Page 1: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|1

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

WWW.FRIZONIA.COM

• AIR TERMINAL UNITS ▪ TSC

▪TSCR

REV0109

DIFF

USIO

N E

LEM

ENTS

RIGHT TO ALTERATIONS RESERVED

Page 2: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|2

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

DIFF

USIO

N E

LEM

ENTS

TSC air distribution terminals have been appositely designed for ceiling installation on board of ships and permit, by means of manual control, the regulation of the air quantity in the ambient.

AIR TERMINALUNITS - TSC

TSC

Page 3: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|3

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

TSC terminal unit is composed of:.

· Casing in galvanized steel (TSC) internally insulated with high density material, protected on the air flowsurface,inordertoavoiderosionandscaling.

·Deviceproperfortheairflowadjustament.

ThestaticpressureupstreamtheTerminalUnitmustbenotabove50Paasregardtothevaluesindicatedin the diagrams.

Example: TSC1:Q=100m3/h-Hst=30Pa Staticpressuremax:80Pa

TSCairterminalunitsareinaccordancetoIMOA163FireresistanceB15class.

The air distribution is made using round or square diffusers (supplyloose);theairflowregulationismadebymeansofa manual rotation of a knob in the diffuser. (See “Diffuser for Air Terminal Units” brochure).

CONSTRUCTIVES FEATURES AND PERFOMANCES

TSCterminals,areavailablein5sizes,themaxairflowcapacityforeachsize,areasfollows:

SIZES AND RELEVANT AIR FLOW

SIZE Q(m3/h)

1 ≤1202 120-2003 200-300

4 300-4005 400-500

Page 4: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|4

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

SELECTION DIAGRAMS

Thefollowingdiagramsarereferedtostandardair(=1,225kg/m3)andreporttheairflow,thepressuredropand the air noise in terms of sound power levels Lw(ref.10-12 W).

Thesoundpowerlevelsmentionedinthediagrams,with±2dBtolerance,referstotheoutletairflowfromtheterminal unit without the diffuser.

Page 5: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|5

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

Page 6: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|6

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

SOUND ATTENUATION

Inside rooms or cabins, it is necessary to grant a well defined level of sound pressure LP (ref.2*10-5Pa).

Ls, obviously depending from Lw (see charts), is equal to the logarithmic sum of the direct sound pressure level andreflexsoundpressurelevel.

Lp=Lpd + Lpr

where: Lpd=Lw-ΔdLpr=Lw-Δr

SOUND LEVEL

Hz

125 250 500 1000 2000 4000 8000TSC 1 2 3 25 29 32 31 28TSC 2 1 4 19 25 30 30 28

TSC 3 1 4 19 24 31 31 28

TSC 4 0 3 16 20 27 29 28TSC 5 0 4 14 21 27 28 28

ThereductionofsoundenergycomingfromTSCsingleductterminalunitsindB(re.10-12 W) and for each octave band, is the following:

TERMINAL POSITIONDISTANCE FROM THE

TERMINAL [m]Δd [dB]

1 1.2 9.62 1.2 6.6

3 1.2 3.6

1 1.5 11.52 1.5 8.53 1.5 5.5

SOUND ABSORPION OF THE ROOM [m2]

Δr [dB]

5 16 1.8

7 2.4

8 39 3.510 4

LOCATION OF THE AIR TERMINAL

Page 7: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|7

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

DIMENSIONS AND WEIGHTS

MODELDIMENSIONS (mm)

A B C D E ØF G ØH WEIGHT (KG)TSC1 495 360 150 235 125 80 315 150 8TSC2 520 420 170 265 155 100 315 200 10

TSC3 520 500 170 305 195 100 315 200 11

TSC4 590 500 210 305 195 125 340 250 14TSC5 635 550 250 330 220 150 360 300 17

Page 8: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|8

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

DIFF

USIO

N E

LEM

ENTS

TSCR air distribution terminal with electric re-heating have been appositely designed for ceiling installation on board of ships and permit, by means of a room thermostat, the individual regulation of the temperature inside the rooms and, by means of a manual control, the regulation of the air flow.

AIR TERMINALUNITS - TSCR

TSCR

Page 9: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|9

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

CONSTRUCTIVES FEATURES AND PERFOMANCES

TSCRairterminalunitsareinaccordancetoIMOA163fireresistanceB15class.

Theair flow regulation ismadebymeansofamanualrotation of a knob; the air distribution is made by means of round or square diffusers (supplied as option).

TSCRterminalunitiscomposedof:

·Casingingalvanizedsteelinternallyinsulatedwithhighdensitymaterial,protectedontheairflowsurface, in order to avoid erosion and scaling.

·Deviceproperfortheairflowadjustament..

·Anelectric2stepheater,removablefromtheexternalsideoftheterminal,completeofautomaticresetsafetythermostat;designedforasinglephasevoltage-230V.

· An electric board, completely insulated from the air stream containing electrical connections.

ThestaticpressureupstreamtheTerminalUnitmustbenotabove50Pacomparedtothevaluesindicatedin the diagrams.

Example: TSCR1:Q=100mc/h-Hst=30Pa Staticpressuremax=80Pa

TSCRterminals,areavailablein5sizes,themaxairflowcapacityforeachsize,areasfollows:

SIZES AND RELEVANT AIR FLOW

SIZE Q(m3/h) Watt StepsTSCR 1 ≤120 500 2TSCR 2 120-200 500 2

TSCR 2 120-200 1000 2

TSCR 3 200-300 1000 2TSCR 3 200-300 1500 2TSCR 4 300-400 1000 2TSCR 4 300-400 1500 2TSCR 4 300-400 2000 2TSCR 5 400-500 1500 2TSCR 5 400-500 2000 2

Page 10: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|10

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

SELECTION DIAGRAMS

Thefollowingchartsarereferedtostandardair(p=1,225kg/m3)andreporttheairflow,thepressuredropandthe air noise in terms of sound power levels Lw(ref.10-12 W).

Thesoundpowerlevelsmentionedinthecharts,with±2dBtolerance,referstotheoutletairflowfromtheter-minal unit without the diffuser.

Page 11: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|11

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

Page 12: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|12

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

SOUND ATTENUATION

Inside rooms or cabins, it is necessary to grant a well defined level of sound pressure LP(ref.2*10-5Pa).

Ls, obviously depending from Lw (see charts), is equal to the logarithmic sum of the direct sound pressure level andreflexsoundpressurelevel.

Lp=Lpd + Lpr

where: Lpd=Lw-ΔdLpr=Lw-Δr

SOUND LEVEL

Hz

125 250 500 1000 2000 4000 8000TSCR 1 2 3 25 29 32 31 28TSCR 2 1 4 19 25 30 30 28

TSCR 3 1 4 19 24 31 31 28

TSCR 4 0 3 16 20 27 29 28TSCR 5 0 4 14 21 27 28 28

The reduction of sound energy coming from TSCR single duct terminal units in dB (re.10-12 W) and for each octave band, is the following:

TERMINAL POSITIONDISTANCE FROM THE

TERMINAL [m]Δd [dB]

1 1.2 9.62 1.2 6.6

3 1.2 3.6

1 1.5 11.52 1.5 8.53 1.5 5.5

SOUND ABSORPION OF THE ROOM [m2]

Δr [dB]

5 16 1.8

7 2.4

8 39 3.510 4

LOCATION OF THE AIR TERMINAL

Page 13: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|13

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

DIMENSIONS AND WEIGHTS

MODELDIMENSIONS (mm)

A B C D E ØF G ØH WEIGHT (KG)TSCR 1 495 360 150 235 125 80 315 150 10TSCR 2 520 420 170 265 155 100 315 200 12

TSCR 3 520 500 170 305 195 100 315 200 13

TSCR 4 590 500 210 305 195 125 340 250 16TSCR 5 635 550 250 330 220 150 360 300 19

Page 14: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|14

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

WIRING DIAGRAM

> ROOM WITH 1 CABIN UNIT

> ROOM WITH 2 CABIN UNITS

Page 15: AIR TERMINAL UNITS€¦ · TSCR air terminal units are in accordance to IMO A 163 fire resistance B15 class. The air flowregulation is made by means of a manual rotation of a knob;

PAG|15

WWW.FRIZONIA.COM

• COMPONENTS | DIFFUSION ELEMENTS

WWW.FRIZONIA.COM

DIFF

USIO

N E

LEM

ENTS