AIRPORT PARKWAY PRIVATE

4
AIRPORT PARKWAY PRIVATE AIRPORT PARKWAY PRIVATE OVERHEAD SIGN WITH CONCRETE FOOTINGS BH-1 BH-1A BH-2 BH-3 BH-4 BH-5 BH-6 BH-8 BH-9 BH-10 BH-7 HOTEL DROP OFF PHASE 1 LEVEL 1 FFE = 120.200 LEVEL 0 FFE = 116.200 PHASE 2 (FUTURE) B B B B 271 274 269 245 238 237 239 272 273 270 236 241 240 2 263 262 250 249 258 257 251 235 248 256 252 253 254 255 244 234 246 233 243 242 247 226 227 228 229 230 231 232 3 213 210 212 211 3 1 2 4 5 6 216 217 218 215 214 219 220 221 223 222 224 7 8 12 11 10 8 9 225 13 19 18 15 14 261 260 259 16 17 16 266 265 267 268 RED OSIER DOGWOOD, FLOWERING CRAB APPLE (AND ALL OTHER SPECIES) NOTED ON THE "C.12 TRANSPORT CANADA, SAFETY AND SECURITY, AERODROME SAFETY BRANCH, C.4 ORNAMENTAL TREES AND SHRUBS ATTRACTIVE TO BIRDS LIST," TO BE REMOVED PROPOSED alt HOTEL PHASE 1 THE UNDERGROUND FEATURES AND INFORMATION THAT APPEAR ON THE DRAWINGS WERE OBTAINED FROM THE PUBLIC UTILITY COMPANIES AND/OR FROM THE CITY EACH RESPECTIVELY. ALL INFORMATION UNDER THE LEGEND 'EXISTING' IS FOR INFORMATION ONLY. COMPLETE OR EXACT LOCATION AND ELEVATION OF UNDERGROUND SERVICES ARE NOT GUARANTEED. CERTAIN UNDERGROUND FEATURES ON PRIVATE PROPERTY ARE NOT SHOWN ON THE CURRENT DRAWING. ANYONE WHO PROCEEDS WITH EXCAVATION WORK SHALL VERIFY THE EXACT LOCATION OF ALL UNDERGROUND FEATURES, BY EXPLORATORY EXCAVATIONS, AND SHALL ASSUME FULL RESPONSIBILITY IF THERE IS ANY DAMAGE THAT OCCURS DURING WORK. THE CONTRACTOR WILL HAVE THE RESPONSIBILITY AND THE OBLIGATION TO VALIDATE, BY EXPLORATORY EXCAVATION, THE SIZE OF THE PUBLIC UTILITIES UNDERGROUND SERVICES AND TO WARN THE ENGINEER OF ANY CONFLICT WITH THE PROJECTED WORK. 240 Catherine St., Suite 110 OTTAWA (ON), K2P 2G8 T. 613.860.2462 660 Ave. Royale, Québec (QC), G1E 1Y7 T. 418.666.0009 815, Boul. Lebourgneuf, Bur. 406 Québec (QC), G2J 0C1 T. 418.871.8103 STAMP NOT FOR CONSTRUCTION DESIGN INTENT ONLY DRAWING PRINTING / REVISIONS FILE # NOTES CONSULTANTS PAGE CLIENT PROJECT | PAPER FORMAT : ISO A1 | The contractor must verify all dimensions and communicate any discrepancies with the architect before carrying out the work. This document remains the property of « LEMAYMICHAUD Architecture Design » and should be used only for the specific use which it is intended. SCALE: DATE PRINTED: FILE: C10\OTT_Projects\A\A000874_Ottawa Airport - ALT-Hotel\400\460\L001.dwg STRUCTURE MECHANICAL / ELECTRICAL CIVIL / LANDSCAPE / INFRASTRUCTURE 2019-08-23 ALT Ottawa Airport 1085 Airport Parkway Private Ottawa Ontario K1V 9B4 TREE INVENTORY, REMOVALS AND PRESERVATION PLAN L001 DRAW BY: L. May APPROVED BY: L. Cullen DESIGNED BY: CHECKED BY: 38118L AS INDICATED Scale: 1 : 300 L001 1 TREE INVENTORY, REMOVALS AND PRESERVATION PLAN N N NO. DATE DESCRIPTION A 2019-01-21 ISSUED FOR 90% REVIEW B 2019-03-25 ISSUED FOR SITE PLAN APPLICATION 0m 5m 10m 15m 20m 25m EDGE PAVING BORDER CENTRE LINE LAMP EXISTING TREES WITH TREE INVENTORY NUMBER WOODED AREAS WITH TREE INVENTORY NUMBER TOP OF SLOPE BOTTOM OF SLOPE LIMIT OF WORK LEGEND EXISTING PROPOSED ELEVATION 113.00 SEE CHART TREE PROTECTION FENCE SEE DETAIL PROPOSED TREES (SEE PLANTING DETAIL) C 2019-07-18 ISSUED FOR SITE PLAN APPLICATION R1 D 2019-09-20 ISSUED FOR SITE PLAN APPROVAL R2 19/09/2019

Transcript of AIRPORT PARKWAY PRIVATE

A

I

R

P

O

R

T

P

A

R

K

W

A

Y

P

R

I

V

A

T

E

AIRPORT PARKWAY PRIVATE

OVERHEAD SIGN WITH

CONCRETE FOOTINGS

BH-1

BH-1A

BH-2

BH-3

BH-4

BH-5

BH-6

BH-8

BH-9

BH-10

BH-7

HOTEL DROP OFF

PHASE 1

LEVEL 1 FFE = 120.200

LEVEL 0 FFE = 116.200

P

H

A

S

E

2

(

F

U

T

U

R

E

)

B

B

B

B

271

274

269

245

238

237

239

272

273

270

236

241

240

264

263

262

250

249

258

257251

235

248

256

252

253

254

255

244

234

246

233

243

242

247

226

227

228

229

230

231

232

3

213

210212

211

3

1

2

4

5

6

216

217

218

215

214

219

220

221

223

222

224

7

8

12

11

10

8

9

225

13

19

18

15

14

261

260

259

16

17

16

266

265

267

268

RED OSIER DOGWOOD, FLOWERING

CRAB APPLE (AND ALL OTHER

SPECIES) NOTED ON THE "C.12

TRANSPORT CANADA, SAFETY AND

SECURITY, AERODROME SAFETY

BRANCH, C.4 ORNAMENTAL TREES

AND SHRUBS ATTRACTIVE TO BIRDS

LIST," TO BE REMOVED

PROPOSED

alt HOTEL

PHASE 1

THE UNDERGROUND FEATURES AND INFORMATION THAT

APPEAR ON THE DRAWINGS WERE OBTAINED FROM THE PUBLIC

UTILITY COMPANIES AND/OR FROM THE CITY EACH

RESPECTIVELY.

ALL INFORMATION UNDER THE LEGEND 'EXISTING' IS FOR

INFORMATION ONLY. COMPLETE OR EXACT LOCATION AND

ELEVATION OF UNDERGROUND SERVICES ARE NOT

GUARANTEED.

CERTAIN UNDERGROUND FEATURES ON PRIVATE PROPERTY

ARE NOT SHOWN ON THE CURRENT DRAWING.

ANYONE WHO PROCEEDS WITH EXCAVATION WORK SHALL

VERIFY THE EXACT LOCATION OF ALL UNDERGROUND

FEATURES, BY EXPLORATORY EXCAVATIONS, AND SHALL

ASSUME FULL RESPONSIBILITY IF THERE IS ANY DAMAGE THAT

OCCURS DURING WORK.

THE CONTRACTOR WILL HAVE THE RESPONSIBILITY AND THE

OBLIGATION TO VALIDATE, BY EXPLORATORY EXCAVATION, THE

SIZE OF THE PUBLIC UTILITIES UNDERGROUND SERVICES AND

TO WARN THE ENGINEER OF ANY CONFLICT WITH THE

PROJECTED WORK.

240 Catherine St., Suite 110OTTAWA (ON), K2P 2G8T. 613.860.2462

660 Ave. Royale,Québec (QC), G1E 1Y7T. 418.666.0009

815, Boul. Lebourgneuf, Bur. 406Québec (QC), G2J 0C1T. 418.871.8103

STAM

P

NOT FOR CONSTRUCTION

DESIGN INTENT ONLY

DRAW

INGPR

INTING

/ REV

ISION

SFIL

E #NO

TES

CONS

ULTA

NTS

PAGE

CLIEN

TPR

OJEC

T

| PAPER FORMAT : ISO A1 |

The contractor must verify all dimensions and communicate anydiscrepancies with the architect before carrying out the work.

This document remains the property of «LEMAYMICHAUD ArchitectureDesign » and should be used only for the specific use which it isintended.

SCALE:

DATE PRINTED: FILE: C10\OTT_Projects\A\A000874_Ottawa Airport - ALT-Hotel\400\460\L001.dwg

STRUCTURE

MECHANICAL / ELECTRICAL

CIVIL / LANDSCAPE / INFRASTRUCTURE

2019-08-23

ALT Ottawa Airport1085 Airport Parkway PrivateOttawaOntarioK1V 9B4

TREE INVENTORY,REMOVALS ANDPRESERVATION PLAN

L001

DRAW BY: L. May APPROVED BY: L. Cullen

DESIGNED BY: CHECKED BY:

38118L

AS INDICATED

Scale: 1 : 300L001

1

TREE INVENTORY, REMOVALS AND PRESERVATION PLAN

N

N

NO. DATE DESCRIPTION

A 2019-01-21 ISSUED FOR 90% REVIEWB 2019-03-25 ISSUED FOR SITE PLAN APPLICATION

0m 5m 10m 15m 20m 25m

EDGE PAVING

BORDER

CENTRE LINE

LAMP

EXISTING TREES WITH TREE INVENTORY NUMBER

WOODED AREAS WITH TREE INVENTORY NUMBER

TOP OF SLOPE

BOTTOM OF SLOPE

LIMIT OF WORK

LEGEND

EXISTING PROPOSED

ELEVATION

113.00

SEE CHART

TREE PROTECTION FENCE

SEE DETAIL

PROPOSED TREES

(SEE PLANTING DETAIL)

C 2019-07-18 ISSUED FOR SITE PLAN APPLICATION R1D 2019-09-20 ISSUED FOR SITE PLAN APPROVAL R2

19/09/2019

40mm X 40mm X 5mm T-BAR AT 1500mm o.c.

UNDISTURBED NATIVE SOIL

VARIABLE

15

00

TREE PROTECTION DETAIL

N.T.S.

10

00

DR

IP

LIN

E

DR

IP

LIN

E

FASTENED TO EACH T-BAR WITH WIRE TIES

100mm X 50mm X 1500mm 14 GAUGE UTILITY FENCE

DO NOT CUT OR DAMAGE LEADER

PRUNE ONLY INJURED OR DEAD BRANCHES. RETAIN NATURAL SHAPE

CUTTING OF ROOTS ARUND EXISTING TREES TO BE

PRESERVED WILL NOT BE PERMITTED WITHOUT

APPROVAL FROM THE SITE INSPECTOR

NO CONSTRUCTION ACTIVITY, MATERIAL STORAGE,

GRADE CHANGE, SURFACE TREATMENT OR

EXCAVATIONS OF ANY KIND SHALL BE PERMITTED

INSIDE OF TREE PROTECTION ZONE

EXISTING GRADE TO BE RETAINED

ALL DIMENSIONS ARE IN MILLIMETERS

1

240 Catherine St., Suite 110OTTAWA (ON), K2P 2G8T. 613.860.2462

660 Ave. Royale,Québec (QC), G1E 1Y7T. 418.666.0009

815, Boul. Lebourgneuf, Bur. 406Québec (QC), G2J 0C1T. 418.871.8103

STAM

P

NOT FOR CONSTRUCTION

DESIGN INTENT ONLY

DRAW

INGPR

INTING

/ REV

ISION

SFIL

E #NO

TES

CONS

ULTA

NTS

PAGE

CLIEN

TPR

OJEC

T

| PAPER FORMAT : ISO A1 |

The contractor must verify all dimensions and communicate anydiscrepancies with the architect before carrying out the work.

This document remains the property of «LEMAYMICHAUD ArchitectureDesign » and should be used only for the specific use which it isintended.

SCALE:

DATE PRINTED: FILE: C10\OTT_Projects\A\A000874_Ottawa Airport - ALT-Hotel\400\460\L001.dwg

STRUCTURE

MECHANICAL / ELECTRICAL

CIVIL / LANDSCAPE / INFRASTRUCTURE

2019-08-23

ALT Ottawa Airport1085 Airport Parkway PrivateOttawaOntarioK1V 9B4

TREE INVENTORY REPORT ANDTREE PROTECTION FENCE DETAIL

L002

DRAW BY: L. May APPROVED BY: L. Cullen

DESIGNED BY: CHECKED BY:

38118L

AS INDICATED

NO. DATE DESCRIPTION

A 2019-01-21 ISSUED FOR 90% REVIEWB 2019-03-25 ISSUED FOR SITE PLAN APPLICATIONC 2019-07-18 ISSUED FOR SITE PLAN APPLICATION R1D 2019-09-20 ISSUED FOR SITE PLAN APPROVAL R2

19/09/2019

AIRPORT PARKWAY PRIVATE

BH-4

15

Hr

60

Sh

175

Sh

APPROXIMATE LOCATION OF

ALT HOTEL PYLON (BY OTHERS)

60

Hr

40

Hh

50

La

75

Hh

90

Sa

50

Sh

0

+

0

4

0

0

+

0

5

0

0

+

1

0

0

0

+

1

5

0

0

+

1

6

8

BH-1

BH-1A

BH-2

BH-3

BH-4

BH-5

BH-6

BH-8

BH-9

BH-10

BH-7

SEE ENLARGEMENT OF BIO SWALE

4

Gb

35

Ra

2

Af

76

Ra

3

Pp

3

Pa

1

Gt

5

Ll

3

Ov

3

Po

4

Ll

3

Gb

4

Pg

3

Qr

RELOCATED LIGHT

STANDARD

4

Gt

6

Po

PROPOSED

alt HOTEL

PHASE 2

PROPOSED

alt HOTEL

PHASE 1

BENCH: EQUIPARC MODEL EP 1900 (WITH

BACKREST), & MODEL EP 1901 (NO BACKREST),

WITH CONCRETE BASES OR APPROVED EQUAL

BIKE RACKS : EQUIPARC MODEL EP 5790OR

APPROVED EQUAL

5

Af

3

Ov

3

Ov

6

Qr

3

Qr

2

Gt

2

Gt

1

Qrf

1

Qrf

1

Qrf

20

H2

20

H3

37

H1

27

H3

65

H2

RELOCATED LIGHT

STANDARD

115

Js

2

Gb

PAVERS

ENLARGEMENT: 1:150

THE UNDERGROUND FEATURES AND INFORMATION THAT

APPEAR ON THE DRAWINGS WERE OBTAINED FROM THE PUBLIC

UTILITY COMPANIES AND/OR FROM THE CITY EACH

RESPECTIVELY.

ALL INFORMATION UNDER THE LEGEND 'EXISTING' IS FOR

INFORMATION ONLY. COMPLETE OR EXACT LOCATION AND

ELEVATION OF UNDERGROUND SERVICES ARE NOT

GUARANTEED.

CERTAIN UNDERGROUND FEATURES ON PRIVATE PROPERTY

ARE NOT SHOWN ON THE CURRENT DRAWING.

ANYONE WHO PROCEEDS WITH EXCAVATION WORK SHALL

VERIFY THE EXACT LOCATION OF ALL UNDERGROUND

FEATURES, BY EXPLORATORY EXCAVATIONS, AND SHALL

ASSUME FULL RESPONSIBILITY IF THERE IS ANY DAMAGE THAT

OCCURS DURING WORK.

THE CONTRACTOR WILL HAVE THE RESPONSIBILITY AND THE

OBLIGATION TO VALIDATE, BY EXPLORATORY EXCAVATION, THE

SIZE OF THE PUBLIC UTILITIES UNDERGROUND SERVICES AND

TO WARN THE ENGINEER OF ANY CONFLICT WITH THE

PROJECTED WORK.

240 Catherine St., Suite 110OTTAWA (ON), K2P 2G8T. 613.860.2462

660 Ave. Royale,Québec (QC), G1E 1Y7T. 418.666.0009

815, Boul. Lebourgneuf, Bur. 406Québec (QC), G2J 0C1T. 418.871.8103

STAM

P

NOT FOR CONSTRUCTION

DESIGN INTENT ONLY

DRAW

INGPR

INTING

/ REV

ISION

SFIL

E #NO

TES

CONS

ULTA

NTS

PAGE

CLIEN

TPR

OJEC

T

| PAPER FORMAT : ISO A1 |

The contractor must verify all dimensions and communicate anydiscrepancies with the architect before carrying out the work.

This document remains the property of «LEMAYMICHAUD ArchitectureDesign » and should be used only for the specific use which it isintended.

SCALE:

DATE PRINTED: FILE: C10\OTT_Projects\A\A000874_Ottawa Airport - ALT-Hotel\400\460\L001.dwg

STRUCTURE

MECHANICAL / ELECTRICAL

CIVIL / LANDSCAPE / INFRASTRUCTURE

2019-08-23

ALT Ottawa Airport1085 Airport Parkway PrivateOttawaOntarioK1V 9B4

LANDSCAPE PLAN

L003

DRAW BY: L. May APPROVED BY: L. Cullen

DESIGNED BY: P. Brocks CHECKED BY: P. Brocks

38118L

AS INDICATED

Scale: 1 : 300L003

1

LANDSCAPE PLAN

N

N

NO. DATE DESCRIPTION

A 2019-01-21 ISSUED FOR 90% REVIEWB 2019-03-25 ISSUED FOR SITE PLAN APPLICATION

0m 5m 10m 15m 20m 25m

EDGE PAVING

BORDER

CENTRE LINE

LAMP

EXISTING TREES WITH TREE INVENTORY NUMBER

WOODED AREAS WITH TREE INVENTORY NUMBER

TOP OF SLOPE

BOTTOM OF SLOPE

LIMIT OF WORK

LEGEND

EXISTING PROPOSED

ELEVATION

113.00

SEE CHART

TREE PROTECTION FENCE

SEE DETAIL

PROPOSED TREES

(SEE PLANTING DETAIL)

CONTRACTOR SHALL ENSURE THAT THE REQUIREMENTS OF HYDRO

OTTAWA'S FREE PUBLICATION 'TREE PLANTING ADVICE' ARE MET.

https://static.hydroottawa.com/documents/publications/safety/tree_planting_advice-EN.pdf

C 2019-07-19 ISSUED FOR SITE PLAN APPLICATION R1D 2019-09-20 ISSUED FOR SITE PLAN APPROVAL R2

19/09/2019

CUT AND REMOVE ALL TWINE, ROPE, WIRE AND BURLAP FROM TOP

HALF OF ROOTBALL

BASE OF TREE TO BE FLUSH WITH GRADE OR 75mm ABOVE

FINISHED GRADE IN POORLY DRAINED SOILS. TRUNK FLARE MUST

BE VISIBLE,DO NOT COVER TOP OF ROOTBALL WITH SOIL

CONSTRUCT A 100mm HIGH TOPSOIL SAUCER AROUND TREE BASE.

PLACE ROOTBALL ON UNEXCAVATED OR THOROUGHLY

COMPACTED SOIL

UNDISTURBED NATIVE SOIL

MARK NORTH SIDE OF TREE IN NURSERY; ROTATE TREE TO FACE

NORTH ON SITE UNLESS DIRECTED OTHERWISE BY CONTRACT

ADMINISTRATOR

100mm LAYER OF SPECIFIED MULCH, KEPT BACK 50mm FROM TRUNK.

REMOVE ALL FOREIGN MATERIAL FROM EXISTING SOIL. BACKFILL WITH

EXISTING SOIL MIXED 2:1 WITH TOPSOIL. FIRMLY COMPACT OR WATER SOIL

IN 150mm LAYERS TO ELIMINATE AIR POCKETS AND PREVENT SETTLEMENT

THOROUGHLY SOAK PIT WITH WATER IN NEXT TO LAST LAYER

VARIABLE 300 MIN

13

00

600

DECIDUOUS TREE PLANTING DETAIL

N.T.S.

DO NOT CUT OR DAMAGE LEADER

PRUNE ONLY INJURED OR DEAD BRANCHES. RETAIN NATURAL SHAPE

REMOVE TRUNK WRAP AFTER PLANTING

01

NOTE: TREE STAKING SHALL NOT BE INSTALLED UNLESS REQUIRED BY

THE SITE CONDITIONS OR DIRECTED BY THE CONTRACT ADMINISTRATOR

STEEL 'T' BAR (40x40x5x2400) OR ACCEPTABLE WOODEN SUBSTITUTE.

PLACE STAKE ON SIDE OF PREVAILING WIND. TREES UNDER 70mm CALIPER

REQUIRE 2 STAKES AND TREES OVER 70mm REQUIRE 3 STAKES. ENSURE

STAKES ARE NOT DRIVEN THROUGH ROOTBALL.

WHITE CORRUGATED PVC PIPE RODENT GUARD 50mm BELOW GRADE

TO 500mm ABOVE GRADE

TREE STAKING NOT TO BE INSTALLED UNLESS REQUIRED BY THE SITE

CONDITIONS OR DIRECTED BY THE CONTRACT ADMINISTRATOR

STEEL 'T' BAR (40x40x5x2400) OR ACCEPTABLE WOODEN SUBSTITUTE.

PLACE STAKE ON SIDE OF PREVAILING WIND. TREES UNDER 70mm CALIPER

REQUIRE 2 STAKES AND TREES OVER 70mm CALIPER REQUIRE 3 STAKES.

ENSURE STAKES ARE NOT DRIVEN THROUGH ROOTBALL.

CUT AND REMOVE ALL TWINE, ROPE, WIRE AND BURLAP FROM TOP

HALF OF ROOTBALL

BASE OF TREE TO BE FLUSH WITH GRADE OR 75mm ABOVE

FINISHED GRADE IN POORLY DRAINED SOILS. TRUNK FLARE MUST

BE VISIBLE,DO NOT COVER TOP OF ROOTBALL WITH SOIL

CONSTRUCT A 100mm HIGH TOPSOIL SAUCER AROUND TREE BASE.

PLACE ROOTBALL ON UNEXCAVATED OR THOROUGHLY

COMPACTED SOIL

UNDISTURBED NATIVE SOIL

MARK NORTH SIDE OF TREE IN NURSERY; ROTATE TREE TO FACE

NORTH ON SITE UNLESS DIRECTED OTHERWISE BY CONTRACT

ADMINISTRATOR

100mm LAYER OF SPECIFIED MULCH, KEPT BACK 50mm FROM TRUNK.

REMOVE ALL FOREIGN MATERIAL FROM EXISTING SOIL. BACKFILL WITH

EXISTING SOIL MIXED 2:1 WITH TOPSOIL. FIRMLY COMPACT OR WATER SOIL

IN 150mm LAYERS TO ELIMINATE AIR POCKETS AND PREVENT SETTLEMENT

THOROUGHLY SOAK PIT WITH WATER IN NEXT TO LAST LAYER

VARIABLE 300 MIN

1300

600

CONIFEROUS TREE PLANTING DETAIL

N.T.S.

DO NOT CUT OR DAMAGE LEADER

PRUNE ONLY INJURED OR DEAD BRANCHES. RETAIN NATURAL SHAPE

REMOVE TRUNK WRAP AFTER PLANTING

02

SHRUB PLANTING DETAIL

N.T.S.

SPACING AS PER PLAN

100mm LAYER OF SHREDDED BARK MULCH

CONSTRUCT TOPSOIL SAUCER AROUND SHRUBS

IF SUBGRADE IS DISTURBED, FIRMLY COMPACT BACKFILLED SOIL

TO ELIMINATE AIR POCKETS AND SETTLEMENT

SCARIFY SURFACE PRIOR TO PLANTING

UNDISTURBED EARTH

50

PRUNE ONLY DEAD OR INJURED BRANCHES, RETAIN NATURAL SHAPE

CUT AND REMOVE ALL TWINE, ROPE AND BURLAP FROM TOP

HALF OF ROOTBALL. REMOVE PLASTIC CONTAINERS. CUT SEVERAL

SLITS INTO ORGANIC CONTAINER TO FACILITATE ROOT PENETRATION

MAINTAIN ORIGINAL GRADE AT SHRUB BASE OR SET

SLIGHTLY HIGHER TO ALLOW FOR SETTLEMENT

PLANT GROUPS OF SHRUBS IN CONTINUOUS TOPSOIL BEDS

WITH CONTINUOUS MULCH

FIRMLY COMPACT SOIL MEDIUM,SEE BIO-SWALE MEDIA COMPOSITION.

THOROUGHLY SOAK PIT WITH WATER IN NEXT TO LAST LAYER

REMOVE ALL FOREIGN MATERIAL FROM EXISTING SOIL

BACKFILL WITH EXISTING SOIL MIXED 2:1 WITH TOPSOIL

03

NOTE:

ALL DISTURBED AREAS TO RECEIVE 150mm SCREENED TOPSOIL AND SEED.

SEED MIX:

ECO-LAWN BY OSC OR APPROVED EQUAL APPLICATION RATE 180 KG / HA

MATERIAL SPECIFICATION QUAINTLY

FILTER MEDIA FILTER MEDIA SOIL MIXTURE TO CONTAIN: RECOMMENDED DEPTH IS

COMPOSITION - 85 TO 88% SAND BEWTEEN 1.0 AND 1.25m

- 8 TO 12% SOIL FINES

- 3 TO 5% ORGANIC MATTER (LEAF COMPOST)

OTHER CRITERIA:

- PHOSPHORUS SOIL TEST INDEX (P-INDEX) VALUE

BETWEEN 10 TO 30 ppm

- CATIONIC EXCHANGE CAPACITY (CEC) GREATER

THAN 10 meq/100g

- FREE OF STONES, STUMPS, ROOTS AND OTHER

LARGE DEBRIS

- pH BETWEEN 5.5 TO 7.5

- INFILTRATION RATE GREATER THAN 25 mm/hr

240 Catherine St., Suite 110OTTAWA (ON), K2P 2G8T. 613.860.2462

660 Ave. Royale,Québec (QC), G1E 1Y7T. 418.666.0009

815, Boul. Lebourgneuf, Bur. 406Québec (QC), G2J 0C1T. 418.871.8103

STAM

P

NOT FOR CONSTRUCTION

DESIGN INTENT ONLY

DRAW

INGPR

INTING

/ REV

ISION

SFIL

E #NO

TES

CONS

ULTA

NTS

PAGE

CLIEN

TPR

OJEC

T

| PAPER FORMAT : ISO A1 |

The contractor must verify all dimensions and communicate anydiscrepancies with the architect before carrying out the work.

This document remains the property of «LEMAYMICHAUD ArchitectureDesign » and should be used only for the specific use which it isintended.

SCALE:

DATE PRINTED: FILE: C10\OTT_Projects\A\A000874_Ottawa Airport - ALT-Hotel\400\460\L001.dwg

STRUCTURE

MECHANICAL / ELECTRICAL

CIVIL / LANDSCAPE / INFRASTRUCTURE

2019-08-23

ALT Ottawa Airport1085 Airport Parkway PrivateOttawaOntarioK1V 9B4

LANDSCAPE DETAILS

L004

DRAW BY: L. May APPROVED BY: L. Cullen

DESIGNED BY: P. Brocks CHECKED BY: P. Brocks

38118L

AS INDICATED

NO. DATE DESCRIPTION

A 2019-01-21 ISSUED FOR 90% REVIEWB 2019-03-25 ISSUED FOR SITE PLAN APPLICATION

EP 5790: BIKE RACK - COLLECTION MTL

BIKE RACKS

EQUIPARC1001 JAMES-BRODIE

ST-JEAN-SUR-RICHELIEU, QC J2X 0C1TOLL FREE: 1-800-363-9264

PHONE: (450) 346-1882FAX: (866) 346-2538

www.equiparc.com

CADdetails.com19/09/2019L001

PROTECTED BY COPYRIGHT ©2019 CADDETAILS.COM LTD.REVISION DATE

FRONT ELEVATIONSIDE ELEVATION

TOP VIEW

32 1/

2" (8

26 M

M)5 1

/2"(1

40 M

M)

15"(381 MM)

NOTES:1. PLEASE CONTACT MANUFACTURER FOR FINISH AND COVERING OPTIONS.2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.3. DO NOT SCALE DRAWING.4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN

PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND

APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.6. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 2896-086.

NOTES:1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS.3. DO NOT SCALE DRAWING.

EP 1900: BENCH WITH BACKREST - COLLECTION PROMENADE

BENCHES

REFERENCE NUMBER 2896-016.4. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info

EQUIPARC1001 JAMES-BRODIE

ST-JEAN-SUR-RICHELIEU, QC J2X 0C1TOLL FREE: 1-800-363-9264

PHONE: (450) 346-1882FAX: (866) 346-2538

www.equiparc.com

CADdetails.com19/09/2019L001

PROTECTED BY COPYRIGHT ©2019 CADDETAILS.COM LTD.REVISION DATE

TOP VIEW

FRONT ELEVATION

59"(1499mm)

23 1/

4"(5

88mm

)17

3/4"

(452

mm)

SIDE ELEVATION

NOTES:1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS.3. DO NOT SCALE DRAWING.

EP 1901: BENCH WITHOUT BACKREST-COLLECTION PROMENADE

BENCHES

REFERENCE NUMBER 2896-017.4. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info

EQUIPARC1001 JAMES-BRODIE

ST-JEAN-SUR-RICHELIEU, QC J2X 0C1TOLL FREE: 1-800-363-9264

PHONE: (450) 346-1882FAX: (866) 346-2538

www.equiparc.com

CADdetails.com19/09/2019L001

PROTECTED BY COPYRIGHT ©2019 CADDETAILS.COM LTD.REVISION DATE

TOP VIEW

FRONT ELEVATION

59"(1499mm)

17"

(432

mm)

2"(5

0mm)

SIDE ELEVATION

C 2019-07-18 ISSUED FOR SITE PLAN APPLICATION R1D 2019-09-20 ISSUED FOR SITE PLAN APPROVAL R2

19/09/2019