Alarm Monitoring and Control System - Praxis … · Alarm Monitoring and Control System Mega-Guard...

4
Alarm Monitoring and Control System Mega-Guard AMCS: Alarm, Monitoring and Control Extension Alarm System Easy and reliable Workstation Solid state disks only Based on Windows 7 embedded Language option: Chinese, Japanese Distributed Processing Units Low power consumption Power supply voltage: 19~32Vdc Suitable for any size of vessel From 24 to 24.000 IO Points Class type approved (UMS) YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION

Transcript of Alarm Monitoring and Control System - Praxis … · Alarm Monitoring and Control System Mega-Guard...

Page 1: Alarm Monitoring and Control System - Praxis … · Alarm Monitoring and Control System Mega-Guard AMCS: Alarm, Monitoring and Control Extension Alarm System Easy and reliable Workstation

Alarm Monitoring and Control System

Mega-Guard AMCS:

Alarm, Monitoring and Control

Extension Alarm System

Easy and reliable Workstation

Solid state disks only

Based on Windows 7 embedded

Language option: Chinese, Japanese

Distributed Processing Units

Low power consumption

Power supply voltage: 19~32Vdc

Suitable for any size of vessel

From 24 to 24.000 IO Points

Class type approved (UMS)

YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION

Page 2: Alarm Monitoring and Control System - Praxis … · Alarm Monitoring and Control System Mega-Guard AMCS: Alarm, Monitoring and Control Extension Alarm System Easy and reliable Workstation

The Mega-Guard Alarm Monitoring andControl System (AMCS) is the perfect automationsolution for medium to large size vessels.It can be used as a stand-alone AlarmMonitoring and Control System or theMega-Guard can be extended with powermanagement, cargo control, propulsioncontrol, integrated navigation and dynamicpositioning functions.

The Mega-Guard Alarm Monitoring and ControlSystem is the most reliable and field provensystem on the market because of the followingfacts:

Features

An Operator Workstation consists of a TFT Colour Graphic Screen, Operator Keyboard with Trackball, Marine PersonalComputer and optional Printer. The Operator Workstation provides a reliable and user-friendly operator interface to ensuresafe operation. The Operator Workstations are connected to each other via the redundant Ethernet link based uponUTP cabling. Two Operator Workstations, called the main server and the back-up server, are communicating via theredundant Ethernet link with the Control Processor with I/O Modules (Distributed Processing Units) and to the ExtensionAlarm System. This ensures a full redundant lay-out. Client Operator Workstations communicate with either the main server orback-up server Operator Workstation via the redundant Ethernet link. The on duty selection and engineer calling functions arefully redundant as upon failure of an Operator Workstation, the extension alarm system functions are automatically transferredto a back-up Operator Workstation. Various language options are available including Chinese, Japanese and others.

Operator Workstations

Operator Workstations built-up with MarinePersonal Computers under Windows 7embedded operating system and redundantEthernet link. Solid state disk is appliedinstead of hard disk. Main and back-upWorkstation to further ensure safety andreliability.D istributed Processing Units built-up withControl Processors equipped withI/O Modules and redundant Ethernet link.Each I/O Module has its own isolatedsensor supply and earth fault detector.Extension Alarm System is built-up withEAS Operator Panels equipped with agraphic LCD display and 12 illuminatedpushbuttons with redundant Ethernet link.

Whole system inter-connected by redundant Ethernet link. Cabling with star or ring topology or a combination ofstar and ring topology. W hole system operating directly on 19~32VDC power supply and all components have low power consumption.U ninterruptable Power Supply providing fail safe 24VDC output. P rogramming in accordance with international PLC programming standard IEC61131-3 (ST).T ype approved by all major classification societies.

2

A l a rm Mo n i t o r i n g a n d C o n t ro l Sys te m

Opera

tor

Work

statio

n w

ith C

olo

ur

Gra

phic

Scr

een a

nd

use

r-fr

iendly

Opera

tor

Keyb

oard

with

Tra

ckball

Page 3: Alarm Monitoring and Control System - Praxis … · Alarm Monitoring and Control System Mega-Guard AMCS: Alarm, Monitoring and Control Extension Alarm System Easy and reliable Workstation

Control Processors with I/O Modules (also called DPU) are mounted on a DIN rail; close to sensors andactuators to minimize cabling. The Control Processor is connected to the redundant Ethernet link forcommunication with the main and back-up server Operator Workstations and for communication withother Control Processors. Each I/O channel on an I/O Module has a LED indication and a channelidentification text window. This can be used for back-up and local read-out of alarms and status.Each I/O Module is equipped with an isolated sensor supply in order to feed sensors. In addition,the I/O Module contains an earth fault detector. A Control Processor with I/O Modules fully executescontrol, alarm and monitoring functions even when no Operator Workstation is connected. Programmingof control functions is done via the programming language PAL1131 which is in accordance withinternational PLC standard IEC61131-3 (ST). Sensors and actuators are directly wired to the detachableterminal strips on the I/O Modules. Serial interface links are connected to Serial link I/O Modules.

The Extension Alarm System is a highly reliable engineer callingsystem, which extends the Mega-Guard AMCS for unmannedmachinery space operation. On duty selection and engineercalling functions are executed on a dedicated mimic on theOperator Workstation.

A Control Processor supports up to 8 I/O Modules and up to 4 Serial link I/O Modules to external devices.Serial interface links will be connected via the Modbus RTU or NMEA protocol (other protocols optional).The Control Processors with I/O Modules and Serial link I/O Modules are installed in DPU cabinets orinside a console on a DPU DIN rail.

The dedicated mimic display on the Operator Workstationcontains the following fields:

On duty selectionA ttended / unattended (manned / unmanned) engine roomE ngineer callingP atrol timer / engineer safety system (dead man timer)

EAS Operator Panels are installed in bridge and accommodationareas. The EAS Operator Panels are equipped with the following:

Graphic LCD displaydisplaying individual alarms. On duty lamp. 8 x group alarm lamp & buzzer.

Fire alarm lamp with buzzer. Call ECR / bridge pushbuttons / lamps. Accept / stop horn pushbutton. Dimming pushbuttons (Arrow left / right).

Distributed Processing Units

3

The Alarm Monitoring and Control System executes the following functions:

Alarm and monitoring Exhaust gas monitoring Tank gauging

Valve control and monitoring Temperature control (PID)etc.

Master and stand-by pump control Motor and pump starter Compressor control

The following I/O Modules are available:

24 channel Mixed I/O Module with4 Analog Outputs and 20 configurableinputs and/or outputs (AI, AO, DI, DO, PI).31 channel PMS I/O Module.

Extension Alarm System

36 channel Digital Input I/O Module.18 channel Digital Input and18 channel Relay Output I/O Module.24 channel Analog Input I/O Module.

AM

CS

Co

ntro

l Pro

ce

sso

r with

2 I/O

Mo

du

les a

nd 1

Se

rial lin

k I/O M

od

ule

EA

S O

pe

rato

r P

an

el

I /O Mo d u l e s & Ex te n s i o n A l a rm Sys te m

SYSTEM ON FAULT

STOPHORN

ACK.

GROUP 8NON

VITAL

GROUP 4SAFETYSYSTEM

GROUP 7STEERING

GEAR

GROUP 3AUX.

MACHINERY

GROUP 6

ELECTRIC

GROUP 2GENERATOR

ENGINE

GROUP 5TANK &BILGE

GROUP 1MAIN

ENGINE

CALLBRIDGE

CALLECR

FIREALARM

ONDUTY

2

A

B

C

14

1B

C

13

3

A

B

C

15

4

A

B

C

16

5

A

B

C

17

6

A

B

C

18

7

A

B

C

19

8

A

B

C

20

9

A

B

C

21

10

A

B

C

22

11

A

B

C

23

12

A

B

C

24

PART No. X102

No. 1 G/ELO IN PRESSURE

No. 1 ALTERNATORWINDING

W TEMPERATURE

No. 1 ALTERNATORWINDING

V TEMPERATURE

No. 1 ALTERNATORWINDING

U TEMPERATURE

A

B

C

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

No. 1 G/ELO IN TEMPERATURE

No. 1 G/EH.T.F.W. OUTLETTEMPERATURE

No. 1 G/EF.O. INLETPRESSURE

No. 2 G/ELO IN PRESSURE

No. 2 ALTERNATORWINDING

W TEMPERATURE

No. 2 ALTERNATORWINDING

V TEMPERATURE

No. 2 ALTERNATORWINDING

U TEMPERATURE

No. 2 G/ELO IN TEMPERATURE

No. 2 G/EH.T.F.W. OUTLETTEMPERATURE

No. 2 G/EF.O. INLETPRESSURE

No. 1 H.F.O.SERVICE TANKTEMPERATURE

No. 2 H.F.O.SERVICE TANKTEMPERATURE

No. 1 H.F.O.SETTL. TANK

TEMPERATURE

No. 2 H.F.O.SETTL. TANK

TEMPERATURE

No. 1 H.F.O.TANK (P)

TEMPERATURE

No. 1 H.F.O.TANK (S)

TEMPERATURE

No. 2 H.F.O.TANK (P)

TEMPERATURE

No. 2 H.F.O.TANK (S)

TEMPERATURE

PART No. X103

1A

B

2A

B

3A

B

4A

B

5A

B

6A

B

7A

B

8A

B

9A

B

19A

B

20A

B

21A

B

22A

B

23A

B

24A

B

25A

B

26A

B

27A

B

10A

B

11A

B

12A

B

13

A

B

14A

B

15A

B

16A

B

17A

B

18A

B

28A

B

29A

B

30A

B

31A

B

32A

B

33A

B

34A

B

35A

B

36A

B

L.O. AUTOFILTER

DIFF. PRESSURE

EMERG. FIRE PUMPABNORMAL

CASCADE & INSPECTANK LEVEL

M/E SAFETY AIRNOT VENTED

SLUDGE TANKHIGH LEVEL

EMERG. FIREPUMP ROOM

BILGE HIGH LEVEL

M/E CYL.LUBRICATOR A

LEVEL LOW

M/E CYL.LUBRICATOR A

NON FLOW

M/E CYL.LUBRICATOR B

LEVEL LOW

M/E CYL.LUBRICATOR B

NON FLOW

M/E F.O.LEAKAGE

HIGH LEVEL

M/E EXH. V/VSPRING AIRPRESSURE

M/E SAFETY AIRINLET PRESSURE

M/E OIL MISTDENSITY CRANKCASE

M/E OIL MISTDETECT FAIL

M/E SCAV. AIRW. MIST CATCHER

HIGH LEVEL

M/E No.1PISTON COOL OIL

OUTLET FLOW

M/E No.2PISTON COOL OIL

OUTLET FLOW

M/E No.3PISTON COOL OIL

OUTLET FLOW

M/E No.4PISTON COOL OIL

OUTLET FLOW

M/E No.5PISTON COOL OIL

OUTLET FLOW

M/E No.6PISTON COOL OIL

OUTLET FLOW

OILY BILGEW. SEPARATOR

OILY CONTENT HIGH

OILYW. SEPARATOR

OILY CONTENT HIGH

B.W.BENEATH M/E

F.O. DRAIN TANKHIGH LEVEL

WASTE OIL TANKHIGH LEVEL

M/E LO CIRC. TANKLOW LEVEL

STERN LODRAIN TANKHIGH LEVEL

STERN LOFORE SEAL TANK

LOW LEVEL

STERN LOAFT SEAL ANK

HIGH LEVEL

STERN LOAFT SEAL ANK

LOW LEVEL

PIPE TUNNEL BILGEHIGH LEVEL

COFFERDAM BILGEHIGH LEVEL

M/E AXIALVIBRATION

M/E AXIALVABRATION

POWER FAILURE

ETHMAIN

ETHB/U

r+

r-

c

no

1

2

3

4

5

6

7

8

24V

0V

c

nc

ADDRESS

RESISTOR

G.E.A. OUTPUT

STOP HORN INPUT

ATTENDED INPUT

TIMER KEY. SW. ON/OFF

UNATTENDED OUTPUT

ATTENDED OUTPUT

TIMER OUTPUT

TIMER ON/OFF

GND

RESET INPUT

G.E.A. INPUT

TIMER EXPIRED

GND

UNATTENDED INPUT

SYSTEM ON

FAILURE

9

16

10

11

12

13

14

15

di

do

di

di

gnd

do

do

di

19

17

18

do

di

gnd

24

20

21

do

di

di

22

23

gnd

gnd

HORN

XP011

ICMS

BARCODE LABEL

PRODUCT LABEL

3

5

7

1

4

6

2

COM

Tx-/B

Rx-

RxD

Tx+/A

Rx+

TxD

ON

LYTX

OFF

TX

E120

OFF

RX

E120

OFF

AU

TOTX

ON

TX

E120

ON

RX

E120

ON

2400

1200

9600

4800

115k

219

k2

SW2

SW1

USE

DN

OT

BAU

D

ON

ON

ON

OFF

OFFON

OFF

OFF

No3SW

No4SW

No5SWSYSTEM ON RS422

PROTOCOL BAUDRATE

Rx ACTIVITY Tx ACTIVITY

BARCODE LABEL PRODUCT LABEL

XL011 VDRINTERFACE

Page 4: Alarm Monitoring and Control System - Praxis … · Alarm Monitoring and Control System Mega-Guard AMCS: Alarm, Monitoring and Control Extension Alarm System Easy and reliable Workstation

Mega-Guard Alarm Monitoring and Control SystemE

.C.R

.A

CC

.

Ch

ief

Cab

in 1

Cab

in 2

Cab

in 3

Mess

Bri

dg

e

OperatorWorkstation

En

gin

e R

oo

m

OperatorWorkstation

OperatorWorkstation

PanelOperatorEAS

Ethernet

Ethernet

Ethernet

SYSTEM ON FAULT

STOPHORN

ACK.

AUTOMATION TECHNOLOGY

GROUP 8NON

VITAL

GROUP 4SAFETYSYSTEM

GROUP 7STEERING

GEAR

GROUP 3AUX.

MACHINERY

GROUP 6

ELECTRIC

GROUP 2GENERATOR

ENGINE

GROUP 5TANK &BILGE

GROUP 1MAIN

ENGINE

CALLBRIDGE

CALLECR

FIREALARM

ONDUTY

PanelOperatorEAS

SYSTEM ON FAULT

STOPHORN

ACK.

AUTOMATION TECHNOLOGY

GROUP 8NON

VITAL

GROUP 4SAFETYSYSTEM

GROUP 7STEERING

GEAR

GROUP 3AUX.

MACHINERY

GROUP 6

ELECTRIC

GROUP 2GENERATOR

ENGINE

GROUP 5TANK &BILGE

GROUP 1MAIN

ENGINE

CALLBRIDGE

CALLECR

FIREALARM

ONDUTY

PanelOperatorEAS

SYSTEM ON FAULT

STOPHORN

ACK.

AUTOMATION TECHNOLOGY

GROUP 8NON

VITAL

GROUP 4SAFETYSYSTEM

GROUP 7STEERING

GEAR

GROUP 3AUX.

MACHINERY

GROUP 6

ELECTRIC

GROUP 2GENERATOR

ENGINE

GROUP 5TANK &BILGE

GROUP 1MAIN

ENGINE

CALLBRIDGE

CALLECR

FIREALARM

ONDUTY

PanelOperatorEAS

SYSTEM ON FAULT

STOPHORN

ACK.

AUTOMATION TECHNOLOGY

GROUP 8NON

VITAL

GROUP 4SAFETYSYSTEM

GROUP 7STEERING

GEAR

GROUP 3AUX.

MACHINERY

GROUP 6

ELECTRIC

GROUP 2GENERATOR

ENGINE

GROUP 5TANK &BILGE

GROUP 1MAIN

ENGINE

CALLBRIDGE

CALLECR

FIREALARM

ONDUTY

PanelOperatorEAS

SYSTEM ON FAULT

STOPHORN

ACK.

AUTOMATION TECHNOLOGY

GROUP 8NON

VITAL

GROUP 4SAFETYSYSTEM

GROUP 7STEERING

GEAR

GROUP 3AUX.

MACHINERY

GROUP 6

ELECTRIC

GROUP 2GENERATOR

ENGINE

GROUP 5TANK &BILGE

GROUP 1MAIN

ENGINE

CALLBRIDGE

CALLECR

FIREALARM

ONDUTY

OperatorWorkstation

OperatorWorkstation

A B A BA B A B A B

Main Hub

Ethernet Ethernet Ethernet Ethernet

Ethernet Ethernet

A B

A B A B A B A B

Backup Hub

A B A B A B A B

EthernetEthernetEthernetEthernet

Ethernet

I / O

I/O Cabinet

DistributedProcessing

Unit

I / O

I/O Cabinet

DistributedProcessing

Unit

I / O

I/O Cabinet

DistributedProcessing

Unit

I / O

I/O Cabinet

DistributedProcessing

Unit

YOUR GUIDE TO SHIP AUTOMATION AND NAVIGATION

Praxis Automation China

Praxis Automation Korea

Praxis Automation Singapore

Praxis Automation India

Your representative:Branch offices: Head office:

Praxis Automation Technology B.V.Zijldijk 24A, 2352 AB Leiderdorp, The Netherlands

+31 (0)71 5255 353 +31 (0)71 5224 [email protected]

www.praxis-automation.com

Mega-Guard Ship Automation and Navigation System

DynamicPositioning System

PropulsionControl System

EconometerSystem

PowerManagement System

Valve Control andMonitoring System

HeadingControl System

BNWASWatch Alarm System

FireAlarm System

Alarm andMonitoring System

Navigation Light andWindow Wiper System

IntegratedBridge System

Alarm Monitoringand Control System