Alkco is a Philips group brand - Dickman Supplydownloads.dickmansupply.com/pdf/alkco/ERAcare.pdf ·...

12
Alkco is a Philips group brand

Transcript of Alkco is a Philips group brand - Dickman Supplydownloads.dickmansupply.com/pdf/alkco/ERAcare.pdf ·...

Alkco is a Philips group brand

is an integrated lighting solution for

the patient room environment. It fulfills the requirements

for Examination, Reading and Ambient lighting

whilealsosimplifyingtheday-to-dayeffortsofthehealthcare

professionalandfacilitymaintenancestaff.Everyaspectofthe

designisfocusedoneaseofuse.Patientsandstaffalikewant

thebestincareandERAcare™canhelpmeetthoseexpectations.

ERAcare ™

• ERAcare™ delivers the recommended illumination levels for patient reading.

• The patient’s visual comfort is enhanced by the soft, indirect ambient lighting.

• There are a variety of switching options for patient ease-of-use.

• Optical compartments are positioned to minimize glare.

• ERAcare™ has no moving parts that need to be flipped or rotated.

• From its soft form to its antimicrobial finish, ERAcare™ is designed to compliment infectious control efforts.

• The recommended illumination levels for examination are met.

• LED night/chart lights and switches are positioned at either end of the luminaire and can be controlled individually or together.

• The snap-in lenses provide tool-less lamp replacement.

• An optional bed shut-off switch minimizes the potential for luminaire damage from motorized patient beds.

• A removable ballast tray provides quick access to key electrical components.

c a r e f o r t h e

c a r e f o r t h e

c a r e f o r t h e

p a t i e n t

h e a l t h c a re p ro f e s s i o n a l

f a c i l i t y s t a f f

2 www.alkco.com

Function Recommended Levels1 ERAcare™ Levels

Exam

Reading

Ambient

1 Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities.2 Achieved with utilizing the exam and reading optical compartments.3 Achieved with utilizing the exam optical compartments only.

I n t e g r a t e d O p t i c a l S o l u t i o n s

Illuminationofthepatientbedforexamination

IlluminationofboththehorizontalandangledreadingplanesGeneralroomillumination

112Avg.Footcandles2

80Avg.Footcandles3

65Avg.Footcandles(horizontal)54Avg.Footcandles(angled)12Avg.Footcandles

50-100Avg.Footcandles

20-50Avg.Footcandles

5-10Avg.Footcandles

ERAcare™ utilizes four separate optical compartments to

providethreekeyilluminationrequirementsforthepatient

room–Exam,ReadingandAmbient.Thesevaried functions

are integrated into a compact cross-section and can be

activated without the need to flip, rotate or mechanically

move any part of the luminaire. The needs of the patient

andhealthcarestaffareaflipoftheswitchaway.

Ambient

Reading

Front Exam Rear Exam

Lamp CompartmentsA

A

B

BC

C

D

D

LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20

3www.alkco.com

P ro d u c t D e t a i l s

• Thediecastendcapsandextrudedaluminum housingprovidesdurability.

• Internallinearprismshelpmaintainasmooth exteriorsurfacethatiseasytowipedown.

• ERAcare’sdualexamopticalcompartments promotebetteruniformityacrosstheentire patientbedsurface.

• Multipleswitchingoptionsareavailabletomeet theneedsoftheinstallation.

• The removable socket covers conceal the lamp socket and promote a uniform appearance of the illuminated lens.

• The positive snap-in lenses provide tool-less lamp replacement.

• A removable ballast tray provides convenient access to key electrical components.

• ERAcare™isavailableinfourstandardfinishes– allwithanantimicrobialadditivetoinhibitthe growthofmicrobesforthelifeoftheproduct.

1

5

1

2

2

3

3

3

4

4

5

• Thesmallcross-section helpsERAcare™blend intothepatientroom environment.

• Thesoftcurvedform eliminatessharpcorners, simplifiescleaningand reducesvisualsize.

• Noflatsurfacestosititemson.

• TheBedShut-offSwitchoptionminimizesthe potentialforluminairedamagefrommotorized patientbedsbydisconnectingpowertothebed whenERAcare™ismoved.

• Asanoption,asetofintegratedLEDchart/night lightsarelocatedateitherendoftheluminaire. Healthcarestaffcanconvenientlyoperatethese lowlevellightsfrombothsidesofthepatientbed.

• ERAcare™meetsthemoststringentillumination recommendationsforexamandreadingfunctions. Seechartonpage2.

ERAcare™canbecomplimentedwithAlkco’s WayGlo™LEDNightLights.Formoreinformation onWayGlo™orotherAlkco®Healthcaresolutions, gotowww.alkco.comorcontactyourlocalAlkco® representative.

Soft White Taupe Aluminum Almond WG1H WG1V WG2H WG2V

8-15/16”(227.3mm)

5-1/2”(139.7mm)

A m b i e n t

(1)54WT5HOFluorescent*4450lumensperlamp*Testingambientlamponly.

ReportNo.: ITL60756ModelNo.: ECT5HOEfficiency: 80.9%

LEGEND: 0-deg: 45-deg:

90-deg:

1800

1200

600

180˚ 165˚ 150˚

90˚

105˚

120˚

135˚

Illumination values calculated at 30” AFF.

ERAcare™ Candela Distribution

Patient Room View

Room Parameters

RoomSize: 12’x12’CeilingHt.: 8’-6”

LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20

Ambient Illumination Level

Recommended Level* (Avg. Footcandles) 5-10

* RecommendationsarefromANSI/IESNARP-29-06,AnIESNARecommended Practice,LightingforHospitalsandHealthCareFacilities

** Achievedutilizingtheambientopticalcompartmentwith(1)F54T5HOlamp.

Visitwww.alkco.comforcompletePhotometricData

ERAcare™

(Avg. Footcandles) 12**

11.0 13.1 15.4 17.5 19.2 20.2 20.2 19.2 17.5 15.4 13.1 11.0

12.1 14.4 16.9 19.3 21.2 22.3 22.3 21.2 19.3 16.9 14.5 12.1

12.4 14.8 17.2 19.5 21.4 22.5 22.5 21.4 19.5 17.2 14.8 12.4

12.0 14.2 16.4 18.5 20.1 21.1 21.0 20.1 18.5 16.4 14.2 12.0

11.2 13.1 14.9 16.6 18.0 18.7 18.7 18.0 16.6 14.9 13.0 11.1

10.0 11.6 13.1 14.4 15.5 16.0 16.0 15.5 14.4 13.1 11.6 10.0

8.8 10.1 11.2 12.2 13.0 13.4 13.4 13.0 12.2 11.2 10.0 8.8

7.6 8.6 9.5 10.3 10.8 11.1 11.1 10.8 10.3 9.5 8.6 7.6

6.6 7.4 8.0 8.6 9.0 9.3 9.2 9.0 8.6 8.0 7.3 6.6

5.7 6.3 6.8 7.3 7.6 7.8 7.8 7.6 7.3 6.8 6.3 5.7

5.0 5.5 5.9 6.3 6.5 6.6 6.6 6.5 6.2 5.9 5.5 4.9

4.4 4.8 5.2 5.5 5.7 5.8 5.8 5.7 5.5 5.2 4.8 4.4

4 www.alkco.com

Room Parameters

Room Size: 12’ x 12’Ceiling Ht.: 8’-6”

Luminaire Mtg. Ht.: 6’ AFFRoom Reflectances: 80/50/20

Exam Illumination Level (Patient bed positioned 30” AFF)

Recommended Level* (Avg. Footcandles) 50-100

* Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities** Achieved utilizing the exam and reading optical compartments with (3) F54 T5HO lamps*** Achieved utilizing the exam optical compartments with (2) F54 T5HO lamps

Visit www.alkco.com for complete Photometric Data

ERAcare™

(Avg. Footcandles) 112** 80***

E x a m

(3) 54W T5HO Fluorescent*4450 lumens per lamp* Testing 3 lamps (exam and reading).

Report No.: ITL60757Model No.: ECT5HOEfficiency: 64.1%

LEGEND: 0-deg: 45-deg:

90-deg:

1300

2600

3900

0˚ 15˚ 30˚

45˚

60˚

75˚

90˚

ERAcare™ Candela Distribution

Detail of Exam SurfacePatient Room View

Luminaire Mtg. Ht.: 6’ AFFRoom Reflectances: 80/50/20

5 www.alkco.com

156183

194

155183

187219

231

186219

168131

97.770.5

51.438.6

30.1

194148

10876.6

54.840.6

31.3

204154

11278.8

56.141.3

31.7

168131

97.670.4

51.338.6

30.0

194148

10876.5

54.840.6

31.7

Exam Surface

Room Parameters

RoomSize: 12’x12’CeilingHt.: 8’-6”

Detail of Horizontal Reading Surface

LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20

Reading Illumination Level (Horizontal Plane)

Recommended Level* (Avg. Footcandles) 20-50

* RecommendationsarefromANSI/IESNARP-29-06,AnIESNARecommended Practice,LightingforHospitalsandHealthCareFacilities

** Achievedutilizingthereadingopticalcompartmentwith(1)F54T5HOlamp.

Visitwww.alkco.comforcompletePhotometricData

ERAcare™

(Avg. Footcandles) 65**

H o r i z o n t a l R e a d i n g

(1)54WT5HOFluorescent*4450lumensperlamp*Testingreadinglamponly.

ReportNo.: ITL60755ModelNo.: ECT5HOEfficiency: 74.8%

LEGEND: 0-deg: 45-deg:

90-deg:

1300

2600

3900

0˚ 15˚ 30˚

45˚

60˚

75˚

90˚

ERAcare™ Candela Distribution

Patient Room View

Horizontal ReadingSurface

6 www.alkco.com

73.986.6

91.3

74.386.9

59.668.8

72.4

59.969.0

43.248.5

50.5

43.448.6

Detail of Angled Reading Surface

Room Parameters

RoomSize: 12’x12’CeilingHt.: 8’-6”

LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20

Reading Illumination Level (45° Plane, 47” AFF)

Recommended Level* (Avg. Footcandles) 20-50

* RecommendationsarefromANSI/IESNARP-29-06,AnIESNARecommended Practice,LightingforHospitalsandHealthCareFacilities

** Achievedutilizingthereadingopticalcompartmentwith(1)F54T5HOlamp.

Visitwww.alkco.comforcompletePhotometricData

ERAcare™

(Avg. Footcandles) 54**

Patient Room View

A n g l e d R e a d i n g

ERAcare™ Candela Distribution(1)54WT5HOFluorescent*4450lumensperlamp*Testingreadinglamponly.

ReportNo.: ITL60755ModelNo.: ECT5HOEfficiency: 74.8%

LEGEND: 0-deg: 45-deg:

90-deg:

1300

2600

3900

0˚ 15˚ 30˚

45˚

60˚

75˚

90˚

49.96

58.31

53.4152.88

59.0351.25

55.87

53.16

48.54

53.96

7 www.alkco.com

Angled Reading Surface

Luminaire Construction• Theexteriorhousingconsistsofanextrudedaluminumbody anddiecastendcaps.

• Thebackplateandballasttrayareformedfrom18gauge galvanizedsteel.

Finish• ERAcare™canbespecifiedinoneoffourstandard polyesterpowder-coatpaintfinishes–white,taupe, aluminumoralmond.

• Customfinishesareavailableuponrequest.Acolorchip, tomatch,needstobeprovidedbythecustomer.

•Allstandardfinisheshaveanantimicrobialadditivetoinhibit thegrowthofmicrobes.

Reflectors• ERAcare™hasfourseparateanduniquereflectorsroll-formed fromspecularaluminum.

Lens• Thetopambientlens(topsurface)andthefrontexamlensare bothextrudedacrylicwithDRadditiveforflexibilityoverthe lifeoftheproduct.Thebottomexam/readinglensisextruded fromacrylic.

• Internallinearprismshelpmaintainasmoothexteriorsurface.

• Removableextrudedaluminumsocketcoversareprovided attheendsofeachapertureopeningtoconcealthelamp socketandtocreateamoreuniformappearanceacross theilluminatedlenssurface.

Lamps• ERAcare™canbespecifiedwitheitherF54T5HO,F28T5 orF32T8linearfluorescentlamps.

• PhilipsAlto®,lowmercurylampsaresuppliedwiththe luminaire.3500Kisthestandardcolortemperaturebut alternativecolortemperaturescanbespecified.

Switching• Thestandardswitchingconfigurationisanon/offpullcordfor thereadingcompartmentwiththeambientandexamcompart- mentscontrolledfromaremotewallswitch(byothers).

• Anoptional4-positionpullcordswitch(HDS)forsequential controloftheambientandreadingcompartmentsisavailable. Theexamfunctioniscontrolledfromaremotewallswitch.

• Pullswitchesaresuppliedwithaplasticpullcordthatislatex- free,stain-resistant,andeasytocleanwithstandarddisinfectant.

• Anoptionallowvoltagerelay(LVC),thatiscompatiblewith industrystandardbedcontrolsystems(byothers),canbefield wiredforeitherseparateorsequentialswitchingoftheambient andreadingcompartments.

• ERAcare™canalsobespecified“lessswitch”(LS)withremote switching(byothers)controllingallfunctions.

Electrical• Electronichighpowerfactorballasts,ratedfor120and277 volts,areused.347voltballastsavailableforT8lampsonly.

• BallastsarethermallyprotectedandhaveaClass“A”soundrating.

• T5andT5HOballastshaveend-of-lifeprotection.

List ing• ULandCULListed.ERAcare™isalsoIBEWlabeled.

• Agion®antimicrobialhasbeenlistedwiththeU.S.Food andDrugAdministration(FDA),certifiedbytheNational SanitationFoundation(NSF)andregisteredwiththeU.S. EnvironmentalProtectionAgency(EPA).

Instal lation• Thebackplateismountedovertheelectricaljunctionbox ortoelectricalwiringwhipandsecuredtothewallstructure.

• Thehousinghooksontothebackplateandissecuredwith twoscrews.

• Lampreplacementisperformedbyremovingthelensandone socketcover.

Warranty• Limitedlifetimewarrantyonmaterialsandworkmanship. Standardmanufacturerswarrantyappliesonlampsandballasts.

8 www.alkco.com

ECO-FRIENDLY

ECO-FRIENDLY

ECO-FRIENDLY

ECO-FRIENDLY

P ro d u c t S p e c i f i c a t i o n s

ECT5HO

ECT5

ECT8

48-15/16”(1243.1mm)

48-15/16”(1243.1mm)

50-7/8”(1292.22mm)

8-15/16”(227.3mm)

24” (609.6mm)

38” (965.2mm)

16”(406.4mm)

5-1/2”(139.7mm)

5-1/2”(139.7mm)

Side View

Front View

Back View

Cross SectionA. Ambient lamp compartmentB. Reading lamp compartmentC. Exam lamp compartmentD. Rear Exam lamp compartment

ECT5HO (4) F54 T5HO (Med. Bipin)

ECT5 (4) F28 T5 (Med. Bipin)

ECT8 (4) F32 T8 (Med. Bipin)

1202773471

SWH Soft WhiteTPE TaupeAL AluminumALM AlmondCC2 Custom Color

HDS 4-position pull cord switch for sequential control of ambient and reading compartments (120v only)LVC3,4 Low voltage controllerLS Less switchEM13 Emergency ballastNL3 LED night/chart light w/dual 3-position rocker switches (120v and 277v)NL-W3 LED night/chart light (remote switch by others), (120v and 277v) SBF Slow blow fuseBSS3 Bed shut-off switch (120v and 277v)PC Replacement 6’ plastic pull cord (non-latex)

NOM.LENGTH Model Number Voltage Finish

(standard color is SWH)Options

Sample Catalog No: ECT5HO - 277 - SWH - HDS - NL

4’

1 347v available for ECT8 only. 2 Customer to provide color chip to match.3 Not available for 347v applications.4 Not available with EM1 option.

A

BD

C

9 www.alkco.com

D i m e n s i o n a l D a t a

O rd e r i n g I n f o r m a t i o n

Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled “Contains Mercury” and/or with the symbol “Hg”. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org

Hg

Alkco is a Philips group brand

11500 Melrose AvenueFranklin Park, IL 60131Phone (847) 451-0700Fax (847) 451-7512www.alkco.com

© 2008 Philips Group. All rights reserved. Certain products illustrated in this catalog may be protected by applicable patents and patents pending. Alkcowill aggressively defend all of its intellectual property. We reserve the right to change details of design, materials and finishes.

Printed in the U.S.A. 10/08