Air Diffusion - WallandCeilingGrills

42
October 2010 Wall and Ceiling Grilles Features Curved Blade Single and Double Deflection Fixed and Removable Core Eggcrate Perforated Grille 45° Fixed Blade Non Vision Bar Grilles Welded Frame Construction Optional Opposed Blade Damper Models CB, SD, DD, EC, PG, G45, NVG, NB, GN, WB and GW , Wall and Ceiling Grille Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk

description

Air Diffusion - Wall and Ceiling Grills

Transcript of Air Diffusion - WallandCeilingGrills

Page 1: Air Diffusion - WallandCeilingGrills

October 2010 Wall and Ceiling Grilles

Features

●Curved Blade

● Single and Double Deflection

● Fixed and Removable CoreEggcrate

● Perforated Grille

● 45° Fixed Blade

●Non Vision

●Bar Grilles

●Welded Frame Construction

●Optional Opposed BladeDamper

Models CB, SD, DD, EC, PG, G45, NVG, NB, GN, WB and GW,

Wall and Ceiling Grille

Grilles Diffusers Louvres Chilled Beams

Ruskin Air Management Limitedwww.ruskinuk.co.uk

Page 2: Air Diffusion - WallandCeilingGrills

Model SA Louvre Face Ceiling Diffuser

Page

Introduction Page 3

Model CB Curved Blade Ceiling Grille Pages 4 – 7

Model SD Single Deflection Grille and Model DD Double Deflection Grille Pages 8 – 15

Model EC Egg Crate Grille Pages 16 – 19

Model PG Perforated Grille Page 20

Model G45 45° Fixed Blade Grille Pages 21 – 23

Model NVG Non Vision Grille Pages 24 – 25

Model NB Narrow Blade Bar Grille Page 26

Model GN Narrow Blade Bar Grille Page 27

Model WB Wide Blade Bar Grille Page 28

Model GW Wide Blade Bar Grille Page 29

Models NB, GN, WB and GW Dimensions Pages 30 – 32

Performance Guide Pages 33 – 36

Installation Guide Pages 37 – 38

Ordering Information Page 39

Product Range Pages 40 – 41

Contents

Wall and Ceiling Grilles

2 www.air-diffusion.co.uk

Page 3: Air Diffusion - WallandCeilingGrills

Having successfullymanufactured grilles, registersand diffusers since 1972, Air Diffusion has the productto satisfy almost every wall orceiling grille application usedin conventional air distributionor ventilation systems. Thecomprehensive range can beused in both supply or extractsystems and includes curvedblade ceiling mounted grilles,single and double deflectiongrilles, egg crate grilles,perforated core grilles, fixedblade grilles, non vision grilles,and narrow or wide blade bargrilles.

Introduction

Model CB4 Curved Blade Ceiling Grille

Model SD Single Deflection Grille

Model WB Wide Blade Bar Grille

Model NB Narrow Blade Bar Grille

Model DDDouble Deflection Grille

Model EC Egg Crate Grille

Model PG Perforated Grille

Model G45 45° Fixed Blade Grille

Model NVG Non Vision Grille

Wall and Ceiling Grilles

www.air-diffusion.co.uk 3

Page 4: Air Diffusion - WallandCeilingGrills

Model SA Louvre Face Ceiling Diffuser

Model CB Curved Blade Ceiling Grille

DescriptionModel CB curved blade ceiling grilleincorporates individually adjustable bladesto alter the angle of discharge. The grillecan provide 1 way, 2 way, 3 way or 4 wayair patterns. The grille is suitable for soffitor ceiling mounting and may be used forsupply or extract applications. Typicalinstallations include offices, shops, hotels,colleges, universities, hospitals and mostcommercial or industrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No.8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes inflange.

An optional opposed blade damper can befitted to the rear of the grille and adjustedthrough the grille core.

Specification

MaterialExtruded aluminium sections

Construction25mm wide flange frame with cornersmitred and welded. Adjustable blades arefixed to the frame using starlock washersand securing wire.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1– Countersunk Screw Holes in Flange(Standard).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS)

For Installation Guide see Pages 37 / 38.AccessoriesAvailable fitted with opposed blade damperadjusted through the grille core.Finish0 – Mill extruded aluminium.2 – Silver (RAL9006) polyester powder coat.3 – White (RAL9010) 20% polyesterpowder coat. (Standard).4 – Black (RAL9005) polyester powder coat.6 – Special polyester powder coat.(Please state separately the RAL colourreference and finish type required).Model TypesModel CB1LG is supplied as a grille onlyhaving a 1 way air pattern with bladesrunning parallel to the longest side.Model CB1SG is supplied as a grille onlyhaving a 1 way air pattern with bladesrunning parallel to the shortest side.

Model CB2LG is supplied as a grille onlyhaving a 2 way air pattern with bladesrunning parallel to the longest side.Model CB2SG is supplied as a grille onlyhaving a 2 way air pattern with bladesrunning parallel to the shortest side.Model CB2SG (LH) is supplied as a grilleonly having a 2 way corner air pattern with1 set of blades running parallel to theshortest side and 1 set at right angles lefthanded.Model CB2SG (RH) is supplied as a grilleonly having a 2 way corner air pattern with1 set of blades running parallel to theshortest side and 1 set at right angles righthanded.

Model CB3LG is supplied as a grille onlyhaving a 3 way air pattern with outerblades running parallel to the longest side.

Model CB3SG is supplied as a grille onlyhaving a 3 way air pattern with outerblades running parallel to the shortest side.

Model CB3SG (EQ) is supplied as a grilleonly having a 3 way air pattern with the 2outer blade sets running parallel to theshortest side with an equal size 3rd setlocated in the centre.

Model CB4LG is supplied as a grille onlyhaving a 4 way air pattern with outerblades running parallel to the longest side.

Model CB4SG is supplied as a grille onlyhaving a 4 way air pattern with outerblades running parallel to the shortest side.

If an opposed blade damper is requiredthe code reference letter G is replaced byR to denote that a damper is to be fitted.

(e.g. CB4SR = 4 way air pattern with outerblades running parallel to the shortest side,fitted with an OBD).

DimensionsMinimum size, subject to air pattern, is100mm x 100mm up to a maximum singlesection of 1000mm x 1000mm. Specialsizes also available.

Model CB1- No. 2 Finish Model OBD

Model CB2 - No. 3 Finish

Model CB4 - No. 3 Finish

Wall and Ceiling Grilles

4 www.air-diffusion.co.uk

Page 5: Air Diffusion - WallandCeilingGrills

L - C B1

S - C B1

1 way discharge

L - C B2 (Opp.) S - C B2 (Opp.)

2 way discharge

S - C B2 (LH)

*

*

* Minimum dimension 245mm for equal sections

* Minimum dimension 100mm

S - C B2 (RH)

*

S - C B4

4 way discharge

L - C B3

3 way discharge - options

* Minimum dimension 295mm

*S - C B3

L - C B3 (EQ)

3 way discharge - standard

L - C B4

4 way discharge68.5

If overall dimensions are critical, these must be stated

Opposed blade volume control damper

Opposed blade volume control damper

32

Duc

t Siz

e –1

9mm

Nom

inal

Siz

e =

Ope

ning

Siz

e

2525

68.5

20

32

Overall Size = Duct Size + 45

No.8 countersunk screw fixing holes

Models CB1G CB1R CB2G CB2R

DimensionsModel CB Air Patterns

Wall and Ceiling Grilles

www.air-diffusion.co.uk 5

Page 6: Air Diffusion - WallandCeilingGrills

Model CB 1 Way and 2 Way Curved Blade Ceiling Grille

20

15

10987

6

5

4

3

2

1

1

2

3

4

15

15

45

40

35

30

25

20

10987

6

5

3000

2500

2000

1500

1000900

800

700

600

500

400

300

250

200

150

100

90

80

70

60

50

40

30

20

VO

LUM

E L

ITR

ES

/S

60

12

150 100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850900950

100010501100

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950

10001050110011501200

1098765

4

32.5

2.0

1.5

1.0

0.5

50403020

15

10

5

THR

OW

ME

TRE

S

N.R

.L.W

. SO

UN

D P

OW

ER

LE

VE

L

TOTA

L P

RE

SS

UR

E P

a

DU

CT

VE

LOC

ITY

M/S

MIL

LIM

ETR

ES

PIV

OT

LIN

E

MIL

LIM

ETR

ES

1–W

AY T

HR

OW

2–W

AY T

HR

OW

10C

CO

OLI

NG

Models CB1/CB1R, CB2/CB2RNomogram

Performance

Maximum recommended air volume for free space cooling application

Ceiling height m. 2.4 2.75 3.0 3.7 4.5 6.0

Volume 1 Way L/S 80 125 200 300 450 950

Volume 2 Way L/S 160 250 400 600 900 1900

Throw values are based on grilles or registers mounted in an unobstructed ceiling application.Sound power and pressure levels are based on supply with dampers fully open.Without dampers subtract 2dB and multiply total pressure x 0.9.Sizes indicated are standard but all sizes are available.Throw values are based on 10° C cooling application. For Isothermal multiply x 1.25.

Wall and Ceiling Grilles

6 www.air-diffusion.co.uk

Page 7: Air Diffusion - WallandCeilingGrills

3000

1

11

60

45

40

35

30

25

20

5

10

15

2030405060

121098765

4

32.5

2.0

1.5

1.0

0.5

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

9501000

1050110011501200 1100

10501000950900850

800

750

700

650

600

550

500

450

400

350

300

250

200

150

100

10987

6

5

4

3

2

12

3

4

5

6

7

89

10

15

12

2500

2000

1500

1000900

800

700

600

500

400

500

250

200

150

100

90

80

70

60

50

40

30

20

VO

LUM

E L

ITR

ES

/S

THR

OW

ME

TRE

S

N.R

.L.W

. SO

UN

D P

OW

ER

LE

VE

L

TOTA

L P

RE

SS

UR

E P

a

DU

CT

VE

LOC

ITY

M/S

MIL

LIM

ETR

ES

PIV

OT

LIN

E

MIL

LIM

ETR

ES

3–W

AY T

HR

OW

4–W

AY T

HR

OW

10C

CO

OLI

NG

Model CB 3 Way and 4 Way Curved Blade Ceiling Grille

Models CB3/CB3R, CB4/CB4RNomogram

Performance

Maximum recommended air volume for free space cooling application

Ceiling height m. 2.4 2.75 3.0 3.7 4.5 6.0

Volume 3 Way L/S 240 375 600 900 1350 2850

Volume 4 Way L/S 320 500 800 1200 1800 3800

Throw values are based on grilles or registers mounted in an unobstructed ceiling application.Sound power and pressure levels are based on supply with dampers fully open.Without dampers subtract 2dB and multiply total pressure x 0.9.Sizes indicated are standard but all sizes are available.Throw values are based on 10° C cooling application. For Isothermal multiply x 1.25.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 7

Page 8: Air Diffusion - WallandCeilingGrills

Cor

e si

ze =

Nom

inal

Siz

e –1

925

25

Nom

inal

Siz

e =

Ope

ning

Siz

e

20

25

32 68.5

Opposedblade volume control damper

Overall Size = Nominal Size +45

Model SD Single Deflection Grille

DescriptionModel SD single deflection grilleincorporates a set of individuallyadjustable blades. The blades may beeither horizontal or vertical. The grille issuitable for sidewall, soffit or cill mountingand may be used for supply or extractapplications. Typical installations includeoffices, shops, hotels and mostcommercial or industrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No.8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes inflange.

An optional opposed blade damper canbe fitted to the rear of the grille andadjusted through the grille core.

Specification

MaterialExtruded aluminium sections

Construction25mm wide flange frame with cornersmitred and welded. Adjustable blades are5mm wide, 21mm deep on a 20mm pitchand secured into the frame by starlockwashers and securing wire.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1– Countersunk Screw Holes in Flange(Standard).

F2 – Spring Clips (not recommended forceiling or high sidewall installation).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS).

For Installation Guide see Page 37/ 38.

AccessoriesAvailable fitted with opposed bladedamper adjusted through the grille core.

Finish0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powder coat.

3 – White (RAL9010) 20% polyesterpowder coat (Standard).

4 – Black (RAL9005) polyester powdercoat.

6 – Special polyester powder coat finish.(Please state separately the RAL colourreference and finish type required).

Model Types

Model SDHG is supplied as a grille onlywith a single set of horizontal blades,along longest side.

Model SDVG is supplied as a grille onlywith a single set of vertical blades, alonglongest side.

Model SDHR is supplied as a grillehaving a single set of horizontal blades,along longest side and fitted with anOBD.

Model SDVR is supplied as a grille havinga single set of vertical blades, alonglongest side, and fitted with an OBD.

DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1000mm x1000mm. Special sizes also available.

Model SD - No. 3 Finish Model SD - No. 2 Finish Model OBD

Wall and Ceiling Grilles

8 www.air-diffusion.co.uk

Page 9: Air Diffusion - WallandCeilingGrills

Model DD Double Deflection Grille

DescriptionModel DD double deflection grilleincorporates two sets of individuallyadjustable blades. The front blades maybe either horizontal or vertical. The grille issuitable for sidewall, soffit or cill mountingand may be used for supply or extractapplications. Typical installations includeoffices, shops, hotels and mostcommercial or industrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No.8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes inflange.

An optional opposed blade damper canbe fitted to the rear of the grille andadjusted through the grille core.

Specification

MaterialExtruded aluminium sections

Construction25mm wide flange frame with cornersmitred and welded. Adjustable blades are5mm wide, 21mm deep on a 20mm pitchand secured into the frame by starlockwashers and securing wire.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1– Countersunk Screw Holes in Flange(Standard).

F2 – Spring Clips (not recommended forceiling or high sidewall installation).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS).

For Installation Guide see Page 37/ 38.

AccessoriesAvailable fitted with opposed bladedamper adjusted through the grille core.

Finish0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powdercoat.

3 – White (RAL9010) 20% polyesterpowder coat finish (Standard).

4 – Black (RAL9005) polyester powdercoat.

6 – Special polyester powder coat finish(Please state separately the RAL colourreference and finish type required).

Cor

e si

ze =

Nom

inal

Siz

e –1

925

25

Nom

inal

Siz

e =

Ope

ning

Siz

e

20

60

Opposedblade volume control damper

25

96.5 Overall Size = Nominal Size +45

Model Types

Model DDHG is supplied as a grille onlywith one set of front horizontal and oneset of rear vertical blades.

Model DDVG is supplied as a grille onlywith one set of front vertical and one setof rear horizontal blades.

Model DDHR is supplied as a grillehaving one set of front horizontal and oneset of rear vertical blades and fitted withan OBD.

Model DDVR is supplied as a grille havingone set of front vertical blades and oneset of rear horizontal blades and fittedwith an OBD.

DimensionsMinimum size is 100mm x 100mm up to amaximum single section of 1000mm x1000mm. Special sizes also available.

Model DD - No. 3 Finish Model DD - No. 2 Finish Model OBD

Wall and Ceiling Grilles

www.air-diffusion.co.uk 9

Page 10: Air Diffusion - WallandCeilingGrills

L

1.5

1.25

1.00.90.80.7

0.6

0.5

Curve X

Curve Y

0.4

0.3

0.25

–14 –12 –10 – 8 –6 – 4 –2 0 2 4 6 8 10 12 14 16

Thr

ow

Fac

tor

(Cat

alog

ue th

row

x fa

ctor

= c

orre

cted

thro

w)

Temperature Difference °C

The effect of temperature on vertical discharge

Cooling – Heating+

Model SD Single Deflection Grille and ModelDD Double Deflection Grille

Model SD and DD Selection procedure

Grille Grille WidthHeight 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200100 .0084 .0117 .0150 .0182 .0215 .0247 .0280 .0312 .0344 .0377 .0442 .0507 .0572 .0637 .0702 .0767150 .0133 .0185 .0236 .0287 .0338 .0390 .0441 .0492 .0543 .0595 .0697 .0799 .0902 .1005 .1107 .1210200 .0182 .0252 .0322 .0392 .0462 .0532 .0602 .0672 .0742 .0812 .0952 .1092 .1232 .1372 .1512 .1652250 .0231 .0320 .0408 .0497 .0586 .0675 .0763 .0852 .0941 .1030 .1207 .1385 .1562 .1740 .1917 .2095300 .0280 .0387 .0494 .0602 .0710 .0817 .0925 .1032 .1140 .1247 .1462 .1677 .1892 .2107 .2322 .2537350 .0328 .0455 .0581 .0707 .0833 .0959 .1086 .1212 .1338 .1465 .1717 .1970 .2222 .2475 .2727 .2980400 .0377 .0522 .0667 .0812 .0957 .1102 .1247 .1392 .1537 .1682 .1972 .2262 .2552 .2842 .3132 .3422450 .0426 .0590 .0753 .0917 .1081 .1245 .1408 .1572 .1736 .1900 .2227 .2555 .2882 .3210 .3537 .3865500 .0475 .0657 .0840 .1022 .1205 .1387 .1570 .1752 .1935 .2117 .2482 .2847 .3212 .3577 .3942 .4307550 .0523 .0724 .0926 .1127 .1328 .1530 .1731 .1932 .2133 .2335 .2737 .3140 .3542 .3945 .4347 .4750600 .0572 .0792 .1012 .1232 .1452 .1672 .1892 .2112 .2332 .2552 .2992 .3432 .3872 .4312 .4752 .5192

Curve Reference

X L = Up to 0.5m

Y L = More than 2.0m

1. Determine air volume flowrate per outlet.

2. If a supply application,establish available throw – useSD/DD selection nomogram.

3. Establish requiredmaximum noise and pressurevalues – for exhaust useSD/DD selection nomogram.

4. With a straight edge lineacross from the litres persecond value through valueswithin the maximumparameters established to thepivot line.

5. Retaining the position ofintersection at the pivot line,pivot the straight edge until itmeets acceptable values ofsize to its left and right.

Note:The pivot line represents anarea and by maintainingposition on this line widthsand heights can be selectedof equal area. See noteregarding effect of aspectratio on throw for supplyapplication.

SDH Maximum Free Area – Blades at 0°

Grille Grille WidthHeight 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200100 .0082 .0112 .0142 .0172 .0202 .0232 .0262 .0292 .0322 .0352 .0412 .0472 .0532 .0592 .0652 .0712150 .0133 .0182 .0231 .0280 .0328 .0377 .0426 .0475 .0523 .0572 .0670 .0767 .0865 .0962 .1060 .1157200 .0185 .0252 .0320 .0387 .0455 .0522 .0590 .0657 .0724 .0792 .0927 .1062 .1197 .1332 .1467 .1602250 .0236 .0322 .0408 .0494 .0581 .0667 .0753 .0840 .0926 .1012 .1185 .1357 .1530 .1702 .1858 .2047300 .0287 .0392 .0497 .0602 .0707 .0812 .0917 .1022 .1127 .1232 .1442 .1652 .1862 .2072 .2282 .2492350 .0338 .0462 .0586 .0710 .0833 .0957 .1081 .1205 .1328 .1452 .1700 .1947 .2195 .2442 .2690 .2937400 .0390 .0532 .0675 .0817 .0959 .1102 .1245 .1387 .1530 .1672 .1957 .2242 .2527 .2812 .3097 .3382450 .0441 .0602 .0763 .0925 .1086 .1247 .1408 .1570 .1731 .1892 .2215 .2537 .2860 .3182 .3505 .3827500 .0492 .0672 .0852 .1032 .1212 .1392 .1572 .1752 .1932 .2112 .2472 .2832 .3192 .3552 .3912 .4272550 .0543 .0742 .0941 .1140 .1338 .1537 .1736 .1935 .2133 .2332 .2730 .3127 .3525 .3922 .4319 .4717600 .0595 .0812 .1030 .1247 .1465 .1682 .1900 .2117 .2335 .2552 .2987 .3422 .3857 .4292 .4727 .5162

SDV Maximum Free Area – Blades at 0°

Wall and Ceiling Grilles

10 www.air-diffusion.co.uk

Vertical dischargingairstreams are affectedby temperature andthe resulting densitydifference between thedischarging air andambient air. Throw isalso affected by theproximity of surfaces.Use the graph aboveto provide a correctionfactor to apply tocatalogue throws.

Note: The relativetemperature values arebased on downwarddischarge – for upwarddischarge reverse theheating and coolingeffect.

Page 11: Air Diffusion - WallandCeilingGrills

BLA

DE

SS

ET

AT22°

BLA

DE

SS

ET

AT0°

BLADESSET

AT45°

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

7 6 5 4 3 2 1 0

Metres

Spread characteristics of deflection grilles

Me

tre

s

1 2 3 4 5 6 7

Model SD Single Deflection Grille andModel DD Double Deflection Grille

ThrowThrows shown in thecatalogue are based onhorizontal discharge of cooledair with full attachment of thejet to a flat ceiling closeenough above the grilleposition to enable thiscondition to occur. For mostcases for ceiling effect thegrille would be positioned nomore than 300mm below theceiling.

The catalogue gives figuresfor throw at 0° and 40° bladedeflection being the full rangeof throw available. It is goodpractice to select for therequired throw at the midpoint of the range. in theexample on SD/DDnomogram the selection isideal for an available throw of6.5m.

Throws given are thehorizontal distance to aterminal velocity of 0.25m/s.

DropThe effect of drop with ceilingeffect and ceiling heights of2.6 – 500 litres per secondper outlet if correctly selectedshould not cause problemsup to a cooling temperaturedifferential of 10 °C.

Free Space SupplyIn free space horizontaldischarge applications thedirection of the air will bedependant on the relativetemperature of the primary airto ambient. This can causeunsatisfactory conditioning ofoccupied zone and in somecases vertical discharge downor up walls is a more suitableapproach. (Please refer to thechart showing the effect oftemperature and surface tovertical discharge – fig 1).

Throw is reduced in freespace where there is noceiling effect or other surfaceproximity and reduction forisothermal conditions is 30%

from the figures given on thenomogram.

For primary air above orbelow ambient the throwmeasured horizontally iseffected by the mass andtemperature – fig 3 illustratestypical centre of jet airpatterns at the same massand different temperatures.

SpreadThe spread of air at differentblade angles is given in fig 2.Spread can be used toestablish fixing centres formultiple outlets. It should beconsidered that if spread isrestricted by impingement ofadjacent air streams orobstructions the effectivespread will be reduced andthe length of throwproportionately increased.

Aspect RatioFrom all the points above it isclear that throw is a complexderived value and anotherfactor which has an effect isthe aspect ratio or proportionof the largest nominaldimension to the smallest.

Nomogram figures can betaken for aspect ratios from1:1 to 2:1 but if the aspectratio is greater then thefollowing factors can beapplied.3:1 Reduce throw by 5%4:1 Reduce throw by 8%5:1 Reduce throw by 12%

Pressure LossThe total pressure lossesgiven are for grilles anddampers fitted with thedamper fully open and bladesat 0°. For blades at 40° add50% to pressure values givenalthough a 10% reduction ofthe value can be taken forgrilles without dampers.

Model SD and DDSelection Guide

Notes to selection data

Isothermal Throw

Throw at +10° C or –10° C

Throw at +5° C or – 5° C

Sound LevelsWherever possible we giveNR power levels generated bythe product. This enables theallowances for roomcharacteristics, surfacemounting and multiple outletsfrom the sound advice leafletto be taken into account andmore accurately predict thesound pressure measured inthe occupied space.

The NR power level given forSD/DD series grilles includesfor a fully open damper, forgrilles without dampers 2dBcan be subtracted, however,the effect of partly closing thedamper for balancingpurposes can add significantlyto generated noise.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 11

Page 12: Air Diffusion - WallandCeilingGrills

Model SD Single Deflection Grille - Nomogram

3000

2500

2000

1500

1000

900

800

700

600

500

400

300

250

200

150

100

90

80

70

60

50

40

30

20

30

20

15

10

5

4

3

2

1

1.5

109

8

7

6

5

4

3

2

10987

6

150 100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

85090095010001050110011501200

200

300

250

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1050116011501200

5

4

3 10

20

30

40

50

5040

30

20

10

5

2

1

VO

LUM

E L

ITR

ES

/S

THR

OW

ME

TRE

S 1

0 C

CO

OLI

NG

40°

DE

FLE

CTI

ON

0° D

EFL

EC

TIO

N

NR

LW

SO

UN

D P

OW

ER

LE

VE

L

TOTA

L P

RE

SS

UR

E P

a (+

50%

40

DE

FLE

CTI

ON

)

SIZ

E -

MM

SIZ

E -

MM

DU

CT

VE

LOC

ITY

M/S

PIV

OT

LIN

ESound power andpressure levels arebased on supply withdampers fully openand blades at 0°. For40° blade add 8dB. Please refer toselection procedurefor details.

Wall and Ceiling Grilles

12 www.air-diffusion.co.uk

Page 13: Air Diffusion - WallandCeilingGrills

3000

2500

2000

1500

1000

900

800

700

600

500

400

300

250

200

150

100

90

80

70

60

50

40

30

20

60 50

48 40

37 30

26 20

16 10

100 10

5

4

3

2

1

0.5

50

25

10

5

2

13.0 20

9.0 15

6.0 10

150 100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

85090095010001050110011501200

200

300

250

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1050116011501200

5.5 9

4.9 8

3.2 5

3.8 6

4.4 7

1.8 3

2.4 4

0.9 2

VO

LUM

E L

ITR

ES

/S

THR

OW

ME

TRE

S 1

0 C

CO

OLI

NG

NR

LW

SO

UN

D P

OW

ER

LE

VE

L

TOTA

L P

RE

SS

UR

E P

a (+

50%

40

DE

FLE

CTI

ON

)

SIZ

E -

MM

SIZ

E -

MM

DU

CT

VE

LOC

ITY

M/S

PIV

OT

LIN

E

40°

DE

FLE

CTI

ON

0° D

EFL

EC

TIO

N

40°

DE

FLE

CTI

ON

0° D

EFL

EC

TIO

N

Model DD Double Deflection Grille - Nomogram

Sound power andpressure levels arebased on supply withdampers fully open. Please refer toselection procedurefor details.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 13

Page 14: Air Diffusion - WallandCeilingGrills

Quick Selection Performance Tables for Standard Sizes: Models SDHG - SDHR

Nominal Size Performancew x h

150 x 150 Air Volume l/s 35 58 80 102 124 146Neck Velocity m/s 2.0 3.2 4.5 5.8 7.0 8.2Noise Level NR – 18 28 35 41 46Pressure Loss Pa 6 17 33 54 79 110Throw (0 deg) m 3.2 5.1 7.3 8.2 9.2 9.8

200 x 200 Air Volume l/s 63 102 141 181 220 259Neck Velocity m/s 1.9 3.0 4.2 5.3 6.5 7.7Noise Level NR – 19 29 36 42 47Pressure Loss Pa 6 15 28 46 69 95Throw (0 deg) m 3.3 5.5 6.7 8.2 9.8 12.0

250 x 250 Air Volume l/s 98 159 221 282 344 405Neck Velocity m/s 1.8 2.9 4.0 5.1 6.3 7.4Noise Level NR – 20 29 37 43 48Pressure Loss Pa 5 14 26 43 63 88Throw (0 deg) M 4.5 6.3 8.5 11.5 13.2 14.3

300 x 300 Air Volume l/s 141 230 318 407 495 584Neck Velocity m/s 1.7 2.8 3.9 5.0 6.1 7.2Noise Level NR – 21 30 38 43 48Pressure Loss Pa 5 13 25 40 60 83Throw (0 deg) m 4.7 7.5 11.6 12.5 15.0 17.2

350 x 350 Air Volume l/s 192 313 433 554 674 794Neck Velocity m/s 1.7 2.8 3.8 4.9 6.0 7.0Noise Level NR – 21 31 38 44 49Pressure Loss Pa 5 12 24 39 58 80Throw (0 deg) m 5.6 9.0 12.2 14.1 17.2 19.1

400 x 400 Air Volume l/s 251 408 566 723 880Neck Velocity m/s 1.7 2.7 3.8 4.8 5.9Noise Level NR – 22 32 39 45Pressure Loss Pa 5 12 23 38 56Throw (0 deg) m 6.6 9.5 13.1 15.4 18.7

450 x 450 Air Volume l/s 318 517 716 915 1114Neck Velocity m/s 1.7 2.7 3.7 4.8 5.8Noise Level NR – 23 33 40 46Pressure Loss Pa 4 12 23 37 55Throw (0 deg) m 7.4 11.2 13.7 17.3 20.0

Performance Notes

Throw values are based on grilles or registers mounted in the sidewall not more than one metre below an unrestricted ceiling. For grilleslocated more than one metre below the ceiling, throw values should be reduced by approximately 25%.

Throw values are based on 10 °C cooling applications. For Isothermal throws multiply by 1.25.

Terminal Velocities are based on 0.25 m/s.

Each NR value represents the noise rating curve which will not be exceeded by the sound pressure in any of the octave bands, 125 Hzthrough to 4k Hz. Each NR value is based on a room absorption of 10 dB, re 10 watts. Each NR value is further based on registeroperating at a 0 degree deflection. Settings of 22.5 or 45 degree, increase the stated sound levels by 1 or 7 NR, respectively. A dash (-)in space indicates an NR value less than 10.

The NR level shown included for a grille with fully open obd fitted, a 2 dB reduction can be applied for grilles without an obd fitted. Theeffect of partly closing an obd for balancing purposes will significantly add to generated noise.

The pressure loss shown is for a grille with fully open obd fitted and the blades set for 0 degrees. For blades at 40 degrees a 50%addition should be applied. For grilles without an obd fitted a 10% reduction to the value shown can be applied.

For other performance or selection details please contact the sales office.

Wall and Ceiling Grilles

14 www.air-diffusion.co.uk

Page 15: Air Diffusion - WallandCeilingGrills

Quick Selection Performance Tables for Standard Sizes: Models DDHG - DDHR

Performance Notes

Throw values are based on grilles or registers mounted in the sidewall not more than one metre below an unrestricted ceiling. For grilleslocated more than one metre below the ceiling, throw values should be reduced by approximately 25%.

Throw values are based on 10 °C cooling applications. For Isothermal throws multiply by 1.25.

Terminal Velocities are based on 0.25 m/s.

Each NR value represents the noise rating curve which will not be exceeded by the sound pressure in any of the octave bands, 125 Hzthrough to 4k Hz. Each NR value is based on a room absorption of 10 dB, re 10 watts. Each NR value is further based on registeroperating at a 0 degree deflection. Settings of 22.5 or 45 degree, increase the stated sound levels by 1 or 7 NR, respectively. A dash (-)in space indicates an NR value less than 10.

The NR level shown included for a grille with fully open obd fitted, a 2 dB reduction can be applied for grilles without an obd fitted. Theeffect of partly closing an obd for balancing purposes will significantly add to generated noise.

The pressure loss shown is for a grille with fully open obd fitted and the blades set for 0 degrees. For blades at 40 degrees a 50%addition should be applied. For grilles without an obd fitted a 10% reduction to the value shown can be applied.

For other performance or selection details please contact the sales office.

Nominal Size Performancew x h

150 x 150 Air Volume l/s 35 58 80 102 124 146Neck Velocity m/s 2.0 3.2 4.5 5.8 7.0 8.2Noise Level NR – 18 28 35 41 46Pressure Loss Pa 6 17 33 54 79 110Throw (0 deg) m 2.0 3.8 5.3 6.7 7.8 8.6

200 x 200 Air Volume l/s 63 102 141 181 220Neck Velocity m/s 1.9 3.0 4.2 5.3 6.5Noise Level NR – 19 29 36 42Pressure Loss Pa 6 15 28 46 69Throw (0 deg) m 3.0 5.4 6.7 8.2 9.8

250 x 250 Air Volume l/s 98 159 221 282 344Neck Velocity m/s 1.8 2.9 4.0 5.1 6.3Noise Level NR – 20 29 37 43Pressure Loss Pa 5 14 26 43 63Throw (0 deg) M 4.2 6.3 8.4 11.0 12.5

300 x 300 Air Volume l/s 141 230 318 407 495Neck Velocity m/s 1.7 2.8 3.9 5.0 6.1Noise Level NR – 21 30 38 43Pressure Loss Pa 5 13 25 40 60Throw (0 deg) m 4.5 7.5 10.8 12.5 15.0

350 x 350 Air Volume l/s 192 313 433 554 674Neck Velocity m/s 1.7 2.8 3.8 4.9 6.0Noise Level NR – 21 31 38 44Pressure Loss Pa 5 12 24 39 58Throw (0 deg) m 5.5 9.0 12.5 14.5 17.2

400 x 400 Air Volume l/s 251 408 566 723 880Neck Velocity m/s 1.7 2.7 3.8 4.8 5.9Noise Level NR – 22 32 39 45Pressure Loss Pa 5 12 23 38 56Throw (0 deg) m 6.6 10.0 12.9 15.8 18.7

450 x 450 Air Volume l/s 318 517 716 915 1114Neck Velocity m/s 1.7 2.7 3.7 4.8 5.8Noise Level NR – 23 33 40 46Pressure Loss Pa 4 12 23 37 55Throw (0 deg) m 7.8 11.0 14.5 16.2 20.5

Wall and Ceiling Grilles

www.air-diffusion.co.uk 15

Page 16: Air Diffusion - WallandCeilingGrills

Model EC Egg Crate Grilles

DescriptionModel EC egg crate grille incorporates a12.5mm lattice style high free area core ineither fixed or removable core versions.The grille is suitable for sidewall, soffit orceiling mounting and is normally used forextract applications. Typical installationsinclude offices, shops, hotels, restaurants,schools and most commercial orindustrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No. 8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes inflange.

An optional opposed blade damper canbe fitted to the rear of the grille andadjusted through the grille core.

Specification

MaterialExtruded aluminium sections

Construction25mm flange frame or 44mm wide flangewith corners mitred and welded. (44mmwide flange only suitable for fixed core).

The fixed core is located within the outerframe extrusion and retained in situ by theflange frame.

The removable core is fitted into a “U”channel section and retained in the outerframe by securing screws (see drawingon page17).

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1– Countersunk Screw Holes in Flange(Standard).

F2 – Spring Clips (not recommended forceiling or high sidewall installation).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS).

For Installation Guide see Page 37 / 38.

Cor

e S

ize

= N

omin

al S

ize

–19

Nom

inal

Siz

e =

Ope

ning

Siz

e

25

25

25

32 68.5

Opposed blade volume control damper

Overall Size = Nominal Size +45

Fixed Core (25mm Flange)

25

AccessoriesAvailable fitted with opposed bladedamper adjusted through the grille core.Finish0 – Mill extruded aluminium.2 – Silver (RAL9006) polyester powder coat.3 – White (RAL9010) 20% polyesterpowder coat (Standard).4 – Black (RAL9005) polyester powder coat.6 – Special polyester powder coat finish.(Please state separately the RAL colourreference and finish type required).

Model TypesModel ECG – is supplied as a grille onlywith a fixed core.Model ECG-RC – is supplied as a grilleonly with a removable core.Model ECR – is supplied as a grillehaving fixed core and fitted with an OBD.Model ECR-RC – is supplied as a grillehaving removable core and fitted with anOBD.DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1200mm x1200mm. Special sizes also available.

Model EC - No. 2 Finish Model EC - No. 3 Finish Model OBD

Wall and Ceiling Grilles

16 www.air-diffusion.co.uk

Page 17: Air Diffusion - WallandCeilingGrills

36

Opposed blade volume control damper

72.5

25C

ore

Siz

e =

Nom

inal

Siz

e –

49

Nom

inal

Siz

e =

Ope

ning

Siz

e

25

25C

ore

Siz

e =

Nom

inal

Siz

e –

49

Overall Size = Nominal Size + 45

25

No. 6 x 11/4 Screw

No. 6 Screw Clip

44C

ore

Siz

e =

Nom

inal

Siz

e –1

1

36 72.5

44C

ore

Siz

e =

Nom

inal

Siz

e –1

1

44 44

Nom

inal

Siz

e =

Ope

ning

Siz

e

Opposed blade volume control damper

Removable Core

Wide Flange

Wall and Ceiling Grilles

www.air-diffusion.co.uk 17

Page 18: Air Diffusion - WallandCeilingGrills

Model EC Egg Crate Grilles - Nomogram: Exhaust

3000

2500

2000

1500

1000

900

800

700

600

500

400

300

250

50

10

150

200

250

300

100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900950100010501100

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1050

110011501200

5

4

3

2

1

50

50

40

30

20

10

5

40

30

20

10

200

150

10

90

80

70

60

50

40

30

20

VO

LUM

E L

ITR

ES

/S

NR

LW

SO

UN

D P

OW

ER

LE

VE

L

TOTA

L P

RE

SS

UR

E P

a

DU

CT

VE

LOC

ITY

M/S

PIV

OT

LIN

E

SIZ

E -

MM

SIZ

E -

MM

11501200

Please refer toselectionprocedure fordetails.

Wall and Ceiling Grilles

18 www.air-diffusion.co.uk

Page 19: Air Diffusion - WallandCeilingGrills

100 x 100 Air Volume l/s 20 30 40 50 60 70 80Velocity m/s 2.0 2.5 3.2 3.8 4.5 5.5 6.2Noise Level NR 10 20 25 27 30 35 40Pressure Loss Pa 5 10 20 25 32 35 48

150 x 150 Air Volume l/s 40 50 60 70 80 90 100Velocity m/s 1.5 1.75 2.3 2.75 3.0 3.5 3.9Noise Level NR – 12 18 21 24 28 30Pressure Loss Pa – 5 7 11 18 22 28

200 x 200 Air Volume l/s 60 70 80 90 100 150 200Velocity m/s 1.5 1.75 1.9 2.2 2.4 3.0 4.1Noise Level NR – 11 15 19 21 28 35Pressure Loss Pa – – 5 6 8 19 29

250 x 250 Air Volume l/s 70 80 90 100 150 200 250Velocity m/s 1.0 1.2 1.5 1.75 2.2 2.8 3.8Noise Level NR – – 10 12 21 27 33Pressure Loss Pa – – – 5 7 15 25

300 x 300 Air Volume l/s 80 90 100 150 200 250 300Velocity m/s 0.75 0.9 1.1 1.5 2.1 2.8 3.2Noise Level NR – – – 15 21 28 32Pressure Loss Pa – – – – 7 13 21

350 x 350 Air Volume l/s 90 100 150 200 250 300 400Velocity m/s 0.75 0.8 1.1 1.5 2.1 2.5 3.2Noise Level NR – – – 15 21 27 32Pressure Loss Pa – – – – 7 10 20

400 x 400 Air Volume l/s 100 150 200 250 300 400 500Velocity m/s 0.6 0.8 1.1 1.75 2.0 2.6 3.0Noise Level NR – – 10 18 22 28 33Pressure Loss Pa – – – – 6 10 20

450 x 450 Air Volume l/s 150 200 250 300 400 500 600Velocity m/s 0.7 0.9 1.2 1.6 2.1 2.75 2.9Noise Level NR – – 13 19 25 28 33Pressure Loss Pa – – – – 6 10 18

500 x 500 Air Volume l/s 200 250 300 400 500 600 700Velocity m/s 0.75 0.9 1.2 1.8 2.2 2.5 2.8Noise Level NR – – 14 21 25 28 32Pressure Loss Pa – – – – 6 10 15

550 x 550 Air Volume l/s 250 300 400 500 600 700 800595 x 595 Velocity m/s 0.75 1.0 1.5 1.8 2.2 2.5 2.8Overall Noise Level NR – 11 18 23 26 28 33

Pressure Loss Pa – – – – 7 9 15

The tables are based on the grille being used for extract purposes.The total pressure losses given are for the grille fitted with a fully open damper. For grilles without dampers a 10% reduction may be applied.The noise rating levels include for a grille fitted with a fully open damper. For grilles without dampers a 2 dB reduction may be applied. The effectof part closing a damper will significantly add to the noise rating levels. A dash (–) in space indicates a noise ratings level lower than 10 NR.Where a dash (–) in space is shown this indicates a Pressure Loss less than 5 Pa.For other performance or selection details please contact the sales office.

Nominal Size Performancew x h

Performance Notes

Quick Selection Performance Tables forStandard Sizes: Models ECG - ECR

Wall and Ceiling Grilles

www.air-diffusion.co.uk 19

Page 20: Air Diffusion - WallandCeilingGrills

Model PG Perforated Grille

DescriptionModel PG perforated core grilleincorporates a 32% free area steel meshcore in an aluminium flange frame. Thegrille is suitable for sidewall, soffit orceiling mounting and is normally used forextract applications. Typical installationsinclude offices, shops, hotels, restaurants,schools and most commercial orindustrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No.8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes inflange.

An optional opposed blade damper canbe fitted to the rear of the grille andadjusted through a prepared hole in thegrille core.

SpecificationMaterialExtruded aluminium sections with a steelcore.

Construction25mm wide flange frame with cornersmitred and welded. The fixed perforatedsteel core is located within the outerframe extrusion and retained in situ by theflange frame.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1 – Countersunk Screw Holes in Flange(Standard).

F2 – Spring Clips (not recommended forceiling or high sidewall installation).

For Installation Guide see Page 26.

Overall Size = Nominal Size + 45

32

2525

Nom

inal

Siz

e =

Ope

ning

Siz

e

Cor

e S

ize

= N

omin

al S

ize

–19

AccessoriesAvailable fitted with opposed bladedamper adjusted through a prepared holein the grille core.

Finish2 – Silver (RAL9006) polyester powder coat

3 – White (RAL9010) 20% polyesterpowder coat (Standard).

4 – Black (RAL9005) polyester powder coat.

6 – Special polyester powder coat. (Pleasestate separately the RAL colour referenceand finish type).

Model Types

Model PG – is supplied as a grille onlywith a fixed core.

Model PGR – is supplied as a grillehaving fixed core and fitted with an OBD.

DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1000mm x1000mm. Special sizes also available.

Model PG- No. 3 Finish

Wall and Ceiling Grilles

20 www.air-diffusion.co.uk

Page 21: Air Diffusion - WallandCeilingGrills

Model G45 Fixed Blade Grille

DescriptionModel G45 fixed blade grille incorporatesa set of 45° aluminium blades, which canbe provided in either a one way or twoway format. The grille is suitable forsidewall, soffit or ceiling mounting and isnormally used for extract applications. Byinstalling above or below eye level thegrille is sight-proof, these grilles can alsobe provided as a continuous assembly.Typical installations include offices, shops,hotels, restaurants, schools and mostcommercial or industrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No.8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes inflange.

An optional opposed blade damper canbe fitted to the rear of the grille andadjusted through a prepared hole in thegrille core.

Specification

MaterialExtruded aluminium sections

Construction25mm wide flange frame with cornersmitred and welded. The core uses a tubeand spacer alignment at a maximum of350mm centres and is secured into theframe with the tube passing through eachblade.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1 – Countersunk Screw Holes in Flange(Standard).

F2 – Spring Clips (not recommended forceiling or high sidewall installation).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS).

For Installation Guide see Page 37.

Overall Size = Nominal Size +4568.5

Cor

e S

ize

= N

omin

al S

ize

–19

2525

32

25

Nom

inal

Siz

e =

Ope

ning

Siz

e

Opposedblade volume control damper

Type G45RType G45G

AccessoriesAvailable fitted with opposed bladedamper adjusted through a prepared holein the grille core.

Finish0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powder coat.

3 – White (RAL9010) 20% polyesterpowder coat (Standard).

4 – Black (RAL9005) polyester powder coat.

6 – Special polyester powder coat (Pleasestate separately the RAL colour referenceand finish type required).

Model Types

Model G45G – is supplied as a grille onlywith a 1 way fixed core.

Model G45R – is supplied as a grillehaving 1 way fixed core and fitted with anOBD.

Please state separately if a 2 way core isrequired.

DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1000mm x1000mm. Special sizes also available.

Model G45 - No. 2 Finish

Wall and Ceiling Grilles

www.air-diffusion.co.uk 21

Page 22: Air Diffusion - WallandCeilingGrills

Model G45 Fixed Blade Grille - Performance Guide

1. Determine air volume flow rate peroutlet.

2. Establish required maximum noise andpressure values – refer to the appropriatenomogram.

3. With a straight edge line across fromthe litres per second value throughvalues within the maximum parametersestablished to the pivot line.

4. Retaining the position of intersection atthe pivot line, pivot the straight edge untilit meets acceptable values of size to itsleft and right.

Note:The pivot line represents an area and bymaintaining position on this line widthsand heights can be selected of equalarea. See note regarding effect of aspectratio on throw for supply applications.

Please refer to additional note in SD/DDsection with regard to air jetcharacteristics under various conditions.

Pressure LossThe total pressure losses given are forgrilles and dampers fitted with thedamper fully open. A 10% reduction ofthe value can be taken for grilles withoutdampers.

Sound LevelsWherever possible we give NR powerlevels generated by the product. Thisenables the allowances for roomcharacteristics, surface mounting andmultiple outlets from the sound adviceleaflet to be taken into account and moreaccurately predict the sound pressuremeasured in the occupied space.

The NR power level given for EC seriesgrilles includes for a fully open damper, forgrilles without dampers 2dB can besubtracted, however, the effect of partlyclosing the damper for balancingpurposes can add significantly togenerated noise.

Selection Guide

Nom. Ht Nominal Width – mm

mm 150 200 250 300 350 400 500 600 700 800 900 1000 1100 1200

100 .0077 .0110 .0143 .0176 .0209 .0242 .0308 .0374 .0440 .0506 .0572 .0638 .0704 .0770

150 .0136 .0193 .0251 .0309 .0637 .0425 .0541 .0657 .0773 .0889 .1005 .1121 .1237 .1353

200 .0276 .0359 .0442 .0525 .0608 .0774 .0940 .1106 .1272 .1438 .1604 .1770 .1936

250 .0467 .0574 .0683 .0791 .1007 .1223 .1439 .1655 .1871 .2087 .2303 .2519

300 .0708 .0841 .0974 .1240 .1506 .1772 .2038 .2304 .2570 .2836 .3102

400 .1340 .1706 .2072 .2438 .2804 .3170 .3536 .3902 .4268

500 .2172 .2638 .3104 .3570 .4036 .4502 .4968 .5434

600 .3204 .3770 .4336 .4902 .5468 .6034 .6600

Core area (m2) – Preferred size

Free area factors:G45 = 0.45Based on 300 x 300 nominal size the figures abovemay vary by 5% dependent on grille size.

Wall and Ceiling Grilles

22 www.air-diffusion.co.uk

Page 23: Air Diffusion - WallandCeilingGrills

Model G45 Fixed Blade Grille - Nomogram: Exhaust

3000

2500

2000

1500

1000

900

800

700

600

500

400

300

250

200

150

100

5

4

3

2

2.5

1

150

200

250

300

350

360

400

450

500

550

600

650

700

750

800

850

900

950

100010501100

110010501000950900

850

800

750

700

650

600

550

500

450

400

350

250

200

150

100

300

11501200

0.5

10

50

4030

20

10

5

60

70

40

50

30

20

10

100

90

80

70

60

50

40

30

20

VO

LUM

E L

ITR

ES

/S

NR

LW

SO

UN

D P

OW

ER

LE

VE

L

TOTA

L P

RE

SS

UR

E P

a

SIZ

E -

MM

SIZ

E -

MM

DU

CT

VE

LOC

ITY

M/S

PIV

OT

LIN

E

12001150

Please refer toselectionprocedure fordetails.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 23

Page 24: Air Diffusion - WallandCeilingGrills

25

25

Ove

rall

Siz

e =

Nom

inal

Siz

e +

58

2025

25

56 min80 max

25

25

Ove

rall

Siz

e =

Nom

inal

Siz

e +

58

2025

25

27 min54 max

25

Nom

inal

Siz

e =

Ope

ning

Siz

e

Ove

rall

Siz

e =

Nom

inal

Siz

e +

45

2025

27

Type NVG - DFType NVG - MFType NVG

Model NVG Non Vision Air Transfer Grille

DescriptionModel NVG non vision air transfer grilleincorporates a set of inverted vee sectionvanes to ensure a vision proof assembly.A matching flange is available for eitherstandard or extra wide doors or partition.The grille is suitable for sidewall, door orpartition mounting and is normally usedfor extract or air transfer applications.Typical installations include offices, shops,hotels, restaurants, schools and mostcommercial or industrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing is with No.8 countersunkheaded screws (BY OTHERS) usingprepared countersunk screw holes in flange.

Specification

MaterialExtruded aluminium sections

Construction25mm wide flange frame with cornersmitred and welded. Overlapping inverted“v” aluminium sections are used for thevision proof core.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1 – Countersunk Screw Holes in Flange(Standard).

For Installation Guide see Page 37.

AccessoriesStandard matching flange for 27mm to54mm door/partition.

Deep matching flange for 56mm to 80mmdoor/partition.

Double core for light-proof applications.

Finish0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powder coat.

3 – White (RAL9010) 20% polyesterpowder coat (Standard).

4 – Black (RAL9005) polyester powder coat.

6 – Special polyester powder coat ((Pleasestate separately the RAL colour referenceand finish type required).

Model Types

Model NVG – is supplied as a grille only.

Model NVG-MF – is supplied as a grillewith a standard matching flange.

Model NVG-DF – is supplied as a grillewith a deep matching flange.

DimensionsMinimum size is 100mm x 100mm up to amaximum single section of 1200mm x1200mm. Special sizes also available.

Model NVG - No. 3 Finish Model NVG-MF - No. 2 Finish

Wall and Ceiling Grilles

24 www.air-diffusion.co.uk

Page 25: Air Diffusion - WallandCeilingGrills

Model NVG Non Vision Air Transfer Grille

Selection Procedure

Typical selection of the most commonsizes are given in the table oppositealthough a full range of sizes is available.When transferring air into critical spacessuch as office it is good practice to limitface velocities to about 1.0m/s. Whentransferring into non critical spaces suchas corridors, velocities can be increasedup to the maximum sound or pressurelimits.

Nominal Face Total SoundSize Volume Velocity Pressure Powermm Litres/sec m/s Pa Level

200 x 200 20 0.5 4 10

30 0.75 7 14

40 1.00 10 17

50 1.25 14 22

60 1.5 20 26

70 1.75 26 31

300 x 300 45 0.5 4 10

68 1.75 7 18

90 1.00 10 23

113 1.25 14 27

135 1.5 19 30

158 1.75 25 34

450 x 300 68 0.5 4 13

100 0.75 7 18

135 1.00 10 24

170 1.25 14 30

200 1.5 19 33

236 1.75 25 37

450 x 450 100 0.5 4 14

150 0.75 7 21

200 1.00 10 26

250 1.25 14 32

300 1.5 19 36

350 1.75 25 40

Wall and Ceiling Grilles

www.air-diffusion.co.uk 25

Page 26: Air Diffusion - WallandCeilingGrills

Model NB Narrow Blade Bar Grille

DescriptionModel NB narrow blade bar type grilleincorporates a 3.5mm wide blade on a12.5mm pitch. The blades are offered in 3separate deflection angles, 0°, 15° or 30°and may be either horizontal or vertical.The core assembly can be supplied eitherfixed or removable. Four frame sizes areavailable, 20mm, 25mm, 32mm and44mm. The grille is suitable for sidewall,soffit or cill mounting and may be used forsupply or extract applications.Typicalinstallations include offices, shops, hotels,sports halls and most commercial orindustrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyesterpowder coat finishes are also available asan option.

Standard fixing for flange sizes 25mm,32mm and 44mm is with No. 6countersunk headed screws (BYOTHERS) using prepared countersunkscrew holes in the flange. For flange size20mm either secret fixing (F6) or springclip fixing (F2) is used. A total of 8alternative installation methods areavailable, although spring clip fixing (F2) isnot recommended for high sidewall orceiling installation.

An optional opposed blade damper canbe fitted to the rear of the grille, which isadjusted through the grille core.

Specification

Material

Extruded aluminium sections.

Construction20mm, 25mm, 32mm or 44mm wideflange frame with corners mitred andwelded. Fixed blades are 3.5mm wide ona 12.5mm pitch and secured into theframe by 8mm tubular mullions on amaximum of 350mm centres.

Installation Methods

F0 – No fixing (fixing BY OTHERS).

F1 – Countersunk Screw Holes in Flange,Standard (25mm, 32mm & 44mm flange).

F2 – Spring Clips, (not recommended forceiling or high sidewall installation).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS).

F8 – Ceiling Alignment Clip, details ofceiling type and clip to be provided.

For Installation Guide see Pages 37/38.

Accessories

Available fitted with opposed bladedamper adjusted through the grille core.

Removable core, spring terry clip.

Finish

0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powdercoat.

3 – White (RAL9010) 20% polyesterpowder coat (Standard).

4 – Black (RAL9005) polyester powder coat.

5 – Brushed (Linished) natural aluminiumface surfaces, 20mm and 32mm frameonly.

6 – Special polyester powder coat (Please state separately the RAL colourreference and finish type required).

Model Types

Model NB0-G is supplied as a grille onlywith 0° deflection, 3.5mm blades on12.5mm pitch.

Model NB15-G is supplied as a grille onlywith 15° deflection, 3.5mm blades on12.5mm pitch.

Model NB30-G is supplied as a grille onlywith 30° deflection, 3.5mm blades on12.5mm pitch.

A prefix of 20W, 25W, 32W or 44Wdetermines the flange width (ie. Modeltype 25W-NB15-G is a grille only with25mm wide flange and 15 degreedeflection blades).

For an opposed blade damper replacethe letter ‘G’ with the letter ‘R’ (ie. Modeltype 25W-NB15-R is a grille having a25mm wide flange, 15 degree deflectionblades and fitted with an opposed bladedamper).

DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1800mm x1200mm. Special sizes also available.

Model 20W NB0 - 0° Deflection No. 2finish

Model 20W NB15 - 15° Deflection No. 3finish

Model 20W NB30 - 30° Deflection No. 2finish

Wall and Ceiling Grilles

26 www.air-diffusion.co.uk

Page 27: Air Diffusion - WallandCeilingGrills

Model GN Narrow Blade Bar Grille

DescriptionModel GN narrow blade bartype grille incorporates a3.5mm wide blade on a19mm pitch. The blades areoffered in 3 separatedeflection angles, 0°, 15° or30° and may be eitherhorizontal or vertical. The coreassembly can be suppliedeither fixed or removable.Four frame sizes are available,20mm, 25mm, 32mm and44mm. The grille is suitablefor sidewall, soffit or cillmounting and may be usedfor supply or extractapplications.Typicalinstallations include offices,shops, hotels, sports hallsand most commercial orindustrial buildings.

Available as standard in white

polyester powder coat finishOther polyester powder coatfinishes are also available asan option.

Standard fixing for flangesizes 25mm, 32mm and44mm is with No. 8countersunk headed screws(BY OTHERS) using preparedcountersunk screw holes inthe flange. For flange size20mm either secret fixing (F6)or spring clip fixing (F2) isused. A total of 6 alternativeinstallation methods areavailable, although spring clipfixing (F2) is notrecommended for highsidewall or ceiling installation.

An optional opposed bladedamper can be fitted to the rearof the grille, which is adjustedthrough the grille core.

Specification

Material

Extruded aluminium sections.

Construction20mm, 25mm, 32mm or44mm wide flange frame withcorners mitred and welded.Fixed blades are 3.5mm wideon a 19mm pitch and securedinto the frame by 8mm tubularmullions on a maximum of350mm centres.

Installation Methods

F0 – No fixing (fixing BYOTHERS).

F1- Countersunk Screw Holesin Flange, Standard (25mm,32mm and 44mm flange).

F2 – Spring Clips, Standard(20mm flange) (notrecommended for ceiling orhigh sidewall installation).

F4 – Rear strap (concealedbehind grille core) matingstrap BY OTHERS.

F6 – Rear strap and Mating“U” bracket (requires hemmedduct BY OTHERS).

F8 – Ceiling Alignment Clip,details of ceiling type and clipto be provided.

For Installation Guide seePages 37/38.

AccessoriesAvailable fitted with opposedblade damper adjustedthrough the grille core.

Removable core, spring terryclip.

Finish

0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyesterpowder coat.

3 – White (RAL9010) 20%polyester powder coat(Standard).

4 – Black (RAL9005) polyesterpowder coat.

5 – Brushed (Linished) naturalaluminium face surfaces,20mm and 32mm frame only.

6 – Special polyester powdercoat finish (Please stateseparately the RAL colourreference and finish typerequired).

Model Types

Model GN0-G is supplied asa grille only with 0° deflection,3.5mm blades on 19mmpitch.

Model GN15-G is supplied asa grille only with 15°deflection, 3.5mm blades on19mm pitch.

Model GN30-G is supplied asa grille only with 30°deflection, 3.5mm blades on19mm pitch.

A prefix of 20W, 25W, 32W or44W determines the flangewidth (i.e. Model type 25W-GN15-G is a grille only with25mm wide flange and 15degree deflection blades).

For an opposed bladedamper replace the letter ‘G’with the letter ‘R’ (ie. Modeltype 25W-GN15-R is a grillehaving a 25mm wide flange,15 degree deflection bladesand fitted with an opposedblade damper).

DimensionsMinimum size is 100mm x100mm up to a maximumsingle section of 1800mm x1200mm. Special sizes alsoavailable.

Dimensions see drawings onpages 30 and 31.

Model 44W GN0 - 0° Deflection – No. 2 finish, with corner detail.

Model 44W GN15 - 15° Deflection – No. 2 finish, with corner detail.

Model 44W GN30 - 30° Deflection – No. 3 finish, with corner detail.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 27

Page 28: Air Diffusion - WallandCeilingGrills

Model WB Wide Blade Bar Grille

Description

Model WB wide blade bar type grilleincorporates a 6.5mm wide blade on a14mm pitch. The blades are offered in 2separate deflection angles, 0° or 15° andmay be either horizontal or vertical. Thecore assembly can be supplied eitherfixed or removable. Four frame sizes areavailable, 20mm, 25mm, 32mm and44mm. The grille is suitable for sidewall,soffit or cill mounting and may be used forsupply or extract applications. Typicalinstallations include offices, shops, hotels,sports halls and most commercial orindustrial buildings.

Available as standard in white polyesterpowder coat finish Other polyesterpowder coat finishes are also available asan option.

Standard fixing for flange sizes 25mm,32mm and 44mm is with No. 8countersunk headed screws (BYOTHERS) using prepared countersunkscrew holes in the flange. For flange size20mm either secret fixing (F6) or springclip fixing (F2) is used. A total of 8alternative installation methods areavailable, although spring clip fixing (F2) isnot recommended for high sidewall orceiling installation.

An optional opposed blade damper canbe fitted to the rear of the grille, which isadjusted through the grille core.

Specification

Material

Extruded aluminium sections

Construction20mm, 25mm, 32mm or 44mm wideflange frame with corners mitred andwelded. Fixed blades are 6.5mm wide ona 14mm pitch and secured into the frameby 8mm tubular mullions on a maximum

of 350mm centres.

Installation Methods

F0 – No fixing (fixing BY OTHERS).

F1 – Countersunk Screw Holes in Flange,Standard (25mm, 32mm and 44mmflange).

F2 – Spring Clips, Standard (20mmflange) (not recommended for ceiling orhigh sidewall installation)

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracketrequires hemmed duct BY OTHERS).

F8 – Ceiling Alignment Clip, details ofceiling type and clip to be provided.

F10 – Removable core, spring terry clip.

For Installation Guide see Pages 37/38.

AccessoriesAvailable fitted with opposed bladedamper adjusted through the grille core.

Removable Core, spring terry clip.

Finish

0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powdercoat.

3 – White (RAL9010) 20% gloss polyesterpowder coat. (Standard)

4 – Black (RAL9005) polyester powdercoat.

5 – Brushed (Linished) natural aluminiumface surfaces, 20mm and 32mm frameonly.

6 – Special polyester powder coat finish(Please state separately the RAL colourreference and finish type required).

Model Types

Model WB0-G is supplied as a grille onlywith 0° deflection, 6.5mm blades on14mm pitch.

Model WB15-G is supplied as a grilleonly with 15° deflection, 6.5mm bladeson 14mm pitch.

A prefix of 20W, 25W, 32W or 44Wdetermines the flange width (ie. Modeltype 25W-WB15-G is a grille only with25mm wide flange and 15 degreedeflection blades).

For an opposed blade damper replacethe letter ‘G’ with the letter ‘R’ (ie. Modeltype 25W-WB15-R is a grille having a25mm wide flange, 15 degree deflectionblades and fitted with an opposed bladedamper).

DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1800mm x1200mm. Special sizes also available.

See drawings on pages 30 and 31.

Model 25W WB0 - 0° Deflection No. 3 finish.

Model 25W WB15 - 15° Deflection No. 3 finish.

Model 32W WB0 - 0° Deflection No. 2 finish.

Wall and Ceiling Grilles

28 www.air-diffusion.co.uk

Page 29: Air Diffusion - WallandCeilingGrills

Model GW Wide Blade Grille

Description

Model GW wide blade bar type grilleincorporates a 6.5mm wide blade on a19mm pitch. The blades are offered in 2separate deflection angles, 0° or 15° andmay be either horizontal or vertical. Thecore assembly can be supplied eitherfixed or removable. Four frame sizes areavailable, 20mm, 25mm, 32mm and44mm. The grille is suitable for sidewall,soffit or cill mounting and may be used forsupply or extract applications. Typicalinstallations include offices, shops, hotels,sports halls and most commercial orindustrial buildings.

Available as standard in white polyesterpowder coat finish. Other polyester powdercoat finishes are also available as an option.

Standard fixing for flange sizes 25mm,32mm and 44mm is with No. 8countersunk headed screws (BYOTHERS) using prepared countersunkscrew holes in the flange. For flange size20mm either secret fixing (F6) or springclip fixing (F2) is used. A total of 8alternative installation methods areavailable, although spring clip fixing (F2) isnot recommended for high sidewall orceiling installation.

An optional opposed blade damper canbe fitted to the rear of the grille, which isadjusted through the grille core.

Specification

Material

Extruded aluminium sections.

Construction20mm, 25mm, 32mm or44mm wideflange frame with corners mitred andwelded. Fixed blades are 6.5mm wide ona 19mm pitch and secured into the frameby 8mm tubular mullions on a maximumof 350mm centres.

Installation MethodsF0 – No fixing (fixing BY OTHERS).

F1 – Countersunk Screw Holes in Flange,Standard (25mm, 32mm & 44mm flange).

F2 – Spring Clips, Standard (20mmflange) (not recommended for ceiling orhigh sidewall installation).

F4 – Rear strap (concealed behind grillecore) mating strap BY OTHERS.

F6 – Rear strap and Mating “U” bracket(requires hemmed duct BY OTHERS).

F8 – Ceiling Alignment Clip, details ofceiling type and clip to be provided.

F10 – Removable core, spring terry clip.

For Installation Guide see Pages 37/38.

Accessories

Available fitted with opposed bladedamper adjusted through the grille core.

Removable Core.

Finish

0 – Mill extruded aluminium.

2 – Silver (RAL9006) polyester powder coat.

3 – White (RAL9010) 20% gloss polyesterpowder coat (Standard).

4 – Black (RAL9005) polyester powder coat.

5 – Brushed (Linished) natural aluminiumface surfaces. 32mm frame only.

6 – Special polyester powder coat finish.(Please state separately the RAL colourreference and finish type required).

Model Types

Model GW0-G is supplied as a grille onlywith 0° deflection, 6.5mm blades on19mm pitch.

Model GW15-G is supplied as a grilleonly with 15° deflection, 6.5mm bladeson 19mm pitch.

A prefix of 20W, 25W, 32W or 44Wdetermines the flange width (ie. Modeltype 25W-GW15-G is a grille only with25mm wide flange and 15 degreedeflection blades).

For an opposed blade damper replacethe letter ‘G’ with the letter ‘R’ (ie. Modeltype 25W-GW15-R is a grille having a25mm wide flange, 15 degree deflectionblades and fitted with an opposed bladedamper).

DimensionsMinimum size is 100mm x 100mm up toa maximum single section of 1800mm x1200mm. Special sizes also available.

Model 25W GW0 - 0° Deflection No. 2 finish.

Model 44W GW15 - 15° Deflection No. 3 finish.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 29

Page 30: Air Diffusion - WallandCeilingGrills

Dimensions

20mm Border Not available with Flange Fixing Holes

25mm Border

36.5mm 72.5mm

20m

m20

mm

Nom

inal S

ize =

Open

ing S

ize

20W - NB0 - G 20W - NB15-R 20W - NB30-G 20W - WB0-R 20W - WB15-G

2

Cor

e S

ize

=N

omin

al –

19

Opposed blade volume control damper

Opposed blade volume control damper

38.5mm

25m

m25

mm

74.5mm

25W - NB0 - G 25W - NB15-R 25W - NB30-G 25W - WB0-R 25W - WB15-G

C

Nom

inal S

ize =

Open

ing S

ize

Cor

e S

ize

=N

omin

al –

19

Opposed blade volume control damper

Opposed blade volume control damper

Wall and Ceiling Grilles

30 www.air-diffusion.co.uk

Page 31: Air Diffusion - WallandCeilingGrills

Ove

rall

Siz

e =

Nom

inal

Siz

e +

45

Cor

e S

ize

= N

omin

al S

ize

–19

2525

19

Ove

rall

Siz

e =

Nom

inal

Siz

e +

45

Cor

e S

ize

= N

omin

al S

ize

–19

2525

38.5 74.5

19

Opposed Blade Volume Control Damper

Nom

inal

Siz

e =

Ope

ning

Siz

e

Nom

inal

Siz

e =

Ope

ning

Siz

e

25W GNO - G 25W GNO - R

32mm Border

25mm Border Model GN

Dimensions

36.5mm32

mm

32m

m72.5mm

32W - NB0 - G 32W- NB15-R 32W - NB30-G 32W - WB0-G 32W - WB15-G

Nom

inal S

ize =

Open

ing S

ize

Cor

e S

ize

=N

omin

al –

19

Opposed blade volume control damper

Opposed blade volume control damper

Wall and Ceiling Grilles

www.air-diffusion.co.uk 31

Page 32: Air Diffusion - WallandCeilingGrills

Dimensions

4419

Ove

rall

Siz

e =

Nom

inal

Siz

e +

83

Cor

e S

ize

= N

omin

al S

ize

–19

75.5

44W - GN0 - R

4419

Ove

rall

Siz

e =

Nom

inal

Siz

e +

83

Cor

e S

ize

= N

omin

al S

ize

–19

38.5

44W - GN0 - G

44mm Wide Border Model GN

Wall and Ceiling Grilles

32 www.air-diffusion.co.uk

Page 33: Air Diffusion - WallandCeilingGrills

1. Determine air volume flow rate per outlet.

2. If a supply application, establish available throw – use Selection Nomogram.

3. Establish required maximumnoise and pressure values for exhaust - use Selection Nomogram

4. With a straight edge line across from the litres per second value through valueswithin the maximum parameters established to the pivot line.

5. Retaining the position of intersection at the pivot line,pivot the straight edge until it meets acceptable values of size to its left and right.

Note:The pivot line represents an areaand by maintaining position onthis line, widths and heights canbe selected of equal area. Seenote regarding effect of aspectratio on throw for supplyapplications.

Free Space SupplyIn free space horizontaldischarge applications, thedirection of the air will bedependant on the relativetemperature of the primary air toambient. This can causeunsatisfactory conditioning ofthe occupied zone and in somecases vertical discharge down orup walls is a more suitableapproach. (Please refer to thechart showing the effect oftemperature and surface tovertical discharge. Fig.1).

Throw is reduced in free spacewhere there is no ceiling effect orother surface proximity and thereduction for isothermalconditions is 30% from thefigures given on the nomogram.

For primary air above or belowambient the throw measuredhorizontally is affected by themass and temperature. Fig. 2illustrates typical centre of jet airpatterns, at the same mass anddifferent temperatures.

Aspect RatioFrom the points above it is clearthat throw is a complex derivedvalue and another factor whichhas an effect is the aspect ratioor proportion of the largestnominal dimension to thesmallest.

Nomogram figures can be takenfor aspect ratios from 1:1 to 2:1but if the aspect ratio is greater,then the following factors can beapplied:

3:1 Reduce throw by 5%4:1 Reduce throw by 8%5:1 Reduce throw by 12%

Fig. 1

Vertically discharging airstreams areaffected by temperature and theresulting density difference betweenthe discharging air and ambient air.Throw is also affected by theproximity of surfaces. Use the graphopposite to provide a correctionfactor to apply to catalogue throws.

Note: The relative temperature values are based on downward discharge - for upward discharge reverse the heating and cooling effect.

Performance GuideJet Characteristics

LCurve Reference

X L = Up to 0.5m

Y L = More than 2.0m

1.5

1.25

1.00.90.80.7

0.6

0.5

0.4

0.3

0.25

Thr

ow

Fac

tor

(Cat

alog

ue th

row

x fa

ctor

= c

orre

cted

thro

w)

–14 –12 –10 – 8 –6 – 4 –2 0 2 4 6 8 10 12 14 16

Temperature Difference °C

Cooling – Heating+

Curve X

Curve Y

The Effect of Temperature on Vertical Discharge

Isothermal Throw

Throw at +10° C or –10° C

Throw at +5° C or – 5° C

The Effect of Temperature on Free Space Jets

Temperatures are in relation to space ambient

Wall and Ceiling Grilles

www.air-diffusion.co.uk 33

Page 34: Air Diffusion - WallandCeilingGrills

34 www.air-diffusion.co.uk

1. Determine air volume flowrate per outlet.

2. If GNO or GWO supplyapplication, establishavailable throw.

3. Establish require maximumnoise and pressure values -refer to the appropriatenomogram

4. With a straight edge lineacross from the litres persecond value through values within the maximumparameters established tothe pivot line.

5. Retaining the position ofintersection at the pivot line, pivot the straight edgeuntil it meets acceptablevalues of size to its leftand right.

Note:The pivot line represents an areaand by maintaining position on thisline widths and heights can beselected of equal area. See noteregarding effect of aspect ratio onthrow for supply applications.

Please refer to additional note onPage 1 regarding air jetcharacteristics under variousconditions.

ThrowThrows shown in the catalogueare based on horizontaldischarge of cooled air with fullattachment of the jet to a flatceiling close enough above thegrille position to enable thiscondition to occur. For mostcases for ceiling effect the grillewould be positioned no morethan 300mm below the ceiling.

Core area (m2) - Preferred Sizes

Nominal

Height Nominal Width - mm

mm 150 200 250 300 350 400 500 600 700 800 900 1000 1100 1200

100 .0077 .0110 .0143 .0176 .0209 .0242 .0308 .0374 .0440 .0506 .0572 .0638 .0704 .0770

150 .0136 .0193 .0251 .0309 .0367 .0425 .0541 .0657 .0773 .0889 .1005 .1121 .1237 .1353

200 .0276 .0359 .0442 .0525 .0608 .0774 .0940 .1106 .1272 .1438 .1604 .1770 .1936

250 .0467 .0574 .0683 .0791 .1007 .1223 .1439 .1655 .1871 .2087 .2303 .2519

300 .0708 .0841 .0974 .1240 .1506 .1772 .2038 .2304 .2570 .2836 .3102

400 .1340 .1706 .2072 .2438 .2804 .3170 .3536 .3902 .4268

500 .2172 .2638 .3104 .3570 .4036 .4502 .4968 .5434

600 .3204 .3770 .4336 .4902 .5468 .6034 .6600

Pressure LossThe total pressure lossesgiven are for grilles withdampers fitted with thedampers fully open. A 10%reduction of the value can betaken for grilles withoutdampers.

Sound LevelsWherever possible we give NRpower levels generated by theproduct. This enables theallowances for roomcharacteristics, surfacemounting and multiple outletsfrom the sound advice leafletto be taken into account andmore accurately predict thesound pressure measured inthe occupied space.

The NR power level givenincludes for a fully opendamper. For grilles withoutdampers 2dB can besubtracted. However, theeffect of partly closing thedamper for balancingpurposes can add significantlyto generated noise.

Free Area Factors:GNO = 0.85GWO = 0.70Based on 300 x 300 nominal size, the figures above mayvary by 5% dependent on grille size.

Performance Guide

Selection Procedure Notes to Selection Data

Wall and Ceiling Grilles

34 www.air-diffusion.co.uk

Page 35: Air Diffusion - WallandCeilingGrills

1500

1200

1000900

800

700

600

500

400

300

250

200

150

100

50

40

30

20

20

15

10

9

8

7

6

5

4

3

2

15

10

9

8

7

6

5

4

3

2

1

40

50

75

100

125

150

175

200

225

250

275

300

350

400

Values shown are forModel WB. For NBapply correction factorsas shown.

55

50

45

40

35

30

25

20

54

3

2

1.5

1

0.5

0.25

50

30

20

10

5

All values include for fittedopposed blade dampers.

Throw based on 10° cooling toterminal velocity of 0.25m/s.

Side wall throw assumes flatceiling not more than 0.5mabove grille centre line.

VOLU

ME

Litre

s s/

m

SID

EWA

LL

FLO

OR

TO

CIL

L

THR

OW

m

SO

UN

D P

OW

ER L

EVEL

NR

LW

DU

CT

VELO

CIT

Y m

/s

TOTA

L P

RES

SU

RE

Pa

SIZ

E m

m

Models NB, WB – Nomogram

NB Correction Factors

Throwx 0.8

Sound Power– 2dB

Throwx 0.8

Wall and Ceiling Grilles

www.air-diffusion.co.uk 35

Page 36: Air Diffusion - WallandCeilingGrills

Sound power and pressurelevels are based on GNOwith dampers fully open. For GWO refer to table.Refer to selection procedurefor details.

3000

2500

2000

1500

1000

900

800

700

600

500

400

300

250

200

150

100

90

80

70

60

50

40

30

20

20

15

10

9

8

7

6

5

4

3

2

50

40

30

20

10

50

40

30

20

10

5

10

5

4

3

2

1

0.5

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1050

1100

1150

1200

100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1050

1100

1150

1200

VOLU

ME

- Li

tres/

s

THR

OW

MET

RES

10°

C C

oolin

g

NR

LW

SO

UN

D P

OW

ER L

EVEL

TOTA

L P

RES

SU

RE

Pa

(+50

% 4

0° D

efle

ctio

n)

DU

CT

VELO

CIT

Y m

/s

SIZ

E -

mm

PIV

OT

LIN

E

SIZ

E -

mm

GWO Correction Factors

Sound Power Levels+5dB

Pressure Levels+20%

Throw+20%

Models GNO and GWO – Nomogram

Wall and Ceiling Grilles

36 www.air-diffusion.co.uk

Page 37: Air Diffusion - WallandCeilingGrills

12

Mating strap by others

Rear strap fitted to grille

Mating strap by others

Rear strap fitted to grille

Type F1Standard face countersunk holes forscrew fixing.

Type F2Optional spring clips.

Note:For satisfactory fixing require accuratelyformed opening or duct with firm sides.Not suitable for ceiling or high sidewallinstallation.

Type F4Optional rear strap.

Note:Mating strap by others.

Type F6Optional rear strap plus mating ‘U’bracket.

Note:Hemmed duct by others or plenums byus.

Installation Guide

Type F8 - Ceiling Alignment Clip Fixing

(Details of ceiling system and clip to be supplied).

Wall and Ceiling Grilles

www.air-diffusion.co.uk 37

Page 38: Air Diffusion - WallandCeilingGrills

36.5

34.9

532

Terry clips

Terry clips

Terry clips

Side ViewTypical Clip Arrangement

Side ViewTypical Clip Arrangement

Side ViewTypical Clip Arrangement

36.5

5

Model 32W - NB30G - RC

Nom

inal

Siz

e

Core secured to matingstrap via PullsertM3.5 screw fixing(can be one off in centredepending on width)

Mating straps - 3/4 " x 1/8" Flat Bar

Ove

rall

Siz

e =

Nom

inal

+45

Mullion

30 Narrow Blade

3212

.5 c

rs

Removable Core Details

Spring Terry Clip Arrangement Suitable for use with Models G45 NB, GN, WB and GW

Pullsert Arrangements. Suitable for use with models NB, GN, WB and GW.

Wall and Ceiling Grilles

38 www.air-diffusion.co.uk

Page 39: Air Diffusion - WallandCeilingGrills

20W – 20mmflat surfaceflange havingmitred andweldedcorners.

20C – 20mmflat surfaceflange havingmitred andmechanicallycleatedcorners.

25W – 25mmflat surfaceflange havingmitred andweldedcorners.

25C - 25mmflat surfaceflange havingmitred andmechanicallycleatedcorners.

32W – 32mmflat surfaceflange havingmitred andweldedcorners.

44W – 44mmwide flatsurface flangehaving mitredand weldedcorners (ModelEC only).

Ordering Information

Flange Style Model Damper Fixing Finish Size25W CB2L R F0 3

Example

G – Grille only.

R – Grille with OBDfitted.

Width xHeight

F0 – No fixing(fixing BYOTHERS).

F1 - CountersunkScrew Holes inFlange (Standard).

F2 - Spring Clips(not recommendedfor ceiling or highsidewallinstallation).

F4 – Rear strap(concealed behindgrille core) matingstrap BY OTHERS.

F6 – Rear strapand Mating ‘U’bracket (requireshemmed duct BYOTHERS).

F8 – Ceilingalignment clip.(Note: details ofceiling type and clipmust be provided).

F10 – Removablecore spring terryclip.

0 – Mill extrudedaluminium.

2 – Silver (RAL9006)polyester powdercoat.

3 – White (RAL9010)20% polyesterpowder coat.

4 – Black (RAL9005)polyester powdercoat.

5 – Brushed(Linished) naturalaluminium facesurfaces, 32 mmframe only.

6 – Special polyesterpowder coat finish.(Please stateseparately the RALcolour reference andfinish type required).

Important Note: If the overall size iscritical then it must be clearly stated onthe order. All orders must be addressedto AIR DIFFUSION, Ruskin AirManagement Limited.

Wall and Ceiling Grilles

www.air-diffusion.co.uk 39

Curved Blade Ceiling Grilles25W, 25C CB1L curved blade ceiling grille having 1 way air pattern with blades running parallel to the longest side.

25W, 25C CB1S curved blade ceiling grille having 1 way air pattern with blades running parallel to the shortest side.

25W, 25C CB2L curved blade ceiling grille having 2 way air pattern with blades running parallel to the longest side.

25W, 25C CB2S curved blade ceiling grille having 2 way air pattern with blades running parallel to the shortest side.

25W, 25C CB2S (LH) curved blade ceiling grille having a 2 way corner air pattern with 1 set of blades running parallel to the shortest side and 1 set at right angles left handed.

25W, 25C CB2S (RH) curved blade ceiling grille having a 2 way corner air pattern with 1 set of blades running parallel to the shortest side and 1 set at right angles right handed.

25W, 25C CB3L curved blade ceiling grille having 3 way air pattern with outer blades running parallel to the longest side.

25W, 25C CB3S curved blade ceiling grille having 3 way air pattern with outer blades running parallel to the shortest side.

25W, 25C CB3S (EQ) curved blade ceiling grille having a 3 way air pattern with the 2 outer blade sets running parallel to the shortest side with an equal size 3rd set located in the centre.

25W, 25C CB4L curved blade ceiling grille having 4 way air pattern with outer blades running parallel to the longest side.

25W, 25C CB4S curved blade ceiling grille having 4 way air pattern with outerblades running parallel to the shortest side.

Single Deflection Grilles

25W, 25C SDH single deflection grille with a one set of horizontal blades.

25W, 25C SDV single deflection grille with a one set of vertical blades.

Double Deflection Grilles

25W, 25C DDH double deflection grille with one set of front horizontal and one set of rear vertical blades.

25W, 25C DDV double deflection grille with one set of front vertical and one set of rear horizontal blades.

Egg Crate Grille

25W, 25C 44W ECG egg crate grille with a fixed core.

25W, 25C ECG-RC egg crate grille with a removable core.

Perforated Grille

25W, 25C 44W PG perforated grille with a fixed core.

45° Fixed Blade

25W, 25C 44W FBG45 45° fixed blade grille with a 1 way core. (State separately if 2 way core required).

Non Vision Grille

25W, 25C NVG non-vision grille.

25W, 25C NVG-MF non-vision grille with a standard matching flange.

25W, 25C NVG-DF non-vision grille with a deep matching flange.

Bar Grilles

20W, 20C, 25W, 25C, 32W, 44W NB0 narrow blade bar grille having 0° deflection, 3.5mm blade on 12.5mm pitch.

20W, 20C, 25W, 25C, 32W, 44W NB15 narrow blade bar grille having 15° deflection, 3.5mm blade on 12.5mm pitch.

20W, 20C, 25W, 25C, 32W, 44W NB30 narrow blade bar grille having 30° deflection, 3.5mm blade on 12.5mm pitch.

20W, 20C, 25W, 25C, 32W, 44W GN0 narrow blade bar grille having 0° deflection, 3.5mm blade on 19mm pitch.

20W, 20C, 25W, 25C, 32W, 44W GN15 narrow blade bar grille having 15° deflection, 3.5mm blade on 19mm pitch.

20W, 20C, 25W, 25C, 32W, 44W GN30 narrow blade bar grille having 30° deflection, 3.5mm blade on 19mm pitch.

20W, 20C, 25W, 25C, 32W, 44W WB0 wide blade bar grille having 0° deflection, 6.5mm blade on 14mm pitch.

20W, 20C, 25W, 25C, 32W, 44W WB15 wide blade bar grille having 15° deflection, 6.5mm blade on 14mm pitch.

20W, 20C, 25W, 25C, 32W, 44W WB30 wide blade bar grille having 30° deflection, 6.5mm blade on 14mm pitch.

20W, 20C, 25W, 25C, 32W, 44W WB15 wide blade bar grille having 15° deflection, 6.5mm blade on 14mm pitch.

20W, 20C, 25W, 25C, 32W, 44W GW0 wide blade bar grille having 0° deflection, 6.5mm blade on 19mm pitch.

20W, 20C, 25W, 25C, 32W, 44W GW15 wide blade bar grille having 15° deflection, 6.5mm blade on 19mm pitch.

Fixed and Removable Core - Bar Grilles Only.To denote a Fixed Core bar grille FC must be added to the Model type (e.g. NB0FC) alternatively to denote a removable core bargrille RC must be added to the Model type (e.g. NB0RC).

Page 40: Air Diffusion - WallandCeilingGrills

Slot and Fixed Blade Diffusers

Floor Grilles

Cylinder and Jet Nozzle Diffusers

Product Range

Swirl, Displacement and High Induction Diffusers

Perforated and Louvre Face Ceiling Diffusers

Circular Diffusers and AirValves

Wall and Ceiling Grilles

40 www.air-diffusion.co.uk

Page 41: Air Diffusion - WallandCeilingGrills

Product Range

External Louvres

Miscellaneous

Linear Grilles Wall and Ceiling Grilles

● Swirl, Displacement and High InductionDiffusers

● Perforated and Louvre Face Ceiling Diffusers

● Slot and Fixed Blade Linear Diffusers

● Cylinder and Jet Nozzle Diffusers

● Circular Diffusers and Air Valves

● Floor Grilles

● Linear Bar Grilles

● Grilles

● External Louvres

● Miscellaneous

Wall and Ceiling Grilles

www.air-diffusion.co.uk 41

Page 42: Air Diffusion - WallandCeilingGrills

Part of Ruskin Air Management Limited

Wall and Ceiling Grilles

Ruskin Air Management Limitedis a BS EN ISO 9000 registeredcompany.

The statements made in this brochure or by ourrepresentatives in consequence of any enquiriesarising out of this document are given for informationpurposes only. They are not intended to have anylegal effect and the company is not to be regardedas bound thereby. The company will only acceptobligations which are expressly negotiated for andagreed and incorporated into a written agreementmade with its customers.

Due to a policy of continuous product developmentthe specification and details contained herein aresubject to alteration without prior notice.

Comprehensive and detailed informationis available for all Air Diffusion products.Visit our website at www.air-diffusion.co.uk

Stourbridge Road, Bridgnorth, Shropshire,WV15 5BB England.Tel: 01746 761921 Fax: 01746 760127 Email: [email protected]: www.air-diffusion.co.uk

Ruskin Air Management Limited