Ceiling sensors descriptionThe dual technology sensor’s combination of ultrasonic and passive infrared technologies offers the most complete sensing equipment available today. MicroSet self-adjusting dual technology sensors drastically simplify and reduce a contractor’s installation and adjustment time period.
Design features• MicroSet self-adjusting time delay and sensitivity• Products tested to NEMA WD 7 - 2011 Occupancy Motion
Sensors Standard• Built-in light level sensor (Low voltage only)• BAS/HVAC isolated relay (Low voltage only)• Selectable walk-through mode (Low voltage only)• Dual relay control (Low voltage only)• Units available for control of single or two separate loads
(Line voltage only)
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
AHAC-DT – MicroSet dual tech low/line voltage ceiling sensors
Catalog no. Coverage Field of view Frequency Features
AHAC-DT-2000 2000 sq. ft. Two way (360˚) 32 kHz -— AHAC-DT-1000 1000 sq. ft. Two way (360˚) 32 kHz — AHAC-DT-0501 500 sq. ft One way (180˚) 40 kHz — AHAC-STEM — — -— —
Catalog no. Coverage Field of view Frequency Features
AHAC-DT-2000-MV 2000 sq. ft. Two way (360˚) 32 kHz With daylight sensor
AHAC-DT-2000-DMV 2000 sq. ft. Two way (360˚) 32 kHz Dual relay with daylight sensor
AHAC-STEM — — -— —
Table 1. MicroSet dual tech - line voltage ceiling sensor
Table 2. MicroSet dual tech - low voltage ceiling sensor
AHAC-DT
AHSP20-MV
Compliances, specifications and availability are subject to change without notice.
Table 3. Heavy duty switchpackCatalog no. Description Features
AHSP20-MV* Heavy duty switchpack Capable of switching up to 20A
*For more information about switchpack visit our website at www.eaton.com/wiringdevices
Technical Data Effective September 2018
2 EATON www.eaton.com/wiringdevices
Table 4. Specifications
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
Compliances, specifications and availability are subject to change without notice.
Technical Data Effective September 2018
AHAC-DT – MicroSet dual tech low/line voltage ceiling sensor
The MicroSet self-adjusting technology continuously monitors multiple sub-frequencies in the event that if a continuous Doppler shift occurs, such as those created by airflow from an air duct, the sensor will identify the noise as continuous and then block it out of view at a select sub-frequency. It will continue to monitor other sub-frequencies for human motion. This avoids false-activation, while still maintaining the high level of sensitivity that is necessary for sensing minor motion in a changing environment. Separate concurrent time delays for both Passive Infrared and Ultrasonic technologies avoid false activations or deactivations. In Automatic ON Mode, the lights turn ON when a person enters the room.
Applications
Catalog no. AHAC-DT - low voltage series
Technology Passive Infrared (PIR) and Ultrasonic (US)Power Requirements Input
10-30 VDC from Greengate Switchpack or Greengate systemMaximum current needed is 25mA per sensor
OutputOpen collector output to switch up to ten Greengate SwitchpacksIsolated Form C Relay Ratings: 1A 30 VDC/V/AC
Time Delays Self-adjustable, 15 seconds/test (10 minutes Auto), or Selectable 5, 15, 30 minutes, or Zero Time Delay
Coverage 500, 1000, and 2000 sq. ft.Light Level Sensing 0 to 300 foot-candlesOperating Environment Temperature: 32°F - 104°F (0°C - 40°C)
Relative humidity: 20% to 90%, non-condensing(For indoor use only)
Housing Durable, injection molded housing. Polycarbonate resin complies with UL 94V-0
Size 1.42”H x 4.5”W (36.068mm x 114.3mm)Mounting Mounts directly to ceiling tile, to a 4” square box
and round mud ring or to 4” octagon boxLED Indicators Red LED for PIR detection; Green LED for
Ultrasonic detectionStandards FCC Compliant
cULus ListedRoHS Compliant
Table 5. Specifications
W (White)
W
White
Table 6. Color information
Catalog no. AHAC-DT - line voltage series
Technology Passive Infrared (PIR) and Ultrasonic (US)Power Requirements 120 to 347 V/AC, 50/60 Hz - Neutral required
120 V/ACIncandescent/Tungsten - 0 to 800W, 50/60 HzFluorescent/Ballast - 0 to 1200W, 50/60 HzMotor Load: 1/4 HP @ 125 V/AC230 V/ACFluorescent/Ballast - 0 to 1200W, 50/60 Hz277 V/ACFluorescent/Ballast - 0 to 2700W, 50/60 Hz347 V/ACFluorescent/Ballast - 0 to 1500W, 50/60 Hz
Time Delays Self-Adjusting, 15 seconds/test (10 minutes Auto), or Selectable 5, 15, 30 minutes
Coverage 2000 sq. ftLight Level Sensing 0 to 300 foot-candlesOperating Environment Temperature: 32°F - 104°F (0°C - 40°C)
Relative humidity: 20% to 90%, non-condensing(For indoor use only)
Housing Durable, injection molded housing. Polycarbonate resin complies with UL 94V-0
Size 1.42”H x 4.5”W (36.068mm x 114.3mm)Mounting Mounts directly to ceiling tile, to a 4” square box
and round mud ring or to 4” octagon boxLED Indicators Red LED for PIR detection; Green LED for
Ultrasonic detectionStandards FCC Compliant
cULus ListedRoHS Compliant
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
Wiring diagrams
Figure 1. AHAC-DT-2000 Model
AHAC-DT – MicroSet dual tech low/line voltage ceiling sensor
Technical Data Effective September 2018
3EATON www.eaton.com/wiringdevicesCompliances, specifications and availability are subject to change without notice.
Figure 2. Single relay - line voltage series
Load 1
Neutral
120-347 V/AC
Line
White Blue Black
Automatic Mode Operation:1. When sensor activates, load turns ON2. Loads turn OFF when sensortimes out
Load 1
Neutral
120-347 V/AC
Line
Blue White Black
Red Red
Load 2
Red leads are non-polorarity sensitive.
Automatic Mode Operation:1. When sensor activates, both loads turn ON2. Loads turn OFF when sensortimes out
Figure 3. Dual relay - line voltage series
Catalog no. AHAC-DT - line voltage series
Technology Passive Infrared (PIR) and Ultrasonic (US)Power Requirements 120 to 347 V/AC, 50/60 Hz - Neutral required
120 V/ACIncandescent/Tungsten - 0 to 800W, 50/60 HzFluorescent/Ballast - 0 to 1200W, 50/60 HzMotor Load: 1/4 HP @ 125 V/AC230 V/ACFluorescent/Ballast - 0 to 1200W, 50/60 Hz277 V/ACFluorescent/Ballast - 0 to 2700W, 50/60 Hz347 V/ACFluorescent/Ballast - 0 to 1500W, 50/60 Hz
Time Delays Self-Adjusting, 15 seconds/test (10 minutes Auto), or Selectable 5, 15, 30 minutes
Coverage 2000 sq. ftLight Level Sensing 0 to 300 foot-candlesOperating Environment Temperature: 32°F - 104°F (0°C - 40°C)
Relative humidity: 20% to 90%, non-condensing(For indoor use only)
Housing Durable, injection molded housing. Polycarbonate resin complies with UL 94V-0
Size 1.42”H x 4.5”W (36.068mm x 114.3mm)Mounting Mounts directly to ceiling tile, to a 4” square box
and round mud ring or to 4” octagon boxLED Indicators Red LED for PIR detection; Green LED for
Ultrasonic detectionStandards FCC Compliant
cULus ListedRoHS Compliant
Load “A”
Blue
Neutral
Hot
**Use black lead for 120 VAC Use orange lead for 277 VAC Cap unused lead.
Line
**H
ot
Whi
te
Blu
e
SWITCH-PACK
Black (Common)
Blue (Control-OCC)
Yellow (Control-Occ/Day)
Brown (Blue Control)
Red (10-30 VDC)
Brown/White (Yellow Control)Load “B”
Blue
Neutral
Hot
**Use black lead for 120 VAC Use orange lead for 277 VAC Cap unused lead.
Line
**H
ot
Whi
te
Blu
e
SWITCH-PACK
Black (Common)Blue (Control) Red (15 VDC)
Black (Common)Blue (Control)
Red (15 VDC)
Model GMDS - Load “B”(Normally OpenMomentary Switch)
Purple (Normally Closed)Gray (Isolated Relay Common)Orange (Normally Closed)
Model GMDS - Load “A”(Normally OpenMomentary Switch)
NOTES1. LOADS MAY BE ON SAMECIRCUIT OR DIFFERENTCIRCUIT OR VOLTAGES2. SP20-MV SWITCHPACK SHOWN.120/277 VAC 20AMP RATING.
*Wiring diagram for single sensor application.Visit our website for other wiring diagrams.
Manual Mode Operation:1. Switches are required to turn corresponding loads ON. 2. Loads turn OFF when sensor times out or with the switches.
Automatic Mode Operation:1. When sensor activates, bothloads turn on.2. Switches can be used to turn lights ON or OFF.3. If daylight sensor is enabled and light level is above setpoint, switchpack connected to yellow lead will not turn ON. Recommended Wire:18-3 AWG Stranded Wire non/shielded.
3. If daylight sensor is enabled and light level is above setpoint,switchpack connected to yellow lead will not turn load ON
Technical Data Effective September 2018
1 2 3 4 5 6 7 8 9 10 11 12
ON
Daylight Sensor Adjustment Ultrasonic Sensitivity Adjustment
PIR Detector
SweepOverrideLEDs Full/Half Logic HVAC/Tracking Zero Time Delay
Pot 1 - Blue (0-300 FC)
Ultrasonic
(-R model only)
Pot 2 - Green
NormalSwap
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
AHAC-DT – MicroSet dual tech low/line voltage ceiling sensor
Controls (Low voltage)
Coverage
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area mayvary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and roboticmethod were utilized to verify
coverage patterns.
Minor Motion, IR
Major Motion, IR
8.5 ft(2.59 m)
17 ft(5.18 m)
10 ft(3 m)
5 ft(1.5 m)
00 5 ft
(1.5 m)10 ft(3 m)
17 ft(5.18 m)
23 ft(7.01 m)
DT1k
9 ft(2.74 m)
0
12 ft(3.65 m)
20 ft(6.096m)
23 ft(7.01 m)
9 ft(2.74 m)
12 ft(3.65 m)
20 ft(6.096m)
3 ft(0.91)
15 ft(4.57 m)
15 ft(4.57 m)
AHAC-DT-0501 500 sq. ft.
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area mayvary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and roboticmethod were utilized to verify
coverage patterns.
Minor Motion, IR
Major Motion, IR0
23 ft(7.01 m)
5 ft(1.52 m)
0 5 ft(1.52 m)
32 ft(9.75 m)
32 ft(9.75 m)
12 ft(3.65 m)
16 ft(4.87 m)
15 ft(4.57 m)
23 ft(7.01 m)
15 ft(4.57 m)
8.5 ft(2.59 m)
0
12 ft(3.65 m)
16 ft(4.87 m)
20 ft(6.096m)
20 ft(6.096m)
10 ft(3 m)
10 ft(3 m)
3 ft(0.91)
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area mayvary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and roboticmethod were utilized to verify
coverage patterns.
Minor Motion, IR
Major Motion, IR
8.5 ft(2.59 m)
5 ft(1.52 m)
10 ft(3.05 m)
15 ft(4.57 m)
23 ft(7.01 m)
0
9 ft(2.74 m)
9 ft(2.74 m)
0
12 ft(3.65 m)
12 ft(3.65 m)
20 ft(6.096m)
20 ft(6.096m)
AHAC-DT-1000 1000 sq. ft.
AHAC-DT-2000/MV/DMV 2000 sq. ft.
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area mayvary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and roboticmethod were utilized to verify
coverage patterns.
Minor Motion, IR
Major Motion, IR
8.5 ft(2.59 m)
5 ft(1.52 m)
10 ft(3.05 m)
15 ft(4.57 m)
23 ft(7.01 m)
0
9 ft(2.74 m)
9 ft(2.74 m)
0
12 ft(3.65 m)
12 ft(3.65 m)
20 ft(6.096m)
20 ft(6.096m)
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area mayvary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and roboticmethod were utilized to verify
coverage patterns.
Minor Motion, IR
Major Motion, IR
8.5 ft(2.59 m)
5 ft(1.52 m)
10 ft(3.05 m)
15 ft(4.57 m)
23 ft(7.01 m)
0
9 ft(2.74 m)
9 ft(2.74 m)
0
12 ft(3.65 m)
12 ft(3.65 m)
20 ft(6.096m)
20 ft(6.096m)
Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Maximum coverage area mayvary somewhat according to room
shape and the presence of obstacles.
The NEMA WD 7 Guide and roboticmethod were utilized to verify
coverage patterns.
Minor Motion, IR
Major Motion, IR
8.5 ft(2.59 m)
5 ft(1.52 m)
10 ft(3.05 m)
15 ft(4.57 m)
23 ft(7.01 m)
0
9 ft(2.74 m)
9 ft(2.74 m)
0
12 ft(3.65 m)
12 ft(3.65 m)
20 ft(6.096m)
20 ft(6.096m)
4 EATON www.eaton.com/wiringdevices Compliances, specifications and availability are subject to change without notice.
1 2 3 4 5 6 7 8 9 10 11 12
ON
Daylight Sensor Adjustment Ultrasonic Sensitivity Adjustment
PIR Detector
Not UsedOverrideLEDs
(DMV model only) (DMV model only)
Daylighting Bathroom Mode Relay Swap
Pot 1 - Blue (0-300 FC)
Ultrasonic
(-R model only)
Pot 2 - Green
(DMV model only)
Not Used
Relay 2
Relay 1 & 2
Controls (Line voltage)
Technical Data Effective September 2018
Certifications & compliancesCatalog no.
AHAC-DT-2000 • •
AHAC-DT-1000 • •
AHAC-DT-0501 • •
AHAC-DT-2000-MV • •
AHAC-DT-2000-DMV • •
AHAC-STEM
Compliances, specifications and availability are subject to change without notice.
KEY: cULus RoHS
Electrical Sector203 Cooper CirclePeachtree City, GA 30269United StatesEaton.comEaton.com/wiringdevices
Electrical SectorCanada Operations5925 McLaughlin RoadMississauga, Ontario, L5R 1B8CanadaEatonCanada.caEaton.com/wiringdevices
Electrical SectorMexico OperationsCarr. Tlalnepantla -Cuautitlan Km 17.8 s/nCol. Villa Jardin esq.Cerrada 8 de MayoCuautitlan, Mexico CP 54800MexicoEaton.mxEaton.com/wiringdevices
Eaton is a registered trademark.
All other trademarks are property of their respective owners.
Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com
© 2018 EatonAll Rights ReservedPrinted in USAPublication No. TD620042EN (REV 1)September 2018
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
AHAC-DT – MicroSet dual tech low/line voltage ceiling sensor