Air Technology Solutions
for Humans and Products.
German-American Smart Buildings Symposium, Boston, MA June 2015
Presented by Gerhard Seyffer, President LTG Incorporated
© All rights reserved for LTG Aktiengesellschaft
‹#›
LTG Aktiengesellschaft – History
1919: Dr. Albert Klein,– first Patent for an Induction System in the US
1924: Foundation of LTG as first Specialized Company in Europe for Air Conditioning Systems.
.
LTG Comfort Air Technology
Induction Units,
Active Chilled
Beams
Air-Water-Systems Air Diffusers Air Distribution Engineering Services
Linear Diffusers
Swirl Diffusers
Transfer Air Devices
Industrial / Custom
Diffusers
Flow Rate
Controllers
Air Flow Tests
Thermodynamics
Acoustics / Comfort
Measurements
Customized
Solutions
Best air conditioning solutions for any room situation.
Unique performance and efficiency, comfort and acoustics.
LTG Air-Water Systems
Induction Units / Active Chilled Beams Fan Coil Units Decentralized Ventilation Units
© All rights reserved for LTG Incorporated
‹#›
Advantages – Induction Technology
LTG induction units of the latest generation are energy-efficient and can be operated and demand controlled
with LTG SmartFlow technology.
Advantages:
Energy Savings
Sustainable: long service life and low maintenance
Silent
High cooling and heating output
Cooling / Heating and fresh air supply in one unit
No fan needed in the unit
– Comfortable and Efficient
© All rights reserved for LTG Incorporated
‹#›
Information – Induction Technology
The Induction Principle
Air flowing through a nozzle forms a free jet. It induces the surrounding air layer along at its
edges and thus enlarges the flowing air volume. This
„induction“ takes place within the induction device. A special construction entrains room air
(secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh
air (primary air) the supply air then returns to the room for a comfortable climate.
– Comfortable and Efficient
Induction unit Induction principle
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Active Chilled Beams HDF / HDFsf
Power meets comfort –
and the highest requirements
Reduced duct sizes due to transport of cooling
energy with water
Energy-efficient with high cooling output and
optimized fresh air quantity (suitable for LEED
certified buildings)
Low-noise and maintenance-free
2-/4-way version for any desired room layout;
integration of extract diffuser unit possible
Space-saving: low installation height
(e. g. HDF-N only 6.3“)
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Active Chilled Beam HDC
Comfortable even in complex
installation situations.
Energy-efficient by low primary pressures and
high cooling output
Silent: very high-performance at low noise level
Low installation height possible
Two-in-one: Supply air and exhaust air in one
unit
High thermal comfort
Maintenance-friendly construction
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Induction Unit HFG-MQ
The induction unit for any
application – even for complex
installation and room situations.
High comfort by LTG mixed/displacement
ventilation
Many versions are suitable even for special
requirements like narrow or low sills
High heating / cooling output
Low-maintenance, proven and robust
Air volume and pressure can be selected
individually
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Induction Unit QHG
The induction unit for
displacement airflow.
Comfortable room climate by low flow speed
High ventilation efficiency: The thermal effects
remove hazardous substances in a targeted
manner
Flexible room design: displacement ventilation
prevents risk of draughts
Air diffusers adjustable to suit installation
situation
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Induction Unit HFVsf
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Induction Unit HFVsf
Up-to-date induction technology –
energy-efficient refurbishment
Easy: 1:1 replacement during operation
Reduce energy costs: demand-controlled
ventilation with lowest primary pressures
High user response: Supply air and cooling
variable, extremely low-noise
Robust technology, low-maintenance
Sustainable thanks to flexibility: a unit model
with various comfort stages, easily adjustable
for all types of use in the building
The Evolution of Induction
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Induction Unit HFVsf
The Evolution of Induction
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Induction Unit HFFsuite
Five stars for efficient and
silent ventilation, heating and
cooling without a fan
As quiet as a whisper even at maximum
power: 24 dB(A)
20 % more cooling output than standard
systems – also in a tight space
Maximum thermal comfort: induction control
for individualized user control, adjustable air
baffle elements
Very low operation costs: energy-saving,
maintenance-free and hard-wearing induction
technology
The perfect alternative to fan coil
solutions: easy integration, economical for
retrofit work too
© All rights reserved for LTG Incorporated
‹#›
Air-Water Systems – Under-Floor Induction Unit HFB / HFBsf
Compact and powerful.
Flexible and efficient.
Dissipates heat and cooling load at the facade
Allows for smaller ducts inside the building
No moving parts results in low maintenance
and extremely long product life time
Low noise level
Does not obstruct window or view
With LTG System Design: for a Consistent
appearance with different floor devices (e. g. with
VKB…)
© All rights reserved for LTG Incorporated
‹#›
Unit mounted in raised floor
Quiet Tangential Fan with even
velocities over discharge opening
Air inlet on room side
through heat exchanger
Air outlet along facade
All components accessable
through grille
Fan-Coil-Unit VKB - Function
Recirculation
Air
Supply Air
Outstanding performance under demanding conditions.
Unsurpassed in comfort, acoustics and design.
LTG Air Diffusers
Linear / Swirl Diffusers Displacement Diffusers Floor Diffusers Transfer Air Device Customized Solutions
© All rights reserved for LTG Incorporated
‹#›
LTG Innovations – the LTG System clean®
Contaminants within the room air like dust, tobacco smoke, carpet abrasions, dust or oil vapor deposit
around the ceiling and diffuser as a result of entrainment. The LTG System clean® prevents surface
staining almost completely by providing a screen of clean supply air across the ceiling. Benefits: The costs
of renovation and maintenance are considerably reduced.
The LTG System clean® is available for the products LDB, LDK-B and LDR
LTG System clean® – unique and ingenious!
The LTG System clean®: part of the supply air is diffused directly along the ceiling and prevents contamination
© All rights reserved for LTG Incorporated
‹#›
Air Diffusers – Swirl Diffuser DLA
The highly inductive spot diffuser. Can be
applied versatilely in offices, restaurants,
laboratories and shopping centres.
Fresh air everywhere: Optimal, efficient 360-
degree ventilation
Easy to operate: Easy flow rate control
Inexpensive to install: With central fastener up
to an installation size of 625
Flexible: Factory preset swirl disk, fast and easy
to adjust to changed room conditions
Low maintenance: Minimal cleaning necessary,
depending on design
Choice of housings: Rectangular, pyramid or
cylindrical boxes. Pyramid boxes are stackable
for low transport costs
© All rights reserved for LTG Incorporated
‹#›
Air Diffusers – Floor-mounted Linear Air Diffuser LDU-W
Comfortable and draft-free
heating, cooling and venting.
Quiet and draft-free with highly efficient
ventilation
Energy efficient: Thermal shielding of glass
façades
A unified look meets exacting demands for
attractive design
Height-adjustable feet, easy to align – ideal for
raised access floors
Flexible design of exhaust grid; visual
continuity with other LTG floor units
More security for your investment.
LTG Engineering Services
Air Flow Tests Thermodynamics Acoustics / Comfort Measurements Customized Solutions
www.LTG-INC.net
Air Technology Solutions
for Humans and Products.
www.LTG-INC.net
Air Technology Solutions
for Humans and Products.
www.LTG-INC.net
Air Technology Solutions
for Humans and Products.
LTG Incorporated
105 Corporate Dr
Spartanburg, SC 29303
USA
Tel.: +1 (864) 599-6340
Fax: +1 (864) 599-6344
www.LTG-AG.com
www.LTG-INC.net
LTG Aktiengesellschaft
Grenzstr. 7
70435 Stuttgart
Deutschland
Tel.: +49 (0) 711 8201-0
Fax: +49 (0) 711 8201-720