AL-KO Prospekt AT4 Engl

download AL-KO Prospekt AT4 Engl

of 5

Transcript of AL-KO Prospekt AT4 Engl

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    1/8

    AIR-HANDLING-UNIT AT4 –OPTIMISED BY FUNCTIONALITYAND QUALITY

    AIR-HANDLING-UNITS

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    2/82

    AT4 – optimised by functionality and quality

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    3/83

    Convincing advantages

    I variable and optimized adjustment

    for all system-specific applications

    I high product quality using the very

    latest production technology

    I customer-oriented process control

    guarantees maximum reliability of

    deliveries

    I designing and calculating supported

    by Klim@Soft®, the professional

    design tool for planers and customers

    I unit version according to VDI 6022

    (Standard of German Association of

    Engineers)

    Design with experience

    construction features

    I maximum corrosion protection by

    galvanized and additional powder-

    coated casing panels

    I high heat and noise insulation due

    to 47 mm panel thickness

    I noise and heat insulation material

    made of mineral wool; building

    material class A1; non-flammable

    pursuant to DIN 4102

    I patented thermal isolation between

    the panel shells

    I minimized thermal transmittance

    due to optimized casing covers

    I unit construction dismantled

    I optimal adjustment to building

    situation due to a variable pitch

    dimension of 76.5 mm

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    4/84

    Internal walls hygienically smooth

    AT4 – with this we convince

    Patented thermal isolation

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    5/85

    Complies with all national and European standards

    Efficiency and economy

    I reduced energy consumption and

    minimized internal pressure losses

    by optimized air-flow through the air-

    treatment components

    I selection of fans adapted to the

    operating point

    I use of all conventional heat

    recoverysystems; layout to the

    actual application

    I “Life-Cycle-Costs”-optimized

     air-handling-units

    Top quality for all applications

    I suitable for interior

    and exterior installation

    I hygienic finish

    I integrated cooling units

    I various material versions

    designed to be dismantled

    I large and special units

    I DCS (Desiccant Cooling System)

     2 0 0 7 - 2 0

     1 0

    CONFORMITY 

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    6/8

    AT4 – quick selection

    6

    12 x 08

    08 x 08

    12 x 08

    16 x 08

    12 x 12

    16 x 12

    20 x 12

    24 x 12

    16 x 16

    20 x 16

    24 x 16

    32 x 16

    20 x 20

    24 x 20

    41 x 20

    24 x 24

    28 x 24

    32 x 24

    28 x 28

    32 x 28

    32 x 32

    41 x 28

    41 x 32

    49 x 32

    0 10 000 20 000 30 000 40 000 50 000 60 000 70 000 80 000 90 000 100 000 110 000

    0 2.78 5.56 8.33 11.1 13.89 16.67 19.44 22.22 25 27.78 30.56

    Air-volume-flow in m3 /h

    Air-volume-flow in m3 /s

    Velocity in blower stream in m /sec.,

    cross-section of unit with clearance

    2 2.5 3 3.5

    Speed range

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    7/87

      2 300 – 5 300 12 x 06 995 536 918 459

      2 000 – 4 700 08 x 08 689 689 612 612

      3 000 – 7 100 12 x 08 995 689 918 612

      4 000 – 9 400 16 x 08 1 301 689 1 224 612

      4 600 – 10 600 12 x 12 995 995 918 918

      6 100 – 14 200 16 x 12 1 301 995 1 224 918

      7 600 – 17 700 20 x 12 1 607 995 1 530 918

      9 100 – 21 200 24 x 12 1 913 995 1 836 918

      8 100 – 18 900 16 x 16 1 301 1 301 1 224 1 224

     10 100 – 23 600 20 x 16 1 607 1 301 1 530 1 224

     12 100 – 28 300 24 x 16 1 913 1 301 1 836 1 224

     16 200 – 37 800 32 x 16 2 525 1 301 2 448 1 224

     12 600 – 29 500 20 x 20 1 607 1 607 1 530 1 530

     15 200 – 35 400 24 x 20 1 913 1 607 1 836 1 530

     25 900 – 60 500 41 x 20 3 213 1 607 3 137 1 530

     18 200 – 42 500 24 x 24 1 913 1 913 1 836 1 836

     21 200 – 49 600 28 x 24 2 219 1 913 2 142 1 836

     24 300 – 56 600 32 x 24 2 525 1 913 2 448 1 836

     24 800 – 57 800 28 x 28 2 219 2 219 2 142 2 142

     28 300 – 66 100 32 x 28 2 525 2 219 2 448 2 142

     32 400 – 75 500 32 x 32 2 525 2 525 2 448 2 448

     36 300 – 84 700 41 x 28 3 213 2 219 3 137 2 142

     41 500 – 96 700 41 x 32 3 213 2 525 3 137 2 448

     49 600 – 115 600 49 x 32 3 825 2 525 3 749 2 448

      Width (mm) *Height (mm) Width (mm) *Height (mm)

    Air-flow Unit size Outer dimensions Inner dimensions

    m3 /h

    Subject to dimensional and design changes. Further sizes on demand.

    *Height without installation frame, installation frame = + 110 mm

  • 8/9/2019 AL-KO Prospekt AT4 Engl

    8/8

    AL-KO THERM GmbH

    Hauptstraße 248-250

    89343 Jet tingen-Scheppach

    Phone (+49) 8225 / 39- 269

    Fax (+49) 8225 / 39- 271

    E-mail [email protected]