo Flat - Bendigo Rail Line Reserve

ALLIN

GH

AM

ST

RE

ET

2-12 Hattam Street

IMPORTANT!

The location of underground services have been derived from

available information, however accuracy cannot be guaranteed.

All existing service information should therefore be treated as

indicative only, and service locations must be arranged prior to

commencement of any excavation. The contractor will be held

responsible for any damage caused to underground services.

AutoCAD SHX Text
Gas Transmission Line 200%%C
Page 4: ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project Manager is to be notified seven days prior to the commencement of Works with a Pre-commencement

CITY OF GREATER BENDIGO

Survey

Scale:

Approved by

Design

Checked

GB4413

ALLINGHAM STREET

GOLDEN SQUARE

DRAINAGE RENEWAL

H. WHYTOCK

B. JANSSEN

L. OLIVER

N. SARTORI

08/10/18

12/03/19

-

4

LONG SECTION

Revision :

File :

Original sheet size:

AMENDMENTS

Approved by DateRevision Description

DRAFT 1PRELIMINARY DESIGN

Plot Date:

BAYLEY JANSSENPlotted By:

26/03/2019

Sheet: Reference:

OF 5

12/03/19

12/03/19

A

GB4413.dwg

A3

- - - -

LEGEND

Backfill Under Naturestrip

COGB SD390

Backfill Under Existing Road

COGB SD392

0.00

31.90

31.90

243.11

243.37

243.20

243.93

243.47

243.93

0.97

1.17

24

2.5

0

24

2.7

6

1:125 0.8%

600Ø RCP CL2 RRJ

2.28

574

667

1 2

WIN

GW

AL

L S

D4

65

EK

I (L

)

K=

0.7

DRAINAGE LONGITUDINAL SECTION FOR LINE 1

SCALES: H 1:300 V 1:50 (A1)

CHAINAGE

HGL

EXISTING SURFACE

DESIGN SURFACE

DEPTH TO INVERT

INVERT LEVEL

DATUM RL 239

SLOPE/GRADE

PIPE DETAILS

VELOCITY (m/s)

CAPACITY (l/s)

ACTUAL FLOW (l/s)

STORM EVENT (20% AEP)

200Ø

IL 241.79

87.06

55.16

243.55

244.06

244.66

244.66

1.14

1.21

24

2.7

9

24

3.4

5

1:83 1.2%

600Ø RCP CL2 FJ

2.73

703

660

3

SE

P 9

00

x9

00

K=

0.2

Sew

er P

VC

150Ø

IL 241.97

153.70

66.64

244.11

244.89

245.42

245.53

1.18

1.14

24

3.4

8

24

4.2

8

1:83 1.2%

600Ø RCP CL2 FJ

2.74

703

676

4

SE

P 9

00

x9

00

K=

0.2

181.44

27.73

244.94

246.39

245.90

245.90

1.11

1.25

24

4.3

1

24

4.6

4

1:83 1.2%

600Ø RCP CL2 FJ

2.74

703

682

5

EK

I

K=

4.1

0.00

7.16

7.16

245.02

245.29

245.42

245.44

245.53

245.55

0.71

0.46

24

4.8

2

24

5.0

9

1:27 3.7%

200Ø HDPE CL7 RRJ

4 6

SE

P 9

00

x6

00

SE

P 9

00

x6

00

K=

5.0

DRAINAGE LONGITUDINAL SECTION FOR LINE 1

SCALES: H 1:100 V 1:50 (A1)

Telstra P

50Ø

IL 245.19

Water A

C 150Ø

IL 244.64

Sew

er P

VC

150Ø

IL 244.47

Telstra P

50Ø

IL 244.97

Page 5: ALLINGHAM STREET, GOLDEN SQUARE · and latest version of the IDM Standard Drawings. 3. The Project Manager is to be notified seven days prior to the commencement of Works with a Pre-commencement

PIT SETOUT

Point #

1

2

3

4

6

Pit #

1

2

3

4

6

Easting

254884.687

254895.546

254877.625

254859.793

254866.099

Northing

5925863.395

5925833.809

5925781.638

5925717.423

5925715.622

STATION DATA

Point #

901

902

903

Description

STN

PSM

PSM

Easting

254880.591

254814.465

254944.717

Northing

5925832.647

5925611.580

5925943.484

Level

243.814

248.574

245.870

CITY OF GREATER BENDIGO

Survey

Scale:

Approved by

Design

Checked

GB4413

ALLINGHAM STREET

GOLDEN SQUARE

DRAINAGE RENEWAL

H. WHYTOCK

B. JANSSEN

L. OLIVER

N. SARTORI

08/10/18

12/03/19

-

5

GENERAL NOTES

Revision :

File :

Original sheet size:

AMENDMENTS

Approved by DateRevision Description

DRAFT 1PRELIMINARY DESIGN

Plot Date:

BAYLEY JANSSENPlotted By:

26/03/2019

Sheet: Reference:

OF 5

12/03/19

12/03/19

A

GB4413.dwg

A3

- - - -

GENERAL CONSTRUCTION NOTES

1. All kerb, footpath and pram crossing constructions shall have bedding/boxing

inspected by the Superintendent's Representative prior to pouring of concrete.

2. If property stormwater outlets (not already identified on plan) are located during

construction, it is the Contractors responsibility to connect them into council

underground drainage or back of kerb (As per S.D. 45 & S.D. 47) to the approval of

the Superintendent's Representative.

3. Renewal of gas and water property service conduits to be 100mmØPVC (sewer

grade).

4. All sewer man-hole covers within the footpath alignment (wholly or partly) are to be

renewed & adjusted to design finished levels unless noted otherwise or directed by

the Superintendent's Representative.

5. All redundant footpath, kerb and road seal to be saw cut and removed from site.

6. All service pits are to be renewed and matched into design surface unless noted

otherwise noted or directed by the Superintendent's Representative.

7. All TGSI's are to be Black Fibre Reinforced Resin Polymer type manufactured by ESP

Aust. Or approved equivalent. TGSI's to be cast in place on new concrete works and

installed in accordance with AS1428, unless noted otherwise or directed by the

Superintendent's Representative.

ROAD CONSTRUCTION NOTES

1. All Works to be carried out in accordance with CoGB Standard Drawings,

Specifications, approved plans and to the satisfaction of the Superintendent's

Representative.

2. These notes also refer to the latest version of the Infrastructure Design Manual (IDM)

and latest version of the IDM Standard Drawings.

3. The Project Manager is to be notified seven days prior to the commencement of

Works with a Pre-commencement meeting to be held between CoGB, the Consultant

and the Contractor. A site management plan is to be submitted prior to the

commencement of Works and prior to the onsite Pre-commencement meeting.

4. Prior to commencement of the Works, the Contractor shall provide the following:

- Source of quarry material

- N.A.T.A. approved test results for the F.C.R that is to be used

- If the source of the quarry material is changed during the course of the Works, then

new test results shall be provided.

5. Prior to commencement of Works on site, the Contractor must ensure that all matters

relating to the Occupational Health and Safety Act 2004, have been and will be

complied with.

6. On the commencement of construction, the Contractor must comply with the

recommendation of the Environment Protection Authority publication "Construction

Techniques for Sediment Pollution Control". Appropriate siltation control is to be

maintained throughout the construction and maintenance period of the Works.

7. The disposal site for spoil storage, and truck removal route, is to be submitted in

writing to, and approved by the Superintendent's Representative prior to the

commencement of Works.

8. Where Works are in the vicinity of existing services, these services are to be located

and exposed prior to commencement of the work. Relevant authorities are to be

notified 7 days prior to the Works.

9. All dimensions are in metres unless noted otherwise.

10. All levels are to Australian Height Datum (AHD) unless noted otherwise.

11. All co-ordinates are to Map Grid of Australia (MGA) unless noted otherwise.

12. The Contractor must arrange the inspection of the Works with the Superintendent's

Representative as per the hold points in the Specifications, or as directed by the

Superintendent's Representative.

13. All redundant assets are to be removed and disposed off site unless noted otherwise.

14. All service conduit trenches under road pavements, under footpaths and under

swales are to be backfilled as per IDM SD310 unless noted otherwise. Compaction

standards noted in SD310 shall be achieved.

15. Blasting is not generally accepted.

16. All existing assets affected by the Works (i.e. signs, vehicle crossings, footpaths, kerb

and line marking) shall be reinstated by the Contractor before the completion of

Works, to the satisfaction of the Superintendent's Representative.

17. At the completion of all Works, all rubbish, debris and surplus spoil shall be removed

and the site shall be cleared to the satisfaction of the Superintendent's

Representative.

18. The Contractor is to obtain a Building Permit for any structures, fences and for any

retaining walls over 1.0m in height.

19. Any infrastructure damage incurred during the Defects Liability Period noted on the

contract is the responsibility of the Contractor and is to be reinstated to the

satisfaction of the Superintendent's Representative.

20. All disturbed areas (eg. nature strips, batters, allotments and reserves) are to be

reinstated to a clean, tidy condition, top dressed with 75mm min. depth approved top

soil, and seeded with a CoGB approved blend or unless otherwise noted. Soil &

seeded treated areas must be satisfactorily established prior to the end of the

Maintenance Period otherwise further treatment is required by the Contractor.

21. Any exposed aggregate concrete works are to be achieved by sandblasting only.

Washing aggregate off with water is not permitted.

22. The Contractor shall notify the public of any impending road closures by providing

sufficient signage 2 weeks prior to construction commencing.

IMPORTANT!

The location of underground services have been derived from

available information, however accuracy cannot be guaranteed.

All existing service information should therefore be treated as

indicative only, and service locations must be arranged prior to

commencement of any excavation. The contractor will be held

responsible for any damage caused to underground services.

DRAINAGE CONSTRUCTION NOTES

1. The Superintendent's Representative and Design Engineer must be notified if any any

modifications to drainage design are required due to unforseen circumstances identified

during works onsite.

2. Any property storm water pipes located during Works are to be plumbed to the

nearest pit. Where this is not practical, seek approval from the Superintendent's

Representative to connect stormwater into kerb or into the nearest storm water pipe.

3. All drainage pits are to be constructed as per the noted Standard Drawing.

4. Invert fall through pits is to be a min. of 30mm unless noted otherwise.

5. Concrete pit walls are to be sponge finished and floors are to be shaped for best

hydraulic efficiency unless noted otherwise.

6. Pit lids are to be installed flush with the surrounding surface unless noted otherwise.

7. Where concrete box culverts (CBC) or Crown Units are specified, they are to be

compliant to AS1597 and designed to the latest revision of the shear design standard.

8. Pipe extensions are to be constructed by removing the remaining stub of the existing

pipe to be extended, and then connecting the new pipe at the socket.

9. All pipe backfill is to be constructed as per the noted Standard Drawing.

10. The location of any saw cuts in asphalt are to be kept the minimum required trench

width until after the pipe is laid and backfilled up to 300mm from surface. At this point,

a further 150mm wide, 300mm deep section of asphalt/pavement is to be sawcut and

excavated so as to provide a longitudinal pavement join over the drainage trench.

This also should ensure a straight edge for re-asphalting. The top 300m depth of

backfill should then be constructed accordingly.

11. At the completion of the Works, pipes are to be visually inspected via inspection pits

to check for construction debris, including crushed rock, soil and concrete over spill.

Should a volume of debris be present enough to impede flows, pipe cleaning shall be

undertaken at the contractors expense.

12. Gas and water property services are generally not located during the design phase

and therefore have not been shown on plans. It is therefore the Contractors

responsibility to consider these services when excavating and adjust or realign

accordingingly whilst causing minimal disruption to property owners.

13. Gas and Water property services encountered during construction are to be altered

and reconnected to the appropriate standard and to the satisfaction of the

Superintendents Representative.

PAVEMENT NOTES

1. Construction of road pavements is to be in accordance with the requirements of

VicRoad's Standard Specifications for Roadworks (Section 304). Testing must be

carried out by a N.A.T.A. approved laboratory, or by calibrated nuclear densometer

test to the relevant Australian Standard.

2. Compaction tests are to be undertaken in the following locations:

- At

2

3

depth of the pavement

- At alternating sides of the road

- 1.0m in from the seal edge or lip of kerb

- At even spacings.

3. The number of compaction tests shall comply with the table below:

Location Number of Compaction tests

Court bowls 3

Intersections 2

Straights 1 per 500m2 (1/50m for 10.2m wide pvmt.)

4. Copies of the geotechnical results are to be submitted to the Superintendent's

Representative.

5. Sub-base and base materials are to be at 85% optimum moisture content (OMC)

during compaction, and maintained at 85% OMC until proof rolling.

6. Typical Compaction levels required (unless noted otherwise):

Subgrade: To be compacted to 100% standard dry density ratio.

Subbase: Flexible pavements shall be compacted in accordance with Scale C in

VicRoads table 304.082.

Compaction shall be to 98% of the maximum dry density ratio determined by the

modified compaction test.

Base: Flexible pavements shall be compacted in accordance with Scale C in VicRoads

table 304.082.

Compaction shall be to 100% of the maximum dry density ratio determined by the

modified compaction test.

7. Proof rolling of the Subgrade, Sub base and Base must be undertaken as per Section

12.7.15 of the IDM. Proof rolling will be at the expense of the contractor in accordance

with AS3798 and the requirements of section 173 and 204.12 of the VicRoad's

Specification. The Superintendent's Representative must be present during the proof

rolling. The Subgrade must not deflect more than 2mm vertically within 300mm of the

test roller in isolated locations.

8. Identification and treatment of soft areas during proof rolling shall be dealt with as per

Sections 12.7.13 and 12.7.14 of the IDM and as approved by the Superintendent's

Representative.

AutoCAD SHX Text
Pit Schedule - Allingham Street Drainage
AutoCAD SHX Text
Pit No.
AutoCAD SHX Text
Pit Type
AutoCAD SHX Text
Standard Drawing
AutoCAD SHX Text
Pit Width
AutoCAD SHX Text
Pit Length
AutoCAD SHX Text
Outlet Diameter
AutoCAD SHX Text
Outlet Invert RL
AutoCAD SHX Text
Inlet Diameter
AutoCAD SHX Text
Inlet Invert RL
AutoCAD SHX Text
Pit Depth
AutoCAD SHX Text
Pit Lid Level
AutoCAD SHX Text
Comment
AutoCAD SHX Text
(mm)
AutoCAD SHX Text
(mm)
AutoCAD SHX Text
(mm)
AutoCAD SHX Text
(m)
AutoCAD SHX Text
(mm)
AutoCAD SHX Text
(m)
AutoCAD SHX Text
(m)
AutoCAD SHX Text
(m)
AutoCAD SHX Text
1
AutoCAD SHX Text
WINGWALL
AutoCAD SHX Text
IDM SD465
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
600
AutoCAD SHX Text
242.500
AutoCAD SHX Text
0.968
AutoCAD SHX Text
243.468
AutoCAD SHX Text
2
AutoCAD SHX Text
EKI
AutoCAD SHX Text
COGB SD590-B-D-H
AutoCAD SHX Text
900
AutoCAD SHX Text
900
AutoCAD SHX Text
600
AutoCAD SHX Text
242.755
AutoCAD SHX Text
600
AutoCAD SHX Text
242.787
AutoCAD SHX Text
1.175
AutoCAD SHX Text
243.930
AutoCAD SHX Text
3
AutoCAD SHX Text
SEP
AutoCAD SHX Text
COGB SD590-B-D-G-R
AutoCAD SHX Text
900
AutoCAD SHX Text
900
AutoCAD SHX Text
600
AutoCAD SHX Text
243.449
AutoCAD SHX Text
600
AutoCAD SHX Text
243.479
AutoCAD SHX Text
1.191
AutoCAD SHX Text
244.640
AutoCAD SHX Text
4
AutoCAD SHX Text
SEP
AutoCAD SHX Text
COGB SD590-B-D-G-R
AutoCAD SHX Text
900
AutoCAD SHX Text
900
AutoCAD SHX Text
600
AutoCAD SHX Text
244.279
AutoCAD SHX Text
600
AutoCAD SHX Text
244.310
AutoCAD SHX Text
1.137
AutoCAD SHX Text
245.415
AutoCAD SHX Text
5
AutoCAD SHX Text
EKI
AutoCAD SHX Text
COGB SD590-A-D-J
AutoCAD SHX Text
600
AutoCAD SHX Text
900
AutoCAD SHX Text
600
AutoCAD SHX Text
244.643
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
1.237
AutoCAD SHX Text
245.880
AutoCAD SHX Text
Upgrade existing SEP to EKI
AutoCAD SHX Text
6
AutoCAD SHX Text
JP
AutoCAD SHX Text
COGB SD590-A-C-L-R
AutoCAD SHX Text
600
AutoCAD SHX Text
900
AutoCAD SHX Text
200
AutoCAD SHX Text
245.086
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
0.426
AutoCAD SHX Text
245.512
AutoCAD SHX Text
Cut open Back of pit to existing concrete drain