Air Conditioning AIR CONDUCTING FAN PRODUCT FLYER

Transcript of Air Conditioning - Mitsubishi Electric€¦ · Terminal box Unit (mm) 152 74 910 100 210 390 Power...

Page 1: Air Conditioning - Mitsubishi Electric€¦ · Terminal box Unit (mm) 152 74 910 100 210 390 Power cable Effective length1m 130 220 4-12x40 mounting hole Air flow 297 210 292 1110

Air ConditioningAIR CONDUCTING FANPRODUCT FLYER

Page 2: Air Conditioning - Mitsubishi Electric€¦ · Terminal box Unit (mm) 152 74 910 100 210 390 Power cable Effective length1m 130 220 4-12x40 mounting hole Air flow 297 210 292 1110

Installation Examples for Large Spaces

Air Conducting Fans are supporting equipment for ventilators and air conditioners to move exhaust gas in car parks and help to improve the efficiency of ventilation or air conditioning in factories and warehouses.

Car Parks: Removing exhaust gasAir Conducting Fans are particularly useful for moving and expelling stagnant, dirty exhaust gas and hot air that stagnates in the midsections of buildings with complicated floor plans.

Warehouses and Factories: Circulating cool airAir Conducting Fans help circulate air conditioned air; they improve the working environments by reducing temperature variations throughout large indoor spaces. They enhance the effectiveness of cooling over a wider area, and the airflow they generate creates a refreshing breeze.

Air Conducting FanAH SERIES

Page 3: Air Conditioning - Mitsubishi Electric€¦ · Terminal box Unit (mm) 152 74 910 100 210 390 Power cable Effective length1m 130 220 4-12x40 mounting hole Air flow 297 210 292 1110

Quiet and CompactThe compact axial fan (quiet propeller design) reduces noise level yet still makes it possible to achieve substantial airflow. The slim and lightweight design offers greater flexibility in your installation plans.

Low Power ConsumptionWith the compact and high-efficiency motor, and also the axial fan, Air Conducting Fan saves lots of energy.

Easy Installation The Air Conducting Fan can be easily installed by simply mounting it to suspension bolts on the ceiling. The angle of the air vent is adjustable to six levels.

Air Velocity Distribution

Air Conducting Fans not in use Air Conducting Fans in use

More equipments and higher installation cost

Ductsystem

Less equipments and lower installation cost

-

Ductlesssystem

0ppm

100ppm

Low

High

*Thermal distribution graphic for reference only. Actual results may differ.

Air Conducting Fans in use

Air Conducting Fans not in use

More equipments and higher installation cost

Ductsystem

Less equipments and lower installation cost

-

Ductlesssystem

0ppm

100ppm

Low

High

Temperature Distribution Using Air Conducting Fans help the air conditioned air to reach all corners, improving comfort levels.

CO DistributionThe airflow created by Air Conducting Fans allow fresh air to permeate all corners of a car park, while at the same time reliably directing the vehicle exhaust gas toward the exhaust fans.

²

LW

H

L5 - 1010 - 1515 - 2020 - 30

Model W4 - 65 - 76 - 87 - 9

AH-1006S-EAH-1509S-EAH-2009S-EAH-3009S-E

H2 - 43 - 64 - 8

5 - 10

There are cases where the reach distance is extended by angled venting, which causes the Wind to flow along the floor's surface.The Wind velocity distribution may be disturbed by enclosing walls, beams,pillars and other obstructions.Depending on conditions of the building, there may be difference in the spacingof units during installation.

AH-1006S-E

High speed

345

210

151050

0.3m/s0.5m/s1m/s

0.3m/s0.5m/s1m/s

3

321

210

150 5 10

345

2

01

3

321

210

0.3m/s0.5m/s1m/s

0.3m/s0.5m/s1m/s

Side view

Plan view

Dist

ance

from

cen

ter (

m)

Dist

ance

from

floo

r sur

face

(m)

Dist

ance

from

cen

ter (

m)

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)1050

Distance from air outlet (m)

Distance from air outlet (m)0 5 10

Distance from air outlet (m)

Side view

Plan view

Unit (mm)

Low speed

0.3m/s0.5m/s1m/s

0.3m/s0.5m/s1m/s

151050

150 5 10

345

210

3

321

210

Side view

Plan view

Dist

ance

from

cen

ter (

m)

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)

Distance from air outlet (m)

0.3m/s0.5m/s1m/s

1m/s 0.5m/s 0.3m/s

0 5 10

0 5 10

012

123

3

012

543

Side view

Plan view

Dist

ance

from

cen

ter (

m)

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)

Distance from air outlet (m)

0.3m/s0.5m/s1m/s

200 5 10 15012

543

Side view

Plan view

0.3m/s0.5m/s1m/s

200 5 10 15

012

123

3

Dist

ance

from

cen

ter (

m)

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)

Distance from air outlet (m)

0.3m/s0.5m/s1m/s

0.3m/s0.5m/s1m/s

0 5 10 15

0 5 10 15012

543

012

123

3Plan view

Side view

Dist

ance

from

cen

ter (

m)

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)

Distance from air outlet (m)

AH-1509S-E

High speed Low speed

AH-2009S-E

High speed Low speed

AH-3009S-E

High speed Low speed

Plan view

Dist

ance

from

cen

ter (

m)

Distance from air outlet (m)0 10 20 30

3210123

1m/s 0.5m/s 0.3m/s

Side view

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)0 10 20 30

6543210

1m/s 0.5m/s 0.3m/s

Plan view

Dist

ance

from

cen

ter (

m)

Distance from air outlet (m)0 10 20 30

3210123

1m/s 0.5m/s 0.3m/s

Side view

Dist

ance

from

floo

r sur

face

(m)

Distance from air outlet (m)0 10 20 30

6543210

1m/s 0.5m/s 0.3m/s

Page 4: Air Conditioning - Mitsubishi Electric€¦ · Terminal box Unit (mm) 152 74 910 100 210 390 Power cable Effective length1m 130 220 4-12x40 mounting hole Air flow 297 210 292 1110

* The mounting angle of the unit body can be adjusted in 8 steps. (0, 11.3, 22.5, 33.8, 45, 56.3, 67.5, 90°)

Attachment details

*Figures in parentheses is the value of the AH-1509S-E and AH-2009S-E.

Internal attachment pitch

External attachment pitch

489(789)

525(825)

680(980)

716(1016)

100

12

137

58

7

600(900)

80 130

197

15380

256

190

223

Air flow

Terminal box

Unit (mm)

152

74

910

100

210

390

Power cableEffective length 1m

130

4-12x40mounting hole

Air flow

297

220

292

210

1110

1032

794

716

* The mounting angle of the unit body can be adjusted in 8 steps. (0, 11.3, 22.5, 33.8, 45, 56.3, 67.5, 90°)

AH-1006/1509/2009S-E AH-3009S-E

Specifications

Model Fan Speed

Single-phase, 50Hz 220-240VStarting

Current (A)Weight (kg)

Dimensions (HxWxD)

mmAir Volume (m³/h)

Running Current (A)

Input Power (W)

Air Velocity Max. (m/sec)

Noise (dB)

AH-1006S-EHigh 700-750 0.14-0.15 30-34 6.5-6.9 42-44

0.23 7 190x600x197Low 570-620 0.13-0.13 28-32 5.3-5.7 39-40

AH-1509S-EHigh 1180-1270 0.26-0.26 55-62 7.3-7.8 43.5-45

0.43 10.5 190x900x197Low 940-1040 0.24-0.25 51.5-59 5.8-6.4 39-41.5

AH-2009S-EHigh 1350-1400 0.43-0.47 90-105 8.3-8.6 46.5-47.5

0.85 11 190x900x197Low 1130-1200 0.36-0.37 77-87 7.0-7.4 44-46

AH-3009S-EHigh 2100 0.87-0.94 191-223 8.2 58-58 2.53

20.5 210x910x220Low 1860 0.74-0.75 150-165 7.3 55.5-56 1.55