AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR … · MODULAR HYDRONIC HEAT KITS Heat kits...

3
STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air. Offset hanging brackets attach to unit and wall to allow hanging inside closet. Can be AHRI matched with most brands of air con- ditioners or heat pumps. ETL listed for use with either R22 or R410a when a proper metering device is used. MOTOR X13 speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. CABINET Sturdy, short galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2” faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. Low leak cabinet features are standard. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing 16,000 to 59,000 BTU’s of heat. Heat kits are easily in- stalled in the field using molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are ac- cessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Heat kits are available with or without circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are standard on water-out manifold, hose bib available as an option. Totally lead free constructed coil. Suitable for potable applications. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressur- ized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either check style flowrater or TXV metering device. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4” FPT. Access door allows for coil clean- ing. WARRANTY Five-year limited parts warranty. OPTIONS See options menu. Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Revised 04/02/14. In keeping with its policy of continuous progress and product improvement, Aspen reserves the right to make changes without notice and incurring obligation. © 2014 PRODUCT DIMENSIONS & SPECIFICATIONS AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR HANDLERS Phone: 281.441.6500 Toll Free: 800.423.9007 Fax: 281.441.6510 www.aspenmfg.com * For complete warranty details visit www.aspenmfg.com.

Transcript of AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR … · MODULAR HYDRONIC HEAT KITS Heat kits...

Page 1: AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR … · MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing

STANDARD FEATURES

APPLICATION VERSATILITYFront or bottom return air. Offset hanging brackets attach to unit and wall to allow hanging inside closet. Can be AHRI matched with most brands of air con-ditioners or heat pumps. ETL listed for use with either R22 or R410a when a proper metering device is used.

MOTORX13 speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory.

CABINETSturdy, short galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2” faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. Low leak cabinet features are standard.

MODULAR HYDRONIC HEAT KITSHeat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing 16,000 to 59,000 BTU’s of heat. Heat kits are easily in-stalled in the field using molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are ac-cessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Heat kits are available with or without circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are standard on water-out manifold, hose bib available as an option. Totally lead free constructed coil. Suitable for potable applications.

BLOWERDirect drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service.

ELECTRONIC CONTROL BOARDAn electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle.

DX COILHigh efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressur-ized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either check style flowrater or TXV metering device. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4” FPT. Access door allows for coil clean-ing.

WARRANTYFive-year limited parts warranty.

OPTIONSSee options menu.

Representative image only. Some models may vary in appearance. Due to continuous product improvement,

specifications are subject to change without notice.

Revised 04/02/14. In keeping with its policy of continuous progress and product improvement, Aspen reserves the right to make changes without notice and incurring obligation. © 2014

PRODUCT DIMENSIONS & SPECIFICATIONS

AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR HANDLERS

Phone: 281.441.6500Toll Free: 800.423.9007Fax: 281.441.6510www.aspenmfg.com

* For complete warranty details visit www.aspenmfg.com.

Page 2: AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR … · MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing

HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA

M O D E LH Y D R O N I C H E A T K I T

P E R F O R M A N C E D A T A E L E C T R I C A L D A T A

N O M I N A LC O O L I N G

H E A T I N G C O I L

H E A T I N G C A P A C I T Y B T U / H R a t 3 G P M

M I N . C I R .A M P A C I T Y

M A XF U S E

O RC I R C U I T

B R E A K E RE N T E R I N G W A T E R T E M P

R O W S S I Z E 1 2 0 O 1 4 0 O 1 8 0 O

AFW18UC2SP

1.52

18”x10-1/2

16100 22800 363006 . 6 15

UC3SP 3 18500 26100 41600

AFW24UC2SP

2.02 18200 25800 41200

6.6 15UC3SP 3 21200 29900 47700

AFW30

UC2SP

2.5

2 19900 28100 45000

9 . 0 15UC3SP 3 23200 32800 52400

UC4SP 4 24300 34400 54900

AFW36

UC2SP

3.0

2 21200 30000 48000

9.0 15UC3SP 3 24800 35200 56200

UC4SP 4 26100 36900 59000

HYDRONIC HEAT KIT NOMENCLATURE

U C 2 S P

Wall MountHydronic Heat

InterruptionC = Circuit BreakerT = Terminal Block

# of rows2 = 2 rows3 = 3 rows4 = 4 rows

S = 18 - 36P = with pumpL = less pump

AIR HANDLER CHASSIS NOMENCLATURE

A F W 1 8 G - 0 0 1

AFW = 115V X13 MotorVertical Wall Mount

Nominal tonnage (MBTUH)

Metering device4 = non-bleed A/C or H/P R410 TXVB = 20% bleed A/C or H/P R22 TXV

F = Flo-raterG = R410a Flo-rater

X = non-bleed A/C or H/P R22 TXV

Option Code

BLOWER DATA

M O D E LS P E E D

T A PM O T O R

H PM O T O R A M P S

M O T O R V O L T A G E

C F M V . E X T E R N A L S T A T I C *

0 . 1 0 0 . 2 0 0 . 3 0 0 . 4 0 0 . 5 0

AFW18 & AFW 24

TAP 5

1/3 4.8

120

900 851 800 742 682

TAP 4 652 630 591 556 530

TAP 3 500 476 452 421 400

TAP 2 400 381 360 339 312

TAP 1 900 851 800 742 682

AFW30 & AFW36

TAP 5

1/2 6.8

1150 1087 1030 975 910

TAP 4 1080 1048 1010 960 895

TAP 3 900 862 825 796 745

TAP 2 700 663 632 600 552

TAP 1 500 473 449 421 395

*Dry coil with filter

Page 3: AFW SERIES WALL MOUNT HYDRONIC HEAT DX COOL AIR … · MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing

Phone: 281.441.6500Toll Free: 800.423.9007Fax: 281.441.6510www.aspenmfg.com

INSTALLATION CLEARANCES

O P E R A T I O N S E R V I C E

TOP 0” 0”

FRONT 0” 30”

SIDES 0” 0”

REAR 0” 0”

DIMENSIONS AND SPECIFICATIONS (Fig 1)

M O D E LH E I G H T

A ”W I D T H

B ”D E P T H

C ”D ” E ”

F I L T E R S I Z E

P I S T O N S I Z E

S H I P W E I G H T

( L B S )

S K I D Q T Y

AFW18*44-1/2(113)

22(56)

18 3/4(48)

17 5/8(45)

10-1/2(27) 20X20 0.055 110 4

AFW24*44-1/2(113)

22(56)

18 3/4(48)

17 5/8(45)

10-1/2(27) 20X20 0.059 110 4

AFW30*44-1/2(113)

22(56)

18 3/4(48)

17 5/8(45)

10-1/2(27) 20X20 0.068 118 4

AFW36*44-1/2(113)

22(56)

18 3/4(48)

17 5/8(45)

10-1/2(27) 20X20 0.074 118 4

ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2)

P A N E LM O D E L

F O R U S E W I T HO P E N I N G S I Z E P A N E L D I M E N S I O N F R A M E D I M E N S I O N # O F

P A N E L SA B C D E F

WAD-10(S/L) [+ 6”] AFW 22-1/4 52 24-1/4 54 24-1/8 47-7/8 1

Fig 1